Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Phys Eng Sci Med ; 46(1): 57-66, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36454430

RESUMO

HyperArc™ is a stereotactic radiotherapy modality designed for targeting multiple brain metastases using a single isocenter with multiple non-coplanar arcs. This study aimed to assess the efficacy of two patient-specific quality assurance methods, film and the Varian Portal Dosimetry System with Varian's HyperArc™ technique and raise important considerations in the customisation of patient-specific quality assurance to accommodate HyperArc™ delivery. Assessment criteria included gamma analysis and mean dose at full width half maximum. The minimum metastasis size, maximum off-axis distance and suitable energy were identified and validated. Patient-specific quality assurance procedures were applied to a range of clinically relevant brain metastasis plans. Initial investigation into energy selection showed no significant differences in gamma pass rates using 6MV, 6MV FFF, or 10MV FFF for metastasis sizes greater than 15 mm diameter at the isocenter. Gamma pass rates (2%/2mm) for 15 mm metastases at the isocenter for all energies were greater than 96.0% for portal dosimetry and greater than 98.7% for film. Fields of size 15 mm placed at various distances (10-70 mm) from the isocenter resulted in a maximum mean dose difference of 1.5% between film and planned. Clinically relevant plans resulted in a maximum mean dose difference for selected metastases of 1.0% between film and plan and a maximum point dose difference of 2.9% between portal dose and plan. Portal dose image prediction was a quick and convenient quality assurance tool for metastases larger than 15 mm near the isocenter but provided diminished geometrical relevance for off-axis metastases. Film QA required exacting procedures but offered the ability to assess the accuracy of geometrical targeting for off-axis metastases and provided dosimetric accuracy for metastases to well below 15 mm diameter.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Radiometria , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA