Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Dis Child Fetal Neonatal Ed ; 97(5): F365-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22933096

RESUMO

INTRODUCTION: Therapeutic hypothermia is a time critical intervention for infants who have experienced a hypoxic-ischaemic event. Previously reported methods of cooling during transport do not demonstrate the same stability achieved in the neonatal unit. The authors developed a system which allowed provision of servo-controlled cooling throughout transport, and present their first year's experience. METHODS: Retrospective review of routinely collected patient data. RESULTS: 14 out-born infants were referred for cooling during a 12-month period. Nine infants were managed with the servo-controlled system during transport. Cooling was commenced in all infants before 6 h of life. Median time from team arrival to the infant having a temperature in the target range (33-34°C) was 45 min. Median temperature during transfer was 33.5°C (range 33-34°C). Temperature on arrival at the cooling centre ranged from 33.4°C to 33.8°C. CONCLUSION: Servo-controlled cooling during transport is feasible and provides an optimal level of thermal control.


Assuntos
Hipotermia Induzida/métodos , Hipóxia-Isquemia Encefálica/terapia , Transferência de Pacientes , Humanos , Hipotermia Induzida/instrumentação , Recém-Nascido , Masculino , Estudos Retrospectivos
2.
Arch Dis Child Fetal Neonatal Ed ; 96(6): F429-33, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21378398

RESUMO

BACKGROUND: A pretrial clinical improvement project for the BOOST-II UK trial of oxygen saturation targeting revealed an artefact affecting saturation profiles obtained from the Masimo Set Radical pulse oximeter. METHODS: Saturation was recorded every 10 s for up to 2 weeks in 176 oxygen dependent preterm infants in 35 UK and Irish neonatal units between August 2006 and April 2009 using Masimo SET Radical pulse oximeters. Frequency distributions of % time at each saturation were plotted. An artefact affecting the saturation distribution was found to be attributable to the oximeter's internal calibration algorithm. Revised software was installed and saturation distributions obtained were compared with four other current oximeters in paired studies. RESULTS: There was a reduction in saturation values of 87-90%. Values above 87% were elevated by up to 2%, giving a relative excess of higher values. The software revision eliminated this, improving the distribution of saturation values. In paired comparisons with four current commercially available oximeters, Masimo oximeters with the revised software returned similar saturation distributions. CONCLUSIONS: A characteristic of the software algorithm reduces the frequency of saturations of 87-90% and increases the frequency of higher values returned by the Masimo SET Radical pulse oximeter. This effect, which remains within the recommended standards for accuracy, is removed by installing revised software (board firmware V4.8 or higher). Because this observation is likely to influence oxygen targeting, it should be considered in the analysis of the oxygen trial results to maximise their generalisability.


Assuntos
Recém-Nascido Prematuro/sangue , Oximetria/instrumentação , Oxigenoterapia/métodos , Oxigênio/sangue , Algoritmos , Artefatos , Calibragem , Humanos , Recém-Nascido , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Oximetria/métodos , Oximetria/normas , Reprodutibilidade dos Testes , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA