Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Chest ; 100(4): 1164-5, 1991 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-1914583

RESUMO

The most effective treatment of severe paraquat poisoning in man is uncertain. In order to prevent pulmonary fibrosis, we employed radiotherapy of both lungs in a 23-year-old patient with severe paraquat poisoning; however, it failed to prevent the fatal outcome.


Assuntos
Paraquat/intoxicação , Fibrose Pulmonar/induzido quimicamente , Fibrose Pulmonar/radioterapia , Adulto , Humanos , Pulmão/efeitos dos fármacos , Masculino
2.
Forensic Sci Int ; 113(1-3): 353-7, 2000 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-10978648

RESUMO

Fentanyl is a very strong opioid with analgesic properties that are approximately 80 times stronger than those of morphine and therefore is used in major surgery and treatment of pain in tumor patients. Cases of fentanyl abuse by intravenous injection, inhalation, oral or nasal application have been reported especially in the USA. Therapeutic levels of fentanyl are as low as 1 ng/ml of serum and therefore a screening test must have a detection limit below that concentration. Recently three non-radioactive enzyme immunoassays (EIAs) have become commercially available from COZART, STC and DIAGNOSTIX, all of them supplied by MAHSAN Diagnostika for evaluation with serum samples from forensic and clinical cases. A calibration curve is obtained with samples that contain 0, 0.1, 0.5, 1 and 5 ng fentanyl per ml of negative serum. The calibration curve of COZART is especially in the low range, steeper than those of STC and DIAGNOSTIX. The cut-off for all these EIAs, however, can be set at 0.5 ng/ml. After the administration of therapeutic doses, fentanyl concentrations were between 3 and more than 5 ng/ml as determined with the EIAs. The presence of the typical drugs of abuse, e.g. heroin, methadone, cocaine, cannabinoids and amphetamines including the derivatives of methylenedioxyamphetamine, don't generate false-positive results. No cross-reactivity was also observed at toxic levels of benzodiazepines and paracetamol and therapeutic levels of barbiturates, phenothiazines, antidepressants and analgesics. The EIAs tested so far appear to be suitable for the detection of fentanyl at therapeutic levels. False-positive results or cross-reactivity towards other compounds have not been observed.


Assuntos
Analgésicos Opioides/sangue , Fentanila/sangue , Técnicas Imunoenzimáticas/métodos , Técnicas Imunoenzimáticas/normas , Transtornos Relacionados ao Uso de Opioides/sangue , Kit de Reagentes para Diagnóstico/normas , Detecção do Abuso de Substâncias/métodos , Calibragem , Reações Falso-Positivas , Humanos , Técnicas Imunoenzimáticas/instrumentação , Kit de Reagentes para Diagnóstico/provisão & distribuição , Sensibilidade e Especificidade
3.
Forensic Sci Int ; 113(1-3): 403-7, 2000 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-10978655

RESUMO

Active compounds of some mushrooms e.g. Psilocybe cubensis, Paneolus subalteatus or Stropharia coronilla, the psychotropic agents psilocybin and psilocin, have hallucinogenic effects. In one case of 'magic mushroom' intake, we had to analyse blood and urine. Psilocin was detected in the urine with REMEDi HS. Most of the psilocin was excreted as the glucuronide. Therefore an enzymatic hydrolysis should be the first step in analysis. Free psilocin was determined at a concentration of 0.23 mg/l while the total amount was 1.76 mg/l urine. The concentration of psilocin in serum was too low for detection with REMEDi HS. We proved a GC-MS-method with d(3)-morphine as internal standard and silylation with MSTFA. Similarly to urine, most of the psilocin in serum was found in the conjugated form. The concentration of free psilocin was 0.018 mg/l, that of total psilocin, 0.052 mg/l serum.


Assuntos
Líquidos Corporais/química , Glucuronídeos , Alucinógenos/sangue , Alucinógenos/urina , Psilocibina/análogos & derivados , Detecção do Abuso de Substâncias/métodos , Toxicologia/métodos , Cromatografia por Troca Iônica , Cromatografia Gasosa-Espectrometria de Massas , Alucinógenos/química , Humanos , Masculino , Psilocibina/sangue , Psilocibina/química , Psilocibina/urina
4.
Forensic Sci Int ; 89(3): 211-6, 1997 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-9363630

RESUMO

This is the first report in the forensic literature of a combination of fatal digoxin poisoning with endocardial fibroelastosis (EFE). Typical morphological features of EFE as the cause of clinically diagnosed cardiomyopathy were present in the autopsy of a 3-year-old girl, including cardiac hypertrophy and marked thickening of the left-sided endocardium, consisting of numerous elastic and collagenic fibres. After exclusion of cardiac and cerebral causes of death, accidental digoxin intoxication was proved. Postmortem toxicological analyses by fluorescence polarization immunoassay (FPIA) disclosed digoxin levels of 71 micrograms/kg (femoral vein blood), 77 micrograms/kg (cardiac blood), 255 and 221 micrograms/kg (cardiac muscle of the right and left chamber), 163 micrograms/kg (psoas muscle), 91 micrograms/kg (lung), 222 micrograms/kg (liver) and 520 micrograms/kg (kidney). The results are compared with the antemortem digoxin concentration of 39 ng/ml serum. The case is discussed from its unusual morphological and toxicological aspects, with special consideration of possible medical malpractice.


Assuntos
Cardiotônicos/intoxicação , Digoxina/intoxicação , Fibroelastose Endocárdica/complicações , Intoxicação/etiologia , Pré-Escolar , Fibroelastose Endocárdica/tratamento farmacológico , Fibroelastose Endocárdica/patologia , Evolução Fatal , Feminino , Humanos , Intoxicação/patologia
5.
Forensic Sci Int ; 65(1): 19-31, 1994 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8206451

RESUMO

Hypoxanthine (Hx) is a degradation product of adenosine. Increased concentrations were reported in cases of hypoxia as well as with prolonged postmortem interval (PMI). Hx is recommended as an indicator of prolonged (cerebral) hypoxia, for example in vitamins of sudden infant death as well as a new biochemical method for estimation of postmortem time. The correlation of vitreous Hx values with the time since death was reported to be even higher than the vitreous potassium (K+) values. The authors' investigations on 92 bodies with known time since death gave a completely opposite result: a much higher correlation between vitreous K+ and time since death than vitreous Hx. The possible discrepancies between these different results will be discussed (disturbing of intra-ocular fluid dynamics by repeated sample-taking in the study of Rognum et al. The results published so far on vitreous Hx values in sudden infant death syndrome (SIDS) cases as an indicator for a prolonged cerebral hypoxia are also not convincing. When vitreous concentrations of newborn infants or infants of age < 6 months are compared to those of older infants or adults the vitreous diameter must be taken into consideration (diffusion gradient; Fick's law of diffusion). The discrepant results on vitreous Hx as a measure of vital hypoxia and PMI will be discussed. The authors' results on Hx determinations on cerebrospinal fluid in comparison to cerebrospinal spinal (CSF) potassium will also be briefly addressed.


Assuntos
Hipoxantinas/análise , Hipóxia/metabolismo , Mudanças Depois da Morte , Potássio/análise , Morte Súbita do Lactente/líquido cefalorraquidiano , Corpo Vítreo/química , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Humanos , Hipoxantina , Lactente , Recém-Nascido , Pessoa de Meia-Idade
6.
Forensic Sci Int ; 132(3): 195-200, 2003 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-12711204

RESUMO

All drug-associated deaths from 1989 to 2000 were analysed at the Institute of Forensic Medicine in Cologne. Information concerning sex, gender, drug consumption, time, place and circumstances of death were analysed. A number of 605 cases were recorded; in 518 cases a toxicological analysis was possible and in 171 an autopsy was performed. When it was possible to determine the cause of death form the information available, acute drug intoxication was recorded in 65%. Heroin head the list of identified substances. Sixty-three percent of the specimens showed a combination of several substances, especially a combination of morphine, benzodiazepines, other medications and alcohol. In comparison with other studies the percentage of methadone-positive specimens is low, even though the proportion of specimens positive for methadone increased from 1989 to 2000. This analysis is discussed using background information concerning the management of substitution therapy and the available literature.


Assuntos
Heroína/intoxicação , Drogas Ilícitas/intoxicação , Metadona/intoxicação , Entorpecentes/intoxicação , Benzodiazepinas/intoxicação , Causas de Morte , Overdose de Drogas/epidemiologia , Etanol/intoxicação , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Metadona/uso terapêutico , Morfina/intoxicação , Entorpecentes/uso terapêutico , Transtornos Relacionados ao Uso de Substâncias/reabilitação
7.
Int Urol Nephrol ; 32(3): 409-12, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11583362

RESUMO

BACKGROUND: Sildenafil (Viagra) is a well-introduced medicine for erectile dysfunction; many studies about effects and side effects are published. Beside these aspects of treatment the influence of sildenafil on psychophysical performance is of interest. cGMP is one of the most important second messengers in the central nervous system (CNS), so even very small changes of the intracellular cGMP-level caused by phosphodiesterases inhibition may be relevant for CNS-function. We wanted to verify the hypothesis whether sildenfail influences human psychomotor performance, especially under the aspect of traffic safety, or not. METHODS: Designed as a pilot study we tested 6 male healthy volunteers using a test battery of 7 different psychophysical performances tests. Each individual did the test battery twice, once without drug and once after a single oral dose of 100-mg sildenafil. 3 persons did the first and 3 others did the second experiment under the influence of drug (UID). All results (37 parameters) were analysed by t-test for paired samples using a confidence interval of 95%. RESULTS: Only two parameters of 2 different tests showed significant differences. In the simple choice reaction test (DR2) the mean reaction time got better in the group with sildenafil; in the multiple choice reaction test with stress induction (RST3) the amount of wrong answers indicated a weak influence of performance without statistical significance, six parameters (dominantly in the speed anticipation test (DEST)) represented an increase and one other (RST3 second part) showed a decrease UID. The uppermost parameters (76% of all items) stayed on equal levels for both groups. CONCLUSION: Sildenafil showed no important impairment of psychophysical performance, no strong improvement was found as well. With a look at the therapeutically indication of sildenafil the improvement in sexual activity may indicate no incapacity in traffic and other psychomotoric/psychophysical functions.


Assuntos
Inibidores de Fosfodiesterase/farmacologia , Piperazinas/farmacologia , Desempenho Psicomotor/efeitos dos fármacos , Adulto , Humanos , Masculino , Projetos Piloto , Purinas , Citrato de Sildenafila , Sulfonas
8.
Blutalkohol ; 31(4): 233-7, 1994 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-7917173

RESUMO

We report on 2 road accidents where 4 people--drivers and front-seat passengers--were injured so badly that they consequently died. All four had consumed heroin, in addition to which both passengers had also consumed cocaine and dihydrocodeine respectively. The blood samples of one of the drivers was only taken after the onset of intensive medical treatment including infusions and transfusions. Nevertheless the result of the analysis clearly showed that the driving ability had been impaired by heroin. In the remaining cases the opiat concentrations were so high that they could have justified a fatal intoxication in themselves. This applies especially to one of the passengers who displayed an unconjugated morphine blood concentration of 0.96 m/l. However, also in this case at the time of the accident the blood circulation and heartbeat did not stop immediately.


Assuntos
Acidentes de Trânsito/mortalidade , Dependência de Heroína/mortalidade , Heroína/farmacocinética , Causas de Morte , Cocaína/farmacocinética , Codeína/análogos & derivados , Codeína/farmacocinética , Evolução Fatal , Heroína/intoxicação , Dependência de Heroína/sangue , Humanos , Morfina/farmacocinética , Transtornos Relacionados ao Uso de Substâncias/sangue
9.
Blutalkohol ; 30(4): 232-9, 1993 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-8373561

RESUMO

Treatment of heroin addicts with levomethadone as an alternative to the clinically performed withdrawal gains in significance more and more. Just for that reason accompanying scientific programs guided along criterions of therapy research are essential. Results of an evaluation which is to be regarded as preliminary showed no correlation between methadone plasma levels and dosage. Additional consumption of opiates, barbiturates, and benzodiazepines was observed to a high degree. The efficiency of methadone treatment is to be valued only under consideration of criterions of admission to the program as for instance a drug abuse of many years or multiple unsuccessful treatments by withdrawal.


Assuntos
Alcoolismo/sangue , Dependência de Heroína/sangue , Hipnóticos e Sedativos/farmacocinética , Metadona/farmacocinética , Detecção do Abuso de Substâncias , Transtornos Relacionados ao Uso de Substâncias/sangue , Adulto , Alcoolismo/reabilitação , Comorbidade , Relação Dose-Resposta a Droga , Feminino , Dependência de Heroína/reabilitação , Humanos , Masculino , Metadona/administração & dosagem , Transtornos Relacionados ao Uso de Substâncias/reabilitação
10.
Arch Kriminol ; 202(5-6): 165-72, 1998.
Artigo em Alemão | MEDLINE | ID: mdl-10023491

RESUMO

We compared the MTP immunoassay with EMIT for the screening of drugs of abuse (opiates, cannabinoids, cocaine metabolites and amphetamines) in whole blood samples. These blood samples were obtained from the German police, when driving under the influence of drugs of abuse was suspected. For screening with the MTP immunoassay 25 microliters of serum or blood (without any pretreatment) was pipetted into the wells of the microtiter plates and the procedure was followed as described. Prior to screening with a Cobas Mira and EMIT reagents, the samples were treated with acetone to precipitate serum proteins. The cutoff for all drugs of abuse was set at 10 ng per ml of serum or blood. In most cases there was a good agreement between the negative and positive results of the two screening assays. The agreement between the two assays in the detection of opiates and cocaine was 91% and 93%, respectively, and for cannabinoids and amphetamines approximately 80%. The MTP immunoassay was more sensitive than EMIT for the detection of cannabinoids--but at the same time the MTP immunoassay was less specific. Both screening assays have a sensitivity of 100% for the detection of opiates and cocaine, but the specificity of the EMIT--also for opiates--was substantially lower. The MTP immunoassay has in respect to amphetamines a very high sensitivity, whereas the sensitivity of EMIT for amphetamines is inacceptable due to losses during sample preparation. The specificity of MTP immunoassay for amphetamines is not optimal, because a relatively large amount of samples tested false-positive for amphetamines at the cutoff of 10 ng/ml. In summary the MTP immunoassay, although not automated, performs well in comparison with EMIT, especially if the sample preparation for EMIT testing ist considered.


Assuntos
Técnica de Imunoensaio Enzimático de Multiplicação , Drogas Ilícitas/sangue , Técnicas Imunoenzimáticas , Psicotrópicos/sangue , Detecção do Abuso de Substâncias , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Valor Preditivo dos Testes , Transtornos Relacionados ao Uso de Substâncias/sangue , Transtornos Relacionados ao Uso de Substâncias/diagnóstico
11.
Arch Kriminol ; 193(1-2): 1-9, 1994.
Artigo em Alemão | MEDLINE | ID: mdl-8147698

RESUMO

7 cases of "dumping" of the bodies of drug addicts are reported. Circumstances of the case, findings at the scene, autopsy findings and confessions raised already the suspicion that the bodies were not found at the scene of death. In 5 cases the "dumping" of the bodies was outside, in 2 cases inside a house. Identification of the bodies was always easy, since personal papers (passport, identity card) were still present and no attempts were made to prevent identification. The prevalent motivation for "dumping" seems to be not to be identified as drug addict or dealer or to be brought in connection with the death of drug addicts.


Assuntos
Overdose de Drogas/patologia , Drogas Ilícitas/intoxicação , Psicotrópicos/intoxicação , Transtornos Relacionados ao Uso de Substâncias/patologia , Adulto , Autopsia , Causas de Morte , Feminino , Heroína/farmacocinética , Heroína/intoxicação , Dependência de Heroína/patologia , Humanos , Drogas Ilícitas/farmacocinética , Masculino , Psicotrópicos/farmacocinética , Distribuição Tecidual
12.
Arch Kriminol ; 206(3-4): 82-7, 2000.
Artigo em Alemão | MEDLINE | ID: mdl-11126588

RESUMO

A fatal intoxication of a 22-year-old woman after intake of the phenothiazine perazine is described. In all of investigated organs e.g. in liver, lungs and kidneys high concentrations of the active agent could be found. The analytical results lead to the assumption that at least 14, most likely 30 tablets of Taxilan 100 have been taken. An unintended overdosage seems to be excluded just as an administration by another person.


Assuntos
Overdose de Drogas/diagnóstico , Perazina/intoxicação , Intoxicação/diagnóstico , Suicídio/legislação & jurisprudência , Adulto , Diagnóstico Diferencial , Overdose de Drogas/sangue , Feminino , Humanos , Perazina/farmacocinética , Intoxicação/sangue , Esquizofrenia Paranoide/sangue , Esquizofrenia Paranoide/tratamento farmacológico , Suicídio/psicologia , Distribuição Tecidual
13.
Arch Kriminol ; 202(3-4): 75-80, 1998.
Artigo em Alemão | MEDLINE | ID: mdl-9856274

RESUMO

A man with indications of autoerotic manipulations was found dead in his flat and a homicide had to be excluded. Diverse material found in the flat suggested that the man was a consumer of cocaine. But the analyses of blood, urine and organs showed high concentrations of amphetamine and it was thought about an unintentionally mix-up with cocaine. A hair analysis was made and only amphetamine was detected. Therefore the utensils (mirror, razor-blade and sniff-pipe) belong to a rare nasal consumption of amphetamine.


Assuntos
Acidentes/legislação & jurisprudência , Anfetamina/intoxicação , Overdose de Drogas/diagnóstico , Masturbação , Adulto , Anfetamina/farmacocinética , Diagnóstico Diferencial , Overdose de Drogas/sangue , Humanos , Masculino
14.
Arch Kriminol ; 203(1-2): 40-4, 1999.
Artigo em Alemão | MEDLINE | ID: mdl-10198695

RESUMO

The authors report on a 21-year old female who died suddenly during a techno-festival. The autopsy findings and the results of chemical-toxicological analyses were not able to clear up the cause of death. Pathophysiological and toxicological considerations demonstrate that only a combination of facts are sufficient to explain the sudden death of this young woman.


Assuntos
Analgésicos Opioides/intoxicação , Codeína/análogos & derivados , Morfina/intoxicação , Transtornos Relacionados ao Uso de Substâncias/mortalidade , Adulto , Codeína/intoxicação , Evolução Fatal , Feminino , Humanos
17.
Z Rechtsmed ; 85(3): 169-75, 1980.
Artigo em Alemão | MEDLINE | ID: mdl-7415572

RESUMO

Concentrations of brallobarbital and secobarbital in 10 cases of acute Vesparax-intoxications are listed for blood, brain, liver, kidney, and muscle. Quantitative determinations in brain give information as to the time of acute poisoning. Muscle is a suitable organ to determine the resorbed quantity of the drug. As few as 10 Vesparax-tablets are enough to produce lethal poisonings.


Assuntos
Barbitúricos/intoxicação , Adulto , Barbitúricos/metabolismo , Feminino , Medicina Legal , Humanos , Masculino , Pessoa de Meia-Idade , Suicídio , Distribuição Tecidual
18.
Z Rechtsmed ; 81(4): 269-83, 1978 Aug 28.
Artigo em Alemão | MEDLINE | ID: mdl-28618

RESUMO

Concentrations of carbromal, carbromide and bromisoval are determined in blood, urine, brain, kidney and muscle taken at autopsy from 41 fatal cases after overdosage of bromureides. In addition values of total bromine in blood are presented. Contents of total bromine can only lead to the deduction that a chronical abuse of bromureides is existent or not. Concentrations of bromureides and carbromide show a wide range according to the different time between taking the drug and death particularly in cases of pure carbromal intoxications which sometimes cause death after several days. In such cases quantitative determination of carbromide, a pharmacologically active metabolite of carbromal, is the only way to prove an acute carbromal intoxication. Especially in cases of additional foreign substances death may occur in early the phase of poisoning. Bromureides decompose post mortem by putrefaction a high degree so that the condition of the cadaver is important. Brain tissue is the most usable material for examination but other organs, particularly muscle and kidney, can be analysed with success. For differential diagnosis fatal cases are presented which were not caused by drug intake.


Assuntos
Cadáver , Ureia/análise , Química Encefálica , Bromo/sangue , Bromisoval/análise , Bromisoval/sangue , Bromisoval/urina , Medicina Legal , Humanos , Rim/análise , Músculos/análise , Intoxicação/metabolismo , Ureia/sangue , Ureia/urina
19.
Arch Toxicol ; 35(4): 263-73, 1976 Aug 18.
Artigo em Alemão | MEDLINE | ID: mdl-9051

RESUMO

Isolation of three bromine containing metabolites from human urine is described and their chemical structure is proved by comparison of their physical properties with those of synthetically prepared substances. 2-Bromo-2-ethyl-butyramide, a pharmacologically active product, is showed to be the most important bromine containing metabolite by volume. In 3-position hydroxylated metabolites of carbromal, 3-hydroxy-carbromal and 2-Bromo-2-ethyl-3-hydroxy-butyramide have same physical properties as the synthesized DL-threo--diastereomeres.


Assuntos
Ureia/urina , Bromo/urina , Humanos , Hidroxilação , Conformação Molecular , Análise Espectral , Estereoisomerismo
20.
Beitr Gerichtl Med ; 48: 51-6, 1990.
Artigo em Alemão | MEDLINE | ID: mdl-2241837

RESUMO

150 urine samples which we received from the criminal investigation department were measured with EMIT cannabis 20 and EMIT cannabis 50 reagents by EMIT Autolabsystem and especially with the immunoassay analyzer ETS by Syva Diagnostica. The confirming analyses were performed by GC-MS. If only cases are considered which are positive with cannabis 20 containing at least 10 ng 11-Nor-delta-9-THC-9-carboxylic acid in urine, there will be a negative result of 18.8% with EMIT 50. This appears to be unreasonably high. Some of these cases were also tested with Abuscreen ONTRAK-reagents. With this method the cut off for cannabis with 100 ng/ml urine is far too high but can be lowered essentially by taking a larger urine sample.


Assuntos
Canabinoides/farmacocinética , Técnicas Imunoenzimáticas/instrumentação , Abuso de Maconha/diagnóstico , Processamento de Sinais Assistido por Computador/instrumentação , Humanos , Abuso de Maconha/urina
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA