Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 118(14): 141803, 2017 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-28430473

RESUMO

We present direct detection constraints on the absorption of hidden-photon dark matter with particle masses in the range 1.2-30 eV c^{-2} with the DAMIC experiment at SNOLAB. Under the assumption that the local dark matter is entirely constituted of hidden photons, the sensitivity to the kinetic mixing parameter κ is competitive with constraints from solar emission, reaching a minimum value of 2.2×10^{-14} at 17 eV c^{-2}. These results are the most stringent direct detection constraints on hidden-photon dark matter in the galactic halo with masses 3-12 eV c^{-2} and the first demonstration of direct experimental sensitivity to ionization signals <12 eV from dark matter interactions.

2.
Rev Sci Instrum ; 79(2 Pt 1): 024902, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18315322

RESUMO

A new spectroradiometry system specialized for measuring two-dimensional temperature gradients for samples at high pressure in the laser heated diamond anvil cell has been designed and constructed at UCLA. Emitted light intensity from sample hotspots is imaged by a videocamera for real time monitoring, an imaging spectroradiometer for temperature measurement, and a high-dynamic-range camera that examines a magnified image of the two-dimensional intensity distribution of the heated spot, yielding precise measurements of temperature gradients. With this new system, most systematic errors in temperature measurement due to chromatic aberration are bypassed. We use this system to compare several different geometries of temperature measurement found in the literature, including scanning a pinhole aperture, and narrow-slit and wide-slit entrance apertures placed before the imaging spectrometer. We find that the most accurate way of measuring a temperature is to use the spectrometer to measure an average hotspot temperature and to use information from the imaging charge coupled device to calculate the temperature distribution to the hotspot. We investigate the effects of possible wavelength- and temperature-dependent emissivity, and evaluate their errors. We apply this technique to measure the anisotropy in temperature distribution of highly oriented graphite at room temperature and also at high pressures. A comparison between model and experiment demonstrates that this system is capable of measuring thermal diffusivity in anisotropic single crystals and is also capable of measuring relative thermal diffusivity at high pressures and temperatures among different materials. This shows the possibility of using this system to provide information about thermal diffusivity of materials at high pressure and temperature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA