Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 341
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 614(7946): 88-94, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36653458

RESUMO

Two-dimensional (2D) materials and their heterostructures show a promising path for next-generation electronics1-3. Nevertheless, 2D-based electronics have not been commercialized, owing mainly to three critical challenges: i) precise kinetic control of layer-by-layer 2D material growth, ii) maintaining a single domain during the growth, and iii) wafer-scale controllability of layer numbers and crystallinity. Here we introduce a deterministic, confined-growth technique that can tackle these three issues simultaneously, thus obtaining wafer-scale single-domain 2D monolayer arrays and their heterostructures on arbitrary substrates. We geometrically confine the growth of the first set of nuclei by defining a selective growth area via patterning SiO2 masks on two-inch substrates. Owing to substantial reduction of the growth duration at the micrometre-scale SiO2 trenches, we obtain wafer-scale single-domain monolayer WSe2 arrays on the arbitrary substrates by filling the trenches via short growth of the first set of nuclei, before the second set of nuclei is introduced, thus without requiring epitaxial seeding. Further growth of transition metal dichalcogenides with the same principle yields the formation of single-domain MoS2/WSe2 heterostructures. Our achievement will lay a strong foundation for 2D materials to fit into industrial settings.

2.
Nature ; 614(7946): 81-87, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36725999

RESUMO

Micro-LEDs (µLEDs) have been explored for augmented and virtual reality display applications that require extremely high pixels per inch and luminance1,2. However, conventional manufacturing processes based on the lateral assembly of red, green and blue (RGB) µLEDs have limitations in enhancing pixel density3-6. Recent demonstrations of vertical µLED displays have attempted to address this issue by stacking freestanding RGB LED membranes and fabricating top-down7-14, but minimization of the lateral dimensions of stacked µLEDs has been difficult. Here we report full-colour, vertically stacked µLEDs that achieve, to our knowledge, the highest array density (5,100 pixels per inch) and the smallest size (4 µm) reported to date. This is enabled by a two-dimensional materials-based layer transfer technique15-18 that allows the growth of RGB LEDs of near-submicron thickness on two-dimensional material-coated substrates via remote or van der Waals epitaxy, mechanical release and stacking of LEDs, followed by top-down fabrication. The smallest-ever stack height of around 9 µm is the key enabler for record high µLED array density. We also demonstrate vertical integration of blue µLEDs with silicon membrane transistors for active matrix operation. These results establish routes to creating full-colour µLED displays for augmented and virtual reality, while also offering a generalizable platform for broader classes of three-dimensional integrated devices.

3.
Hepatology ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38739848

RESUMO

BACKGROUND AND AIMS: A new term, metabolic dysfunction-associated steatotic liver disease (MASLD), has been proposed by a multi-society expert panel. However, it remains unclear whether hepatic steatosis per se in MASLD contributes to an increased risk of mortality in individuals with any cardio-metabolic risk factor (CMRF), which is also a significant risk factor for increased mortality. This study aimed to compare all-cause and cause-specific mortality between the "MASLD/MetALD" and "no steatotic liver disease (SLD)" groups in individuals with any CMRF. APPROACH AND RESULTS: A population-based cohort study was conducted using 10,750 participants of the Third National Health and Nutrition Examination Survey. All-cause and cause-specific (cardiovascular, cancer, diabetes, and liver) mortality risks were compared between the "MASLD," "MetALD," and "no SLD" groups using the Cox proportional hazards model with complex survey design weights, adjusted for confounders. Over 26 years, the "MASLD" group did not show significantly increased all-cause (adjusted HR 1.04[95% CI: 0.95-1.14], p = 0.413), cardiovascular (0.88 [0.75-1.04], p = 0.139), or cancer (1.06[0.84-1.33], p = 0.635) mortality risk compared to the "no SLD" group in individuals with any CMRF. The MetALD group was associated with increased all-cause (1.41 [1.05-1.89], p = 0.022), cancer (2.35 [1.33-4.16], p = 0.004), and liver (15.04 [2.96-76.35], p = 0.002) mortality risk compared with the no SLD group. This trend was more pronounced in the MetALD group with advanced fibrosis assessed by Fibrosis-4 (FIB-4). CONCLUSIONS: In individuals with CMRF, the presence of steatotic liver disease (MASLD) alone did not increase the risk of mortality, except in cases with more alcohol consumption (MetALD). Therefore controlling metabolic risk factors and reducing alcohol consumption in people with MASLD or MetALD will be crucial steps to improve long-term health outcomes.

4.
Nano Lett ; 24(10): 2939-2952, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38477054

RESUMO

Advanced heterogeneous integration technologies are pivotal for next-generation electronics. Single-crystalline materials are one of the key building blocks for heterogeneous integration, although it is challenging to produce and integrate these materials. Remote epitaxy is recently introduced as a solution for growing single-crystalline thin films that can be exfoliated from host wafers and then transferred onto foreign platforms. This technology has quickly gained attention, as it can be applied to a wide variety of materials and can realize new functionalities and novel application platforms. Nevertheless, remote epitaxy is a delicate process, and thus, successful execution of remote epitaxy is often challenging. Here, we elucidate the mechanisms of remote epitaxy, summarize recent breakthroughs, and discuss the challenges and solutions in the remote epitaxy of various material systems. We also provide a vision for the future of remote epitaxy for studying fundamental materials science, as well as for functional applications.

5.
Nat Mater ; 22(12): 1470-1477, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38012388

RESUMO

Three-dimensional (3D) hetero-integration technology is poised to revolutionize the field of electronics by stacking functional layers vertically, thereby creating novel 3D circuity architectures with high integration density and unparalleled multifunctionality. However, the conventional 3D integration technique involves complex wafer processing and intricate interlayer wiring. Here we demonstrate monolithic 3D integration of two-dimensional, material-based artificial intelligence (AI)-processing hardware with ultimate integrability and multifunctionality. A total of six layers of transistor and memristor arrays were vertically integrated into a 3D nanosystem to perform AI tasks, by peeling and stacking of AI processing layers made from bottom-up synthesized two-dimensional materials. This fully monolithic-3D-integrated AI system substantially reduces processing time, voltage drops, latency and footprint due to its densely packed AI processing layers with dense interlayer connectivity. The successful demonstration of this monolithic-3D-integrated AI system will not only provide a material-level solution for hetero-integration of electronics, but also pave the way for unprecedented multifunctional computing hardware with ultimate parallelism.

6.
Osteoporos Int ; 35(4): 635-644, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38095696

RESUMO

Periodontal disease and increased missing teeth were associated with incident vertebral fractures. In contrast, professional dental cleaning and frequent tooth brushing, was associated with a lower risk of vertebral fracture. Better oral hygiene care attenuated the risk associated with dental diseases. PURPOSE: To investigate the association between oral health and the risk of vertebral fractures. METHODS: We included 2,532,253 individuals aged ≥40 years who underwent the Korean National Health Insurance Service health examinations in 2008 and followed up until December 31, 2017. We performed multivariable Cox proportional hazard regression analyses to evaluate the association between dental diseases and oral hygiene care and the risk of vertebral fractures. RESULTS: Over the 9.3-year median follow-up, 1.46% (n = 36,857) experienced vertebral fractures. Individuals with dental diseases had a higher risk of vertebral fracture than those without (hazard ratio [HR] 1.04, 95% confidence interval [CI]: 1.02-1.07 for periodontal diseases; 1.02, 1.00-1.05 for dental caries; 1.12, 1.05-1.20 for ≥15 missing teeth). Good oral hygiene care was associated with a lower vertebral fracture risk (HR 0.89, 95% CI: 0.86-0.91 for ≥1 time/year [vs. <1 time/year] of professional dental cleaning; 0.90, 0.87-0.93 for ≥2 times/day [vs. 0-1 time/day] of toothbrushing). The combined dental diseases was significantly associated with an increased vertebral fracture risk, whereas combined oral hygiene care was associated with further risk reduction. Better oral hygiene care reduced vertebral fracture risk associated with dental diseases (all P <0.001). CONCLUSION: Periodontal disease, dental caries, and an increased number of missing teeth were independently associated with higher risks for vertebral fractures. Conversely, improved oral hygiene care, such as personal dental cleaning and frequent tooth brushing, may modify vertebral fracture risks associated with dental disease.


Assuntos
Cárie Dentária , Doenças Periodontais , Fraturas da Coluna Vertebral , Humanos , Higiene Bucal , Estudos de Coortes , Fraturas da Coluna Vertebral/epidemiologia , Fraturas da Coluna Vertebral/etiologia , Doenças Periodontais/complicações , Doenças Periodontais/epidemiologia
7.
Clin Gastroenterol Hepatol ; 21(4): 1111-1113.e3, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35276326

RESUMO

The comparative effectiveness of tenofovir (TDF) vs entecavir (ETV) in reducing the risk of hepatocellular carcinoma (HCC) in patients with chronic hepatitis B virus (HBV) remains unclear. Data from a retrospective Korean cohort study published by Choi et al1 initially suggested a lower-than-expected incidence of HCC in patients on long-term TDF. However, additional studies from Korea did not show a statistically significant difference in HCC incidence rate between TDF and ETV groups,2,3 and subsequent studies reported mixed results ranging from no association or a slight advantage for TDF.4 Most of these studies examined Asian patients from Korea, Taiwan, and China.


Assuntos
Carcinoma Hepatocelular , Hepatite B Crônica , Neoplasias Hepáticas , Humanos , Tenofovir/uso terapêutico , Carcinoma Hepatocelular/etiologia , Hepatite B Crônica/complicações , Hepatite B Crônica/tratamento farmacológico , Vírus da Hepatite B , Antivirais/uso terapêutico , Estudos de Coortes , Estudos Retrospectivos , Neoplasias Hepáticas/etiologia , Resultado do Tratamento
8.
Clin Gastroenterol Hepatol ; 21(4): 1023-1030.e39, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35680035

RESUMO

BACKGROUND & AIMS: Cirrhosis is the main predisposing condition for hepatocellular carcinoma. Host genetic risk factors have been reported for cirrhosis; however, whether there is a genetic contribution to racial disparities in cirrhosis requires further investigation. METHODS: We used an affected-only mapping by admixture linkage disequilibrium analysis to characterize the genetic risk of cirrhosis in 227 African American patients with cirrhosis genotyped at 19,804 ancestry-informative marker single nucleotide polymorphisms. We additionally performed analyses stratified by hepatitis C virus (HCV) infection status. To replicate our findings, we conducted a case-control analysis in an external study population (452 cases and 196 controls). RESULTS: The mean age of patients was 63.3 years and 98.2% were male. Risk factors for cirrhosis included HCV infection (83.7%) and alcohol abuse (56.4%). In the admixture mapping analysis, we found that European ancestry on chromosome 2q21.1 and African ancestry on chromosome 6p21.2 were associated with increased risk of cirrhosis in African Americans. In the fine-mapping analysis, we identified regions near POTEKP on 2q21.1 (P = .0001) and DNAH8 on 6p21.2 (P = .0017) that were associated with cirrhosis. As the admixture peaks in the HCV-positive patients were the same as those in the overall group, findings in the analysis are reflective of the HCV-positive group. In the replication analysis, the results on chromosome 2 were not significant after adjusting for multiple comparisons, and we could not replicate the results on chromosome 6. CONCLUSIONS: We used admixture mapping to identify novel genomic regions on 2q21.1 and 6p21.2 that may be associated with HCV-related cirrhosis risk in African Americans.


Assuntos
Negro ou Afro-Americano , Hepatite C , Cirrose Hepática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Negro ou Afro-Americano/genética , Mapeamento Cromossômico/métodos , Genótipo , Hepacivirus , Hepatite C/complicações , Hepatite C/genética , Cirrose Hepática/genética , Cirrose Hepática/virologia , Polimorfismo de Nucleotídeo Único
9.
Small ; 19(8): e2205881, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36504329

RESUMO

Two-dimensional layered transition metal dichalcogenides have emerged as promising materials for supercapacitors and hydrogen evolution reaction (HER) applications. Herein, the molybdenum sulfide (MoS2 )@vanadium sulfide (VS2 ) and tungsten sulfide (WS2 )@VS2  hybrid nano-architectures prepared via a facile one-step hydrothermal approach is reported. Hierarchical hybrids lead to rich exposed active edge sites, tuned porous nanopetals-decorated morphologies, and high intrinsic activity owing to the strong interfacial interaction between the two materials. Fabricated supercapacitors using MoS2 @VS2  and WS2 @VS2  electrodes exhibit high specific capacitances of 513 and 615 F g- 1 , respectively, at an applied current of 2.5 A g- 1  by the three-electrode configuration. The asymmetric device fabricated using WS2 @VS2  electrode exhibits a high specific capacitance of 222 F g- 1  at an applied current of 2.5 A g- 1  with the specific energy of 52 Wh kg- 1  at a specific power of 1 kW kg- 1 . For HER, the WS2 @VS2  catalyst shows noble characteristics with an overpotential of 56 mV to yield 10 mA cm- 2 , a Tafel slope of 39 mV dec-1 , and an exchange current density of 1.73 mA cm- 2 . In addition, density functional theory calculations are used to evaluate the durable heterostructure formation and adsorption of hydrogen atom on the various accessible sites of MoS2 @VS2  and WS2 @VS2  heterostructures.

10.
Opt Lett ; 48(4): 992-995, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36790997

RESUMO

We present spectrometer-based wavelength interrogation surface plasmon resonance imaging (SPRi) without mechanical scanning. A polarized broadband light source illuminates an object via a gold-coated prism; the reflected light is spatially modulated by a digital mirror device (DMD) and then measured with a spectrometer. Reflectance spectral images are reconstructed via the Hadamard transform (HT), and a refractive index (RI) map is visualized from the reflectance spectral images by analyzing the resonance peak shift of the spectrum at each image pixel. We demonstrate the feasibility of our method by evaluating the resolution, sensitivity, and dynamic detection range, experimentally obtained as ∼2.203 × 10-6 RI unit (RIU), ∼3,407 nm/RIU, and ∼0.1403 RIU, respectively. Furthermore, simulations are performed to validate the experimental results.

11.
Environ Res ; 226: 115660, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36913997

RESUMO

Eco-friendly renewable energy sources have recommended as fossil fuel alternatives in recent years to reduce environmental pollution and meet future energy demands in various sectors. As the largest source of renewable energy in the world, lignocellulosic biomass has received considerable interest from the scientific community to advance the fabrication of biofuels and ultrafine value-added chemicals. For example, biomass obtained from agricultural wastes could catalytically convert into furan derivatives. Among furan derivatives, 5-hydroxymethylfurfural (HMF) and 2, 5-dimethylfuran (DMF) are considered the most useful molecules that can be transformed into desirable products such as fuels and fine chemicals. Because of its exceptional properties, e.g., water insolubility and high boiling point, DMF has studied as the ideal fuel in recent decades. Interestingly, HMF, a feedstock upgraded from biomass sources can easily hydrogenate to produce DMF. In the present review, the current state of the art and studies on the transformation of HMF into DMF using noble metals, non-noble metals, bimetallic catalysts, and their composites have discussed elaborately. In addition, comprehensive insights into the operating reaction conditions and the influence of employed support over the hydrogenation process have demonstrated.


Assuntos
Biocombustíveis , Lignina , Biomassa , Lignina/química , Furanos
12.
Sensors (Basel) ; 23(3)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36772688

RESUMO

In this study, a 0-3 piezoelectric composite based on lead zirconate-titanate (PZT)/polyvinyl-butyral (PVB) was fabricated and characterized for its potential application in tactile sensing. The 0-3 composite was developed to incorporate the advantages of both ceramic and polymer. The paste of 0-3 PZT-PVB composite was printed using a conventional screen-printing technique on alumina and mylar substrates. The thickness of the prepared composite was approximately 80 µm. After printing the top electrode of the silver paste, 10 kV/mm of DC field was applied at 25 °C, 120 °C, and 150 °C for 10 min to align the electric dipoles in the composite. The piezoelectric charge coefficient of d33 and the piezoelectric voltage coefficient of g33 were improved by increasing the temperature of the poling process. The maximum values of d33 and g33 were 14.3 pC/N and 44.2 mV·m/N, respectively, at 150 °C. The sensor's sensitivity to the impact force was measured by a ball drop test. The sensors showed a linear behavior in the output voltage with increasing impact force. The sensitivity of the sensor on the alumina and mylar substrates was 1.368 V/N and 0.815 V/N, respectively. The rising time of the sensor to the finger touch was 43 ms on the alumina substrate and 35 ms on the mylar substrate. Consequently, the high sensitivity and fast response time of the sensor make the 0-3 PZT-PVB composite a good candidate for tactile sensors.

13.
J Hepatol ; 76(2): 294-301, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34563579

RESUMO

BACKGROUND & AIMS: Guidelines recommend hepatocellular carcinoma (HCC) surveillance in patients with chronic HBV infection. Several HCC risk prediction models are available to guide surveillance decisions, but their comparative performance remains unclear. METHODS: Using a retrospective cohort of patients with HBV treated with nucleos(t)ide analogues at 130 Veterans Administration facilities between 9/1/2008 and 12/31/2018, we calculated risk scores from 10 HCC risk prediction models (REACH-B, PAGE-B, m-PAGE-B, CU-HCC, HCC-RESCUE, CAMD, APA-B, REAL-B, AASL-HCC, RWS-HCC). We estimated the models' discrimination and calibration. We calculated HCC incidence in risk categories defined by the reported cut-offs for all models. RESULTS: Of 3,101 patients with HBV (32.2% with cirrhosis), 47.0% were treated with entecavir, 40.6% tenofovir, and 12.4% received both. During a median follow-up of 4.5 years, 113 patients developed HCC at an incidence of 0.75/100 person-years. AUC values for 3-year HCC risk were the highest for RWS-HCC, APA-B, REAL-B, and AASL-HCC (all >0.80). Of these, 3 (APA-B, RWS-HCC, REAL-B) incorporated alpha-fetoprotein. AUC values for the other models ranged from 0.73 for PAGE-B to 0.79 for CAMD and HCC-RESCUE. Of the 7 models with AUC >0.75, only APA-B was poorly calibrated. In total, 10-20% of the cohort was deemed low-risk based on the published cut-offs. None of the patients in the low-risk groups defined by PAGE-B, m-PAGE-B, AASL-HCC, and REAL-B developed HCC during the study timeframe. CONCLUSION: In this national cohort of US-based patients with HBV on antiviral treatment, most models performed well in predicting HCC risk. A low-risk group, in which no cases of HCC occurred within a 3-year timeframe, was identified by several models (PAGE-B, m-PAGE-B, CAMD, AASL-HCC, REAL-B). Further studies are warranted to examine whether these patients could be excluded from HCC surveillance. LAY SUMMARY: Risk prediction models for hepatocellular carcinoma (HCC) in patients infected with hepatitis B virus (HBV) could guide HCC surveillance decisions. In this large cohort of US-based patients receiving treatment for HBV, most published models discriminated between those who did or did not develop HCC, although the RWS-HCC, REAL-B, and AASL-HCC performed the best. If confirmed in future studies, these models could help identify a low-risk subset of patients on antiviral treatment who could be excluded from HCC surveillance.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Hepatite B/complicações , Medição de Risco/normas , Adulto , Idoso , Área Sob a Curva , Carcinoma Hepatocelular/etiologia , Carcinoma Hepatocelular/fisiopatologia , Estudos de Coortes , Feminino , Hepatite B/fisiopatologia , Humanos , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/etiologia , Neoplasias Hepáticas/fisiopatologia , Masculino , Pessoa de Meia-Idade , Vigilância da População/métodos , Curva ROC , Estudos Retrospectivos , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Estados Unidos , United States Department of Veterans Affairs/organização & administração , United States Department of Veterans Affairs/estatística & dados numéricos
14.
Clin Gastroenterol Hepatol ; 20(12): 2848-2857.e2, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35240331

RESUMO

BACKGROUND & AIMS: Surveillance colonoscopy is recommended to reduce colorectal cancer (CRC)-related morbidity and mortality in patients with inflammatory bowel disease (IBD). The comparative effectiveness of varying colonoscopy intervals on CRC outcomes among patients with IBD is unknown. METHODS: We performed a retrospective cohort study of patients with confirmed CRC within a cohort of 77,824 patients with IBD during 2000 to 2015 in the National Veterans Health Administration. We examined the association between colonoscopy surveillance intervals on CRC stage, treatment, or all-cause and cancer-specific mortality. The interval of colonoscopy prior to CRC diagnosis was categorized as those performed within <1 year, 1 to 3 years, 3 to 5 years, or none within 5 years. RESULTS: Among 566 patients with CRC-IBD, most (69.4%) did not have colonoscopy within 5 years prior to CRC diagnosis, whereas 9.7% had colonoscopy within 1 year prior to diagnosis, 17.7% within 1 to 3 years, and 3.1% between 3 and 5 years. Compared with no surveillance, colonoscopy within 1 year (adjusted odds ratio, 0.40; 95% confidence interval [CI], 0.20-0.82), and 1 to 3 years (adjusted odds ratio, 0.56; 95% CI, 0.32-0.98) were less likely to be diagnosed at late stage. Regardless of IBD type and duration, colonoscopy within 1 year was associated with a lower all-cause mortality (adjusted hazard ratio, 0.56; 95% CI, 0.36-0.88). CONCLUSIONS: In a national cohort of patients with CRC-IBD, colonoscopy within 3 years prior to CRC diagnosis was associated with early tumor stage at diagnosis, and colonoscopy within 1 year was associated with a reduced all-cause mortality compared with no colonoscopy. Our findings support colonoscopy intervals of 1 to 3 years in patients with IBD to reduce late-stage CRC and all-cause mortality.


Assuntos
Neoplasias Colorretais , Doenças Inflamatórias Intestinais , Humanos , Estudos Retrospectivos , Neoplasias Colorretais/epidemiologia , Colonoscopia/efeitos adversos , Doenças Inflamatórias Intestinais/complicações , Doenças Inflamatórias Intestinais/diagnóstico , Doenças Inflamatórias Intestinais/patologia , Estadiamento de Neoplasias , Fatores de Risco
15.
Clin Gastroenterol Hepatol ; 20(1): 183-193, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-32927050

RESUMO

BACKGROUND & AIMS: Hepatocellular carcinoma (HCC) surveillance rates are suboptimal in clinical practice. We aimed to elicit providers' opinions on the following aspects of HCC surveillance: preferred strategies, barriers and facilitators, and the impact of a patient's HCC risk on the choice of surveillance modality. METHODS: We conducted a web-based survey among gastroenterology and hepatology providers (40% faculty physicians, 21% advanced practice providers, 39% fellow-trainees) from 26 US medical centers in 17 states. RESULTS: Of 654 eligible providers, 305 (47%) completed the survey. Nearly all (98.4%) of the providers endorsed semi-annual HCC surveillance in patients with cirrhosis, with 84.2% recommending ultrasound ± alpha fetoprotein (AFP) and 15.4% recommending computed tomography (CT) or magnetic resonance imaging (MRI). Barriers to surveillance included limited HCC treatment options, screening test effectiveness to reduce mortality, access to transportation, and high out-of-pocket costs. Facilitators of surveillance included professional society guidelines. Most providers (72.1%) would perform surveillance even if HCC risk was low (≤0.5% per year), while 98.7% would perform surveillance if HCC risk was ≥1% per year. As a patient's HCC risk increased from 1% to 3% to 5% per year, providers reported they would be less likely to order ultrasound ± AFP (83.6% to 68.9% to 57.4%; P < .001) and more likely to order CT or MRI ± AFP (3.9% to 26.2% to 36.1%; P < .001). CONCLUSIONS: Providers recommend HCC surveillance even when HCC risk is much lower than the threshold suggested by professional societies. Many appear receptive to risk-based HCC surveillance strategies that depend on patients' estimated HCC risk, instead of our current "one-size-fits all" strategy.


Assuntos
Carcinoma Hepatocelular , Detecção Precoce de Câncer , Cirrose Hepática , Neoplasias Hepáticas , Atitude do Pessoal de Saúde , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/epidemiologia , Testes Diagnósticos de Rotina , Humanos , Cirrose Hepática/complicações , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/epidemiologia , Ultrassonografia , Estados Unidos , alfa-Fetoproteínas
16.
Biochem Biophys Res Commun ; 622: 50-56, 2022 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-35843094

RESUMO

The non-POU domain-containing octamer-binding protein (NONO, also referred to as p54nrb) is a multifunctional nuclear protein engaging in transcriptional regulation, mRNA splicing, nuclear retention of defective RNA, and DNA repair. Emerging evidence has demonstrated that p54nrb is subjected to various posttranslational modifications, including phosphorylation and methylation, which may be important regulators of its multifunction. However, among these modifications, direct evidence of p54nrb acetylation and its underlying mechanism remains unclear. In this study, we reported that lysine 371 of p54nrb was reversibly acetylated by the acetyltransferase general control non-depressible 5 (GCN5) and deacetylase sirtuin 1 (SIRT1), which was crucial for activity of p54nrb to inhibit interleukin-8 (IL-8) expression. Mechanistically, GCN5-mediated acetylation attenuates the recruitment of p54nrb on its core binding motif within the IL-8 gene promoter, preferentially increasing the expression of the IL-8 gene. In contrast, deacetylation by SIRT1 reverses this process. Altogether, our data suggest that reversible acetylation is an important switch for the multiple nuclear functions of p54nrb/NONO.


Assuntos
Proteínas Associadas à Matriz Nuclear , Fatores de Transcrição de Octâmero , Acetilação , Proteínas de Ligação a DNA/metabolismo , Interleucina-8/genética , Interleucina-8/metabolismo , Proteínas Associadas à Matriz Nuclear/genética , Proteínas Associadas à Matriz Nuclear/metabolismo , Fatores de Transcrição de Octâmero/genética , Fatores de Transcrição de Octâmero/metabolismo , Processamento de Proteína Pós-Traducional , Proteínas de Ligação a RNA/metabolismo , Sirtuína 1/genética , Sirtuína 1/metabolismo , Fatores de Transcrição/metabolismo
17.
Small ; 18(14): e2107284, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35199455

RESUMO

Metal organic frameworks (MOFs), which constitute a new class of porous organic-inorganic hybrid materials, have gained considerable attention in the fields of electrochemical energy storage and conversion devices owing to their open topological structures, large surface areas, tunable morphologies, and extreme redox activity. A synthesis protocol that comprises coprecipitation followed by controlled calcination processes to design a battery-type electrode is used. This electrode consists of three-dimensional (3D), ant cave-like polyhedrons of nickel-cobalt alloy on graphitic carbon (GC; NiCo@GC) nanostructures; trimesic acid is used as a potential MOF-linker. The developed NiCo@GC sample exhibits mesoporous characteristics with the maximum surface area of 94.08 m2 g-1 at 77 K. In addition, the redox activity at different sweep rates reveals the battery-type charge storage behavior of the NiCo@GC electrode; its three-electrode assembly provides 444 C g-1 specific capacity at 2 A g-1 with long-term capacity retention. The constructed supercapattery (SC) devices (i.e., AC//NiCo@GC) achieved capacity, specific energy, and specific power are 74.3 mAh g-1 , 39.5 Wh kg-1 , and 665 W kg-1 , respectively. Owing to its reasonable electrochemical characteristics, the prepared NiCo@GC material is a promising candidate for supercapattery electrodes for portable electronic devices.


Assuntos
Estruturas Metalorgânicas , Eletroquímica , Eletrodos , Níquel , Oxirredução
18.
Small ; 18(13): e2104216, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35146911

RESUMO

The interface architectures of inorganic-organic halide perovskite-based devices play key roles in achieving high performances with these devices. Indeed, the perovskite layer is essential for synergistic interactions with the other practical modules of these devices, such as the hole-/electron-transfer layers. In this work, a heterostructure geometry comprising transition-metal dichalcogenides (TMDs) of molybdenum dichalcogenides (MoX2  = MoS2 , MoSe2 , and MoTe2 ) and perovskite- or hole-transfer layers is prepared to achieve improved device characteristics of perovskite solar cells (PSCs), X-ray detectors, and photodetectors. A superior efficiency of 11.36% is realized for the active layer with MoTe2 in the PSC device. Moreover, X-ray detectors using modulated MoTe2 nanostructures in the active layers achieve 296 nA cm-2 , 3.12 mA (Gy cm2 )-1 and 3.32 × 10-4 cm2 V-1 s-1 of collected current density, sensitivity, and mobility, respectively. The fabricated photodetector produces a high photoresponsivity of 956 mA W-1 for a visible light source, with an excellent external quantum efficiency of 160% for the perovskite layer containing MoSe2 nanostructures. Density functional theory calculations are made for pure and MoX2 doped perovskites' geometrical, density of states and optical properties variations evidently. Thus, the present study paves the way for using perovskite-based devices modified by TMDs to develop highly efficient semiconductor devices.

19.
Phys Chem Chem Phys ; 24(47): 28923-28933, 2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36416292

RESUMO

Green synthesis of copper oxide nanoparticles and its effects on photocatalytic dye degradation and antibacterial activities are reported. The synthesis of nanoparticles by green routes provides many advantages over chemical routes, including simplicity, cost-effectiveness, and fast processing route without using any costly or harmful chemicals. Tridax procumbense (coat buttons) plant root extract was used to synthesize copper oxide nanoparticles. The synthesized Tridax procumbense-copper oxide nanoparticles (TP-CuO NPs) were characterized by UV-visible spectroscopy, Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM), transmission electron microscopy (TEM), dynamic light scattering spectroscopy (DLS), and X-ray diffraction (XRD) techniques. The synthesized TP-CuO NPs were applied for photocatalytic dye degradation and antibacterial activity studies. The TP-CuO NPs exhibited a maximum antibacterial activity at 500 µg mL-1 concentration against Staphylococcus aureus and E. coli showing inhibition zones of 7.5 mm and 7.2 mm, respectively. The photocatalytic ability of the TP-CuO was also tested against the textile dye Trypan blue (TB), and showed about 55% degradation after 48 h for 500 µg mL-1 CuO NP concentration, showing a concentration-dependent degradation efficiency. This is the first work on TP-derived CuO nanoparticles and their photocatalytic and antimicrobial applications. Overall, this study supports the superiority of green-synthesized TP-CuO NPs as photocatalytic and antimicrobial agents.


Assuntos
Cobre , Escherichia coli , Óxidos
20.
Sensors (Basel) ; 22(2)2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35062593

RESUMO

Research on stretchable strain sensors is actively conducted due to increasing interest in wearable devices. However, typical studies have focused on improving the elasticity of the electrode. Therefore, methods of directly connecting wire or attaching conductive tape to materials to detect deformation have been used to evaluate the performance of strain sensors. Polyaniline (PANI), a p-type semiconductive polymer, has been widely used for stretchable electrodes. However, conventional procedures have limitations in determining an appropriate metal for ohmic contact with PANI. Materials that are generally used for connection with PANI form an undesirable metal-semiconductor junction and have significant contact resistance. Hence, they degrade sensor performance. This study secured ohmic contact by adapting Au thin film as the metal contact layer (the MCL), with lower contact resistance and a larger work function than PANI. Additionally, we presented a buffer layer using hard polydimethylsiloxane (PDMS) and structured it into a dumbbell shape to protect the metal from deformation. As a result, we enhanced steadiness and repeatability up to 50% strain by comparing the gauge factors and the relative resistance changes. Consequently, adapting structural methods (the MCL and the dumbbell shape) to a device can result in strain sensors with promising stability, as well as high stretchability.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA