Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Surg Endosc ; 26(1): 249-54, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21853390

RESUMO

BACKGROUND: Mesh reinforcement has become the standard of care in the open and laparoscopic repair of inguinal hernia. Chronic pain after inguinal hernia repair is often due to nerve injury by penetrating mesh fixation devices such as staples (ST), tacks, or sutures. In several studies on hernioplasty, atraumatic mesh fixation with fibrin sealant (FS) proved to be efficient in terms of fixation strength and elasticity. Unfortunately, most of these studies did not provide a standardized follow-up and assessment of the development of chronic pain (CP) and the quality of life (QoL). Therefore, a randomized controlled trial comparing CP and QoL after FS fixation of mesh with ST in transabdominal preperitoneal hernioplasty (TAPP) was performed at our department. The primary end point of our study was to assess the patient outcome by using a visual analog scale (VAS) and the short form 36 (SF-36). The evaluation of recurrence rates was the secondary aim. METHODS: According to the randomization, a macroporous mesh (TiMESH(®)) was fixed in group A (44 patients with 54 inguinal hernias) with FS (TISSEEL) or in group B (45 patients with 56 inguinal hernias) with ST (EMS(®) Stapler). The observation period was 1 year with regular clinical check ups and assessment of VAS and SF-36. RESULTS: Patient characteristics expressed by BMI, ASA scores, and Schumpelick hernia classification were similar in both treatment groups. In each group there was one recurrence within 8 (FS) and 9 months (ST) postsurgery. The mean preoperative pain values scored by VAS were 1.7 (range = 0-7.5) in the FS group and 2.2 (range = 0-6) in the ST group. Postoperative mean VAS scores measured at 1 year postsurgery were 0.4 (range = 0-3) in the FS group and 0.9 (range = 0-7.5) in the ST group. One year postsurgery there was no significant difference between the two groups with respect to the parameter pain in the SF-36 and VAS. CONCLUSION: Fibrin sealant fixation leads to a low rate of hernia recurrence and avoids tissue trauma. ST provide similar results in the hand of the expert but bear inherent risks of complications due to tissue perforation.


Assuntos
Adesivo Tecidual de Fibrina/uso terapêutico , Hérnia Inguinal/cirurgia , Herniorrafia/métodos , Telas Cirúrgicas , Grampeamento Cirúrgico/métodos , Adesivos Teciduais/uso terapêutico , Adulto , Dor Crônica/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Recidiva , Resultado do Tratamento
2.
Radiologe ; 36(12): 981-90, 1996 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-9082480

RESUMO

The influence of biomechanics in surgery of the locomotor apparatus has been constantly increasing over the last few decades. The purpose of this study was to determine wether biomechanical studies can significantly influence therapy and treatment of shoulder injuries, especially shoulder instability. The investigation was performed on 23 fresh human specimens with intact capsular ligaments of the glenohumeral joint. A Bankart lesion from 3 o'clock to 6 o'clock was repaired, and a Bankart repair and anterior inferior capsular shift, as described by Neer, were performed. The measurement was done on six clinically relevant positions of instability: superior, anterior, anterior-inferior, inferior, posterior-inferior, posterior. Measurement was done using a specially developed strain-gauge system. It was demonstrated that both instability and too much stability of the shoulder joint lead to a significant change in shoulder biomechanics. The anatomical O-position of the glenohumeral joint in 110 degrees of abduction is a position of about 60 degrees of external rotation compared to the O-position for clinical measurement. From the therapy point of view, one has to ask for anatomical reconstruction instead of tight repair in soft-tissue repair in the glenohumeral joint. Immediate post-operative rehabilitation in a 60 degrees range of motion is possible.


Assuntos
Instabilidade Articular/fisiopatologia , Lesões do Manguito Rotador , Luxação do Ombro/fisiopatologia , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Humanos , Instabilidade Articular/cirurgia , Ligamentos Articulares/lesões , Ligamentos Articulares/fisiopatologia , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia , Valores de Referência , Manguito Rotador/fisiopatologia , Manguito Rotador/cirurgia , Luxação do Ombro/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA