Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Mutagenesis ; 39(2): 69-77, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38301659

RESUMO

Chemical safety testing plays a crucial role in product and pharmacological development, as well as chemoprevention; however, in vitro genotoxicity safety tests do not always accurately predict the chemicals that will be in vivo carcinogens. If chemicals test positive in vitro for genotoxicity but negative in vivo, this can contribute to unnecessary testing in animals used to confirm erroneous in vitro positive results. Current in vitro tests typically evaluate only genotoxicity endpoints, which limits their potential to detect non-genotoxic carcinogens. The frequency of misleading in vitro positive results can be high, leading to a requirement for more informative in vitro tests. It is now recognized that multiple-endpoint genotoxicity testing may aid more accurate detection of carcinogens and non-carcinogens. The objective of this review was to evaluate the utility of our novel, multiple-endpoint in vitro test, which uses multiple cancer-relevant endpoints to predict carcinogenic potential. The tool assessed micronucleus frequency, p53 expression, p21 expression, mitochondrial respiration, cell cycle abnormalities and, uniquely, cell morphology changes in human lymphoblastoid cell lines, TK6 and MCL-5. The endpoints were used to observe cellular responses to 18 chemicals within the following categories: genotoxic carcinogens, non-genotoxic carcinogens, toxic non-carcinogens, and misleading in vitro positive and negative agents. The number of endpoints significantly altered for each chemical was considered, alongside the holistic Integrated Signature of Carcinogenicity score, derived from the sum of fold changes for all endpoints. Following the calculation of an overall score from these measures, carcinogens exhibited greater potency than non-carcinogens. Genotoxic carcinogens were generally more potent than non-genotoxic carcinogens. This novel approach therefore demonstrated potential for correctly predicting whether chemicals with unknown mechanism may be considered carcinogens. Overall, while further validation is recommended, the test demonstrates potential for the identification of carcinogenic compounds. Adoption of the approach could enable reduced animal use in carcinogenicity testing.


Assuntos
Carcinogênese , Carcinógenos , Animais , Humanos , Carcinógenos/toxicidade , Testes de Carcinogenicidade/métodos , Testes de Mutagenicidade/métodos , Dano ao DNA , Técnicas In Vitro
2.
Small ; 17(15): e2006298, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33480476

RESUMO

Nanomaterials are defined as materials with at least one dimension of 100 nm or less. Their small size confers unique properties that may alter the toxicity profile when compared to larger forms of the same material, requiring additional considerations for safety assessment. There has been a rise in the development of nanomaterials for many applications, and although traditional approaches for toxicity testing may address some of the new toxicity concerns, many may not be directly applicable to nanomaterials and new tools or approaches may need to be developed. Since nanomaterials can exist in many different forms, each of which may cause different adverse biological effects, reliance on traditional in vivo models for safety assessment will simply not be feasible or sustainable, given the volume of materials that may need to be tested. It is essential to consider and develop new in vitro methods that can be applied for hazard identification and risk assessment. Many challenges are associated with using alternative approaches to ensure they are as robust and reliable as traditional in vivo approaches, but by overcoming these issues and adopting new testing strategies there are opportunities to improve safety assessments and reduce the reliance on animal-based toxicity testing strategies.


Assuntos
Nanoestruturas , Testes de Toxicidade , Animais , Nanoestruturas/toxicidade , Medição de Risco
3.
Small ; 17(15): e2006055, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33448117

RESUMO

Whilst the liver possesses the ability to repair and restore sections of damaged tissue following acute injury, prolonged exposure to engineered nanomaterials (ENM) may induce repetitive injury leading to chronic liver disease. Screening ENM cytotoxicity using 3D liver models has recently been performed, but a significant challenge has been the application of such in vitro models for evaluating ENM associated genotoxicity; a vital component of regulatory human health risk assessment. This review considers the benefits, limitations, and adaptations of specific in vitro approaches to assess DNA damage in the liver, whilst identifying critical advancements required to support a multitude of biochemical endpoints, focusing on nano(geno)toxicology (e.g., secondary genotoxicity, DNA damage, and repair following prolonged or repeated exposures).


Assuntos
Nanoestruturas , Dano ao DNA , Humanos , Fígado , Nanoestruturas/toxicidade , Medição de Risco
4.
J Nanobiotechnology ; 19(1): 193, 2021 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-34183029

RESUMO

BACKGROUND: With the continued integration of engineered nanomaterials (ENMs) into everyday applications, it is important to understand their potential for inducing adverse human health effects. However, standard in vitro hazard characterisation approaches suffer limitations for evaluating ENM and so it is imperative to determine these potential hazards under more physiologically relevant and realistic exposure scenarios in target organ systems, to minimise the necessity for in vivo testing. The aim of this study was to determine if acute (24 h) and prolonged (120 h) exposures to five ENMs (TiO2, ZnO, Ag, BaSO4 and CeO2) would have a significantly different toxicological outcome (cytotoxicity, (pro-)inflammatory and genotoxic response) upon 3D human HepG2 liver spheroids. In addition, this study evaluated whether a more realistic, prolonged fractionated and repeated ENM dosing regime induces a significantly different toxicity outcome in liver spheroids as compared to a single, bolus prolonged exposure. RESULTS: Whilst it was found that the five ENMs did not impede liver functionality (e.g. albumin and urea production), induce cytotoxicity or an IL-8 (pro-)inflammatory response, all were found to cause significant genotoxicity following acute exposure. Most statistically significant genotoxic responses were not dose-dependent, with the exception of TiO2. Interestingly, the DNA damage effects observed following acute exposures, were not mirrored in the prolonged exposures, where only 0.2-5.0 µg/mL of ZnO ENMs were found to elicit significant (p ≤ 0.05) genotoxicity. When fractionated, repeated exposure regimes were performed with the test ENMs, no significant (p ≥ 0.05) difference was observed when compared to the single, bolus exposure regime. There was < 5.0% cytotoxicity observed across all exposures, and the mean difference in IL-8 cytokine release and genotoxicity between exposure regimes was 3.425 pg/mL and 0.181%, respectively. CONCLUSION: In conclusion, whilst there was no difference between a single, bolus or fractionated, repeated ENM prolonged exposure regimes upon the toxicological output of 3D HepG2 liver spheroids, there was a difference between acute and prolonged exposures. This study highlights the importance of evaluating more realistic ENM exposures, thereby providing a future in vitro approach to better support ENM hazard assessment in a routine and easily accessible manner.


Assuntos
Dano ao DNA/efeitos dos fármacos , Fígado/patologia , Nanoestruturas/administração & dosagem , Nanoestruturas/toxicidade , Albuminas , Proliferação de Células , Citocinas/metabolismo , Células Hep G2 , Humanos , Interações Hidrofóbicas e Hidrofílicas , Fígado/metabolismo , Testes de Mutagenicidade , Tamanho da Partícula , Ureia
5.
Arch Toxicol ; 95(1): 321-336, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32910239

RESUMO

Current in vitro genotoxicity tests can produce misleading positive results, indicating an inability to effectively predict a compound's subsequent carcinogenic potential in vivo. Such oversensitivity can incur unnecessary in vivo tests to further investigate positive in vitro results, supporting the need to improve in vitro tests to better inform risk assessment. It is increasingly acknowledged that more informative in vitro tests using multiple endpoints may support the correct identification of carcinogenic potential. The present study, therefore, employed a holistic, multiple-endpoint approach using low doses of selected carcinogens and non-carcinogens (0.001-770 µM) to assess whether these chemicals caused perturbations in molecular and cellular endpoints relating to the Hallmarks of Cancer. Endpoints included micronucleus induction, alterations in gene expression, cell cycle dynamics, cell morphology and bioenergetics in the human lymphoblastoid cell line TK6. Carcinogens ochratoxin A and oestradiol produced greater Integrated Signature of Carcinogenicity scores for the combined endpoints than the "misleading" in vitro positive compounds, quercetin, 2,4-dichlorophenol and quinacrine dihydrochloride and toxic non-carcinogens, caffeine, cycloheximide and phenformin HCl. This study provides compelling evidence that carcinogens can successfully be distinguished from non-carcinogens using a holistic in vitro test system. Avoidance of misleading in vitro outcomes could lead to the reduction and replacement of animals in carcinogenicity testing.


Assuntos
Testes de Carcinogenicidade , Carcinógenos/toxicidade , Determinação de Ponto Final , Projetos de Pesquisa , Pontos de Checagem do Ciclo Celular/efeitos dos fármacos , Linhagem Celular , Forma Celular/efeitos dos fármacos , Metabolismo Energético/efeitos dos fármacos , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Micronúcleos com Defeito Cromossômico/induzido quimicamente , Testes para Micronúcleos , Fosforilação , Medição de Risco , Proteína Supressora de Tumor p53/metabolismo
6.
Small ; 16(36): e2002002, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32755066

RESUMO

To elucidate the impact of human exposure to engineered nanomaterials, advanced in vitro models are a valid non-animal alternative. Despite significant gains over the last decade, implementation of these approaches remains limited. This work discusses the current state-of-the-art and how future developments can lead to advanced in vitro models better supporting nano-hazard assessment.


Assuntos
Exposição Ambiental , Nanoestruturas , Comportamento de Redução do Risco , Exposição Ambiental/prevenção & controle , Humanos , Modelos Biológicos , Nanoestruturas/toxicidade , Medição de Risco
7.
Chem Res Toxicol ; 33(5): 1061-1073, 2020 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-32307980

RESUMO

Human exposure to engineered nanomaterials (ENMs) is inevitable due to the plethora of applications for which they are being manufactured and integrated within. ENMs demonstrate plentiful advantages in terms of industrial approaches as well as from a consumer perspective. However, despite such positives, doubts remain over the human health implications of ENM exposure. In light of the increased research focus upon the potential effects of ENM exposure to human health in recent decades, questions still remain regarding the safety of these highly advanced, precision-tuned physical entities. The risk of short-term, high-dose exposure to humans is considered relatively low, although this has formed the direction of the hazard-assessment community since the turn of the 21st century. However, the possibility of humans being exposed repeatedly over a long period of time to a low-dose of ENMs of varying physicochemical characteristics is of significant concern, and thus, industry, government, academic, and consumer agencies are only now beginning to consider this. Notably, when considering the human health implications of such low-dose, long-term, repeated exposure scenarios, the impact of ENMs upon the human immune system is of primary importance. However, there remains a real need to understand the impact of ENMs upon the human immune system, especially the innate immune system, at all stages of life, given exposure to nanosized particles begins before birth, that is, of the fetus. Therefore, the purpose of this perspective is to summarize what is currently known regarding ENM exposure of different components of the innate immune system and identify knowledge gaps that should be addressed if we are to fully deduce the impact of ENM exposure on innate immune function.


Assuntos
Imunidade Inata/efeitos dos fármacos , Nanoestruturas/efeitos adversos , Humanos
8.
Mutagenesis ; 33(4): 283-289, 2018 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-30204902

RESUMO

Use of imaging flow cytometry to assess induced DNA damage via the cytokinesis block micronucleus (CBMN) assay has thus far been limited to radiation dosimetry in human lymphocytes using high end, 'ImageStream X' series imaging cytometers. Its potential to enumerate chemically induced DNA damage using in vitro cell lines remains unexplored. In the present manuscript, we investigate the more affordable FlowSight® imaging cytometry platform to assess in vitro micronucleus (MN) induction in the human lymphoblastoid TK6 and metabolically competent MCL-5 cells treated with Methyl Methane Sulfonate (MMS) (0-5 µg/ml), Carbendazim (0-1.6 µg/ml), and Benzo[a]Pyrene (B[a]P) (0-6.3 µg/ml) for a period of 1.5-2 cell-cycles. Cells were fixed, and nuclei and MN were stained using the fluorescent nuclear dye DRAQ5™. Image acquisition was carried out using a 20X objective on a FlowSight® imaging cytometer (Amnis, part of Merck Millipore) equipped with a 488 nm laser. Populations of ∼20000 brightfield cell images, alongside DRAQ5™ stained nuclei/MN were rapidly collected (≤10 min). Single, in-focus cells suitable for scoring were then isolated using the IDEAS® software. An overlay of the brightfield cell outlines and the DRAQ5 nuclear fluorescence was used to facilitate scoring of mono-, bi-, tri-, and tetra-nucleated cells with or without MN events and in context of the cytoplasmic boundary of the parent cell.To establish the potential of the FlowSight® platform, and to establish 'ground truth' cell classification for the supervised machine learning based scoring algorithm that represents the next stage of our project, the captured images were scored manually. Alongside, MN frequencies were also derived using the 'gold standard' light microscopy and manual scoring. A minimum of 3000 bi-nucleated cells were assessed using both approaches. Using the benchmark dose approach, the comparability of genotoxic potency estimations for the different compounds and cell lines was assessed across the two scoring platforms as highly similar. This study therefore provides essential proof-of-concept that FlowSight® imaging cytometry is capable of reproducing the results of 'gold standard' manual scoring by light microscopy. We conclude that, with the right automated scoring algorithm, imaging flow cytometry could revolutionise the reportability and scoring throughput of the CBMN assay.


Assuntos
Citometria de Fluxo/métodos , Linfócitos/fisiologia , Testes para Micronúcleos/métodos , Benzimidazóis/farmacologia , Carbamatos/farmacologia , Linhagem Celular , Núcleo Celular/fisiologia , Citocinese/fisiologia , Dano ao DNA/fisiologia , Humanos , Metanossulfonato de Metila/farmacologia , Mutagênicos/farmacologia
9.
Arch Toxicol ; 92(2): 935-951, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29110037

RESUMO

Human exposure to carcinogens occurs via a plethora of environmental sources, with 70-90% of cancers caused by extrinsic factors. Aberrant phenotypes induced by such carcinogenic agents may provide universal biomarkers for cancer causation. Both current in vitro genotoxicity tests and the animal-testing paradigm in human cancer risk assessment fail to accurately represent and predict whether a chemical causes human carcinogenesis. The study aimed to establish whether the integrated analysis of multiple cellular endpoints related to the Hallmarks of Cancer could advance in vitro carcinogenicity assessment. Human lymphoblastoid cells (TK6, MCL-5) were treated for either 4 or 23 h with 8 known in vivo carcinogens, with doses up to 50% Relative Population Doubling (maximum 66.6 mM). The adverse effects of carcinogens on wide-ranging aspects of cellular health were quantified using several approaches; these included chromosome damage, cell signalling, cell morphology, cell-cycle dynamics and bioenergetic perturbations. Cell morphology and gene expression alterations proved particularly sensitive for environmental carcinogen identification. Composite scores for the carcinogens' adverse effects revealed that this approach could identify both DNA-reactive and non-DNA reactive carcinogens in vitro. The richer datasets generated proved that the holistic evaluation of integrated phenotypic alterations is valuable for effective in vitro risk assessment, while also supporting animal test replacement. Crucially, the study offers valuable insights into the mechanisms of human carcinogenesis resulting from exposure to chemicals that humans are likely to encounter in their environment. Such an understanding of cancer induction via environmental agents is essential for cancer prevention.


Assuntos
Testes de Carcinogenicidade/métodos , Carcinógenos/toxicidade , Linfócitos/efeitos dos fármacos , Mutagênicos/toxicidade , Linhagem Celular , Humanos , Testes para Micronúcleos , Análise de Sequência com Séries de Oligonucleotídeos , RNA Mensageiro/genética , Proteína Supressora de Tumor p53/metabolismo
10.
Mutagenesis ; 32(1): 233-241, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27815329

RESUMO

With the need to understand the potential biological impact of the plethora of nanoparticles (NPs) being manufactured for a wide range of potential human applications, due to their inevitable human exposure, research activities in the field of NP toxicology has grown exponentially over the last decade. Whilst such increased research efforts have elucidated an increasingly significant knowledge base pertaining to the potential human health hazard posed by NPs, understanding regarding the possibility for NPs to elicit genotoxicity is limited. In vivo models are unable to adequately discriminate between the specific modes of action associated with the onset of genotoxicity. Additionally, in line with the recent European directives, there is an inherent need to move away from invasive animal testing strategies. Thus, in vitro systems are an important tool for expanding our mechanistic insight into NP genotoxicity. Yet uncertainty remains concerning their validity and specificity for this purpose due to the unique challenges presented when correlating NP behaviour in vitro and in vivo This review therefore highlights the current state of the art in advanced in vitro systems and their specific advantages and disadvantages from a NP genotoxicity testing perspective. Key indicators will be given related to how these systems might be used or improved to enhance understanding of NP genotoxicity.


Assuntos
Dano ao DNA , Testes de Mutagenicidade/métodos , Nanopartículas/toxicidade , Animais , DNA/efeitos dos fármacos , Humanos
11.
J Nanobiotechnology ; 15(1): 45, 2017 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-28619032

RESUMO

BACKGROUND: Nanoparticle interactions with cellular membranes and the kinetics of their transport and localization are important determinants of their functionality and their biological consequences. Understanding these phenomena is fundamental for the translation of such NPs from in vitro to in vivo systems for bioimaging and medical applications. Two CdSe/ZnS quantum dots (QD) with differing surface functionality (NH2 or COOH moieties) were used here for investigating the intracellular uptake and transport kinetics of these QDs. RESULTS: In water, the COOH- and NH2-QDs were negatively and positively charged, respectively, while in serum-containing medium the NH2-QDs were agglomerated, whereas the COOH-QDs remained dispersed. Though intracellular levels of NH2- and COOH-QDs were very similar after 24 h exposure, COOH-QDs appeared to be continuously internalised and transported by endosomes and lysosomes, while NH2-QDs mainly remained in the lysosomes. The results of (intra)cellular QD trafficking were correlated to their toxicity profiles investigating levels of reactive oxygen species (ROS), mitochondrial ROS, autophagy, changes to cellular morphology and alterations in genes involved in cellular stress, toxicity and cytoskeletal integrity. The continuous flux of COOH-QDs perhaps explains their higher toxicity compared to the NH2-QDs, mainly resulting in mitochondrial ROS and cytoskeletal remodelling which are phenomena that occur early during cellular exposure. CONCLUSIONS: Together, these data reveal that although cellular QD levels were similar after 24 h, differences in the nature and extent of their cellular trafficking resulted in differences in consequent gene alterations and toxicological effects.


Assuntos
Autofagia/efeitos dos fármacos , Compostos de Cádmio/toxicidade , Pontos Quânticos/toxicidade , Espécies Reativas de Oxigênio/metabolismo , Compostos de Selênio/toxicidade , Sulfetos/toxicidade , Compostos de Zinco/toxicidade , Compostos de Cádmio/análise , Compostos de Cádmio/metabolismo , Linhagem Celular , Regulação da Expressão Gênica/efeitos dos fármacos , Humanos , Lisossomos/efeitos dos fármacos , Lisossomos/metabolismo , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Pontos Quânticos/análise , Pontos Quânticos/metabolismo , Compostos de Selênio/análise , Compostos de Selênio/metabolismo , Sulfetos/análise , Sulfetos/metabolismo , Compostos de Zinco/análise , Compostos de Zinco/metabolismo
12.
Arch Toxicol ; 91(7): 2689-2698, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27942789

RESUMO

The use of manual microscopy for the scoring of chromosome damage in the in vitro micronucleus assay is often associated with user subjectivity. This level of subjectivity can be reduced by using automated platforms, which have added value of faster with high-throughput and multi-endpoint capabilities. However, there is a need to assess the reproducibility and sensitivity of these automated platforms compared with the gold standard of the manual scoring. The automated flow cytometry-based MicroFlow® and image analysis-based Metafer™ were used for dose response analyses in human lymphoblastoid TK6 cells exposed to the model clastogen, methyl methanesulfonate (MMS), aneugen, carbendazim, and the weak genotoxic carcinogen, ochratoxin A (OTA). Cells were treated for 4 or 30 h, with a 26- or 0-h recovery. Flow cytometry scoring parameters and the Metafer™ image classifier were investigated, to assess any potential differences in the micronucleus (MN) dose responses. Dose response data were assessed using the benchmark dose approach with chemical and scoring system set as covariate to assess reproducibility between endpoints. A clear increase in MN frequency was observed using the MicroFlow® approach on TK6 cells treated for 30 h with MMS, carbendazim and OTA. The MicroFlow®-based MN frequencies were comparable to those derived by using the Metafer™ and manual scoring platforms. However, there was a potential overscoring of MN with the MicroFlow® due to the cell lysis step and an underscoring with the Metafer™ system based on current image classifier settings. The findings clearly demonstrate that the MicroFlow® and Metafer™ MN scoring platforms are powerful tools for automated high-throughput MN scoring and dose response analysis.


Assuntos
Relação Dose-Resposta a Droga , Testes para Micronúcleos/instrumentação , Testes para Micronúcleos/métodos , Automação , Benzimidazóis/toxicidade , Carbamatos/toxicidade , Linhagem Celular , Núcleo Celular/efeitos dos fármacos , Núcleo Celular/genética , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Humanos , Metanossulfonato de Metila/toxicidade , Mutagênicos/toxicidade , Ocratoxinas/toxicidade , Reprodutibilidade dos Testes
13.
Mutagenesis ; 31(1): 97-106, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26275419

RESUMO

Quantum dots (QD) have unique electronic and optical properties promoting biotechnological advances. However, our understanding of the toxicological structure-activity relationships remains limited. This study aimed to determine the biological impact of varying nanomaterial surface chemistry by assessing the interaction of QD with either a negative (carboxyl), neutral (hexadecylamine; HDA) or positive (amine) polymer coating with human lymphoblastoid TK6 cells. Following QD physico-chemical characterisation, cellular uptake was quantified by optical and electron microscopy. Cytotoxicity was evaluated and genotoxicity was characterised using the micronucleus assay (gross chromosomal damage) and the HPRT forward mutation assay (point mutagenicity). Cellular damage mechanisms were also explored, focusing on oxidative stress and mitochondrial damage. Cell uptake, cytotoxicity and genotoxicity were found to be dependent on QD surface chemistry. Carboxyl-QD demonstrated the smallest agglomerate size and greatest cellular uptake, which correlated with a dose dependent increase in cytotoxicity and genotoxicity. Amine-QD induced minimal cellular damage, while HDA-QD promoted substantial induction of cell death and genotoxicity. However, HDA-QD were not internalised by the cells and the damage they caused was most likely due to free cadmium release caused by QD dissolution. Oxidative stress and induced mitochondrial reactive oxygen species were only partially associated with cytotoxicity and genotoxicity induced by the QD, hence were not the only mechanisms of importance. Colloidal stability, nanoparticle (NP) surface chemistry, cellular uptake levels and the intrinsic characteristics of the NPs are therefore critical parameters impacting genotoxicity induced by QD.


Assuntos
Dano ao DNA , Mutagênicos/farmacologia , Estresse Oxidativo , Pontos Quânticos/toxicidade , Semicondutores , Cádmio/farmacologia , Linhagem Celular , Humanos , Linfócitos/efeitos dos fármacos , Testes de Mutagenicidade , Pontos Quânticos/química , Selênio/farmacologia , Relação Estrutura-Atividade , Propriedades de Superfície
14.
Mutagenesis ; 31(2): 171-80, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26362870

RESUMO

4-Nitroquinoline 1-oxide (4NQO) is used as a positive control in various genotoxicity assays because of its known mutagenic and carcinogenic properties. The chemical is converted into 4-hydroxyaminoquinoline 1-oxide and gives rise to three main DNA adducts, N-(deoxyguanosin-8-yl)-4AQO, 3-(desoxyguanosin-N (2)-yl)-4AQO and 3-(deoxyadenosin-N (6)-yl)-4AQO. This study was designed to assess the shape of the dose-response curve at low concentrations of 4NQO in three human lymphoblastoid cell lines, MCL-5, AHH-1 and TK6 as well as the mouse lymphoma L5178Y cell line in vitro. Chromosomal damage was investigated using the in vitro micronucleus assay, while further gene mutation and DNA damage studies were carried out using the hypoxanthine-guanine phosphoribosyltransferase forward mutation and comet assays. 4NQO showed little to no significant increases in micronucleus induction in the human lymphoblastoid cell lines, even up to 55±5% toxicity. A dose-response relationship could only be observed in the mouse lymphoma cell line L5178Y after 4NQO treatment, even at concentrations with no reduction in cell viability. Further significant increases in gene mutation and DNA damage induction were observed. Hence, 4NQO is a more effective point mutagen than clastogen, and its suitability as a positive control for genotoxicity testing has to be evaluated for every individual assay.


Assuntos
4-Nitroquinolina-1-Óxido/toxicidade , Carcinógenos/toxicidade , Mutagênicos/toxicidade , Proteína Supressora de Tumor p53/genética , Animais , Linhagem Celular Tumoral , Aberrações Cromossômicas/induzido quimicamente , Ensaio Cometa , Dano ao DNA/efeitos dos fármacos , Relação Dose-Resposta a Droga , Humanos , Hipoxantina Fosforribosiltransferase/genética , Camundongos , Testes para Micronúcleos , Testes de Mutagenicidade , Mutação/efeitos dos fármacos
15.
Part Fibre Toxicol ; 13(1): 50, 2016 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-27613375

RESUMO

BACKGROUND: The rapid production and incorporation of engineered nanomaterials into consumer products alongside research suggesting nanomaterials can cause cell death and DNA damage (genotoxicity) makes in vitro assays desirable for nanosafety screening. However, conflicting outcomes are often observed when in vitro and in vivo study results are compared, suggesting more physiologically representative in vitro models are required to minimise reliance on animal testing. METHOD: BASF Levasil® silica nanoparticles (16 and 85 nm) were used to adapt the 3D reconstructed skin micronucleus (RSMN) assay for nanomaterials administered topically or into the growth medium. 3D dose-responses were compared to a 2D micronucleus assay using monocultured human B cells (TK6) after standardising dose between 2D / 3D assays by total nanoparticle mass to cell number. Cryogenic vitrification, scanning electron microscopy and dynamic light scattering techniques were applied to characterise in-medium and air-liquid interface exposures. Advanced transmission electron microscopy imaging modes (high angle annular dark field) and X-ray spectrometry were used to define nanoparticle penetration / cellular uptake in the intact 3D models and 2D monocultured cells. RESULTS: For all 2D exposures, significant (p < 0.002) increases in genotoxicity were observed (≥100 µg/mL) alongside cell viability decreases (p < 0.015) at doses ≥200 µg/mL (16 nm-SiO2) and ≥100 µg/mL (85 nm-SiO2). In contrast, 2D-equivalent exposures to the 3D models (≤300 µg/mL) caused no significant DNA damage or impact on cell viability. Further increasing dose to the 3D models led to probable air-liquid interface suffocation. Nanoparticle penetration / cell uptake analysis revealed no exposure to the live cells of the 3D model occurred due to the protective nature of the skin model's 3D cellular microarchitecture (topical exposures) and confounding barrier effects of the collagen cell attachment layer (in-medium exposures). 2D monocultured cells meanwhile showed extensive internalisation of both silica particles causing (geno)toxicity. CONCLUSIONS: The results establish the importance of tissue microarchitecture in defining nanomaterial exposure, and suggest 3D in vitro models could play a role in bridging the gap between in vitro and in vivo outcomes in nanotoxicology. Robust exposure characterisation and uptake assessment methods (as demonstrated) are essential to interpret nano(geno)toxicity studies successfully.


Assuntos
Testes para Micronúcleos , Modelos Biológicos , Nanopartículas/toxicidade , Pele/efeitos dos fármacos , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Transmissão
16.
Mutagenesis ; 29(3): 155-64, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24705543

RESUMO

Micronucleus (MN) induction is an established cytogenetic end point for evaluating structural and numerical chromosomal alterations in genotoxicity testing. A semi-automated scoring protocol for the assessment of MN preparations from human cell lines and a 3D skin cell model has been developed and validated. Following exposure to a range of test agents, slides were stained with 4'-6-diamidino-2-phenylindole (DAPI) and scanned by use of the MicroNuc module of metafer 4, after the development of a modified classifier for selecting MN in binucleate cells. A common difficulty observed with automated systems is an artefactual output of high false positives, in the case of the metafer system this is mainly due to the loss of cytoplasmic boundaries during slide preparation. Slide quality is paramount to obtain accurate results. We show here that to avoid elevated artefactual-positive MN outputs, diffuse cell density and low-intensity nuclear staining are critical. Comparisons between visual (Giemsa stained) and automated (DAPI stained) MN frequencies and dose-response curves were highly correlated (R (2) = 0.70 for hydrogen peroxide, R (2) = 0.98 for menadione, R (2) = 0.99 for mitomycin C, R (2) = 0.89 for potassium bromate and R (2) = 0.68 for quantum dots), indicating the system is adequate to produce biologically relevant and reliable results. Metafer offers many advantages over conventional scoring including increased output and statistical power, and reduced scoring subjectivity, labour and costs. Further, the metafer system is easily adaptable for use with a range of different cells, both suspension and adherent human cell lines. Awareness of the points raised here reduces the automatic positive errors flagged and drastically reduces slide scoring time, making metafer an ideal candidate for genotoxic biomonitoring and population studies and regulatory genotoxic testing.


Assuntos
Testes para Micronúcleos/métodos , Técnicas de Cultura de Células , Linhagem Celular , Quebra Cromossômica/efeitos dos fármacos , Corantes Fluorescentes , Humanos , Indóis , Queratinócitos/efeitos dos fármacos , Queratinócitos/patologia , Micronúcleos com Defeito Cromossômico/efeitos dos fármacos , Testes para Micronúcleos/estatística & dados numéricos , Mutagênicos/toxicidade
17.
Nanotoxicology ; 16(1): 52-72, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35085458

RESUMO

Human ENP exposure is inevitable and the novel, size-dependent physicochemical properties that enable ENPs to be beneficial in innovative technologies are concomitantly causing heightened public concerns as to their potential adverse effects upon human health. This study aims to deduce the mechanisms associated with potential ENP mediated (geno)toxicity and impact upon telomere integrity, if any, of varying concentrations of both ∼16 nm (4.34 × 10-3 to 17.36 × 10-3 mg/mL) Gold (Au) and ∼14 nm (0.85 × 10-5 to 3.32 × 10-5 mg/mL) Silver (Ag) ENPs upon two commonly used lung epithelial cell lines, 16HBE14o- and A549. Following cytotoxicity analysis (via Trypan Blue and Lactate Dehydrogenase assay), two sub-lethal concentrations were selected for genotoxicity analysis using the cytokinesis-blocked micronucleus assay. Whilst both ENP types induced significant oxidative stress, Ag ENPs (1.66 × 10-5 mg/mL) did not display a significant genotoxic response in either epithelial cell lines, but Au ENPs (8.68 × 10-3 mg/mL) showed a highly significant 2.63-fold and 2.4-fold increase in micronucleus frequency in A549 and 16HBE14o- cells respectively. It is hypothesized that the DNA damage induced by acute 24-h Au ENP exposure resulted in a cell cycle stall indicated by the increased mononuclear cell fraction (>6.0-fold) and cytostasis level. Albeit insignificant, a small reduction in telomere length was observed following acute exposure to both ENPs which could indicate the potential for ENP mediated telomere attrition. Finally, from the data shown, both in vitro lung cell cultures (16HBE14o- and A549) are equally as suitable and reliable for the in vitro ENP hazard identification approach adopted in this study.


Assuntos
Nanopartículas Metálicas , Nanopartículas , Dano ao DNA , Células Epiteliais , Ouro/química , Humanos , Pulmão/química , Nanopartículas Metálicas/química , Nanopartículas Metálicas/toxicidade , Nanopartículas/toxicidade , Prata/química
18.
Toxicol In Vitro ; 85: 105473, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36108805

RESUMO

To reduce, replace, and refine in vivo testing, there is increasing emphasis on the development of more physiologically relevant in vitro test systems to improve the reliability of non-animal-based methods for hazard assessment. When developing new approach methodologies, it is important to standardize the protocols and demonstrate the methods can be reproduced by multiple laboratories. The aim of this study was to assess the transferability and reproducibility of two advanced in vitro liver models, the Primary Human multicellular microtissue liver model (PHH) and the 3D HepG2 Spheroid Model, for nanomaterial (NM) and chemical hazard assessment purposes. The PHH model inter-laboratory trial showed strong consistency across the testing sites. All laboratories evaluated cytokine release and cytotoxicity following exposure to titanium dioxide (TiO2) and zinc oxide (ZnO) nanoparticles. No significant difference was observed in cytotoxicity or IL-8 release for the test materials. The data were reproducible with all three laboratories with control readouts within a similar range. The PHH model ZnO induced the greatest cytotoxicity response at 50.0 µg/mL and a dose-dependent increase in IL-8 release. For the 3D HepG2 spheroid model, all test sites were able to construct the model and demonstrated good concordance in IL-8 cytokine release and genotoxicity data. This trial demonstrates the successful transfer of new approach methodologies across multiple laboratories, with good reproducibility for several hazard endpoints.


Assuntos
Óxido de Zinco , Humanos , Óxido de Zinco/toxicidade , Reprodutibilidade dos Testes , Interleucina-8 , Fígado , Linhagem Celular , Esferoides Celulares
19.
Anal Chem ; 83(10): 3778-85, 2011 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-21469681

RESUMO

Due to the unique physicochemical properties of nanomaterials (NM) and their unknown reactivity, the possibility of NM altering the optical properties of fluorometric/colorimetric probes that are used to measure their cyto- and genotoxicity may lead to inaccurate readings. This could have potential implications given that NM, such as ultrafine superparamagnetic iron oxide nanoparticles (USPION), are increasingly finding their use in nanomedicine and the absorbance/fluorescence based assays are used to assess their toxicity. This study looks at the potential of dextran-coated USPION (dUSPION) (maghemite and magnetite) to alter the background signal of common probes used for evaluating cytotoxicity (MTS, CyQUANT, Calcein, and EthD-1) and oxidative stress (DCFH-DA and APF). In the present study, both forms of dUSPION caused an increase in MTS signal but a decrease in background signal from calcein and 3'-(p-aminophenyl) fluorescein (APF) and no effect on CyQUANT and EthD-1 fluorescence responses. Magnetite caused a decrease in fluorescence signal of DCFH, but it did not decrease fluorescence signal in the presence of the reactive oxygen species-inducer tert-butyl hydroperoxide (TBHP). In contrast, maghemite caused an increase in fluorescence, which was substantially reduced in the presence of the antioxidant N-acetyl cysteine. This study emphasizes the importance of considering and controlling for possible interactions between NM and fluorometric/colorimetric dyes and, most importantly, the oxidation state of dUSPION that may confound their sensitivity and specificity.


Assuntos
Colorimetria/métodos , Corantes/química , Dextranos/química , Compostos Férricos/química , Corantes Fluorescentes/química , Fluorometria/métodos , Nanopartículas de Magnetita/química , Etídio/análogos & derivados , Etídio/toxicidade , Fluoresceínas/toxicidade , Espécies Reativas de Oxigênio/metabolismo , terc-Butil Hidroperóxido/química
20.
Toxicol In Vitro ; 67: 104905, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32497684

RESUMO

Genotoxicity testing methods in vitro provide a means to predict the DNA damaging effects of chemicals on human cells. This is hindered in the case of hydrophobic test compounds, however, which will partition to in vitro components such as plastic-ware and medium proteins, in preference to the aqueous phase of the exposure medium. This affects the freely available test chemical concentration, and as this freely dissolved aqueous concentration is that bioavailable to cells, it is important to define and maintain this exposure. Passive dosing promises to have an advantage over traditional 'solvent spiking' exposure methods and involves the establishment and maintenance of known chemical concentrations in the in vitro medium, and therefore aqueous phase. Passive dosing was applied in a novel format to expose the MCL-5 human lymphoblastoid cell line to the pro-carcinogen, benzo[a]pyrene (B[a]P) and was compared to solvent (dimethyl sulphoxide) spiked B[a]P exposures over 48 h. Passive dosing induced greater changes, at lower concentrations, to micronucleus frequency, p21 mRNA expression, cell cycle abnormalities, and cell and nuclear morphology. This was attributed to a maintained, definable, free chemical concentration using passive dosing and the presence or absence of solvent, and highlights the influence of exposure choice on genotoxic outcomes.


Assuntos
Carcinógenos/administração & dosagem , Dimetil Sulfóxido/administração & dosagem , Solventes/administração & dosagem , Benzo(a)pireno/administração & dosagem , Benzo(a)pireno/toxicidade , Carcinógenos/toxicidade , Ciclo Celular/efeitos dos fármacos , Linhagem Celular , Dano ao DNA , Dimetil Sulfóxido/toxicidade , Humanos , Testes para Micronúcleos , Solventes/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA