Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Bone Jt Open ; 5(2): 132-138, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38346449

RESUMO

Aims: The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury. Methods: Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient's initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed. Results: Patients treated with surgical fixation with wires had less dorsal angulation of the radius versus those treated in a moulded cast at six weeks after manipulation of the fracture; the mean difference of -4.13° was statistically significant (95% confidence interval 5.82 to -2.45). There was no evidence of a difference in radial shortening. However, there was no correlation between these radiological measurements and PROMs at any timepoint in the 12 months post-injury. Conclusion: For patients with a dorsally displaced distal radius fracture treated with a closed manipulation, surgical fixation with wires leads to less dorsal angulation on radiographs at six weeks compared with patients treated in a moulded plaster cast alone. However, the difference in dorsal angulation was small and did not correlate with patient-reported pain and function.

2.
Hip Int ; 32(3): 401-406, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-32905712

RESUMO

INTRODUCTION: Osteoporotic acetabular fractures are common and pose a difficult technical challenge for the trauma surgeon. Acute total hip arthroplasty (THA) using a Burch-Schneider antiprotrusio cage with immediate postoperative weight-bearing is a method to approach these injuries. This case series reports our outcomes of acute THA using Burch-Schneider cages for acetabular fractures from a UK major trauma centre based on length of stay, radiological outcome, complications and outcome scores. METHODS: Data were collected from all patients who underwent acute THA with a Burch-Schneider cage for acetabular fractures between June 2006 and August 2015. Patients were followed up clinically, radiologically, and using Oxford Hip Scores (OHS). RESULTS: 20 patients with a median age of 73 (range 60-90 years) were identified. All patients were independent walkers at follow-up, and had achieved radiological union. There were no dislocations, subsidence, revision or deep infections. Significant complications include 1 perioperative death as a result of complications arising from pre-existing pulmonary fibrosis; 1 deep vein thrombosis; 1 intraoperative arterial injury to the superior gluteal artery; and 1 leg-length discrepancy. Mean length of stay was 10 days. The mean OHS was 37/48 at a mean follow-up of 26 months. CONCLUSIONS: This case series further validates the use of Burch-Schneider cages with primary THA in acute acetabular fractures.


Assuntos
Artroplastia de Quadril , Fraturas do Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/lesões , Acetábulo/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Seguimentos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/etiologia , Fraturas do Quadril/cirurgia , Humanos , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
3.
Injury ; 52(10): 2725-2729, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32107009

RESUMO

INTRODUCTION: Anterior pubic symphyseal plate fixation is the recommended treatment for disruption of pubic symphysis in an unstable pelvic ring injury. The rigid construct offered by locking symphyseal plate has the theoretical advantage of allowing patients to weight bear early. However, there are concerns of catastrophic failure about the locked plate construct. The purpose of the study was to establish if locking plate fixation for pubic symphysis disruption was effective to allow patients to mobilise weight bearing immediately after surgery. PATIENT AND METHODS: Retrospective analysis of a prospectively collected database from a single centre was performed. The study period was from 2008 to 2017. Radiographic evidence of fixation failure, revision surgery, removal of metalwork and follow up duration was noted. RESULTS: We identified 46 patients (F:M 8:38) with a mean age of 46 years (range 14 to 74 years). Based on the mechanism of injury patients were classified into Antero-posterior compression (28), Vertical shear [10], lateral compression [4] and combined mechanism [4]. Either a 4-hole or 6-hole locking plate was used in all patients, depending on fracture extension. Posterior fixation was required in 28 (61%) patients. All patients were allowed to fully or partial weight bear. The mean radiological follow-up period was 31 weeks with 13 (28%) patients having evidence of radiological failure. Revision was performed in 1 (2%) patient, in whom the screws had pulled out of the bone. The most common mode of failure was either the screw backing out from the plate or broken screw. Among the 4 (8%) patients who had their metalwork removed, 1 (2%) had delayed onset of infection, 2 (4%) had symptoms related to backed out screw and 1 (2%) opted electively to have metalwork removed. CONCLUSIONS: With our series of patients, we have found that using locking plate for pubic symphyseal diastasis is safe and effective in allowing patients to weight bear early. A low complication rate and need for re-operation is demonstrated.


Assuntos
Fixação Interna de Fraturas , Diástase da Sínfise Pubiana , Adolescente , Adulto , Idoso , Placas Ósseas , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Suporte de Carga , Adulto Jovem
4.
Bone Joint J ; 103-B(8): 1333-1338, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34334038

RESUMO

AIMS: Reverse total shoulder arthroplasty (RTSA) using trabecular metal (TM)-backed glenoid implants has been introduced with the aim to increase implant survival. Only short-term reports on the outcomes of TM-RTSA have been published to date. We aim to present the seven-year survival of TM-backed glenoid implants along with minimum five-year clinical and radiological outcomes. METHODS: All consecutive elective RTSAs performed at a single centre between November 2008 and October 2014 were reviewed. Patients who had primary TM-RTSA for rotator cuff arthropathy and osteoarthritis with deficient cuff were included. A total of 190 shoulders in 168 patients (41 male, 127 female) were identified for inclusion at a mean of 7.27 years (SD 1.4) from surgery. The primary outcome was survival of the implant with all-cause revision and aseptic glenoid loosening as endpoints. Secondary outcomes were clinical, radiological, and patient-related outcomes with a five-year minimum follow-up. RESULTS: The implant was revised in ten shoulders (5.2%) with a median time to revision of 21.2 months (interquartile range (IQR) 9.9 to 41.8). The Kaplan-Meier survivorship estimate at seven years was 95.9% (95% confidence interval (CI) 91.7 to 98; 35 RTSAs at risk) for aseptic mechanical failure of the glenoid and 94.8% (95% CI 77.5 to 96.3; 35 RTSAs at risk) for all-cause revision. Minimum five-year clinical and radiological outcomes were available for 103 and 98 RTSAs respectively with a median follow-up time of six years (IQR 5.2 to 7.0). Median postoperative Oxford Shoulder Score was 38 (IQR 31 to 45); median Constant and Murley score was 60 (IQR 47.5 to 70); median forward flexion 115° (IQR 100° to 125°); median abduction 95° (IQR 80° to 120°); and external rotation 25° (IQR 15° to 40°) Scapular notching was seen in 62 RTSAs (63.2%). CONCLUSION: We present the largest and longest-term series of TM-backed glenoid implants demonstrating 94.8% all-cause survivorship at seven years. Specifically pertaining to glenoid loosening, survival of the implant increased to 95.9%. In addition, we report satisfactory minimum five-year clinical and radiological outcomes. Cite this article: Bone Joint J 2021;103-B(8):1333-1338.


Assuntos
Artroplastia do Ombro/métodos , Placas Ósseas , Falha de Prótese , Escápula/cirurgia , Prótese de Ombro , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Desenho de Prótese , Radiografia , Estudos Retrospectivos , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA