Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Prosthet Dent ; 132(2): 420.e1-420.e6, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38729791

RESUMO

STATEMENT OF PROBLEM: Minimally invasive treatments have gained popularity in recent years. However, research comparing the fracture resistance of lithium disilicate partial coverage veneer restorations with that of ceramic crowns is lacking. PURPOSE: The purpose of this in vitro study was to evaluate and compare the fracture resistance of lithium disilicate restorations fabricated for preparations of various designs. The designs included veneer preparations with finish lines in the upper, middle, and lower third of the facial surface and ceramic crown preparations with margins in the lower third of the facial surface. All restorations were designed and fabricated using a chairside digital workflow. MATERIAL AND METHODS: Four maxillary right central incisor typodont teeth were prepared for partial coverage veneer preparation with the margin in the upper middle third of the facial surface (PU1/3); partial coverage veneer preparation with margin in lower middle third of the facial surface (PL1/3); complete coverage veneer preparation (CV) with margin in the cervical region; and ceramic crown (CC) preparation. Each preparation was scanned, and 15 casts were 3D printed from each scan. A total of 60 lithium disilicate restorations were fabricated (n=15 per group) using a chairside computer-aided design and computer-aided manufacturing (CAD-CAM) system (Primescan and MCXL). The different restorations were cemented to the 3D printed testing dies with a photopolymerizable resin cement. The specimens were artificially aged with 10 000 thermal cycles between 5 and 55 °C with a dwell time of 30 seconds and were loaded to failure using a universal testing machine. The maximum load to fracture was analyzed using a 1-way ANOVA and post hoc Tukey honestly significant difference (HSD) test (α=.05). Additionally, the fracture patterns of the specimens were evaluated with a stereomicroscope for descriptive purposes. RESULTS: The mean fracture resistance of the chairside CAD-CAM lithium disilicate veneers and ceramic crowns was statistically different depending on the design of the restoration (P<.05). Group CC demonstrated the highest fracture resistance values (1440.66 N), followed by CV (929.8 N) and PU1/3 (756.13 N). The lowest value was for PL1/3 (532.4 N). CONCLUSIONS: The fracture resistance measured for the maxillary central incisor partial coverage veneers with margins in the middle third of the facial surface appear capable of resisting average occlusal forces. However, these veneers demonstrated lower fracture resistance values when compared with complete coverage veneers. Further, lithium disilicate crowns demonstrated higher fracture resistance than veneers, irrespective of their design.


Assuntos
Cerâmica , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Facetas Dentárias , Incisivo , Humanos , Análise do Estresse Dentário , Falha de Restauração Dentária , Maxila , Desenho Assistido por Computador , Técnicas In Vitro
2.
J Prosthodont ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38706398

RESUMO

PURPOSE: This study evaluated the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate crown, onlay, and non-anatomical occlusal veneer (A-OV) with and without margin fabricated. MATERIALS AND METHODS: Sixty-four CAD-CAM lithium disilicate restorations were designed as (1) complete coverage crown (CCC); (2) A-OV with margin; (3) non-A-OV with margin (NA-OV-M); and (4) non-A-OV without margin (NA-OV-NM), 16 of each. Restorations were crystallized and adhesively luted to resin dies using resin cement. Specimens were then subjected to 400,000 cycles of chewing in a mastication simulator. A universal testing machine was used to apply a compressive load at a crosshead speed of 1 mm/min to the long axis of the tooth with a stainless-steel sphere until fracture occurred. One-way ANOVA followed by post hoc tests were used to assess the impact of preparation design on the fracture load of CAD-CAM lithium disilicate restorations. RESULTS: The highest fracture load was recorded for CAD-CAM lithium disilicate indirect restorations for non-A-OVs preparation with margin (2549 ± 428 N) and onlay (2549 ± 293 N) and the lowest fracture load was recorded for CCCs (2389 ± 428 N); however, there was no significant (p = 0.640) between groups. CONCLUSIONS: CAD-CAM lithium disilicate restorations fabricated for anatomical and non-A-OV preparation display a fracture resistance similar to CCCs. Conservative partial coverage restorations may be considered an acceptable approach for posterior teeth.

3.
J Prosthodont ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38715352

RESUMO

PURPOSE: To evaluate the fracture load of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) veneers fabricated with two conventional pre-crystallized and two fully crystallized lithium disilicate ceramic materials. MATERIALS AND METHODS: Seventy-five chairside CAD-CAM veneers (15 specimens/group) for maxillary right central incisors were fabricated with different lithium disilicate brands: (1) IPS e.max CAD; (2) Amber Mill; (3) Cerec Tessera; (4) n!ce Straumann; and (5) GC Initial LiSi Block. Restorations were cemented with resin luting cement (Variolink Esthetic, Ivoclar) to 3D-printed resin dies. Bonded restorations received 5000 thermal cycles and then were loaded until fracture. Statistical analysis included One-Way ANOVA. RESULTS: Conventional pre-crystallized e.max CAD displayed the highest fracture load value (640 N), followed by fully-crystallized n!ce Straumann (547 N), pre-crystallized Cerec Tessera (503 N), pre-crystallized Amber Mill (476 N), respectively; fully-crystallized GC Initial LiSi Block (431 N) displayed the lowest values. When comparing the fracture load of recent lithium disilicate ceramic material to the e.max group, which acted as the control, significant differences were noted. The LiSi Block GC group, in particular, had considerably higher mean difference values (208.867, p < 0.001, 95% CI [89.63, 328.10]), as did the Amber Mill group (164.200, p = 0.002, 95% CI [44.96, 283.44]) and CEREC Tessera group (137.533, p = 0.016, 95% CI [18.30, 256.77]). The e.max and n!ce Straumann groups had no statistically significant differences in mean scores (92.933, p = 0.198, 95% CI [-26.30, 212.17]). These findings imply that the clinical performance of recent lithium disilicate veneers varies when compared to the e.max CAD group. CONCLUSIONS: The fracture load of chairside CAD-CAM lithium disilicate veneers for maxillary central incisors varies according to the type of ceramic brands. Conventional pre-crystallized e.max CAD displayed higher fracture load than the recent pre- and fully-crystallized lithium disilicate materials, emphasizing the significance of choosing the right product based on the desired clinical outcome.

4.
J Prosthodont ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38790151

RESUMO

PURPOSE: To evaluate the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate mandibular posterior crowns with virgilite of different occlusal thicknesses and compare them to traditional lithium disilicate crowns. MATERIALS AND METHODS: Seventy-five chairside CAD-CAM crowns were fabricated for mandibular right first molars, 60 from novel lithium disilicate with virgilite (CEREC Tessera, Dentsply Sirona), and 15 from traditional lithium disilicate (e.max CAD, Ivoclar Vivadent). These crowns were distributed across five groups based on occlusal thickness and material: Group 1 featured CEREC Tessera crowns with 0.8 mm thickness, Group 2 had 1.0 mm thickness, Group 3 had 1.2 mm thickness, Group 4 with 1.5 mm thickness, and Group 5 included e.max CAD crowns with 1.0 mm thickness. These crowns were luted onto 3D-printed resin dies using Multilink Automix resin cement (Ivoclar Vivadent). Subsequently, they underwent cyclic loading (2,000,000 cycles at 1 Hz with a 275 N force) and loading until fracture. Scanning electron microscopy (SEM) assessed the fractured specimens. Statistical analysis involved one-way ANOVA and the Kruskal-Wallis Test (α = 0.05). RESULTS: Fracture resistance varied significantly (<0.001) across mandibular molar crowns fabricated from chairside CAD-CAM lithium disilicate containing virgilite, particularly between crowns with 0.8 mm and those with 1.2 and 1.5 mm occlusal thickness. However, no significant differences were found when comparing crowns with 1, 1.2, and 1.5 mm thicknesses. CEREC Tessera crowns with 1.5 mm thickness exhibited the highest resistance (2119 N/mm2), followed by those with 1.2 mm (1982 N/mm2), 1.0 mm (1763 N/mm2), and 0.8 mm (1144 N/mm2) thickness, whereas e.max CAD crowns with 1.0 mm occlusal thickness displayed the lowest resistance (814 N/mm2). CONCLUSIONS: The relationship between thickness and fracture resistance in the virgilite lithium disilicate full-coverage crowns was directly proportional, indicating that increased thickness corresponded to higher fracture resistance. No significant differences were noted among crowns with thicknesses ranging from 1 to 1.5 mm. This novel ceramic exhibited superior fracture resistance compared to traditional lithium disilicate.

5.
J Prosthodont ; 33(S1): 10-24, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38992883

RESUMO

PURPOSE: This systematic review and meta-analysis aimed to evaluate the depth distortion and angular deviation of fully-guided tooth-supported static surgical guides (FTSG) in partially edentulous arches compared to partially guided surgical guides or freehand. MATERIAL AND METHODS: This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and was registered in the Open Science Framework (OSF). The formulated population, intervention, comparison, and outcome (PICO) question was: "In partially edentulous arches, what are the depth distortion and angular deviation of FTSG compared to partially guided surgical guides or freehand?" The search strategy involved four main electronic databases, and an additional manual search was completed in November 2023 by following an established search strategy. Initial inclusion was based on titles and abstracts, followed by a detailed review of selected studies, and clinical studies that evaluated the angular deviations or depth distortion in FTSG in partial arches, compared to partially guided surgical guides or freehand, were included. In FTSG, two surgical approaches were compared: open flap and flapless techniques, and two digital methods were assessed for surgical guide design with fiducial markers or dental surfaces. A qualitative analysis for clinical studies was used to assess the risk of bias. The certainty of the evidence was assessed according to the grading of recommendations, assessment, development, and evaluations (GRADE) system. In addition, a single-arm meta-analysis of proportion was performed to evaluate the angular deviation of freehand and FTSG. RESULTS: Ten studies, published between 2018 and 2023, met the eligibility criteria. Among them, 10 studies reported angular deviations ranging from -0.32° to 4.96° for FTSG. Regarding FTSG surgical approaches, seven studies examined the open flap technique for FTSG, reporting mean angular deviations ranging from 2.03° to 4.23°, and four studies evaluated flapless FTSG, reporting angular deviations ranging from -0.32° to 3.38°. Six studies assessed the freehand surgical approach, reporting angular deviations ranging from 1.40° to 7.36°. The mean depth distortion ranged between 0.19 mm to 2.05 mm for open flap FTSG, and between 0.15 mm to 0.45 mm for flapless FTSG. For partially guided surgical guides, two studies reported angular deviations ranging from 0.59° to 3.44°. Seven studies were eligible for meta-analysis, focusing on the FTSG in open flap technique, with high heterogeneity (I2 (95%CI) = 92.3% (88.7%-96.4%)). In contrast, heterogeneity was low in studies comparing freehand versus FTSG in open flap techniques (I2 (95%CI) = 21.3% (0.0%-67.8%)), favoring the FTSG surgical approach. CONCLUSION: In partially edentulous arches, FTSG systems exhibited less angular deviation than freehand and partially guided surgical guides. Flapless surgical approaches were associated with reduced angular deviation and depth distortion, suggesting a potential preference for the FTSG method in these procedures.


Assuntos
Arcada Parcialmente Edêntula , Cirurgia Assistida por Computador , Humanos , Cirurgia Assistida por Computador/métodos , Arcada Parcialmente Edêntula/cirurgia , Implantação Dentária Endóssea/métodos
6.
J Prosthodont ; 33(3): 281-287, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37014263

RESUMO

PURPOSE: This study aimed to assess the fracture resistance of monolithic zirconia-reinforced lithium silicate laminate veneers (LVs) fabricated on various incisal preparation designs. MATERIALS AND METHODS: Sixty maxillary central incisors with various preparation designs were 3D-printed, 15 each, including preparation for: (1) LV with feathered-edge design; (2) LV with butt-joint design; (3) LV with palatal chamfer; and (4) full-coverage crown. Restorations were then designed and manufactured from zirconia-reinforced lithium silicate (ZLS) following the contour of a pre-operation scan. Restorations were bonded to the assigned preparation using resin cement and following the manufacturer's instructions. Specimens were then subjected to 10,000 thermocycles at 5 to 55°C with a dwell time of 30 s. The fracture strength of specimens was then assessed using a universal testing machine at a crosshead speed of 1.0 mm/min. One-way ANOVA and Bonferroni correction multiple comparisons were used to assess the fracture strength differences between the test groups (α = 0.001). Descriptive fractographic analysis of specimens was carried out with scanning electron microscopy images. RESULTS: Complete coverage crown and LV with palatal chamfer design had the highest fracture resistance values (781.4 ± 151.4 and 618.2 ± 112.6 N, respectively). Single crown and LV with palatal chamfer had no significant difference in fracture strength (p > 05). LV with feathered-edge and butt-joint designs provided significantly (p < 05) lower fracture resistance than complete coverage crown and LV with palatal chamfer design. CONCLUSION: The fracture resistance of chairside milled ZLS veneers was significantly influenced by the incisal preparation designs tested. Within the limitation of this study, when excessive occlusal forces are expected, LV with palatal chamfer display is the most conservative method of fabricating an indirect restoration.


Assuntos
Cerâmica , Porcelana Dentária , Porcelana Dentária/uso terapêutico , Resistência à Flexão , Lítio , Teste de Materiais , Análise do Estresse Dentário , Coroas , Zircônio/uso terapêutico , Silicatos , Desenho Assistido por Computador , Planejamento de Prótese Dentária
7.
J Prosthodont ; 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38734932

RESUMO

PURPOSE: To evaluate the fracture resistance of zirconia overlays, considering various preparation designs and the presence of endodontic access. MATERIALS AND METHODS: Ninety translucent zirconia (5Y-PSZ) overlay restorations were divided into six groups (n = 15/group) based on different preparation designs, with and without endodontic access: chamfer margin 4 mm above the gingival level without (group 1) and with endodontic access (group 2); margin 2 mm above the gingival level without (group 3) and with endodontic access (group 4); overlay with no chamfer margin without (group 5) and with endodontic access (group 6). Restorations were bonded to mandibular first molar resin dies, and the groups with endodontic access were sealed with flowable resin composite. All restorations underwent 100,000 cycles of thermal cycling between 5°C and 55°C, followed by loading until fracture. Maximum load and fracture resistance were recorded. ANOVA with Tukey post-hoc tests were used for statistical comparison (α < 0.05). RESULTS: Fracture resistance significantly varied among overlay designs with and without endodontic access (p < 0.001), except for the no-margin overlays (groups 5 and 6). Overlays with a 2 mm margin above the gingival margin with endodontic access (group 4) exhibited significantly higher fracture resistance compared to both the 4-mm supragingival (group 2) and no-margin (group 6) designs, even when compared to their respective intact groups (groups 1 and 5). There were no significant differences between the no-margin and 4-mm supragingival overlays. CONCLUSION: The more extensive zirconia overlay for mandibular molars is the first choice since the 2 mm margin above the gingival level design withstood considerable loads even after undergoing endodontic access. A no-margin overlay is preferred over the 4-mm supragingival design as it preserves more tooth structure and there was no outcome difference, irrespective of endodontic access. Caution is warranted in interpreting these findings due to the in vitro nature of the study.

8.
Medicina (Kaunas) ; 60(2)2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38399547

RESUMO

With the life expectancy increasing, there is a growing need for prosthetic dental treatments to restore the oral health, function, and quality of life of edentulous patients. Presently, only a few articles are available describing the oral rehabilitation of patients with severely resorbed ridges with milled complete dentures. This clinical case report provides a straightforward protocol consisting of a combination of analog and digital techniques for the rehabilitation of edentulous patients with severely resorbed ridges with milled fixed and removable complete dentures. This technique permits the minimization of the number of appointments, improves patient comfort, allows for the digital archiving of important clinical data, and permits the manufacture of prostheses with improved mechanical properties. These favorable outcomes were achieved by using the patient's existing PMMA complete denture as a custom tray for a final impression with light-bodied Polyvinylsiloxane. Subsequently, the resulting models were digitized, and a digital complete denture was designed and manufactured in an expedited manner using CAD-CAM techniques. Therefore, this case report highlights the potential of CAD/CAM technology to predictably restabilize oral functions and improve patients' quality of life.


Assuntos
Boca Edêntula , Qualidade de Vida , Humanos , Prótese Total , Boca Edêntula/reabilitação , Desenho Assistido por Computador
9.
Evid Based Dent ; 25(2): 71-72, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38570647

RESUMO

DESIGN: This study was an extension of a randomized crossover clinical trial approved by the institutional ethics committee (approval number: D2014-148) and adhered to the CONSORT guidelines. The original study juxtaposed patient contentment with single-implant overdentures (1-IODs) against conventional complete dentures (CCDs), with patient satisfaction being the primary focus. In this follow-up study, the cognitive function of edentulous patients receiving 1-IODs was assessed, specifically monitoring for the emergence of mild cognitive impairment (MCI) throughout a three-year period. Patient outcomes were systematically recorded at predetermined intervals: initially, two months post-1-IOD placement, after one year (with groups alternated between denture types at eight-month marks), then after two and three years. A prosthodontist with a decade of expertise performed all denture-related procedures. This follow-up emphasized the cognitive outcomes using the Montreal Cognitive Assessment (MoCA-J), considering it alongside previously documented results on masticatory function, bone resorption, survival rates, and patient-reported outcomes. CASE SELECTION: Between 2015 and 2016, a follow-up study enrolled edentulous patients over 50 years of age who were proficient in Japanese, had sufficient mandibular bone for implants, and were free of systemic health issues and habits that could impact oral health. The participants were randomly divided into two groups after receiving a central mandibular implant. Group 1 initially used 1-IODs, and Group 2 used unloaded CCDs. After two months and subsequent periods, they swapped denture types. Eventually, all patients chose 1-IODs for continued use. Implant success was monitored over three years. The design featured block randomization and accounted for a sample size of 22, determined to be sufficient for evaluating the primary outcome of patient satisfaction. All patients underwent careful allocation and received customized dental interventions, with detailed radiographic planning and surgical precision guiding the implantation process. DATA ANALYSIS: Multivariable linear mixed models were used to assess within-group changes in both overall and specific cognitive function scores across five timepoints. Age, assessment interval, and upper jaw denture status were incorporated as consistent variables, while individual participants were considered variable elements in the analysis. SPSS software version 22.0 was utilized to conduct the statistical tests, and a p value threshold of 0.05 was predetermined to establish statistical significance. RESULTS: Twenty-two patients with edentulous mandibles received 1-IODs. Memory and executive functions saw significant score increases at multiple timepoints over the three-year period, with statistical significance. Though one participant dropped out and another passed away, and two did not complete the 3-year follow-up, the remaining 18 participants provided comprehensive data. Age and type of maxillary denture were significant factors, influencing MoCA-J scores with older participants and those with fixed dentures showing lower scores in certain domains. Overall, the findings illustrated the positive correlation between 1-IODs and cognitive function in older adults. CONCLUSIONS: Older adults with no natural teeth left in their mandible showed improved cognitive function after one and three years of using 1-IODs, as reflected by their total and specific cognitive domain scores. The study suggests that such implant therapy may offer protective benefits against cognitive decline, demonstrating clinical relevance for patient care, regardless of the maxillary arch (antagonist) condition.


Assuntos
Cognição , Revestimento de Dentadura , Humanos , Idoso , Feminino , Masculino , Prótese Dentária Fixada por Implante/métodos , Estudos Cross-Over , Disfunção Cognitiva , Idoso de 80 Anos ou mais , Satisfação do Paciente , Pessoa de Meia-Idade , Seguimentos , Boca Edêntula
10.
Evid Based Dent ; 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39289553

RESUMO

DESIGN: A single-center (university-setting), prospective, longitudinal, split-mouth, single-blind, randomized controlled clinical trial investigated peri-implant parameters of bone-level implants restored with either screw-retained prostheses connected directly to the implants or with intermediate abutments over a 3-year period. The study adhered to the ethical principles of the Helsinki Declaration and the CONSORT guidelines. Ethical approval was granted, and the trial was registered at Clinicaltrials.gov . CASE SELECTION: Participants included were over 18 years of age, had a plaque index below 25%, and were missing at least two adjacent teeth, allowing for rehabilitation with screw-retained fixed partial prostheses over two implants and 2-4 prosthetic units. Exclusion criteria included long-term use of medications affecting bone metabolism, smoking more than 10 cigarettes per day, history of local radiotherapy, untreated periodontitis, and the need for rehabilitation in the anterior sextant of the maxilla. The primary clinical outcome was marginal bone loss (MBL), while secondary outcomes included probing pocket depth (PPD), plaque index (PI), bleeding on probing (BOP), and patient-reported outcomes (PROs). STUDY TIMELINE: The study schedule included a screening (visit 1), implant surgery (visit 2), stage-two 8 weeks post-surgery (visit 3), impressions taken 4 weeks post stage-two (visit 4), baseline standardized radiograph (visit 5), followed by 6-month (visit 6), 12-month (visit 7), and 36-month (visit 8) follow-up visits. DATA ANALYSIS: Descriptive statistics and quantitative measures included means, standard deviations (SDs), minimum and maximum values, and 95% confidence intervals (CIs). Clinical parameters (six sites per implant) measured were MBL, PPD, PI, and BOP. Paired t tests were utilized for intragroup comparisons across different time points and intergroup comparisons at each time point. PROs at 36 months were compared using Student's t test. The alpha significance level was set at 0.05. RESULTS: The study included 36 patients (72 implants), with two not completing the follow-up due to death and relocation. No implants showed signs of inflammation or mobility. Mean interproximal bone level (IBL) at baseline was 0.13 mm ± 0.15 mm for the control group and 0.10 ± 0.13 mm for the test group. At the 36-month follow-up, mean IBL was 0.13 ± 0.18 mm for the control group and 0.20 ± 0.24 mm for the test group, with no significant differences (F(1, 32) = 1.06; p > 0.05). Clinical parameters (PPD, BOP, PI) at 36 months showed no significant differences between groups. Minor complications occurred in 6.7% of the control group and 5.3% of the test group. PROs indicated no significant differences in general satisfaction, esthetics, comfort, phonetics, and masticatory function between the groups. CONCLUSIONS: After a 36-month follow-up, bone-level implants restored with CAD/CAM prostheses directly connected to the implants displayed similar clinical outcomes, PROs, and marginal bone level changes as those restored with intermediate standardized abutments.

11.
J Acoust Soc Am ; 154(1): 50-53, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37403990

RESUMO

Even barely detectable levels of infrasound are often reported to cause annoyance and complaints. We carefully measured the individual sensation threshold of a pure tone and recorded immediately after the brain's frequency-following response (FFR) at this intensity using the same stimulator. In contrast to 87-Hz tones, 8-Hz tones elicit an FFR already at sensation threshold. Control stimuli with trains of 1-kHz tone pips having the repetition rate of the infrasound tone frequency and sensation threshold intensities evoked no significant FFR. Thus, slow periodicity, causing synchronous activation of auditory nuclei, is not explaining the FFR to low-level infrasound alone.


Assuntos
Periodicidade , Sensação , Estimulação Acústica , Limiar Auditivo/fisiologia , Potenciais Evocados Auditivos
12.
Enferm Infecc Microbiol Clin ; 41(3): 149-154, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34456409

RESUMO

Background: The COVID-19 pandemic has affected the care of patients with other diseases. Difficulty in access to healthcare during these months has been especially relevant for persons with HIV infection (PWH). This study therefore sought to ascertain the clinical outcomes and effectiveness of the measures implemented among PWH in a region with one of the highest incidence rates in Europe. Methods: Retrospective, observational, pre-post intervention study to compare the outcomes of PWH attended at a high-complexity healthcare hospital from March to October 2020 and during the same months across the period 2016-2019. The intervention consisted of home drug deliveries and preferential use of non face-to-face consultations. The effectiveness of the measures implemented was determined by reference to the number of emergency visits, hospitalisations, mortality rate, and percentage of PWH with viral load >50 copies, before and after the two pandemic waves. Results: A total of 2760 PWH were attended from January 2016 to October 2020. During the pandemic, there was a monthly mean of 106.87 telephone consultations and 2075 home deliveries of medical drugs dispensed to ambulatory patients. No statistically significant differences were found between the rate of admission of patients with COVID-HIV co-infection and that of the remaining patients (1172.76 admissions/100,000 population vs. 1424.29, p = 0.401) or in mortality (11.54% vs. 12.96%, p = 0.939). The percentage of PWH with viral load >50 copies was similar before and after the pandemic (1.20% pre-pandemic vs. 0.51% in 2020, p = 0.078). Conclusion: Our results show that the strategies implemented during the first 8 months of the pandemic prevented any deterioration in the control and follow-up parameters routinely used on PWH. Furthermore, they contribute to the debate about how telemedicine and telepharmacy can fit into future healthcare models.


Introducción: La pandemia causada por el SARS-CoV-2 ha afectado a la atención de pacientes con otras enfermedades. La dificultad en el acceso a la asistencia sanitaria durante estos meses es especialmente relevante en las personas con infección por VIH (PCV). El objetivo del estudio fue conocer los resultados clínicos y la efectividad de las medidas implementadas en PCV en una de las regiones con mayor incidencia de Europa. Métodos: Estudio observacional retrospectivo, pre-postintervención, comparando los resultados de PCV atendidos en un hospital de alta complejidad entre marzo-octubre de 2020 y el mismo periodo de 2016 a 2019. La intervención consistió en el envío a domicilio de medicamentos y la realización preferente de consultas no presenciales. La efectividad de las medidas implementadas se determinó por el número de visitas a urgencias, hospitalizaciones, mortalidad y porcentaje de PCV con carga viral > 50 copias antes y después de 2 olas pandémicas. Resultados: Se atendieron 2.760 PCV entre enero de 2016 y octubre de 2020. Durante la pandemia se realizaron una media mensual de 106,87 consultas telefónicas y 2.075 envíos a domicilio de medicamentos de dispensación ambulatoria. No se encontraron diferencias estadísticamente significativas en la frecuentación de pacientes con coinfección COVID-VIH respecto al resto (1.172,76 ingresos/100.000 habitantes vs. 1.424,29, p = 0,401), ni en su mortalidad (11,54 vs. 12,96%, p = 0,939). El porcentaje de PCV con carga viral > 50 copias fue similar antes y después de la pandemia (1,20% prepandemia vs. 0,51% en 2020, p = 0,078). Conclusión: Nuestros resultados revelan que las estrategias implementadas durante los 8 primeros meses de pandemia han evitado el deterioro en parámetros de control y seguimiento empleados habitualmente en PCV. Además, contribuyen a la reflexión sobre el encaje de la telemedicina y telefarmacia en modelos asistenciales futuros.

13.
J Prosthet Dent ; 2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37741726

RESUMO

Removable partial dentures have been used to rehabilitate partially edentulous patients for decades. A challenging but commonly encountered procedure is retrofitting a crown to an existing removable partial denture. Several techniques have been proposed for fabricating these complex prostheses, some involving the intraoral application of polymers to the abutment tooth or making impressions of the preparation with the removable prosthesis seated. The present technique presents an approach that simplifies the design and fabrication of retrofitted crowns for fractured abutment teeth needing foundation restorations. This approach involves the implementation of computer-aided design and computer-aided manufacturing technology to record and utilize the contours of the foundation restoration established intraorally as a blueprint for the retrofitted crown.

14.
J Prosthet Dent ; 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37739880

RESUMO

STATEMENT OF PROBLEM: Studies on the fracture performance of a recently introduced computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate ceramic containing virgilite with different cements are lacking. PURPOSE: The purpose of this in vitro study was to evaluate the fracture resistance of crowns made of a recently introduced chairside CAD-CAM lithium disilicate containing virgilite cemented with different types of adhesive luting cement. MATERIAL AND METHODS: Sixty complete coverage crowns for a maxillary right central incisor were milled out of a lithium disilicate with virgilite (CEREC Tessera) (n=48) and a traditional lithium disilicate (e.max CAD) (n=12) using a chairside CAD-CAM system (Primescan). The central incisor tooth preparation included a 1.5-mm incisal reduction, a 1.0-mm axial reduction, and a 1.0-mm chamfer finish line. The restorations were bonded with different types of resin cement to 3D printed dies of the tooth preparation and were divided into 5 groups (n=12 per group): e.max CAD with Multilink Automix (E.Mu); Tessera with Multilink Automix (T.Mu); Tessera with Calibra (T.Ca); Tessera with Unicem (T.Un); and Tessera with Speedcem (T.Sp). The cemented restorations were stored in water for 30 days and then loaded until they were fractured in compression. The load at fracture was analyzed with a 1-way analysis of variance (ANOVA) and the honestly significant difference (HSD) Tukey test (α=.05). RESULTS: The mean fracture resistance of traditional lithium disilicate and virgilite lithium disilicate anterior crowns significantly differed depending on the type of resin cement used (P<.05). Group E.Mu displayed the highest values (946.35 ±155 N), followed by group T.Un (819.59 ±232 N), group T.Sp (675.52 ±153 N), and group T.Mu (656.95 ±193 N). The lowest values were displayed by group T.Ca (567.94 ±184 N). CONCLUSIONS: The fracture resistance of lithium disilicate containing virgilite and traditional lithium disilicate crowns cemented with the same cement displayed statistically similar values. However, significant differences were observed when the virgilite lithium disilicate crowns were cemented with different types of adhesive luting cement. The crowns in the T.Ca group displayed the lowest fracture resistance.

15.
J Prosthodont ; 32(9): 861-866, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36609993

RESUMO

PURPOSE: The available independent data on the translucency of novel pre and fully sintered chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate are limited. This comparative in vitro study evaluated the translucency degree of pre and fully sintered chairside CAD-CAM lithium disilicate crowns after optional, required, and additional firing processes. MATERIALS AND METHODS: One hundred and five maxillary left central incisor crowns manufactured by three different CAD-CAM lithium disilicate brands shade A1 were assigned into seven groups as follows (n = 15): (1) Straumann n!ce without sintering; (2) Straumann n!ce with one additional sintering process; (3) Straumann n!ce with two additional sintering processes; (4) Amber Mill with one sintering process; (5) Amber Mill with two sintering processes; (6) IPS e.max CAD with one sintering process; and (7) IPS e.max CAD with two sintering processes. The translucency of all crowns was evaluated with a color imaging spectrophotometer. All statistical analyses were performed using statistical software. A standard level of significance was set at α < 0.05. RESULTS: All the milled crowns presented different degrees of translucency, and additional sintering processes altered it. IPS e.max CAD with two (4.33 ± 0.26) and one (4.01 ± 0.15) sintering processes displayed the highest translucency, whereas Straumann n!ce with no sintering process provided the lowest value (2.82 ± 0.16). CONCLUSIONS: The translucency of chairside lithium disilicate single-unit full-coverage restorations manufactured with subtractive technology was significantly influenced by the brand and the number of sintering processes. The traditional presintered IPS e.max CAD and the fully crystallized glass-ceramic Straumann n!ce considerably increased the translucency after one additional firing process, whereas Amber Mill decreased its translucency.


Assuntos
Âmbar , Porcelana Dentária , Cerâmica , Coroas , Desenho Assistido por Computador , Teste de Materiais
16.
J Prosthodont ; 2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37471621

RESUMO

PURPOSE: To determine the fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) zirconia surveyed crowns for a mandibular first molar without occlusal rest and with four different rest seat designs. MATERIALS AND METHODS: Seventy CAD-CAM zirconia 4Y-PSZ (IPS e.max ZirCAD MT for CEREC A1, C15, Ivoclar Vivadent) crowns (14 specimens/group) were designed and fabricated with a dental chairside CAD-CAM system (CEREC PrimeScan, and CEREC MCXL Dentsply Sirona). The restorations were divided into groups according to the following rest seat designs: (1) Surveyed crown without rest seat, (2) surveyed crowns with disto-occlusal rest seat, (3) surveyed crowns with disto-occlusal extended rest seat, (4) surveyed crowns with interproximal rest seat, and (5) continuous rest seat. Crowns were treated with a primer system (Monobond Plus, Ivoclar Vivadent) and cemented using resin luting cement (Multilink Automix, Ivoclar Vivadent) to resin-printed dies (Grey Resin V4, FormLabs). Subsequently, the crowns were subjected to 200,000 load cycles at 1 Hz with 20 N force and then loaded with a steel indenter until fracture. The test results were analyzed with one-way Analysis of Variance (ANOVA) and HSD Tukey post-Hoc test. RESULTS: The mean fracture resistance of surveyed crowns without and with different rest seats was significantly different from each other. Surveyed crowns with no rest seat displayed the highest resistance (4238 N) followed by crowns with continuous rest seat (3601 N), crowns with disto-occlusal extended rest seat (3283 N), and crowns with disto-occlusal rest seat (3257 N). Crowns with interproximal rest seat displayed the lowest fracture resistance (2723 N). CONCLUSIONS: Surveyed crowns without rest seats had a higher fracture resistance than crowns with rest seats Surveyed crowns with interproximal rest seats presented the lowest fracture resistance among all rest seat designs. Crowns with disto-occlusal rest seats, disto-occlusal extended rest seats, and continuous rest seats displayed similar fracture resistance.

17.
J Prosthodont ; 32(8): 728-734, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36471494

RESUMO

PURPOSE: To evaluate the effect of traditional and conservative endodontic access hole preparation on fracture resistance of chairside computer-aided design and computer-aided manufacturing (CAD-CAM) lithium disilicate maxillary right central incisor crowns. MATERIALS AND METHODS: Fifty-seven milled lithium disilicate maxillary right central incisor crowns were designed and fabricated with a chairside CAD-CAM system (Planmeca Romexis, Planmeca). The abutment preparation had a 1.0 mm incisal reduction and 1.0 mm chamfer finish. The restorations were bonded with resin cement to printed resin dies (n = 19 per group) and were treated and divided into three groups, (1) no endodontic access, (2) traditional triangular endodontic access, and (3) conservative ovoidal endodontic access. The endodontic access of the crowns was sealed with flowable resin composite. Restorations were subjected to 10,000 cycles of thermal cycling between 5° and 55°C. Then, restorations were loaded and exposed to compressive loading force, and the crack initiation (CI) and complete fracture (CF) were recorded. SEM micrographs of broken specimens on the printed dies were captured. ANOVA test and Bonferroni's correction were used for statistical comparison. RESULTS: The fracture resistance among the three groups varied. Crowns with no endodontic access displayed significantly (p < 0.001) higher resistance [CI: 1025 (121) N; CF 1134 (127) N], followed by crowns with conservative ovoidal endodontic access [CI: 924 (60) N; CF: 1000 (72) N. Crowns with traditional triangular endodontic access showed the significantly (p < 0.001) lowest fracture resistance [CI: 635 (82) N; CF: 709 (75) N]. CONCLUSION: The fracture resistance of chairside CAD-CAM lithium disilicate maxillary anterior crowns is influenced by the type of endodontic access provided. Conservative ovoidal endodontic access provides crowns with higher fracture resistance than traditional triangular endodontic access. Crowns with no endodontic access provided the highest resistance than other types of endodontic access.


Assuntos
Cerâmica , Falha de Restauração Dentária , Teste de Materiais , Análise do Estresse Dentário , Porcelana Dentária , Coroas , Desenho Assistido por Computador , Planejamento de Prótese Dentária
18.
Medicina (Kaunas) ; 59(3)2023 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-36984604

RESUMO

Minimally invasive dentistry is a considered process that requires the clinician to be prepared with the ideal sequence and the tools needed. This report describes a well-planned ultraconservative approach using only two ceramic laminate veneers for the maxillary central incisors to significantly improve the patient's overall smile. A 30-year-old female presented with the chief complaints of having diastemas between the central and lateral incisors as well as incisal wear. Diagnostic wax-up and mock-up were performed, and the patient approved the minimally invasive treatment with veneers only for central incisors. A reduction guide aided the conservative tooth preparations, and hand-crafted feldspathic veneers were bonded under total isolation with a rubber dam. The two final conservative veneers significantly improved the smile and fulfilled the patient's expectations. Following proper planning and sequencing, predictable outcomes were obtained and fulfilled the patient's esthetic demands. Minimally invasive restorative dentistry with only two single veneers can impact the entire smile frame. Overtreatment in the esthetic zone is unnecessary to meet a patient's esthetic expectations.


Assuntos
Bullying , Incisivo , Feminino , Humanos , Adulto , Cerâmica
19.
Medicina (Kaunas) ; 59(6)2023 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-37374252

RESUMO

Background and Objective: This study aimed to compare the surface finish of milled leucite-reinforced ceramics polished with ceramic and composite polishing systems based on the manufacturers' recommendations. Materials and Methods: Sixty subtractive computer-aided manufactured (s-CAM) leucite-reinforced glass-ceramic specimens (IPS-Empress-CAD) were assigned into six groups: no polishing, a ceramic polishing kit, and four composite kit groups. The roughness average (Ra) was evaluated in microns using a profilometer, and scanning electron micrographs were obtained for qualitative analysis. A Tukey HSD posthoc test (α = 0.05) was used to determine significant intergroup differences. Results: After surface evaluation of the ceramics, the Ra values of the polishing systems ranked OptraFine (0.41 ± 0.26) < Enhance (1.60 ± 0.54) < Shofu (2.14 ± 0.44) < Astropol (4.05 ± 0.72) < DiaComp (5.66 ± 0.62) < No Polishing (5.66 ± 0.74). Discussion: Composite polishing systems did not provide as smooth surfaces as the ceramic polishing kit for CAD-CAM leucite-reinforced ceramics. Thus, using ceramic polishing systems, polishing leucite ceramics is recommended, whereas composite polishing systems should not be considered as an alternative for use in minimally invasive dentistry.


Assuntos
Cerâmica , Resinas Compostas , Humanos , Teste de Materiais , Propriedades de Superfície
20.
Medicina (Kaunas) ; 59(5)2023 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-37241054

RESUMO

An esthetically pleasing smile is a valuable aspect of physical appearance and plays a significant role in social interaction. Achieving the perfect balance between extraoral and intraoral tissues is essential for a harmonious and attractive smile. However, certain intraoral deficiencies, such as non-carious cervical lesions and gingival recession, can severely compromise the overall aesthetics, particularly in the anterior zone. Addressing such conditions requires careful planning and meticulous execution of both surgical and restorative procedures. This interdisciplinary clinical report presents a complex case of a patient with esthetic complaints related to asymmetric anterior gingival architecture and severely discolored and eroded maxillary anterior teeth. The patient was treated using a combination of minimally invasive ceramic veneers and plastic mucogingival surgery, resulting in a successful outcome. The report emphasizes the potential of this approach in achieving optimal esthetic results in challenging cases, highlighting the importance of an interdisciplinary team approach in achieving a harmonious balance between dental and soft tissue aesthetics.


Assuntos
Retração Gengival , Transplantes , Humanos , Estética Dentária , Gengiva , Retração Gengival/cirurgia , Sorriso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA