Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Breast Cancer Res ; 14(3): R94, 2012 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-22697607

RESUMO

INTRODUCTION: The purpose of this study was to compare the diagnostic accuracy of dual-energy contrast-enhanced digital mammography (CEDM) as an adjunct to mammography (MX) ± ultrasonography (US) with the diagnostic accuracy of MX ± US alone. METHODS: One hundred ten consenting women with 148 breast lesions (84 malignant, 64 benign) underwent two-view dual-energy CEDM in addition to MX and US using a specially modified digital mammography system (Senographe DS, GE Healthcare). Reference standard was histology for 138 lesions and follow-up for 12 lesions. Six radiologists from 4 institutions interpreted the images using high-resolution softcopy workstations. Confidence of presence (5-point scale), probability of cancer (7-point scale), and BI-RADS scores were evaluated for each finding. Sensitivity, specificity and ROC curve areas were estimated for each reader and overall. Visibility of findings on MX ± CEDM and MX ± US was evaluated with a Likert scale. RESULTS: The average per-lesion sensitivity across all readers was significantly higher for MX ± US ± CEDM than for MX ± US (0.78 vs. 0.71 using BIRADS, p = 0.006). All readers improved their clinical performance and the average area under the ROC curve was significantly superior for MX ± US ± CEDM than for MX ± US ((0.87 vs 0.83, p = 0.045). Finding visibility was similar or better on MX ± CEDM than MX ± US in 80% of cases. CONCLUSIONS: Dual-energy contrast-enhanced digital mammography as an adjunct to MX ± US improves diagnostic accuracy compared to MX ± US alone. Addition of iodinated contrast agent to MX facilitates the visualization of breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Ultrassonografia Mamária/métodos , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica
3.
JAMA ; 307(13): 1394-404, 2012 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-22474203

RESUMO

CONTEXT: Annual ultrasound screening may detect small, node-negative breast cancers that are not seen on mammography. Magnetic resonance imaging (MRI) may reveal additional breast cancers missed by both mammography and ultrasound screening. OBJECTIVE: To determine supplemental cancer detection yield of ultrasound and MRI in women at elevated risk for breast cancer. DESIGN, SETTING, AND PARTICIPANTS: From April 2004-February 2006, 2809 women at 21 sites with elevated cancer risk and dense breasts consented to 3 annual independent screens with mammography and ultrasound in randomized order. After 3 rounds of both screenings, 612 of 703 women who chose to undergo an MRI had complete data. The reference standard was defined as a combination of pathology (biopsy results that showed in situ or infiltrating ductal carcinoma or infiltrating lobular carcinoma in the breast or axillary lymph nodes) and 12-month follow-up. MAIN OUTCOME MEASURES: Cancer detection rate (yield), sensitivity, specificity, positive predictive value (PPV3) of biopsies performed and interval cancer rate. RESULTS: A total of 2662 women underwent 7473 mammogram and ultrasound screenings, 110 of whom had 111 breast cancer events: 33 detected by mammography only, 32 by ultrasound only, 26 by both, and 9 by MRI after mammography plus ultrasound; 11 were not detected by any imaging screen. Among 4814 incidence screens in the second and third years combined, 75 women were diagnosed with cancer. Supplemental incidence-screening ultrasound identified 3.7 cancers per 1000 screens (95% CI, 2.1-5.8; P < .001). Sensitivity for mammography plus ultrasound was 0.76 (95% CI, 0.65-0.85); specificity, 0.84 (95% CI, 0.83-0.85); and PPV3, 0.16 (95% CI, 0.12-0.21). For mammography alone, sensitivity was 0.52 (95% CI, 0.40-0.64); specificity, 0.91 (95% CI, 0.90-0.92); and PPV3, 0.38 (95% CI, 0.28-0.49; P < .001 all comparisons). Of the MRI participants, 16 women (2.6%) had breast cancer diagnosed. The supplemental yield of MRI was 14.7 per 1000 (95% CI, 3.5-25.9; P = .004). Sensitivity for MRI and mammography plus ultrasound was 1.00 (95% CI, 0.79-1.00); specificity, 0.65 (95% CI, 0.61-0.69); and PPV3, 0.19 (95% CI, 0.11-0.29). For mammography and ultrasound, sensitivity was 0.44 (95% CI, 0.20-0.70, P = .004); specificity 0.84 (95% CI, 0.81-0.87; P < .001); and PPV3, 0.18 (95% CI, 0.08 to 0.34; P = .98). The number of screens needed to detect 1 cancer was 127 (95% CI, 99-167) for mammography; 234 (95% CI, 173-345) for supplemental ultrasound; and 68 (95% CI, 39-286) for MRI after negative mammography and ultrasound results. CONCLUSION: The addition of screening ultrasound or MRI to mammography in women at increased risk of breast cancer resulted in not only a higher cancer detection yield but also an increase in false-positive findings. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00072501.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Reações Falso-Positivas , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Ultrassonografia , Adulto Jovem
4.
Breast J ; 17(1): 9-17, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21251121

RESUMO

Although magnetic resonance imaging (MRI) is much more sensitive than mammography for detecting early invasive breast cancer, in many high-risk screening studies MRI was less sensitive than mammography for detecting ductal carcinoma in situ (DCIS). We reviewed our experience detecting DCIS in our single center study of annual MRI, mammography, ultrasound and clinical breast examination (CBE) for screening very high-risk women. All cases of DCIS±microinvasion and invasive cancer were compared in two time frames: before (period A) and after (period B) July 2001-when we acquired expertise in the detection of DCIS with MRI-with respect to patient demographics, method of detection, and rates of detection of invasive cancer and DCIS. In period A there were 15 cases (3.1% of 486 screens) in 223 women, of which 2 (13%) were DCIS-one with microinvasion-neither detected by MRI. In period B there were 29 cases (3.3% of 877 screens) in 391 women, of which 10 (34%) were DCIS±microinvasion (p=0.04), all 10 detected by MRI but only one by mammography. No DCIS cases were detected by ultrasound or CBE. Specificity was lower in period B than in period A but acceptable. The ability to detect DCIS with screening MRI improves significantly with experience. MRI-guided biopsy capability is essential for a high-risk screening program. In experienced centers the increased sensitivity of MRI relative to mammography is at least as high for DCIS as it is for invasive breast cancer.


Assuntos
Neoplasias da Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Neoplasias da Mama/genética , Carcinoma Intraductal não Infiltrante/genética , Feminino , Genes BRCA1 , Genes BRCA2 , Predisposição Genética para Doença , Heterozigoto , Humanos , Mamografia , Pessoa de Meia-Idade , Mutação , Invasividade Neoplásica , Exame Físico , Estudos Retrospectivos , Medição de Risco , Ultrassonografia
5.
N Engl J Med ; 356(3): 227-36, 2007 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-17229950

RESUMO

BACKGROUND: Extensive mammographic density is associated with an increased risk of breast cancer and makes the detection of cancer by mammography difficult, but the influence of density on risk according to method of cancer detection is unknown. METHODS: We carried out three nested case-control studies in screened populations with 1112 matched case-control pairs. We examined the association of the measured percentage of density in the baseline mammogram with risk of breast cancer, according to method of cancer detection, time since the initiation of screening, and age. RESULTS: As compared with women with density in less than 10% of the mammogram, women with density in 75% or more had an increased risk of breast cancer (odds ratio, 4.7; 95% confidence interval [CI], 3.0 to 7.4), whether detected by screening (odds ratio, 3.5; 95% CI, 2.0 to 6.2) or less than 12 months after a negative screening examination (odds ratio, 17.8; 95% CI, 4.8 to 65.9). Increased risk of breast cancer, whether detected by screening or other means, persisted for at least 8 years after study entry and was greater in younger than in older women. For women younger than the median age of 56 years, 26% of all breast cancers and 50% of cancers detected less than 12 months after a negative screening test were attributable to density in 50% or more of the mammogram. CONCLUSIONS: Extensive mammographic density is strongly associated with the risk of breast cancer detected by screening or between screening tests. A substantial fraction of breast cancers can be attributed to this risk factor.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia , Adulto , Idoso , Mama/patologia , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Estudos de Casos e Controles , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Risco
6.
Radiology ; 254(1): 79-87, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20032143

RESUMO

PURPOSE: To determine reasons for nonparticipation in a trial of supplemental screening with magnetic resonance (MR) imaging after mammography and ultrasonography (US). MATERIALS AND METHODS: Women(n = 2809) at elevated risk of breast cancer were enrolled in the American College of Radiology Imaging Network 6666 US Screening Protocol at 21 institutions. Fourteen institutions met technical and experience requirements for this institutional review board-approved, HIPAA-compliant substudy of supplemental screening with MR imaging. Those women who had completed 0-, 12-, and 24-month screenings with mammography combined with US were considered for a single contrast material-enhanced MR examination within 8 weeks after completing the 24-month mammography-US screening. A total of 1593 women had complete MR substudy registration data: 378 of them were ineligible for the study, and 1215 had analyzable data. Reasons for nonparticipation were determined. Demographic data were compared between study participants and nonparticipants. RESULTS: Of 1215 women with analyzable data, 703 (57.9%), with a mean age of 54.8 years, were enrolled in the MR substudy and 512 (42.1%) declined participation. Women with a 25% or greater lifetime risk of breast cancer were more likely to participate (odds ratio, 1.53; 95% confidence interval: 1.10, 2.12). Of 512 nonparticipants, 130 (25.4%) refused owing to claustrophobia; 93 (18.2%), owing to time constraints; 62 (12.1%), owing to financial concerns; 47 (9.2%), because their physician would not provide a referral and/or did not believe MR imaging was indicated; 40 (7.8%), because they were not interested; 39 (7.6%), because they were medically intolerant to MR imaging; 29 (5.7%), because they did not want to undergo intravenous injection; 27 (5.3%), owing to additional biopsy or other procedures that might be required subsequently; 21 (4.1%), owing to MR imaging scheduling constraints; 11 (2.2%), because of the travel required; seven (1.4%), owing to gadolinium-related risks or allergies; and six (1.2%), for unknown reasons. CONCLUSION: Of 1215 women with elevated breast cancer risk who could, according to protocol guidelines, undergo breast MR imaging, only 57.9% agreed to participate.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/psicologia , Imageamento por Ressonância Magnética/psicologia , Programas de Rastreamento/métodos , Recusa do Paciente ao Tratamento/psicologia , Mulheres/psicologia , Meios de Contraste , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Fatores de Risco , Ultrassonografia Mamária , Estados Unidos
7.
Cancers (Basel) ; 12(11)2020 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-33238387

RESUMO

Annual breast magnetic resonance imaging (MRI) plus mammography is the standard of care for screening women with inherited BRCA1/2 mutations. However, long-term breast cancer-related mortality with screening is unknown. Between 1997 and June 2011, 489 previously unaffected BRCA1/2 mutation carriers aged 25 to 65 years were screened with annual MRI plus mammography on our study. Thereafter, participants were eligible to continue MRI screening through the high-risk Ontario Breast Screening Program. In 2019, our data were linked to the Ontario Cancer Registry of Cancer Care Ontario to identify all incident cancers, vital status and causes of death. Observed breast cancer mortality was compared to expected mortality for age-matched women in the general population. There were 91 women diagnosed with breast cancer (72 invasive and 19 ductal carcinoma in situ (DCIS)) with median follow-up 7.4 (range: 0.1 to 19.2) years. Four deaths from breast cancer were observed, compared to 2.0 deaths expected (standardized mortality ratio (SMR) 2.0, p = 0.14). For the 489 women in the study, the probability of not dying of breast cancer at 20 years from the date of the first MRI was 98.2%. Annual screening with MRI plus mammography is a reasonable option for women who decline or defer risk-reducing mastectomy.

8.
Radiology ; 252(2): 348-57, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19703878

RESUMO

PURPOSE: To determine which factors contributed to the Digital Mammographic Imaging Screening Trial (DMIST) cancer detection results. MATERIALS AND METHODS: This project was HIPAA compliant and institutional review board approved. Seven radiologist readers reviewed the film hard-copy (screen-film) and digital mammograms in DMIST cancer cases and assessed the factors that contributed to lesion visibility on both types of images. Two multinomial logistic regression models were used to analyze the combined and condensed visibility ratings assigned by the readers to the paired digital and screen-film images. RESULTS: Readers most frequently attributed differences in DMIST cancer visibility to variations in image contrast--not differences in positioning or compression--between digital and screen-film mammography. The odds of a cancer being more visible on a digital mammogram--rather than being equally visible on digital and screen-film mammograms--were significantly greater for women with dense breasts than for women with nondense breasts, even with the data adjusted for patient age, lesion type, and mammography system (odds ratio, 2.28; P < .0001). The odds of a cancer being more visible at digital mammography--rather than being equally visible at digital and screen-film mammography--were significantly greater for lesions imaged with the General Electric digital mammography system than for lesions imaged with the Fischer (P = .0070) and Fuji (P = .0070) devices. CONCLUSION: The significantly better diagnostic accuracy of digital mammography, as compared with screen-film mammography, in women with dense breasts demonstrated in the DMIST was most likely attributable to differences in image contrast, which were most likely due to the inherent system performance improvements that are available with digital mammography. The authors conclude that the DMIST results were attributable primarily to differences in the display and acquisition characteristics of the mammography devices rather than to reader variability.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia/métodos , Programas de Rastreamento/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Variações Dependentes do Observador , Análise de Regressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
9.
Med Phys ; 36(2): 577-86, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19291997

RESUMO

The determination of volumetric breast density (VBD) from mammograms requires an accurate knowledge of the thickness of the compressed breast. Previously, the authors described a technique for measuring local thicknesses using optical stereoscopic photogrammetry [A. H. Tyson, G. E. Mawdsley, and M. J. Yaffe, "Measurement of compressed breast thickness by optical stereoscopic photogrammetry," Med. Phys. 36(2), 569-576 (2009)]. Here, the authors describe the use of this tool to guide the development of a simpler, more practical field technique for the estimation of breast thickness and test its accuracy. Phantoms were constructed having similar shapes and compression characteristics to breasts of different sizes. These phantoms were compressed at different forces on several types of mammography units and their thickness under compression was measured using optical stereoscopic photogrammetry at many points of contact with the compression plate. A prediction equation was developed that uses the readout of compressed thickness and compression force provided by the mammography system to estimate local breast thickness. Using this approach, systems can be calibrated to an accuracy of better than 5 mm in thickness using a simple test object compared to an error of up to 15 mm associated with using only the thickness readout of the mammography machine. On the systems tested, the estimated value of VBD obtained using this method is significantly reduced from that determined using the constant thickness reported by the mammography machine.


Assuntos
Mama/anatomia & histologia , Mamografia/métodos , Humanos , Modelos Biológicos , Imagens de Fantasmas , Fotogrametria , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Propriedades de Superfície
10.
J Breast Imaging ; 1(3): 161-165, 2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-38424760

RESUMO

Traditionally, the effectiveness of breast cancer screening has been measured in terms of reducing the number of deaths attributable to breast cancer. Other metrics such as the number of life-years or quality-adjusted life-years gained through screening may be more relevant and certainly may better reflect the important burden of the disease on younger women, their families, and society. The effects of earlier detection of breast cancer in reducing morbidities associated with treatment have often also been neglected. In addition, the harms and limitations associated with cancer screening have been poorly quantified and are seldom put into perspective vis-à-vis the benefits. Here, these alternative measures will be discussed and quantified.

11.
Radiology ; 247(1): 38-48, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18372463

RESUMO

PURPOSE: To retrospectively compare the accuracy for cancer diagnosis of digital mammography with soft-copy interpretation with that of screen-film mammography for each digital equipment manufacturer, by using results of biopsy and follow-up as the reference standard. MATERIALS AND METHODS: The primary HIPAA-compliant Digital Mammographic Imaging Screening Trial (DMIST) was approved by the institutional review board of each study site, and informed consent was obtained. The approvals and consent included use of data for future HIPAA-compliant retrospective research. The American College of Radiology Imaging Network DMIST collected screening mammography studies performed by using both digital and screen-film mammography in 49 528 women (mean age, 54.6 years; range, 19-92 years). Digital mammography systems from four manufacturers (Fischer, Fuji, GE, and Hologic) were used. For each digital manufacturer, a cancer-enriched reader set of women screened with both digital and screen-film mammography in DMIST was constructed. Each reader set contained all cancer-containing studies known for each digital manufacturer at the time of reader set selection, together with a subset of negative and benign studies. For each reader set, six or 12 experienced radiologists attended two randomly ordered reading sessions 6 weeks apart. Each radiologist identified suspicious findings and rated suspicion of breast cancer in identified lesions by using a seven-point scale. Results were analyzed according to digital manufacturer by using areas under the receiver operating characteristic curve (AUCs), sensitivity, and specificity for soft-copy digital and screen-film mammography. Results for Hologic digital are not presented owing to the fact that few cancer cases were available. The implemented design provided 80% power to detect average AUC differences of 0.09, 0.08, and 0.06 for Fischer, Fuji, and GE, respectively. RESULTS: No significant difference in AUC, sensitivity, or specificity was found between Fischer, Fuji, and GE soft-copy digital and screen-film mammography. Large reader variations occurred with each modality. CONCLUSION: No statistically significant differences were found between soft-copy digital and screen-film mammography for Fischer, Fuji, and GE digital mammography equipment.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia , Intensificação de Imagem Radiográfica , Ecrans Intensificadores para Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Feminino , Humanos , Mamografia/instrumentação , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/instrumentação , Sensibilidade e Especificidade
12.
Radiology ; 246(2): 376-83, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18227537

RESUMO

PURPOSE: To retrospectively compare the accuracy of digital versus film mammography in population subgroups of the Digital Mammographic Imaging Screening Trial (DMIST) defined by combinations of age, menopausal status, and breast density, by using either biopsy results or follow-up information as the reference standard. MATERIALS AND METHODS: DMIST included women who underwent both digital and film screening mammography. Institutional review board approval at all participating sites and informed consent from all participating women in compliance with HIPAA was obtained for DMIST and this retrospective analysis. Areas under the receiver operating characteristic curve (AUCs) for each modality were compared within each subgroup evaluated (age < 50 vs 50-64 vs >or= 65 years, dense vs nondense breasts at mammography, and pre- or perimenopausal vs postmenopausal status for the two younger age cohorts [10 new subgroups in toto]) while controlling for multiple comparisons (P < .002 indicated a significant difference). All DMIST cancers were evaluated with respect to mammographic detection method (digital vs film vs both vs neither), mammographic lesion type (mass, calcifications, or other), digital machine type, mammographic and pathologic size and diagnosis, existence of prior mammographic study at time of interpretation, months since prior mammographic study, and compressed breast thickness. RESULTS: Thirty-three centers enrolled 49 528 women. Breast cancer status was determined for 42,760 women, the group included in this study. Pre- or perimenopausal women younger than 50 years who had dense breasts at film mammography comprised the only subgroup for which digital mammography was significantly better than film (AUCs, 0.79 vs 0.54; P = .0015). Breast Imaging Reporting and Data System-based sensitivity in this subgroup was 0.59 for digital and 0.27 for film mammography. AUCs were not significantly different in any of the other subgroups. For women aged 65 years or older with fatty breasts, the AUC showed a nonsignificant tendency toward film being better than digital mammography (AUCs, 0.88 vs 0.70; P = .0025). CONCLUSION: Digital mammography performed significantly better than film for pre- and perimenopausal women younger than 50 years with dense breasts, but film tended nonsignificantly to perform better for women aged 65 years or older with fatty breasts.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Mamografia/estatística & dados numéricos , Programas de Rastreamento/estatística & dados numéricos , Intensificação de Imagem Radiográfica , Filme para Raios X/estatística & dados numéricos , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Canadá/epidemiologia , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
13.
AJR Am J Roentgenol ; 191(4): 1203-7, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18806166

RESUMO

OBJECTIVE: Sonographic correlation of breast MRI findings is often challenging. We present a preliminary in vivo feasibility study evaluating the degree of error of a new MRI-sonography coregistration system for showing MRI and sonographically visible breast lesions. CONCLUSION: In 10 patients with 13 lesions, the system was found to be an accurate means for targeting sonography to MRI of the same breast lesions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Biópsia , Meios de Contraste , Desenho de Equipamento , Feminino , Gadolínio DTPA , Humanos , Imageamento por Ressonância Magnética/instrumentação , Pessoa de Meia-Idade , Decúbito Ventral , Estudos Prospectivos , Ultrassonografia Mamária/instrumentação
14.
JAMA ; 299(18): 2151-63, 2008 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-18477782

RESUMO

CONTEXT: Screening ultrasound may depict small, node-negative breast cancers not seen on mammography. OBJECTIVE: To compare the diagnostic yield, defined as the proportion of women with positive screen test results and positive reference standard, and performance of screening with ultrasound plus mammography vs mammography alone in women at elevated risk of breast cancer. DESIGN, SETTING, AND PARTICIPANTS: From April 2004 to February 2006, 2809 women, with at least heterogeneously dense breast tissue in at least 1 quadrant, were recruited from 21 sites to undergo mammographic and physician-performed ultrasonographic examinations in randomized order by a radiologist masked to the other examination results. Reference standard was defined as a combination of pathology and 12-month follow-up and was available for 2637 (96.8%) of the 2725 eligible participants. MAIN OUTCOME MEASURES: Diagnostic yield, sensitivity, specificity, and diagnostic accuracy (assessed by the area under the receiver operating characteristic curve) of combined mammography plus ultrasound vs mammography alone and the positive predictive value of biopsy recommendations for mammography plus ultrasound vs mammography alone. RESULTS: Forty participants (41 breasts) were diagnosed with cancer: 8 suspicious on both ultrasound and mammography, 12 on ultrasound alone, 12 on mammography alone, and 8 participants (9 breasts) on neither. The diagnostic yield for mammography was 7.6 per 1000 women screened (20 of 2637) and increased to 11.8 per 1000 (31 of 2637) for combined mammography plus ultrasound; the supplemental yield was 4.2 per 1000 women screened (95% confidence interval [CI], 1.1-7.2 per 1000; P = .003 that supplemental yield is 0). The diagnostic accuracy for mammography was 0.78 (95% CI, 0.67-0.87) and increased to 0.91 (95% CI, 0.84-0.96) for mammography plus ultrasound (P = .003 that difference is 0). Of 12 supplemental cancers detected by ultrasound alone, 11 (92%) were invasive with a median size of 10 mm (range, 5-40 mm; mean [SE], 12.6 [3.0] mm) and 8 of the 9 lesions (89%) reported had negative nodes. The positive predictive value of biopsy recommendation after full diagnostic workup was 19 of 84 for mammography (22.6%; 95% CI, 14.2%-33%), 21 of 235 for ultrasound (8.9%, 95% CI, 5.6%-13.3%), and 31 of 276 for combined mammography plus ultrasound (11.2%; 95% CI. 7.8%-15.6%). CONCLUSIONS: Adding a single screening ultrasound to mammography will yield an additional 1.1 to 7.2 cancers per 1000 high-risk women, but it will also substantially increase the number of false positives. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00072501.


Assuntos
Neoplasias da Mama/diagnóstico , Mamografia , Ultrassonografia Mamária , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Feminino , Humanos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores de Risco , Sensibilidade e Especificidade
15.
Radiographics ; 27 Suppl 1: S165-82, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18180225

RESUMO

The benefit of screening with breast magnetic resonance (MR) imaging for certain patient populations at high risk for breast cancer, most notably patients with a genetic mutation in the BRCA1 or BRCA2 gene, has been established in numerous studies and is now becoming part of routine clinical practice. Despite the lower sensitivity of mammography compared with that of MR imaging, the former remains the standard of care for screening any patient population. In the BRCA1 and BRCA2 populations, the inferior sensitivity and specificity of ultrasonography (US) limit its role as a screening tool, but US remains a vital diagnostic tool because of its ability to provide guidance for biopsy of many suspicious lesions detected with MR imaging. Important features of a screening program with breast MR imaging include the following: optimization of the MR imaging technique, an awareness of the imaging features of invasive and noninvasive breast cancers detected with MR imaging, an understanding of the limitations of the various imaging modalities in both the initial screening and subsequent diagnostic work-up evaluations, and the requirement for MR imaging-guided biopsy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Genes BRCA1 , Genes BRCA2 , Imageamento por Ressonância Magnética , Neoplasias da Mama/genética , Feminino , Humanos , Radiografia
16.
Med Phys ; 43(3): 1249-58, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26936709

RESUMO

PURPOSE: High mammographic density is known to be associated with decreased sensitivity of mammography. Recent changes in the BI-RADS density assessment address the effect of masking by densities, but the BI-RADS assessment remains qualitative and achieves only moderate agreement between radiologists. An automated, quantitative algorithm that estimates the likelihood of masking of simulated masses in a mammogram by dense tissue has been developed. The algorithm considers both the effects of loss of contrast due to density and the distracting texture or appearance of dense tissue. METHODS: A local detectability (dL) map is created by tessellating the mammograms into overlapping regions of interest (ROIs), for which the detectability by a non-prewhitening observer is computed using local estimates of the noise power spectrum and volumetric breast density (VBD). The dL calculation was validated in a 4-alternative forced-choice observer study on the ROIs of 150 craniocaudal digital mammograms. The dL metric was compared against the inverse threshold contrast, (ΔµT)(-1) from the observer study, the anatomic noise parameter ß, the radiologist's BI-RADS density category, and a validated measure of VBD (Cumulus). RESULTS: The mean dL had a high correlation of r = 0.915 and r = 0.699 with (ΔµT)(-1) in the computerized and human observer study, respectively. In comparison, the local VBD estimate had a low correlation of 0.538 with (ΔµT)(-1). The mean dL had a correlation of 0.663, 0.835, and 0.696 with BI-RADS density, ß, and Cumulus VBD, respectively. CONCLUSIONS: The proposed dL metric may be useful in characterizing the potential for lesion masking by dense tissue. Because it uses information about the anatomic noise or tissue appearance, it is more closely linked to lesion detectability than VBD metrics.


Assuntos
Densidade da Mama , Neoplasias da Mama/diagnóstico por imagem , Mamografia , Artefatos , Neoplasias da Mama/patologia , Humanos , Sensibilidade e Especificidade
17.
J Natl Cancer Inst ; 108(4)2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26712110

RESUMO

BACKGROUND: Mammography is not widely available in all countries, and breast cancer incidence is increasing. We considered performance characteristics using ultrasound (US) instead of mammography to screen for breast cancer. METHODS: Two thousand eight hundred nine participants were enrolled at 20 sites in the United States, Canada, and Argentina in American College of Radiology Imaging 6666. Two thousand six hundred sixty-two participants completed three annual screens (7473 examinations) with US and film-screen (n = 4351) or digital (n = 3122) mammography and had biopsy or 12-month follow-up. Cancer detection, recall, and positive predictive values were determined. All statistical tests were two-sided. RESULTS: One hundred ten women had 111 breast cancer events: 89 (80.2%) invasive cancers, median size 12 mm. The number of US screens to detect one cancer was 129 (95% bootstrap confidence interval [CI] = 110 to 156), and for mammography 127 (95% CI = 109 to 152). Cancer detection was comparable for each of US and mammography at 58 of 111 (52.3%) vs 59 of 111 (53.2%, P = .90), with US-detected cancers more likely invasive (53/58, 91.4%, median size 12 mm, range = 2-40 mm), vs mammography at 41 of 59 (69.5%, median size 13 mm, range = 1-55 mm, P < .001). Invasive cancers detected by US were more frequently node-negative, 34 of 53 (64.2%) vs 18 of 41 (43.9%) by mammography (P = .003). For 4814 incidence screens (years 2 and 3), US had higher recall and biopsy rates and lower PPV of biopsy (PPV3) than mammography: The recall rate was 10.7% (n = 515) vs 9.4% (n = 453, P = .03), the biopsy rate was 5.5% (n = 266) vs 2.0% (n = 97, P < .001), and PPV3 was 11.7% (31/266) vs 38.1% (37/97, P < .001). CONCLUSIONS: Cancer detection rate with US is comparable with mammography, with a greater proportion of invasive and node-negative cancers among US detections. False positives are more common with US screening.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos , Ultrassonografia Mamária , Adulto , Idoso , Idoso de 80 Anos ou mais , Argentina/epidemiologia , Biópsia , Neoplasias da Mama/epidemiologia , Canadá/epidemiologia , Reações Falso-Positivas , Feminino , Humanos , Incidência , Mamografia , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Ultrassonografia Mamária/normas , Ultrassonografia Mamária/estatística & dados numéricos , Ultrassonografia Mamária/tendências , Estados Unidos/epidemiologia
18.
Springerplus ; 4: 631, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26543765

RESUMO

This phase I/II neoadjuvant trial (ClinicalTrials.gov identifier NCT00066443) determined maximally-tolerated doses (MTD), dose-limiting toxicities, response-to-therapy, and explored the role of novel response biomarkers. MA.22 accrued T3N0, any N2 or N3, and T4 breast cancer patients. Treatment was 6 cycles of 3-weekly (Schedule A; N = 47) or 8 cycles of 2-weekly (Schedule B; N = 46) epirubicin/docetaxel chemotherapy in sequential phase I/II studies, with growth factor support. In phase I of each schedule, MTDs were based on DLT. In phase II, clinical responses (CR/PR) and pathologic complete responses (pCR) were assessed. Tumor biopsy cores were obtained pre-, mid-, and post-treatment: 3 for pathologic assessment; 3 for microarray studies. DLT for Schedule A was febrile neutropenia at 105 mg/m(2) epirubicin and 75 mg/m(2) docetaxel; for schedule B, it was fatigue at 75 mg/m(2) for both agents. Phase II doses were 90 mg/m(2) epirubicin/75 mg/m(2) docetaxel for Schedule A and 60 mg/m(2) (both agents) for Schedule B. Schedule A CR/PR and pCR rates were 90 and 10 %, with large reductions in tumor RNA content and integrity following treatment; Schedule B results were 93 and 0 %, with smaller reductions in RNA quality. Pre-treatment expression of several genes was associated with clinical response, including those within a likely amplicon at 17q12 (ERBB2, TCAP, GSDMB, and PNMT). The combination regimens had acceptable toxicity, good clinical response, induction of changes in tumor RNA content and integrity. Pre-treatment expression of particular genes was associated with clinical responses, including several near 17q12, which with ERBB2, may better identify chemoresponsiveness.

19.
JAMA ; 292(11): 1317-25, 2004 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-15367553

RESUMO

CONTEXT: Current recommendations for women who have a BRCA1 or BRCA2 mutation are to undergo breast surveillance from age 25 years onward with mammography annually and clinical breast examination (CBE) every 6 months; however, many tumors are detected at a relatively advanced stage. Magnetic resonance imaging (MRI) and ultrasound may improve the ability to detect breast cancer at an early stage. OBJECTIVE: To compare the sensitivity and specificity of 4 methods of breast cancer surveillance (mammography, ultrasound, MRI, and CBE) in women with hereditary susceptibility to breast cancer due to a BRCA1 or BRCA2 mutation. DESIGN, SETTING, AND PARTICIPANTS: A surveillance study of 236 Canadian women aged 25 to 65 years with BRCA1 or BRCA2 mutations who underwent 1 to 3 annual screening examinations, consisting of MRI, mammography, and ultrasound at a single tertiary care teaching hospital between November 3, 1997, and March 31, 2003. On the day of imaging and at 6-month intervals, CBE was performed. MAIN OUTCOME MEASURES: Sensitivity and specificity of each of the 4 surveillance modalities, and sensitivity of all 4 screening modalities vs mammography and CBE. RESULTS: Each imaging modality was read independently by a radiologist and scored on a 5-point Breast Imaging Reporting and Data System scale. All lesions with a score of 4 or 5 (suspicious or highly suspicious for malignancy) were biopsied. There were 22 cancers detected (16 invasive and 6 ductal carcinoma in situ). Of these, 17 (77%) were detected by MRI vs 8 (36%) by mammography, 7 (33%) by ultrasound, and 2 (9.1%) by CBE. The sensitivity and specificity (based on biopsy rates) were 77% and 95.4% for MRI, 36% and 99.8% for mammography, 33% and 96% for ultrasound, and 9.1% and 99.3% for CBE, respectively. There was 1 interval cancer. All 4 screening modalities combined had a sensitivity of 95% vs 45% for mammography and CBE combined. CONCLUSIONS: In BRCA1 and BRCA2 mutation carriers, MRI is more sensitive for detecting breast cancers than mammography, ultrasound, or CBE alone. Whether surveillance regimens that include MRI will reduce mortality from breast cancer in high-risk women requires further investigation.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/genética , Genes BRCA1 , Genes BRCA2 , Adulto , Biópsia , Reações Falso-Positivas , Feminino , Predisposição Genética para Doença , Humanos , Imageamento por Ressonância Magnética , Mamografia , Pessoa de Meia-Idade , Mutação , Exame Físico , Sensibilidade e Especificidade , Ultrassonografia Mamária
20.
Med Phys ; 40(5): 051910, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23635280

RESUMO

PURPOSE: The use of an intravenously injected iodinated contrast agent could help increase the sensitivity of digital mammography by adding information on tumor angiogenesis. Two approaches have been made for clinical implementation of contrast-enhanced digital mammography (CEDM), namely, single-energy (SE) and dual-energy (DE) imaging. In each technique, pairs of mammograms are acquired, which are then subtracted with the intent to cancel the appearance of healthy breast tissue to permit sensitive detection and specific characterization of lesions. Patterns of contrast agent uptake in the healthy parenchyma, and uncanceled signal from background tissue create a "clutter" that can mask or mimic an enhancing lesion. This type of "anatomical noise" is often the limiting factor in lesion detection tasks, and thus, noise quantification may be useful for cascaded systems analysis of CEDM and for phantom development. In this work, the authors characterize the anatomical noise in CEDM clinical images and the authors evaluate the influence of the x-ray energy used for acquisition, the presence of iodine in the breast, and the timing of imaging postcontrast administration on anatomical noise. The results are presented in a two-part report, with SE CEDM described here, and DE CEDM in Part II. METHODS: A power law is used to model anatomical noise in CEDM images. The exponent, ß, which describes the anatomical structure, and the constant α, which represents the magnitude of the noise, are determined from Wiener spectra (WS) measurements on images. A total of 42 SE CEDM cases from two previous clinical pilot studies are assessed. The parameters α and ß are measured both from unprocessed images and from subtracted images. RESULTS: Consistent results were found between the two SE CEDM pilot studies, where a significant decrease in ß from a value of approximately 3.1 in the unprocessed images to between about 1.1 and 1.8 in the subtracted images was observed. Increasing the x-ray energy from that used in conventional DM to those of typical SE CEDM spectra with mean energies above 33 keV significantly decreased α by about a factor of 19, in agreement with theory. Compared to precontrast images, in the unprocessed postcontrast images at 30 s postinjection, α was larger by about 7.4 × 10(-7) mm(2) and ß was decreased by 0.2. While α did not vary significantly with the time after contrast administration, ß from the unprocessed image WS increased linearly, and ß from subtracted image WS increased with an initial quadratic relationship that plateaued by about 5 min postinjection. CONCLUSIONS: The presence of an iodinated contrast agent in the breast produced small, but significant changes in the power law parameters of unprocessed CEDM images compared to the precontrast images. Image subtraction in SE CEDM significantly reduced anatomical noise compared to conventional DM, with a reduction in both α and ß by about a factor of 2. The data presented here, and in Part II of this work, will be useful for modeling of CEDM backgrounds, for systems characterization and for lesion detectability experiments using models that account for anatomical noise.


Assuntos
Mama/anatomia & histologia , Meios de Contraste , Mamografia/métodos , Intensificação de Imagem Radiográfica/métodos , Adulto , Idoso , Mama/citologia , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA