Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Horm Behav ; 103: 129-139, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29953885

RESUMO

Despite the growing evidence for the importance of developmental experiences shaping consistent individual differences in behaviour and physiology, the role of endocrine factors underlying the development and maintenance of such differences across multiple traits, remains poorly understood. Here, we investigated how an experimental manipulation of circulating glucocorticoids during early adolescence affects behavioural and physiological variation and covariation later in life in the precocial cavy (Cavia aperea). Plasma cortisol concentrations were experimentally elevated by administering cortisol via food for 3 weeks. Struggle docility, escape latency, boldness, exploration and social behaviour were then tested three times after individuals attained sexual maturity. In addition, blood samples were taken repeatedly to monitor circulating cortisol concentrations. Exogenous cortisol affected mean trait expression of plasma cortisol levels, struggle docility and escape latency. Repeatability of cortisol and escape latency was increased and repeatability of struggle docility tended to be higher (approaching significance) in treated individuals. Increased repeatability was mainly caused by an increase of among-individual variance. Correlations among docility, escape latency and cortisol were stronger in treated animals compared to control animals. These results suggest that exposure to elevated levels of cortisol during adolescence can alter animal personality traits as well as behavioural syndromes. Social and risk-taking traits showed no correlation with cortisol levels and were unaffected by the experimental manipulation, indicating behavioural modularity. Taken together, our data highlight that cortisol can have organising effects during adolescence on the development of personality traits and behavioural syndromes, adding to the increasing evidence that not only early life but also adolescence is an important sensitive period for behavioural development.


Assuntos
Comportamento Animal/efeitos dos fármacos , Cobaias/fisiologia , Hidrocortisona/farmacologia , Maturidade Sexual/efeitos dos fármacos , Comportamento Social , Estresse Fisiológico/efeitos dos fármacos , Animais , Comportamento Animal/fisiologia , Comportamento Exploratório/efeitos dos fármacos , Comportamento Exploratório/fisiologia , Feminino , Glucocorticoides/metabolismo , Cobaias/crescimento & desenvolvimento , Hidrocortisona/fisiologia , Individualidade , Masculino , Fenótipo , Maturidade Sexual/fisiologia , Estresse Fisiológico/fisiologia , Síndrome
2.
Orthopade ; 46(1): 78-84, 2017 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-27921130

RESUMO

BACKGROUND: Certification according to EndoCert in the field of arthroplasty in Germany aims at standardization of treatment and with this optimization of its quality. However, huge capital investment and efforts are necessary. There are currently more than 400 certified centres in Germany. Our Department of Orthopaedics at a German medical school was certified in the pilot phase. The aim of this study was to analyse whether there was a difference in the quality in the year after the certification. A second aim was to analyse whether the defined quality criteria are adequate for a university hospital. MATERIALS AND METHODS: The quality criteria as defined by EndoCert were analysed in the year before (2011) and after certification (2012). The observed complications were noted for 1 year postoperatively. The clinical outcome was analysed with Western Ontario and McMaster University Osteoarthritis Index Score (WOMAC) 1 year postoperatively. RESULTS: There was no difference concerning the criteria analysed, including the clinical outcome in the year before and that after certification. In both years, nearly all criteria could be reached except the operation time and the infection rate in hip and knee revision surgery. CONCLUSION: Certification did not lead to a measurable change of the quality of care. Nearly all criteria, except the infection rate in revision arthroplasty (required: less than 3% at 1 year postop.) and the operation duration could be fulfilled. This rate as well as the operation duration should be revised. Certification according to EndoCert is an important tool to prove quality care, however big efforts and capital are needed. The criteria should be constantly revised and reduced, as these resources should not be missed in patient care.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Artroplastia de Quadril/normas , Artroplastia do Joelho/estatística & dados numéricos , Artroplastia do Joelho/normas , Certificação/normas , Complicações Pós-Operatórias/epidemiologia , Melhoria de Qualidade/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Resultado do Tratamento
3.
Orthopade ; 46(2): 142-147, 2017 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-28083683

RESUMO

BACKGROUND: In case of hip revision arthroplasty, one component (cup/stem) is often well fixed and does not need to be exchanged. The newly implanted component needs to be compatible with the well-fixed implant. The combination of implants from different companies leads to "mix and match" or even mismatch between the implants. OBJECTIVES AND METHODS: The objective of this work was to describe possible combinations including their specifications that need to be considered in partial exchange of hip prostheses. For this purpose the literature, surgical techniques of companies and judgements concerning this topic were analysed and our own results and experiences were included. RESULTS AND CONCLUSIONS: Partial revision arthroplasty can be challenging and needs to be planned in detail. In case of isolated cup or inlay revision with exchange of a modular head the cone of the stem needs to be identified. A ceramic head may be used in revision with a titanium sleeve even from a different company as long as they are compatible. Patients however need to give their informed consent for this mix and match procedure. This procedure is done frequently and good study results support this, however from a juristic point of view a definite recommendation cannot be given. If the inlay of a cup is replaced, the original inlay should be used. If this is not available anymore, it can be manufactured as a special product in many cases. If this is also not possible, an inlay can also be cemented into a well-fixed cup. Biomechanical and clinical studies support this off-label technique. In case of an isolated exchange of the stem with a ceramic inlay that is retained in a well-fixed cup, the revision stem and ceramic head need to be from the same company as the cup. In case of ceramic fracture, a ceramic head with a titanium sleeve should be combined with a PE or ceramic inlay, a metal head or inlay should never be used.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Reoperação/instrumentação , Reoperação/métodos , Acetabuloplastia/instrumentação , Acetabuloplastia/métodos , Acetábulo/cirurgia , Terapia Combinada , Medicina Baseada em Evidências , Humanos , Osteotomia/instrumentação , Osteotomia/métodos , Desenho de Prótese , Procedimentos de Cirurgia Plástica/instrumentação , Procedimentos de Cirurgia Plástica/métodos , Resultado do Tratamento
4.
Nanotechnology ; 27(26): 265708, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-27197624

RESUMO

Sharp nanoscale tips on the metal surfaces of electrodes enhance locally applied electric fields. Strongly enhanced electric fields trigger electron field emission and atom evaporation from the apexes of nanotips. Together, these processes may explain electric discharges in the form of small local arcs observed near metal surfaces in the presence of electric fields, even in ultra-high vacuum conditions. In the present work, we investigate the stability of nanoscale tips by means of computer simulations of surface diffusion processes on copper, the main material used in high-voltage electronics. We study the stability and lifetime of thin copper (Cu) surface nanotips at different temperatures in terms of diffusion processes. For this purpose we have developed a surface kinetic Monte Carlo (KMC) model where the jump processes are described by tabulated precalculated energy barriers. We show that tall surface features with high aspect ratios can be fairly stable at room temperature. However, the stability was found to depend strongly on the temperature: 13 nm nanotips with the major axes in the [Formula: see text] crystallographic directions were found to flatten down to half of the original height in less than 100 ns at temperatures close to the melting point, whereas no significant change in the height of these nanotips was observed after 10 [Formula: see text] at room temperature. Moreover, the nanotips built up along the [Formula: see text] crystallographic directions were found to be significantly more stable than those oriented in the [Formula: see text] or [Formula: see text] crystallographic directions. The proposed KMC model has been found to be well-suited for simulating atomic surface processes and was validated against molecular dynamics simulation results via the comparison of the flattening times obtained by both methods. We also note that the KMC simulations were two orders of magnitude computationally faster than the corresponding molecular dynamics calculations.

5.
Unfallchirurg ; 119(6): 488-92, 2016 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-27160728

RESUMO

The German Arthroplasty Registry (EPRD) was founded in 2010 and has been in full operation since 2014. Previous attempts at a systematic data collection of elective and non-elective knee and hip replacement in Germany failed mainly because of the long-term lack of funding. The EPRD is an interdisciplinary collaborative partnership between the German Association of Orthopedics and Orthopedic Surgery (DGOOC), all implant manufacturers of the German Medical Technology Association (BVMed), health insurers (AOK and the Association of Additional Healthcare Insurance) and hospitals (German Hospital Federation). As part of this cooperation a worldwide unique implant database has been set up, which includes all relevant components and a detailed description of implant specifications. This implant library enables a detailed evaluation of implant survival, revision rates and possible inferior implant performance of knee and hip replacements in Germany. At the end of 2015 the EPRD encompassed over 200,000 registered operations. Due to the high number of hip and knee arthroplasties in Germany with many different implants from different manufacturers there will be a rapid growth of data that are available for a national and also international comparison of the results.


Assuntos
Artroplastia de Substituição/estatística & dados numéricos , Artropatias/epidemiologia , Artropatias/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Vigilância da População/métodos , Sistema de Registros/estatística & dados numéricos , Artroplastia de Substituição/tendências , Conjuntos de Dados como Assunto/estatística & dados numéricos , Medicina Baseada em Evidências/métodos , Previsões , Alemanha/epidemiologia , Humanos , Disseminação de Informação/métodos , Ortopedia/tendências , Avaliação de Resultados em Cuidados de Saúde/tendências , Sistema de Registros/classificação , Traumatologia/tendências
6.
Scand J Rheumatol ; 44(6): 456-63, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26114440

RESUMO

OBJECTIVES: Cationic lipid complexes bind to angiogenic endothelial cells of solid tumours and microvessels of chronic inflammatory tissue. Methotrexate (MTX) is one of the drugs used in the therapy of rheumatoid arthritis (RA); it is applied systemically but can have serious side-effects. The aim of this study was to investigate the impact of MTX encapsulated in cationic liposomes (EndoMTX) in comparison to treatment with free MTX. METHOD: We used an antigen-induced arthritis (AiA) model and investigated the leucocyte- and platelet-endothelial cell interaction in arthritic female C57/Bl6 mice and in healthy controls. The arthritic animals were divided into four different groups receiving either trehalose, free MTX, EndoMTX placebo, or EndoMTX. These parameters and functional capillary density (FCD) were measured and assessed by intravital microscopy (IVM). We controlled clinical parameters such as the knee joint diameter (KJD) throughout the observation period. RESULTS: Animals treated with EndoMTX showed a significant and superior reduction in leucocyte- and platelet-endothelial cell interaction, FCD, and KJD. Free MTX or empty liposomes also showed a reduction in these parameters but not to a significant level. FCD decreased in the EndoMTX group in comparison to using free drugs or empty carrier-like liposomes. CONCLUSIONS: This study demonstrates the advantage of using MTX encapsulated in cationic liposomes in contrast to free and generic MTX, with a higher efficacy in anti-inflammatory and anti-angiogenic abilities. Targeting with cationic liposomes may be a promising treatment option and should be elucidated in further experiments regarding dose reduction and side-effects due to MTX usage.


Assuntos
Antirreumáticos/administração & dosagem , Antirreumáticos/uso terapêutico , Artrite Experimental/tratamento farmacológico , Artrite Reumatoide/tratamento farmacológico , Artrite Reumatoide/imunologia , Metotrexato/administração & dosagem , Metotrexato/uso terapêutico , Administração Intravenosa , Animais , Antígenos de Bactérias/efeitos adversos , Artrite Experimental/induzido quimicamente , Artrite Experimental/patologia , Artrite Reumatoide/patologia , Plaquetas/patologia , Cápsulas , Comunicação Celular/fisiologia , Modelos Animais de Doenças , Células Endoteliais/patologia , Feminino , Articulação do Joelho/irrigação sanguínea , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Leucócitos/patologia , Lipossomos , Camundongos , Camundongos Endogâmicos C57BL , Microcirculação/fisiologia , Radiografia , Resultado do Tratamento
7.
Scand J Rheumatol ; 43(5): 356-63, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24825390

RESUMO

OBJECTIVES: The use of statins in the prevention and treatment of cardiovascular diseases is well established. Their use as anti-inflammatory and immunomodulatory agents in the treatment of rheumatoid arthritis (RA) has also been investigated, with several clinical and experimental studies indicating an anti-inflammatory effect of statins for RA, but other studies showing no effect or even the opposite. The current study was designed to examine the effect of simvastatin in an in vivo murine model of arthritis using intravital microscopy. METHOD: We assigned four groups (n = 7, female C57Bl6 mice), two with and two without antigen-induced arthritis (AiA), from which one of the non-AiA groups and one of the AiA groups were treated with simvastatin 40 mg/kg i.p. daily for 14 consecutive days after induction of arthritis. Platelet- and leucocyte-endothelial cell interaction was assessed by measurement of rolling and adherent fluorescence-labelled platelets and leucocytes, functional capillary density (FCD) was evaluated, and knee joint diameter was determined as a clinical parameter. RESULTS: In arthritic mice treated with simvastatin, a significant reduction in platelet- and leucocyte-endothelial cell interaction was observed in comparison to arthritic mice treated with vehicle. In addition, a significant reduction in FCD was seen in arthritic mice treated with simvastatin, along with a reduction in knee joint swelling of the AiA mice. CONCLUSIONS: Treatment of AiA mice with simvastatin showed significant reductions in platelet- and leucocyte-endothelial cell interactions, in FCD, and in the swelling of the knee joint. These results support the hypothesis of the anti-inflammatory effects of statins in the treatment of RA.


Assuntos
Antígenos/efeitos adversos , Artrite Experimental/patologia , Plaquetas/efeitos dos fármacos , Comunicação Celular/efeitos dos fármacos , Endotélio Vascular/efeitos dos fármacos , Leucócitos/efeitos dos fármacos , Sinvastatina/farmacologia , Animais , Anti-Inflamatórios/farmacologia , Artrite Experimental/induzido quimicamente , Artrite Experimental/imunologia , Plaquetas/patologia , Capilares/efeitos dos fármacos , Capilares/patologia , Modelos Animais de Doenças , Endotélio Vascular/patologia , Feminino , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Articulação do Joelho/efeitos dos fármacos , Articulação do Joelho/patologia , Leucócitos/patologia , Camundongos , Camundongos Endogâmicos C57BL , Microscopia de Fluorescência
8.
J Mater Sci Mater Med ; 25(1): 141-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24068541

RESUMO

Due to their mechanical properties, there has been growing interest in poly-ether-ether-ketone (PEEK) and its composites as bearing material in total and unicompartmental knee arthroplasty. The aim of this study was to analyze the biological activity of wear particles of two different (pitch and PAN) carbon-fiber-reinforced- (CFR-) PEEK varieties in comparison to ultra-high-molecular-weight-polyethylene (UHMWPE) in vivo. The authors hypothesized no difference between the used biomaterials. Wear particle suspensions of the particulate biomaterials were injected into knee joints of Balb/c mice, which were sacrificed after seven days. The cytokine expression (IL-1ß, IL-6, TNF-α) was analyzed immunohistochemically in the synovial layer, the adjacent bone marrow and the articular cartilage. Especially in the bone marrow of the two CFR-PEEK varieties there were increased cytokine expressions compared to the control and UHMWPE group. Furthermore, in the articular cartilage the CFR-PEEK pitch group showed an enhanced cytokine expression, which could be a negative predictor for the use in unicondylar knee systems. As these data suggest an increased proinflammatory potential of CFR-PEEK and its composites in vivo, the initial hypothesis had to be refuted. Summarizing these results, CFR-PEEK seems not to be an attractive alternative to UHMWPE as a bearing material, especially in unicompartmental knee arthroplasty.


Assuntos
Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/química , Citocinas/biossíntese , Cetonas/efeitos adversos , Cetonas/química , Prótese do Joelho/efeitos adversos , Polietilenoglicóis/efeitos adversos , Polietilenoglicóis/química , Polietilenos/efeitos adversos , Polietilenos/química , Falha de Prótese , Animais , Benzofenonas , Medula Óssea/imunologia , Medula Óssea/patologia , Carbono/química , Fibra de Carbono , Cartilagem Articular/imunologia , Cartilagem Articular/patologia , Análise de Falha de Equipamento , Feminino , Interleucina-1beta/biossíntese , Interleucina-6/biossíntese , Teste de Materiais , Camundongos , Camundongos Endogâmicos BALB C , Modelos Animais , Tamanho da Partícula , Polímeros , Membrana Sinovial/imunologia , Membrana Sinovial/patologia , Fator de Necrose Tumoral alfa/biossíntese
9.
J Mater Sci Mater Med ; 25(2): 507-13, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24249629

RESUMO

A cellular and receptor mediated response to ultra-high-molecular-weight-polyethylene (UHMWPE) wear particles results in a release of proinflammatory cytokines and induces an inflammatory reaction causing osteolysis in total joint replacement. This investigation offers insight into the toll-like receptor (TLR) mediated activation by polyethylene wear particles in the synovial layer of mice. We hypothesized that, similar to recent in vitro results, UHMWPE particles lead to an upregulation of TLR 1 and 2 and TLR 4 in vivo in the synovial tissue of mice as well. Therefore, UHMWPE particles were generated in a common knee simulator according to the ISO standard, separated by acid digestion and determined by scanning electron microscopy. Endotoxin was removed using a method based on ultracentrifugation. A particle suspension (50 µl; 0.1 vol./vol.%) was injected into the left knee joint of female Balb/c mice (n = 8). In a control group, phosphate-buffered saline was injected into the left knee of Balb/c mice (n = 8). The mice were sacrificed after 7 days. Immunohistochemical staining was performed with TLR 1, 2 and 4 polyclonal antibodies for Balb/c mice and evaluated by light microscopy. The particle-stimulated group showed a thickened synovial layer, an increased cellular infiltration and a TLR 2-upregulation in the synovial layer compared to the control group. An increased expression of TLR 1 and TLR 4 could not be demonstrated. These results indicate a mainly TLR 2-induced inflammation to polyethylene wear debris in the synovial layer of mice.


Assuntos
Polietileno/química , Membrana Sinovial/metabolismo , Receptor 2 Toll-Like/metabolismo , Regulação para Cima , Animais , Feminino , Camundongos , Camundongos Endogâmicos BALB C , Tamanho da Partícula
10.
J Mater Sci Mater Med ; 25(6): 1599-612, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24562818

RESUMO

Wear of polyethylene causes loosening of joint prostheses because of the particle mediated activity of the host tissue. It was hypothesized that conventional and crosslinked polyethylene particles lead to similar biological effects around the knee joint in vivo as well as to a similar particle distribution in the surrounding tissues. To verify these hypotheses, particle suspensions of six different polyethylene materials were injected into knee joints of Balb/C mice and intravital microscopic, histological and immunohistochemical evaluations were done after 1 week. Whereas the biological effects on the synovial layer and the subchondral bone of femur and tibia were similar for all the polyethylenes, two crosslinked materials showed an elevated cytokine expression in the articular cartilage. Furthermore, the distribution of particles around the joint was dependent on the injected polyethylene material. Those crosslinked particles, which remained mainly in the joint space, showed an increased expression of TNF-alpha in articular cartilage. The data of this study support the use of crosslinked polyethylene in total knee arthroplasty. In contrast, the presence of certain crosslinked wear particles in the joint space can lead to an elevated inflammatory reaction in the remaining cartilage, which challenges the potential use of those crosslinked polyethylenes for unicondylar knee prostheses.


Assuntos
Materiais Biocompatíveis/toxicidade , Migração de Corpo Estranho/imunologia , Articulação do Joelho/efeitos dos fármacos , Articulação do Joelho/imunologia , Prótese do Joelho/efeitos adversos , Polietileno/imunologia , Polietileno/toxicidade , Animais , Materiais Biocompatíveis/química , Análise de Falha de Equipamento , Feminino , Migração de Corpo Estranho/etiologia , Teste de Materiais , Camundongos , Camundongos Endogâmicos BALB C , Tamanho da Partícula , Polietileno/química , Desenho de Prótese
11.
Orthopade ; 43(6): 515-21, 2014 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-24832377

RESUMO

BACKGROUND: Polyethylene is still one of the most important materials in the field of hip and knee arthroplasty. The clinical results of the last decades have helped to further develop polyethylene into a high-tech material. Progress in the development of new materials must be compared with the tried and tested ones to provide optimal and most individual patient care. OBJECTIVES: This article gives an overview of the history and current application profile of the material ultra-high molecular weight polyethylene (UHMWPE) in hip and knee arthroplasty. MATERIAL AND METHODS: With the aid of the current literature, new developments in the field of the material UHMWPE, also with respect to the biological activity of wear, the particular biomechanics of the knee joint as well as alternative hard-hard bearing surfaces in the hip, are represented in terms of implant safety. RESULTS: The problems concerning polyethylene are now well recognized. The disadvantages of the material UHMWPE could be consistently reduced based on material research so that modern polyethylenes have gradually been shown in clinical trials that they can be reliably used. CONCLUSION: Despite this the potential for improvement has still not yet been fully exploited. Any further development must be extensively tested both biomechanically and biologically before the material can be used in vivo. Long-term results are still necessary before a material can be accepted as being clinically safe.


Assuntos
Materiais Biocompatíveis/química , Prótese de Quadril , Prótese do Joelho , Polietileno/química , Análise de Falha de Equipamento , Teste de Materiais , Desenho de Prótese
12.
Orthopade ; 43(10): 905-12, 2014 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-25227528

RESUMO

BACKGROUND: Unicompartmental knee arthroplasty (UKA) has become an accepted therapy for medial osteoarthritis. The main reasons for its popularity are the minimally invasive surgical technique and the reports of excellent long-term results including high patient satisfaction and good knee joint function especially in younger patients. OBJECTIVES: The purpose of our retrospective study was to evaluate the physical activities of patients who had undergone an Oxford III medial UKA. Special attention was paid to implant positioning and osteoarthritis of the patellofemoral joint. MATERIALS AND METHODS: Of 181 implanted Oxford III prosthesis, 136 (75.1%) could be followed up. The mean age at time of surgery was 65.2 years; the average time of follow-up was 4.2 years. In addition to a physical examination and x-ray, the following scores were obtained: WOMAC (Western Ontario and McMaster Osteoarthritis Index), OKS (Oxford Knee Score), KSS (Knee Society Score), UCLA activity and the Turba score. RESULTS: The majority of the patients (81%) returned to their sporting activity following knee surgery. Higher complication rates or progression of osteoarthritis associated with sporting activities were not observed. The active patients had significantly higher scores for the OKS, KSS, WOMAC, and UCLA scores. The correct implant position, especially avoiding overcorrection to valgus malalignment, is important for good clinical outcome. CONCLUSION: Our results demonstrate that a high degree of patient satisfaction in terms of physical and sporting activity can be achieved using the Oxford III UKA for medial osteoarthritis without an increased risk for complications.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Prótese do Joelho , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/cirurgia , Articulação Patelofemoral/cirurgia , Idoso , Análise de Falha de Equipamento , Humanos , Articulação Patelofemoral/diagnóstico por imagem , Desenho de Prótese , Radiografia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Resultado do Tratamento
13.
Infection ; 41(2): 479-83, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23225209

RESUMO

PURPOSE: Before elective operations, particularly orthopaedic surgery, national guidelines in Germany recommend testing for human immunodeficiency virus (HIV), hepatitis B virus (HBV), and hepatitis C virus (HCV) to reduce the risk of transmission of the virus through a needlestick or cutting injury. Such testing is expensive. The number of new and unknown diagnoses of viral infections that can be detected by routine screening has not yet been evaluated. METHODS: The aim of our department of orthopaedic surgery is to screen every adult patient listed for an operation for HBV, HCV and HIV. We retrospectively analysed the number of operations in this single centre from 2001 to 2010, correlated this number with the total number of screens and calculated the number of newly diagnosed infections. An additional cost:benefit ratio was calculated. RESULTS: A total of 20,869 operations were performed by the department between 2001 and 2010. After exclusion of all interventions in children and all patients who had multiple operations, 15,482 patients remained. Test results were found for 10,011 of these patients during this period (screening rate 65 %). Of those screened, in only four cases (0.4 ‰) was a previously unknown infection detected. CONCLUSIONS: Two-thirds of the patients included in our study actually underwent screening; this rate was lower than expected. The incidence of newly detected infections was low, putting the benefit of a routine preoperative screening for HBV, HCV and HIV into question. From an economic point of view the low detection rate is a strong argument in favour of omitting routine preoperative screening. Screening only those patients with risk factors may be as safe as screening every patient and would help reduce costs.


Assuntos
Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Infecções por HIV/diagnóstico , Hepatite B/diagnóstico , Hepatite C/diagnóstico , Testes Obrigatórios/estatística & dados numéricos , Procedimentos Ortopédicos/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Alemanha , HIV/isolamento & purificação , Hepacivirus/isolamento & purificação , Vírus da Hepatite B/isolamento & purificação , Humanos , Testes Obrigatórios/economia , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
14.
J Mater Sci Mater Med ; 24(1): 211-20, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23090834

RESUMO

In order to investigate cell-based tendon regeneration, a tendon rupture was simulated by utilizing a critical full-size model in female rat achilles tendons. For bridging the defect, polyglycol acid (PGA) and collagen type I scaffolds were used and fixed with a frame suture to ensure postoperatively a functional continuity. Scaffolds were seeded with mesenchymal stem cells (MSC) or tenocytes derived from male animals, while control groups were left without cells. After a healing period of 16 weeks, biomechanical, PCR, histologic, and electron microscopic analyses of the regenerates were performed. Genomic PCR for male-specific gene was used to detect transplanted cells in the regenerates. After 16 weeks, central ossification and tendon-like tissue in the superficial tendon layers were observed in all study groups. Biomechanical test showed that samples loaded with tenocytes had significantly better failure strength/cross-section ratio (P < 0.01) compared to MSC and the control groups whereas maximum failure strength was similar in all groups. Thus, we concluded that the application of tenocytes improves the outcome in this model concerning the grade of ossification and the mechanical properties in comparison to the use of MSC or just scaffold materials.


Assuntos
Materiais Biocompatíveis , Células-Tronco Mesenquimais/citologia , Tendões/citologia , Alicerces Teciduais , Animais , Sequência de Bases , Fenômenos Biomecânicos , Primers do DNA , Feminino , Masculino , Microscopia Eletrônica de Transmissão , Reação em Cadeia da Polimerase , Ratos , Ratos Endogâmicos Lew
15.
Orthopade ; 42(5): 302-4, 306-8, 2013 May.
Artigo em Alemão | MEDLINE | ID: mdl-23615626

RESUMO

In contrast to fracture fixation, when performing an osteotomy the surgeon is able to plan preoperatively. The resulting fixation and compression of the bone fragments are the most important points. A stable osteosynthesis should prevent dislocation of bone fragments and improve bone healing. Beside plates, cerclages can be used for tension band or diaphysis bone fixation. Moreover, cortical or cancellous screws can be used for osteotomy fixation. This work describes biomechanical principles for fixation after an osteotomy with cerclages and cortical or cancellous screws. It also summarizes the materials and geometries used, as well as their influence on the stability of the osteosynthesis.


Assuntos
Parafusos Ósseos , Fios Ortopédicos , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/fisiopatologia , Fraturas Ósseas/cirurgia , Modelos Biológicos , Osteotomia/instrumentação , Análise de Falha de Equipamento , Fixação Interna de Fraturas/métodos , Fricção , Humanos , Osteotomia/métodos , Desenho de Prótese , Resistência à Tração
16.
Acta Chir Belg ; 113(2): 123-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23741931

RESUMO

BACKGROUND: Hip resurfacing arthroplasty is known to increase the metal ion concentration in the serum, urine and whole blood, with potentially adverse effects on the organism. However, only few data are available about the metal ion concentrations in erythrocytes, although they are directly exposed to the higher concentrations of the serum. METHODS: The ion levels of chromium, cobalt, nickel and molybdenum in erythrocytes of 25 patients with a hip resurfacing implant were analysed with high resolution ICP-sf-MS (inductively-coupled-plasma-sector-field-mass-spectrometry). The results were compared to the ion levels in the serum and urine of the patients, and also to the ion levels of 27 control persons without an implant. RESULTS: Compared to the control group, ion levels in the erythrocytes of the hip resurfacing group were markedly increased for cobalt (0.10 vs. 3.26 microg/kg) and slightly for chromium (6.04 vs. 7.38 microg/kg). In contrast, ion levels in the serum of the hip resurfacing group were increased for cobalt (0.21 vs. 1.92 microg/l), chromium (1.48 vs. 5.64 microg/l), nickel (1.53 vs. 4.25 microg/l) and molybdenum (2.17 vs. 3.78 microg/l). CONCLUSION: Ion concentrations of cobalt and chromium are also increased in erythrocytes after hip resurfacing arthroplasty. Further research is required to evaluate the impact of the elevated ion levels on the erythrocytes, and to evaluate if metal ions also accumulate in other tissues of the body.


Assuntos
Artroplastia de Quadril , Eritrócitos/metabolismo , Prótese de Quadril , Artropatias/metabolismo , Próteses Articulares Metal-Metal , Metais Pesados/metabolismo , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Íons/sangue , Íons/urina , Artropatias/patologia , Artropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese
17.
Orthopade ; 41(7): 552-9, 2012 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-22732771

RESUMO

BACKGROUND: One of the main goals of the preoperative planning of hip prostheses is adequate shaft positioning with reconstruction of leg length and offset. The purpose of this study was to compare the planned and achieved shaft positions using a modified program for migration measurement. METHODS: In 60 cases of total hip replacement the preoperative planning was compared with the postoperative radiograph using a modified version of the well-established EBRA-FCA program. The results of this new measurement were compared to conventional measurements. In 25 cases the intraobserver and interobserver reliability was determined. RESULTS: The novel measurements correlated best with the measured distance between the greater trochanter and the center of rotation and yielded the best intraobserver and interobserver reliability. In general, cementless stems had a slightly more proximal position (0.65 mm) compared to cemented stems. CONCLUSIONS: The modified program for migration measurement facilitates a reproducible and fast comparison of the planned and achieved shaft positions thus implementing an early and objective control of postoperative shaft position.


Assuntos
Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Cuidados Pré-Operatórios/métodos , Idoso , Feminino , Humanos , Masculino , Radiografia , Recuperação de Função Fisiológica , Resultado do Tratamento
18.
Orthopade ; 41(4): 298-302, 2012 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-22476420

RESUMO

INTRODUCTION: Unicompartmental knee arthroplasty (UKA) has become a standard procedure with good clinical outcome in patients with isolated medial osteoarthritis of the knee. However, the survival rates of UKA are still inferior compared to that of total knee arthroplasty. Aseptic loosening and wear are responsible for more than 50% of revisions. Therefore, this study evaluated the influence of the tibial slope on the wear rate in a medial UKA. MATERIALS AND METHODS: The wear rate of a medial mobile-bearing UKA (Univation® Aesculap, Tuttlingen, Deutschland) was evaluated according to the ISO 14243-1:2002(E) norm with a customized four-station servo-hydraulic knee wear simulator (EndoLab, Thansau, Germany). In the first group, the prostheses was medially implanted with 0° slope (n = 3) and in the second group the prostheses was medially implanted with 8° slope (n = 3). The lateral side was kept constant with 0° in both groups. For each implant, a total of 5.0 million cycles was performed and after every 0.5 million cycles the gravimetric wear rate was determined. RESULTS: The wear rate in the 0° slope group was 3.46 ± 0.59 mg/million cycles and therefore significantly higher than in the 8° slope group with 0.99 ± 0.42 mg/million cycles (p < 0.01). DISCUSSION: An increase in the tibial slope leads to a reduced wear rate in a mobile-bearing UKA. Therefore, at least for this mobile-bearing UKA a higher tibial slope seems favorable to reduce the wear. However, before an optimal position of the tibial slope can be recommended, further investigations are required to evaluate the influence of the tibial slope on other factors, such as the ligament tension or the strain on the lateral compartment.


Assuntos
Prótese do Joelho , Tíbia/fisiopatologia , Tíbia/cirurgia , Análise de Falha de Equipamento , Humanos , Desenho de Prótese
19.
Clin Biomech (Bristol, Avon) ; 92: 105578, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35093798

RESUMO

BACKGROUND: While no gold standard exists for the management of Achilles tendon ruptures, surgical repair is common in healthy and active patients. Minimally invasive repair methods have become increasingly popular, while biomechanical equivalency hasn't been proven yet. METHODS: A mid-substance Achilles tendon rupture was created 6 cm proximal to the calcaneal insertion in 27 fresh-frozen cadaveric ankles. Specimens were randomly allocated to 1 of 3 repair techniques: Huttunen et al. (2014) (1) PARS Achilles Jig System, Nyyssönen et al. (2008) (2) Achilles Midsubstance SpeedBridge™, Schipper and Cohen (2017) (3) Dresdner Instrument and subsequently subjected to cyclic loading with 250 cycles each at 1 Hz with 4 different loading ranges (20-100 N, 20-200 N, 20-300 N, and 20-400 N). FINDINGS: After 250 cycles no significant differences in elongation were observed between PARS and Dresdner Instrument(p = 1.0). Furthermore, SpeedBridge™ repairs elongated less than either Dresdner Instrument (p = 0.0006) or PARS (p = 0.102). Main elongation (85%) occurred within the first 10 cycles with a comparable elongation in between 10 and 100 and 100-250 cycles. While all repairs withstood the first 250 cycles of cyclic loading from 20 to 100 N, only the PARS (468 ± 175) and Midsubstance SpeedBridge™ (538 ± 208) survived more cycles. Within all 3 groups suture cut out was seen to be the most common failure mechanism. INTERPRETATION: Within all groups early repair elongation was seen. While this was least obvious within the SpeedBridge™ technique, ultimate strengths of repairs (cycles to failure) were comparable across PARS and SpeedBridge™ with a decline in the Dresdner Instrument group.


Assuntos
Tendão do Calcâneo , Traumatismos dos Tendões , Tendão do Calcâneo/cirurgia , Fenômenos Biomecânicos , Cadáver , Humanos , Ruptura/cirurgia , Técnicas de Sutura , Suturas , Traumatismos dos Tendões/cirurgia
20.
Knee Surg Sports Traumatol Arthrosc ; 19(10): 1643-8, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21298254

RESUMO

PURPOSE: The posterior tibial slope has a huge influence on the kinematics of the knee. In several orthopedic interventions such as high tibial osteotomy and unicondylar or bicondylar knee replacement changing, the tibial slope can result in altered knee mechanics. Therefore, an exact preoperative measurement of the posterior tibial slope is mandatory. Several methods are used on conventional radiographs and CT scans, but until now there is no standard validated method. The aim of this study was to compare several methods and imaging techniques to measure the posterior tibial slope and to establish a standard and reliable measurement method by radiography. METHODS: Fourteen knees (seven cadavers) were scanned by a 64-slice CT, a 3T-MRI, and true lateral radiographs were performed. The anatomical references (TPAA = tibial proximal anatomical axis; ATC = anterior tibial cortex; PTC = posterior tibial cortex) and the new computed reference (MPA = mean of PTA and ATC) were compared by short as well as long radiographs, CT scan and MRI. The influence of a malrotation in radiographs of the knees was also analyzed. RESULTS: CT scan and MRI are suitable for the measurement of the medial and lateral posterior tibial slopes, the results of the radiographs varied depending on the method used. The new method (MPA) showed the best correlation to the CT scan (r = 0.997), even on short radiographs (10 cm distal the joint line). CONCLUSION: The measurement of the posterior tibial slope on a short lateral radiograph using the MPA is a reliable method and should be established as a standard. LEVEL OF EVIDENCE: Diagnostic study, Level II.


Assuntos
Articulação do Joelho/diagnóstico por imagem , Procedimentos Ortopédicos/métodos , Tíbia/anatomia & histologia , Tíbia/diagnóstico por imagem , Adulto , Fenômenos Biomecânicos , Pesos e Medidas Corporais/métodos , Pesos e Medidas Corporais/normas , Feminino , Humanos , Articulação do Joelho/anatomia & histologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Procedimentos Ortopédicos/normas , Padrões de Referência , Reprodutibilidade dos Testes , Rotação , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA