Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Catheter Cardiovasc Interv ; 103(4): 618-625, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38436540

RESUMO

BACKGROUND: Mitral annular calcification (MAC) has been an exclusion for many of the earlier pivotal trials that were instrumental in gaining device approval and indications for mitral transcatheter edge-to-edge repair (M-TEER). AIMS: To evaluate the impact of MAC on the procedural durability and success of newer generation MitraClip® systems (G3 and G4 systems). METHODS: Data were collected from Northwell TEER registry. Patients that underwent M-TEER with third or fourth generation MitraClip device were included. Patients were divided into -MAC (none-mild) and +MAC (moderate-severe) groups. Procedural success was defined as ≤ grade 2 + mitral regurgitation (MR) postprocedure, and durability was defined as ≤ grade 2 + MR retention at 1 month and 1 year. Univariate analysis compared outcomes between groups. RESULTS: Of 260 M-TEER patients, 160 were -MAC and 100 were +MAC. Procedural success was comparable; however, there were three patients who required conversion to cardiac surgery during the index hospitalization in the +MAC group versus none in the -MAC group (though this was not statistically significant). At 1-month follow-up, there were no significant differences in MR severity. At 1-year follow-up, +MAC had higher moderate-severe MR (22.1% vs. 7.5%; p = 0.002) and higher mean transmitral gradients (5.3 vs. 4.0 mmHg; p = 0.001) with no differences in mortality, New York Heart Association functional class or ejection fraction. CONCLUSION: In selective patients with high burden of MAC, contemporary M-TEER is safe, and procedural success is similar to patients with none-mild MAC. However, a loss of procedural durability was seen in +MAC group at 1-year follow-up. Further studies with longer follow-ups are required to assess newer mTEER devices and their potential clinical implications in patients with a high burden of MAC.


Assuntos
Insuficiência da Valva Mitral , Humanos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Hospitalização , Sistema de Registros , Tecnologia
2.
Catheter Cardiovasc Interv ; 100(3): 415-421, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36453245

RESUMO

BACKGROUND: For patients with borderline annulus areas that fall between two valve sizes, overinflating a smaller balloon-expandable transcatheter heart valve (THV) may be preferable to nominal sizing of a larger THV. OBJECTIVES: To evaluate the outcomes of nominal preparation versus over-expanding an under-sized SAPIEN 3 Ultra (S3U) transcatheter heart valve (OE-THV) in cases with borderline annuli. METHODS: 958 patients that underwent TAVR with the S3U at four high-volume TAVR centers between January 2017 and December 2020 were retrospectively reviewed. 336 patients were identified as borderline annuli size, of which 146 (44%) received OE-THVs and 190 (56%) received nominal-sized THVs. The primary composite endpoint included: in-hospital mortality, aortic injury, moderate/severe paravalvular leak (PVL), permanent pacemaker implant (PPM), stroke, or conversion to surgery. RESULTS: Baseline characteristics were similar except for a larger percentage of females in the OE-THV (53.42% vs. 42.11%, p = 0.04). TAVR with OE-THV resulted a reduction in the primary composite endpoint (13.69% vs. 22.63%, p = 0.04). On subgroup analysis, there was no difference between 20 mm OE-THV versus 23 mm nominal or 23 mm OE-THV versus 26 mm nominal, but there was a reduction in the primary composite endpoint in patients with larger annuli that received a 26 mm OE-THV compared to the 29 mm nominally sized THV (9.7% vs. 27.4%, p = 0.02). At 1 month and 1 year follow-up, there was no significant difference in mortality, PVL rates, NYHA class, and/or KCCQ score. CONCLUSION: Overinflating a smaller-sized S3U THV may be a safer option in comparison to nominal sizing in patients with borderline annular area.


Assuntos
Catéteres , Valvas Cardíacas , Feminino , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Mortalidade Hospitalar
3.
J Card Surg ; 37(12): 4937-4943, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378870

RESUMO

OBJECTIVE: The aim of this study was to compare outcomes of transcatheter heart valve (THV) choice in patients with left ventricular (LV) systolic dysfunction. BACKGROUND: The management congestive heart failure with combined LV systolic dysfunction and severe aortic stenosis (AS) is challenging, yet transcatheter aortic valve replacement (TAVR) has emerged as a suitable treatment option in such patients. Head-to-head comparisons among the balloon-expandable (BEV) and self-expandable (SEV) THV remain limited in this subgroup of patients. METHODS: In this retrospective study, we included patients with severe AS with LV systolic dysfunction (LVEF ≤40%) who underwent TAVR at four high volume centers. Two thousand and twenty-eight consecutive patients were analyzed, of which 335 patients met inclusion criteria. One hundred fourty-six patients (43%) received a SEV, and 189 patients (57%) received a BEV. RESULTS: Baseline characteristics were similar except for a higher proportion of females in the SEV group. The primary composite endpoint of in-hospital mortality, moderate or greater paravalvular (PVL), stroke, conversion to open surgery, aortic valve reintervention, and/or need for permanent pacemaker (PPM) was no different among THV choice. There was more PVL in the SEV group, but higher transaortic gradients in the BEV group. Clinical outcomes and quality of life measures were similar up to 1 year follow-up. CONCLUSION: The choice of THV in patients with severe AS and systolic dysfunction must be weighed on a case-by-case basis.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Feminino , Humanos , Estudos Retrospectivos , Volume Sistólico , Qualidade de Vida , Fatores de Risco , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Disfunção Ventricular Esquerda/etiologia , Resultado do Tratamento , Desenho de Prótese
6.
Int J Angiol ; 33(2): 101-106, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38846990

RESUMO

Pulmonary embolism (PE) is a common disease associated with significant morbidity and mortality. Despite the familiarity with this disease, the best treatment remains undefined. Traditionally, treatment of PE has involved a choice of anticoagulation, thrombolysis, or surgery. However, the debate over pharmacologic versus mechanical treatment of acute PE reared up again with the advent of user-friendly mechanical and aspiration thrombectomy technologies. This is especially true for submassive PE, which is an area for potential growth both for understanding the pathophysiology of the disease process and management. Multiple devices are available for treatment of PE. Understanding the risks and benefits of each device is paramount in the complex management of PE.

7.
J Invasive Cardiol ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38718283

RESUMO

A 79-year-old man with a failed 25-mm CE Magna Ease 3300 surgical prosthesis (Edwards Lifesciences) and of high re-operative surgical risk (STS 8%) presented with dyspnea, NYHA III. Cardiac computed tomography angiography revealed anatomy that was high risk for coronary occlusion with a short right coronary artery height of 6 mm and a valve-to-coronary distance of 2 mm.

8.
J Cardiol Cases ; 28(4): 141-143, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37818437

RESUMO

In patients with ostial coronary stents protruding into the aorta, there is concern for stent injury while undergoing transcatheter aortic valve replacement (TAVR) with balloon-expandable transcatheter heart valve (THV). An 82-year-old male with history of symptomatic aortic stenosis, heart failure, and coronary artery disease with multiple interventions to right coronary artery (RCA) and a history of stent fracture requiring stent-in-stent placement one year previously, was evaluated for TAVR. His ostial RCA stent was protruding into the aorta at the level of sinotubular junction, with ostial stent to aortic wall (SAW) distance of 25.2 mm. There was concern for balloon inflation during TAVR leading to stent injury. The RCA was cannulated with a 6 French JR4 guide and wired with 0.014' coronary wire. Appropriately sized noncompliant balloon was advanced into RCA. Under rapid pacing, the coronary balloon was inflated across the RCA ostium followed by simultaneous deployment of THV. Intravascular imaging of the ostial RCA stent revealed no stent fracture. SAW distance is important to determine the possibility of balloon-induced stent injury during valve deployment. In cases where an ostial stent may interact with balloon inflation, kissing-balloon inflation may be performed to prevent stent injury. Learning objective: In patients with ostial coronary stents protruding into the aorta, stent to aortic wall distance is important to determine the possibility of balloon-induced stent injury during balloon-expandable transcatheter heart valve deployment. Kissing-balloon inflation may be performed to prevent stent injury.

9.
J Clin Med ; 12(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36983390

RESUMO

Treatment of congestive heart failure (CHF) with left ventricular (LV) systolic dysfunction and severe aortic stenosis (AS) is challenging, yet transcatheter aortic valve replacement (TAVR) has emerged as a suitable treatment option in such patients. We compared the periprocedural outcomes of TAVR in patients with an ejection fraction (EF) of ≤20% (VLEF group) to patients with an EF > 20% to ≤40% (LEF group). We included patients with severe AS and reduced LV ejection fraction (LVEF ≤ 40%) who underwent TAVR at four centers within Northwell Health between January 2016 and December 2020. Over 2000 consecutive patients were analyzed, of which 355 patients met the inclusion criteria. The primary composite endpoint was in-hospital mortality, moderate or greater paravalvular (PVL), stroke, conversion to open surgery, aortic valve re-intervention, and/or need for PPM. Secondary endpoints were length of stay, NYHA classification at 1 month and 1 year, mortality at 1 month and 1 year, mean valve gradient at 1 month, KCCQ score at 1 month, and ≥ moderate PVL at 1 month. There was no difference in the primary composite endpoint between the two groups (23.6% for VLEF vs. 25.3% for LEF, p = 0.29). During TAVR placement, 40% of patients in the VLEF group required ≥1 vasopressors for hypotension lasting ≥30 min vs. only 21% of patients in the LEF group (p < 0.01). Intra-aortic balloon pump (IABP) use during procedure was greater in the VLEF group (9% vs. 1%, p < 0.01)-all placed post TAVR. Emergency ECMO use was higher in the VLEF group as well (5% vs. 0%). Total length of stay was significantly different between the two groups as well (6 days vs. 3 days, p < 0.01). Both groups had a change in LVEF of ~10%. One-year outcomes were similar between the groups. All-cause mortality at 1 year was not significantly different at 1 year (13% for VLEF vs. 11% for LEF), and KCC scores were also similar (77.54 vs. 74.97). Mean aortic valve gradients were also similar (12 mmHg vs. 11 mmHg, p = 0.48). Our study suggests that patients with EF ≤ 20% can safely have TAVR with similar periprocedural outcomes compared to patients with EF > 20% to ≤40% despite higher rates of vasopressor and mechanical support.

10.
J Cardiovasc Imaging ; 31(1): 18-23, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36693340

RESUMO

BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

11.
J Invasive Cardiol ; 35(2): E92-E98, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36525541

RESUMO

BACKGROUND: The prevalence of coronary artery disease (CAD) in patients undergoing TAVR varies and is associated with increased morbidity and mortality. We evaluated the outcomes of complex and high-risk percutaneous coronary interventions (CHIP-PCIs) and TAVR compared with standard PCI and TAVR. Between January 2014 and March 2021, a total of 276 consecutive patients with severe aortic stenosis (AS) who underwent TAVR and PCI at 3 centers within Northwell Health were retrospectively reviewed. CHIP-PCI was defined as PCI with one of the following: left ventricular ejection fraction (LVEF) <30%; left main coronary artery (LMCA)/chronic total occlusion (CTO) intervention; atherectomy; or need for left ventricular (LV) support. One hundred twenty- seven patients (46%) had CHIP-PCI prior to TAVR and 149 patients (54%) had standard PCI. Thirteen percent of CHIP-PCI and 22% of standard PCI cases were done concomitantly with TAVR. CHIP-PCI criteria were met for low EF (19%), LMCA (25%), CTO (3%), LV support (20%), and atherectomy (50%). The types of valves used were similarly divided (49% balloon expandable vs 51% self expanding. Major adverse cardiac or cerebrovascular event (MACCE) rate for CHIP-PCI/TAVR was 4.9% at 30 days vs 1.3% for standard PCI/TAVR (P=.09), driven by in-hospital stroke. At 1 year, the rates of MACCE for CHIP-PCI/TAVR remained higher than for standard PCI/TAVR, but was not statistically significant (8.7% vs 4%; P=.06), driven by revascularization. We found no differences between major and/or minor vascular complications. New York Heart Association classification at 1 month was similar (I/II 93% vs 95%; P=.87). Our study suggests that CHIP-PCI can be safely performed in patients with complex CAD and concomitant severe AS.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Fatores de Risco
12.
Front Cardiovasc Med ; 10: 1206570, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38028504

RESUMO

Background: Expert opinion and professional society statements have called for multi-tier care systems for the management of cardiogenic shock (CS). However, little is known about how to pragmatically define centers with different levels of care (LOC) for CS. Methods: Eleven of 23 hospitals within our healthcare system sharing a common electronic health record were classified as different LOC according to their highest mechanical circulatory support (MCS) capabilities: Level 1 (L-1)-durable left ventricular assist device, Level 1A (L-1A)-extracorporeal membrane oxygenation, Level 2 (L-2)-intra-aortic balloon pump and percutaneous ventricular assist device; and Level 3 (L-3)-no MCS. All adult patients treated for CS (International Classification of Diseases, ICD-10 code R57.0) between 2016 and 2022 were included. Etiologies of CS were identified using associated diagnostic codes. Management strategies and outcomes across LOC were compared. Results: Higher LOC centers had higher volumes: L-1 (n = 1): 2,831 patients, L-1A (n = 4): 3,452, L-2 (n = 1): 340, and L-3 (n = 5): 780. Emergency room admissions were more common in lower LOC (96% at L-3 vs. 46% L-1; p < 0.001), while hospital transfers were predominant at higher LOC (40% at L-1 vs. 2.7% at L-3; p < 0.001). Men comprised 61% of the cohort. Patients were younger in the higher LOC [69 (60-78) years at L-1 vs. 77 (67-85) years at L-3; p < 0.001]. Patients with acute myocardial infarction (AMI)-CS and acute heart failure (AHF)-CS were concentrated in higher LOC centers while other etiologies of CS were more common in L-2 and L-3 (p < 0.001). Cardiac arrest on admission was more prevalent in lower LOC centers (L-1: 2.8% vs. L-3: 12.1%; p < 0.001). Patients with AMI-CS received more percutaneous coronary intervention in lower LOC (51% L-2 vs. 29% L-1; p < 0.01) but more coronary arterial bypass graft surgery at higher LOC (L-1: 42% vs. L-1A: 23%; p < 0.001). MCS use was consistent across levels for AMI-CS but was more frequent in higher LOC for AHF-CS patients (L-1: 28% vs. L-2: 10%; p < 0.001). Despite increasing in-hospital mortality with decreasing LOC, no significant difference was seen after multivariable adjustment. Conclusion: This is the first report describing a pragmatic classification of LOC for CS which, based on MCS capabilities, can discriminate between centers with distinct demographics, practice patterns, and outcomes. This classification may serve as the basis for future research and the creation of CS systems of care.

13.
Int J Angiol ; 31(4): 229-231, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36588870

RESUMO

Aortic stenosis is the most common valvular heart disease affecting the elderly. While most patients have a prolonged asymptomatic phase, the development of symptoms ushers in a phase clinical deterioration that often leads to sudden death without an intervention. Treatment of aortic stenosis with valve replacement often relieves the symptoms but still leaves behind a remodeled left ventricle which may not recover. Understanding the pathophysiology of aortic stenosis and realizing that the disease process may be a more active biological entity rather than a passive degenerative process will help us prevent it. This review serves to summarize the latest literature on the pathophysiology of aortic stenosis in the elderly.

14.
Int J Angiol ; 31(3): 150-154, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36157099

RESUMO

Pulmonary embolism (PE) is quite common and is associated with significant morbidity and mortality. It is estimated that it is the cause of approximately 100,000 annual deaths in the United States. With great variability in presenting symptoms of PE, poor recognition of PE can be fatal. As such, many risk scores have been created to identify the sickest patients. Choosing the appropriate imaging modality is also critical. Invasive pulmonary angiography was once the gold standard to establish the diagnosis. With the advent of nuclear imaging, V/Q scans, invasive angiography has been phased out for diagnosing acute PE. At present, the standard for diagnosis of acute PE is computed tomography pulmonary angiography. In select patient cohorts, nuclear studies remain the modality of choice. Once the diagnosis of acute PE is established, there is a broad spectrum of severity in outcome which has led to substantial focus and development of risk stratification prediction models. We will discuss making the proper diagnosis with contemporary diagnostic tools and risk stratifying patients with PE to receive the correct treatment.

15.
Struct Heart ; 6(2): 100021, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37273736

RESUMO

Background: Percutaneous transradial placement of the Sentinel cerebral embolic protection device (CEPD) (Boston Scientific) is indicated during transcatheter aortic valve replacement to capture embolic material in patients without excessive tortuosity of the right subclavian/innominate arteries. We aimed to generate a quantitative tortuosity index (TI) from the preoperative computed tomographic angiography (CTA) as an objective measure of tortuosity to determine suitability for CEPD placement. Methods: Eighty-one patients considered for CEPD were included in this study. A centerline of the right subclavian/innominate arteries was generated from preoperative CTA scans. Three-dimensional Cartesian coordinates of landmarks along the centerline were used to calculate curvature. Tortuosity was derived as a change in angulation along each vessel segment. Peak and average TI values were calculated. Results: Sixty-seven patients had CEPD placement attempted. Unsuccessful CEPD placement occurred in 3 of 67 (4.4%) patients. The peak tortuosity for the successful, unsuccessful, and visually tortuous (not attempted) cohorts were 49.66 ± 11.96°/cm, 113.92 ± 5.70°/cm, and 70.44 ± 17.01°/cm, respectively. The peak and average TI of the successful cohort follows a normal distribution. A proposed TI cutoff for safe CEPD was peak tortuosity of 74°/cm and average tortuosity of 30°/cm, 2 standard deviations above the peak and average TI of the successful cohort. All unsuccessful CEPD patients fell outside the boundaries. Half of the visually tortuous patients were within the boundaries but did not have CEPD attempted. Conclusions: A novel TI based on preoperative CTA can assist in selecting patients for transradial CEPD. Our proposed quantitative tool may help to appropriately include and exclude patients for CEPD placement.

16.
Innovations (Phila) ; 15(5): 478-480, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32758050

RESUMO

A patent foramen ovale (PFO) is well known to cause paradoxical embolism and stroke, but a less appreciated and life-threatening complication can occur when combined with severe pulmonary embolism (PE). Acutely elevated right-sided pressures from right ventricular strain due to PE can lead to right-to-left (R-L) shunting through the PFO and exacerbate hypoxia. We report a case of a 50-year-old female patient with massive PE with further desaturation from R-L shunting from a PFO that benefitted from percutaneous closure of the interartrial communication. Our patient recovered without any complications and had excellent long-term follow-up.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Forame Oval Patente/cirurgia , Hipóxia/etiologia , Embolia Pulmonar/complicações , Angiografia , Ecocardiografia , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico , Humanos , Hipóxia/diagnóstico , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/cirurgia , Índice de Gravidade de Doença
17.
Metabol Open ; 7: 100050, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32924001

RESUMO

BACKGROUND: The association between coronary artery disease (CAD) and diabetes mellitus (DM) is strong but the physiologic mechanisms responsible for this association remain unclear. Patients with DM exhibit high circulating levels of glycated proteins and lipoproteins called advanced glycation end products (AGEs) which have been implicated in the development of oxidative damage to vascular endothelium. We examined the relationships between the presence and extent of CAD and AGEs in patients undergoing elective coronary artery catheterization in an urban teaching hospital. METHODS: Patients with possible CAD (n = 364) were recruited prior to elective cardiac catheterization (52% male, 48% diabetic). Regression and correlation analyses were used to examine the relationship between serum AGE concentrations, soluble AGE receptor (sRAGE) concentration, HbA1c, LDL and the presence of obstructive CAD along with the burden of CAD measured by SYNTAX and SYNTAX II scores. RESULTS: AGE and sRAGE levels did not significantly correlate with any of the studied coronary artery disease parameters. HbA1c showed positive correlation with both SYNTAX and SYNTAX II scores in patients with and without diabetes. CONCLUSION: In this cross-sectional study of patients with possible CAD, serum AGEs and sRAGE concentrations did not correlate with SYNTAX or SYNTAX II scores regardless of diabetic status. HbA1C correlated positively with the SYNTAX and SYNTAX II scores in both diabetic and non-diabetic populations.

18.
J Surg Res ; 153(2): 347-58, 2009 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-19027922

RESUMO

BACKGROUND: A chronic wound is tissue with an impaired ability to heal. This is often a consequence of one of the following etiologies: diabetes, venous reflux, arterial insufficiency sickle cell disease, steroids, and/or pressure. Healing requires granulation tissue depending on epithelialization and angiogenesis. Currently no growth factor is available to treat patients with impaired healing that stimulates both epithelialization and angiogenesis. The objective is to review is the multiple mechanisms of vascular endothelial growth factor (VEGF) in wound healing. MATERIALS AND METHODS: The authors reviewed the literature on the structure and function of VEGF, including its use for therapeutic angiogenesis. Particular attention is given to the specific role of VEGF in the angiogenesis cascade, its relationship to other growth factors and cells in a healing wound. RESULTS: VEGF is released by a variety of cells and stimulates multiple components of the angiogenic cascade. It is up-regulated during the early days of healing, when capillary growth is maximal. Studies have shown the efficacy of VEGF in peripheral and cardiac ischemic vascular disease with minimal adverse effects. Experimental data supports the hypothesis that VEGF stimulates epithelialization and collagen deposition in a wound. CONCLUSION: VEGF stimulates wound healing through angiogenesis, but likely promotes collagen deposition and epithelialization as well. Further study of the molecule by utilizing the protein itself, or novel forms of delivery such as gene therapy, will increase its therapeutic possibilities to accelerate closure of a chronic wound.


Assuntos
Neovascularização Fisiológica , Fator A de Crescimento do Endotélio Vascular/fisiologia , Cicatrização , Animais , Humanos , Receptores de Fatores de Crescimento do Endotélio Vascular/metabolismo , Fator A de Crescimento do Endotélio Vascular/química , Fator A de Crescimento do Endotélio Vascular/uso terapêutico
19.
J Transl Med ; 6: 75, 2008 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-19046453

RESUMO

BACKGROUND: Multiple physiologic impairments are responsible for chronic wounds. A cell line grown which retains its phenotype from patient wounds would provide means of testing new therapies. Clinical information on patients from whom cells were grown can provide insights into mechanisms of specific disease such as diabetes or biological processes such as aging. The objective of this study was 1) To culture human cells derived from patients with chronic wounds and to test the effects of putative therapies, Granulocyte-Macrophage Colony Stimulating Factor (GM-CSF) on these cells. 2) To describe a methodology to create fibroblast cell lines from patients with chronic wounds. METHODS: Patient biopsies were obtained from 3 distinct locations on venous ulcers. Fibroblasts derived from different wound locations were tested for their migration capacities without stimulators and in response to GM-CSF. Another portion of the patient biopsy was used to develop primary fibroblast cultures after rigorous passage and antimicrobial testing. RESULTS: Fibroblasts from the non-healing edge had almost no migration capacity, wound base fibroblasts were intermediate, and fibroblasts derived from the healing edge had a capacity to migrate similar to healthy, normal, primary dermal fibroblasts. Non-healing edge fibroblasts did not respond to GM-CSF. Six fibroblast cell lines are currently available at the National Institute on Aging (NIA) Cell Repository. CONCLUSION: We conclude that primary cells from chronic ulcers can be established in culture and that they maintain their in vivo phenotype. These cells can be utilized for evaluating the effects of wound healing stimulators in vitro.


Assuntos
Técnicas de Cultura de Células/métodos , Linhagem Celular , Fibroblastos , Fator Estimulador de Colônias de Granulócitos e Macrófagos/farmacologia , Cicatrização/efeitos dos fármacos , Movimento Celular/fisiologia , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/fisiologia , Fator Estimulador de Colônias de Granulócitos e Macrófagos/genética , Humanos , Fenótipo , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo , Úlcera Varicosa/patologia , Cicatrização/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA