Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 23(1): 122, 2022 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-35123466

RESUMO

BACKGROUND: To evaluate the diagnostic value of MR-derived CT-like images and simulated radiographs compared with conventional radiographs in patients with suspected shoulder pathology. METHODS: 3 T MRI of the shoulder including a 3D T1-weighted gradient echo sequence was performed in 25 patients (mean age 52.4 ± 18 years, 13 women) with suspected shoulder pathology. Subsequently a cone-beam forward projection algorithm was used to obtain intensity-inverted CT-like images and simulated radiographs. Two radiologists evaluated the simulated images separately and independently using the conventional radiographs as the standard of reference, including measurements of the image quality, acromiohumeral distance, critical shoulder angle, degenerative joint changes and the acromial type. Additionally, the CT-like MR images were evaluated for glenoid defects, subcortical cysts and calcifications. Agreement between the MR-derived simulated radiographs and conventional radiographs was calculated using Cohen's Kappa. RESULTS: Measurements on simulated radiographs and conventional radiographs overall showed a substantial to almost perfect inter- and intra-rater agreement (κ = 0.69-1.00 and κ = 0.65-0.85, respectively). Image quality of the simulated radiographs was rated good to excellent (1.6 ± 0.7 and 1.8 ± 0.6, respectively) by the radiologists. A substantial agreement was found regarding diagnostically relevant features, assessed on Y- and anteroposterior projections (κ = 0.84 and κ = 0.69 for the measurement of the CSA; κ = 0.95 and κ = 0.60 for the measurement of the AHD; κ = 0.77 and κ = 0.77 for grading of the Samilson-Prieto classification; κ = 0.83 and κ = 0.67 for the grading of the Bigliani classification, respectively). CONCLUSION: In this proof-of-concept study, clinically relevant features of the shoulder joint were assessed reliably using MR-derived CT-like images and simulated radiographs with an image quality equivalent to conventional radiographs. MR-derived CT-like images and simulated radiographs may provide useful diagnostic information while reducing the amount of radiation exposure.


Assuntos
Imageamento por Ressonância Magnética , Dor de Ombro , Acrômio , Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Dor de Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X
2.
Eur Radiol ; 29(7): 3606-3616, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30903337

RESUMO

PURPOSE: To systematically evaluate the effects of virtual tube current reduction and sparse sampling on image quality and vertebral fracture diagnostics in multi-detector computed tomography (MDCT). MATERIALS AND METHODS: In routine MDCT scans of 35 patients (80.0% females, 70.6 ± 14.2 years, 65.7% showing vertebral fractures), reduced radiation doses were retrospectively simulated by virtually lowering tube currents and applying sparse sampling, considering 50%, 25%, and 10% of the original tube current and projections, respectively. Two readers evaluated items of image quality and presence of vertebral fractures. Readout between the evaluations in the original images and those with virtually lowered tube currents or sparse sampling were compared. RESULTS: A significant difference was revealed between the evaluations of image quality between MDCT with virtually lowered tube current and sparse-sampled MDCT (p < 0.001). Sparse-sampled data with only 25% of original projections still showed good to very good overall image quality and contrast of vertebrae as well as minimal artifacts. There were no missed fractures in sparse-sampled MDCT with 50% reduction of projections, and clinically acceptable determination of fracture age was possible in MDCT with 75% reduction of projections, in contrast to MDCT with 50% or 75% virtual tube current reduction, respectively. CONCLUSION: Sparse-sampled MDCT provides adequate image quality and diagnostic accuracy for vertebral fracture detection with 50% of original projections in contrast to corresponding MDCT with lowered tube current. Thus, sparse sampling is a promising technique for dose reductions in MDCT that could be introduced in future generations of scanners. KEY POINTS: • MDCT with a reduction of projection numbers of 50% still showed high diagnostic accuracy without any missed vertebral fractures. • Clinically acceptable determination of vertebral fracture age was possible in MDCT with a reduction of projection numbers of 75%. • With sparse sampling, higher reductions in radiation exposure can be achieved without compromised image or diagnostic quality in routine MDCT of the spine as compared to MDCT with reduced tube currents.


Assuntos
Artefatos , Vértebras Cervicais/lesões , Tomografia Computadorizada Multidetectores/métodos , Fraturas da Coluna Vertebral/diagnóstico , Vértebras Torácicas/lesões , Adulto , Idoso , Idoso de 80 Anos ou mais , Vértebras Cervicais/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Vértebras Torácicas/diagnóstico por imagem
3.
Eur Radiol ; 29(11): 5950-5960, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31073861

RESUMO

OBJECTIVES: Evaluation of sparse sampling computed tomography (SpSCT) regarding subjective and objective image criteria for the detection of pulmonary embolism (PE) at different simulated dose levels. METHODS: Computed tomography pulmonary angiography (CTPA) scans of 20 clinical patients were used to obtain simulated low-dose scans with 100%-50%-25%-12.5%-6.3%-3.1% of the clinical dose, resulting in a total of six dose levels (DL). From these full sampling (FS) data, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to obtain simulated sparse sampling scans. Each image set was evaluated by four blinded radiologists regarding subjective image criteria (artifacts, image quality) and diagnostic performance (confidence, sensitivity, specificity, accuracy, and area under the curve). Additionally, the contrast-to-noise ratio (CNR) was evaluated for objective image quality. RESULTS: Sensitivity was 100% with 2-SpSCT and 4-SpSCT at the 25% DL and the 12.5% DL for all localizations of PE (one subgroup 98.5%). With FS, the sensitivity decreased to 90% at the 12.5% DL. 2-SpSCT and 4-SpSCT showed higher values for sensitivity, specificity, accuracy, and the area under the curve at all DL compared with FS. Subjective image quality was significantly higher for 4-SpSCT compared with FS at each dose level (p < 0.01, paired t test). Only with 4-SpSCT, all examinations were rated as showing diagnostic image quality at the 12.5% DL. CONCLUSIONS: Via SpSCT, a dose reduction down to a 12.5% dose level (corresponding to a mean effective dose of 0.38 mSv in the current study) for CTPA is possible while maintaining high image quality and full diagnostic confidence. KEY POINTS: • With sparse sampling CT, radiation dose could be significantly reduced in clinical routine. • Sparse sampling CT is a novel hardware solution with which less projection images are acquired. • In the current study, a dose reduction of 87.5% (corresponding to a mean effective dose of 0.38 mSv) for CTPA could be achieved while maintaining excellent diagnostic performance.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Embolia Pulmonar/diagnóstico por imagem , Análise de Variância , Artefatos , Estudos de Viabilidade , Humanos , Pulmão/diagnóstico por imagem , Segurança do Paciente , Doses de Radiação , Sensibilidade e Especificidade
4.
Eur Radiol ; 29(1): 13-21, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29948069

RESUMO

OBJECTIVES: To evaluate the diagnostic value of MR-derived CT-like images and simulated radiographs compared with conventional radiographs in patients with benign and malignant bone tumors. METHODS: In 32 patients with a benign or malignant bone lesion (mean age 33.9 ± 18.5 years, 17 females), 3-T MR imaging was performed including a 3D T1-weighted gradient echo sequence as the basis for the CT-like images. From these, intensity-inverted MR image volumes were converted into 2D images via a forward projection to obtain simulated radiographs. Two radiologists assessed these images as well as conventional radiographs for the type of periosteal reaction, matrix mineralization and destruction pattern. Agreement between the modalities was calculated using Cohen's κ. RESULTS: The agreement between conventional radiographs and MR-derived CT-like images in combination with simulated radiographs was substantial (periosteal reaction, κ = 0.67; destruction pattern, κ = 0.75), and the sensitivity of both modalities for the final diagnosis of the lesion (aggressive vs. nonaggressive) was high (MR-derived CT-like images, 86.2% vs. conventional radiographs, 90.0%). Additional information on soft tissue extension (MR-derived CT-like images, 21.9% vs. conventional radiographs, 12.5%; p = 0.009) and lobulation (9.4% vs. 0%; p < 0.001) was significantly more often found on MR-derived CT-like images compared with conventional radiographs. CONCLUSIONS: The assessment of the destruction patterns, periosteal reaction and distinction between aggressive and nonaggressive tumors was feasible using MR-derived CT-like images and simulated radiographs and is comparable to that of conventional radiographs. Moreover, MR-derived CT-like images provided additional information on soft tissue extension and tumor architecture. KEY POINTS: • CT-like images and simulated radiographs can be generated from 3D MRI. • Evaluation of bone tumors is feasible with MR-derived images. • CT-like images and simulated radiographs provide additional information on bone tumors.


Assuntos
Doenças Ósseas/diagnóstico , Neoplasias Ósseas/diagnóstico , Osso e Ossos/diagnóstico por imagem , Simulação por Computador , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Curva ROC
5.
Eur Radiol ; 29(9): 4624-4634, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30758656

RESUMO

OBJECTIVES: To develop and evaluate a method for areal bone mineral density (aBMD) measurement based on dual-layer spectral CT scout scans. METHODS: A post-processing algorithm using a pair of 2D virtual mono-energetic scout images (VMSIs) was established in order to semi-automatically compute the aBMD at the spine similarly to DXA, using manual soft tissue segmentation, semi-automatic segmentation for the vertebrae, and automatic segmentation for the background. The method was assessed based on repetitive measurements of the standardized European Spine Phantom (ESP) using the standard scout scan tube current (30 mA) and other tube currents (10 to 200 mA), as well as using fat-equivalent extension rings simulating different patient habitus, and was compared to dual-energy X-ray absorptiometry (DXA). Moreover, the feasibility of the method was assessed in vivo in female patients. RESULTS: Derived from standard scout scans, aBMD values measured with the proposed method significantly correlated with DXA measurements (r = 0.9925, p < 0.001), and mean accuracy (DXA, 4.12%; scout, 1.60%) and precision (DXA, 2.64%; scout, 2.03%) were comparable between the two methods. Moreover, aBMD values assessed at different tube currents did not differ significantly (p ≥ 0.20 for all), suggesting that the presented method could be applied to scout scans with different settings. Finally, data derived from sample patients were concordant with BMD values from a reference age-matched population. CONCLUSIONS: Based on dual-layer spectral scout scans, aBMD measurements were fast and reliable and significantly correlated with the according DXA measurements in phantoms. Considering the number of CT acquisitions performed worldwide, this method could allow truly opportunistic osteoporosis screening. KEY POINTS: • 2D scout scans (localizer radiographs) from a dual-layer spectral CT scanner, which are mandatory parts of a CT examination, can be used to automatically determine areal bone mineral density (aBMD) at the spine. • The presented method allowed fast (< 25 s/patient), semi-automatic, and reliable DXA-equivalent aBMD measurements for state-of-the-art DXA phantoms at different tube settings and for various patient habitus, as well as for sample patients. • Considering the number of CT scout scan acquisitions performed worldwide on a daily basis, the presented technique could enable truly opportunistic osteoporosis screening with DXA-equivalent metrics, without involving higher radiation exposure since it only processes existing data that is acquired during each CT scan.


Assuntos
Densidade Óssea/fisiologia , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Fatores Etários , Idoso , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes , Coluna Vertebral/diagnóstico por imagem , Adulto Jovem
6.
Eur Radiol ; 29(11): 6355-6363, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31115622

RESUMO

OBJECTIVE: To investigate the in vivo applicability of non-contrast-enhanced hydroxyapatite (HA)-specific bone mineral density (BMD) measurements based on dual-layer CT (DLCT). METHODS: A spine phantom containing three artificial vertebral bodies with known HA densities was measured to obtain spectral data using DLCT and quantitative CT (QCT), simulating different patient positions and grades of obesity. BMD was calculated from virtual monoenergetic images at 50 and 200 keV. HA-specific BMD values of 174 vertebrae in 33 patients (66 ± 18 years; 33% women) were determined in non-contrast routine DLCT and compared with corresponding QCT-based BMD values. RESULTS: Examining the phantom, HA-specific BMD measurements were on a par with QCT measurements. In vivo measurements revealed strong correlations between DLCT and QCT (r = 0.987 [95% confidence interval, 0.963-1.000]; p < 0.001) and substantial agreement in a Bland-Altman plot. CONCLUSION: DLCT-based HA-specific BMD measurements were comparable with QCT measurements in in vivo analyses. This suggests that opportunistic DLCT-based BMD measurements are an alternative to QCT, without requiring phantoms and specific protocols. KEY POINTS: • DLCT-based hydroxyapatite-specific BMD measurements show a substantial agreement with QCT-based BMD measurements in vivo. • DLCT-based hydroxyapatite-specific measurements are on a par with QCT in spine phantom measurements. • Opportunistic DLCT-based BMD measurements may be a feasible alternative for QCT, without requiring dedicated examination protocols or a phantom.


Assuntos
Absorciometria de Fóton/métodos , Densidade Óssea/fisiologia , Osteoporose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Imagens de Fantasmas
7.
AJR Am J Roentgenol ; 213(2): 410-416, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31039015

RESUMO

OBJECTIVE. The purpose of this study was to systematically evaluate image quality, detectability of large-vessel occlusion or dissection, and diagnostic confidence in CT angiography (CTA) with virtually lowered tube current and iterative reconstruction in patients with suspected acute stroke. MATERIALS AND METHODS. Thirty patients (15 with large-vessel occlusion or dissection) underwent CTA of the supraaortal up to the intracranial arterial vessels. CTA scans were simulated as if they were made at 50% (D50), 25% (D25), and 10% (D10) of the original tube current. Image reconstruction was achieved with two levels of iterative reconstruction (A, similar to clinical reconstructions; B, two times stronger regularization). Two readers performed qualitative image evaluation considering overall image quality, artifacts, vessel contrast, detection of vessel abnormalities, and diagnostic confidence. RESULTS. Level B of iterative reconstruction was favorable regarding overall image quality and artifacts for D10, whereas level A was favorable for D100 and D50. CTA scans at D25 and both levels of iterative reconstruction still showed good vessel contrast, with even peripheral arterial branches of the anterior, middle, and posterior cerebral arteries being clearly detectable. Furthermore, CTA scans at D25 and level A of iterative reconstruction showed an adequate level of diagnostic confidence without any missed large-vessel occlusion or dissection according to evaluations by both readers. CONCLUSION. CTA with iterative reconstruction and tube currents decreased to 25% of that for original imaging is feasible without limitations in vessel contrast or detection of vessel abnormalities in patients with suspected acute stroke. Thus, the approach evaluated enables substantial reductions in radiation exposure for patients undergoing head and neck CTA.


Assuntos
Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Acidente Vascular Cerebral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
8.
J Comput Assist Tomogr ; 43(1): 61-65, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30211797

RESUMO

Statistical iterative reconstruction (SIR) using multidetector computed tomography (MDCT) is a promising alternative to standard filtered back projection (FBP), because of lower noise generation while maintaining image quality. Hence, we investigated the feasibility of SIR in predicting MDCT-based bone mineral density (BMD) and vertebral bone strength from finite element (FE) analysis. The BMD and FE-predicted bone strength derived from MDCT images reconstructed using standard FBP (FFBP) and SIR with (FSIR) and without regularization (FSIRB0) were validated against experimental failure loads (Fexp). Statistical iterative reconstruction produced the best quality images with regard to noise, signal-to-noise ratio, and contrast-to-noise ratio. Fexp significantly correlated with FFBP, FSIR, and FSIRB0. FFBP had a significant correlation with FSIRB0 and FSIR. The BMD derived from FBP, SIRB0, and SIR were significantly correlated. Effects of regularization should be further investigated with FE and BMD analysis to allow for an optimal iterative reconstruction algorithm to be implemented in an in vivo scenario.


Assuntos
Densidade Óssea , Análise de Elementos Finitos/estatística & dados numéricos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/métodos , Coluna Vertebral/diagnóstico por imagem , Idoso , Cadáver , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/estatística & dados numéricos , Razão Sinal-Ruído
9.
Eur Radiol ; 28(8): 3318-3325, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29460069

RESUMO

OBJECTIVES: After endovascular aortic repair (EVAR), discrimination of endoleaks and intra-aneurysmatic calcifications within the aneurysm often requires multiphase computed tomography (CT). Spectral photon-counting CT (SPCCT) in combination with a two-contrast agent injection protocol may provide reliable detection of endoleaks with a single CT acquisition. METHODS: To evaluate the feasibility of SPCCT, the stent-lined compartment of an abdominal aortic aneurysm phantom was filled with a mixture of iodine and gadolinium mimicking enhanced blood. To represent endoleaks of different flow rates, the adjacent compartments contained either one of the contrast agents or calcium chloride to mimic intra-aneurysmatic calcifications. After data acquisition with a SPCCT prototype scanner with multi-energy bins, material decomposition was performed to generate iodine, gadolinium and calcium maps. RESULTS: In a conventional CT slice, Hounsfield units (HU) of the compartments were similar ranging from 147 to 168 HU. Material-specific maps differentiate the distributions within the compartments filled with iodine, gadolinium or calcium. CONCLUSION: SPCCT may replace multiphase CT to detect endoleaks without sacrificing diagnostic accuracy. It is a unique feature of our method to capture endoleak dynamics and allow reliable distinction from intra-aneurysmatic calcifications in a single scan, thereby enabling a significant reduction of radiation exposure. KEY POINTS: • SPCCT might enable advanced endoleak detection. • Material maps derived from SPCCT can differentiate iodine, gadolinium and calcium. • SPCCT may potentially reduce radiation burden for EVAR patients under post-interventional surveillance.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Meios de Contraste , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Fótons , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Stents
10.
J Bone Miner Metab ; 36(3): 323-335, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28389933

RESUMO

Osteoporosis is characterized by bone loss and degradation of bone microstructure leading to fracture particularly in elderly people. Osteoporotic bone degeneration and fracture risk can be assessed by bone mineral density and trabecular bone score from 2D projection dual-energy X-ray absorptiometry images. However, multidetector computed tomography image based quantification of trabecular bone microstructure showed significant improvement in prediction of fracture risk beyond that from bone mineral density and trabecular bone score; however, high radiation exposure limits its use in routine clinical in vivo examinations. Hence, this study investigated reduction of radiation dose and its effects on image quality of thoracic midvertebral specimens. Twenty-four texture features were extracted to quantify the image quality from multidetector computed tomography images of 11 thoracic midvertebral specimens, by means of statistical moments, the gray-level co-occurrence matrix, and the gray-level run-length matrix, and were analyzed by an independent sample t-test to observe differences in image texture with respect to radiation doses of 80, 150, 220, and 500 mAs. The results showed that three features-namely, global variance, energy, and run percentage, were not statistically significant ([Formula: see text]) for low doses with respect to 500 mAs. Hence, it is evident that these three dose-independent features can be used for disease monitoring with a low-dose imaging protocol.


Assuntos
Osso Esponjoso/anatomia & histologia , Osso Esponjoso/efeitos da radiação , Processamento de Imagem Assistida por Computador , Doses de Radiação , Absorciometria de Fóton , Idoso , Densidade Óssea , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X
11.
J Comput Assist Tomogr ; 42(3): 441-447, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29489591

RESUMO

Multidetector computed tomography-based trabecular bone microstructure analysis ensures promising results in fracture risk prediction caused by osteoporosis. Because multidetector computed tomography is associated with high radiation exposure, its clinical routine use is limited. Hence, in this study, we investigated in 11 thoracic midvertebral specimens whether trabecular texture parameters are comparable derived from (1) images reconstructed using statistical iterative reconstruction (SIR) and filtered back projection as criterion standard at different exposures (80, 150, 220, and 500 mAs) and (2) from SIR-based sparse sampling projections (12.5%, 25%, 50%, and 100%) and equivalent exposures as criterion standard. Twenty-four texture features were computed, and those that showed similar values between (1) filtered back projection and SIR at the different exposure levels and (2) sparse sampling and equivalent exposures and reconstructed with SIR were identified. These parameters can be of equal value in determining trabecular bone microstructure with lower radiation exposure using sparse sampling and SIR.


Assuntos
Osso Esponjoso/anatomia & histologia , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Multidetectores/métodos , Idoso , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
12.
Skeletal Radiol ; 47(11): 1533-1540, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29802531

RESUMO

OBJECTIVES: To assess whether bone marrow edema in patients with acute vertebral fractures can be accurately diagnosed based on three-material decomposition with dual-layer spectral CT (DLCT). MATERIALS AND METHODS: Acute (n = 41) and chronic (n = 18) osteoporotic thoracolumbar vertebral fractures as diagnosed by MRI (hyperintense signal in STIR sequences) in 27 subjects (72 ± 11 years; 17 women) were assessed with DLCT. Spectral data were decomposed into hydroxyapatite, edema-equivalent, and fat-equivalent density maps using an in-house-developed algorithm. Two radiologists, blinded to clinical and MR findings, assessed DLCT and conventional CT independently, using a Likert scale (1 = no edema; 2 = likely no edema; 3 = likely edema; 4 = edema). For DLCT and conventional CT, accuracy, sensitivity, and specificity for identifying acute fractures (Likert scale, 3 and 4) were analyzed separately using MRI as standard of reference. RESULTS: For the identification of acute fractures, conventional CT showed a sensitivity of 0.73-0.76 and specificity of 0.78-0.83, whereas the sensitivity (0.93-0.95) and specificity (0.89) of decomposed DLCT images were substantially higher. Accuracy increased from 0.76 for conventional CT to 0.92-0.93 using DLCT. Interreader agreement for fracture assessment was high in conventional CT (weighted κ [95% confidence interval]; 0.81 [0.70; 0.92]) and DLCT (0.96 [0.92; 1.00]). CONCLUSIONS: Material decomposition of DLCT data substantially improved accuracy for the diagnosis of acute vertebral fractures, with a high interreader agreement. This may spare patients additional examinations and facilitate the diagnosis of vertebral fractures.


Assuntos
Doenças da Medula Óssea/diagnóstico por imagem , Edema/diagnóstico por imagem , Vértebras Lombares/lesões , Imageamento por Ressonância Magnética/métodos , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/lesões , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Alemanha , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Variações Dependentes do Observador , Estudos Retrospectivos , Sensibilidade e Especificidade , Vértebras Torácicas/diagnóstico por imagem
13.
Radiology ; 283(3): 723-728, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-27918709

RESUMO

Purpose To investigate the feasibility of using spectral photon-counting computed tomography (CT) to differentiate between gadolinium-based and nonionic iodine-based contrast material in a colon phantom by using the characteristic k edge of gadolinium. Materials and Methods A custom-made colon phantom was filled with nonionic iodine-based contrast material, and a gadolinium-filled capsule representing a contrast material-enhanced polyp was positioned on the colon wall. The colon phantom was scanned with a preclinical spectral photon-counting CT system to obtain spectral and conventional data. By fully using the multibin spectral information, material decomposition was performed to generate iodine and gadolinium maps. Quantitative measurements were performed within the lumen and polyp to quantitatively determine the absolute content of iodine and gadolinium. Results In a conventional CT section, absorption values of both contrast agents were similar at approximately 110 HU. Contrast material maps clearly differentiated the distributions, with gadolinium solely in the polyp and iodine in the lumen of the colon. Quantitative measurements of contrast material concentrations in the colon and polyp matched well with those of actual prepared mixtures. Conclusion Dual-contrast spectral photon-counting CT colonography with iodine-filled lumen and gadolinium-tagged polyps may enable ready differentiation between polyps and tagged fecal material. © RSNA, 2016.


Assuntos
Colonografia Tomográfica Computadorizada , Colonografia Tomográfica Computadorizada/métodos , Meios de Contraste , Gadolínio , Compostos de Iodo , Imagens de Fantasmas , Fótons
14.
Eur Radiol ; 27(12): 5261-5271, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28639046

RESUMO

OBJECTIVE: Osteoporosis diagnosis using multidetector CT (MDCT) is limited to relatively high radiation exposure. We investigated the effect of simulated ultra-low-dose protocols on in-vivo bone mineral density (BMD) and quantitative trabecular bone assessment. MATERIALS AND METHODS: Institutional review board approval was obtained. Twelve subjects with osteoporotic vertebral fractures and 12 age- and gender-matched controls undergoing routine thoracic and abdominal MDCT were included (average effective dose: 10 mSv). Ultra-low radiation examinations were achieved by simulating lower tube currents and sparse samplings at 50%, 25% and 10% of the original dose. BMD and trabecular bone parameters were extracted in T10-L5. RESULTS: Except for BMD measurements in sparse sampling data, absolute values of all parameters derived from ultra-low-dose data were significantly different from those derived from original dose images (p<0.05). BMD, apparent bone fraction and trabecular thickness were still consistently lower in subjects with than in those without fractures (p<0.05). CONCLUSION: In ultra-low-dose scans, BMD and microstructure parameters were able to differentiate subjects with and without vertebral fractures, suggesting osteoporosis diagnosis is feasible. However, absolute values differed from original values. BMD from sparse sampling appeared to be more robust. This dose-dependency of parameters should be considered for future clinical use. KEY POINTS: • BMD and quantitative bone parameters are assessable in ultra-low-dose in vivo MDCT scans. • Bone mineral density does not change significantly when sparse sampling is applied. • Quantitative trabecular bone microstructure measurements are sensitive to dose reduction. • Osteoporosis subjects could be differentiated even at 10% of original dose. • Radiation exposure should be considered when comparing quantitative bone parameters.


Assuntos
Densidade Óssea/fisiologia , Vértebras Lombares/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/instrumentação , Fraturas por Osteoporose/diagnóstico , Fraturas da Coluna Vertebral/diagnóstico , Vértebras Torácicas/diagnóstico por imagem , Abdome , Adulto , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/metabolismo , Curva ROC , Doses de Radiação , Fraturas da Coluna Vertebral/metabolismo
15.
PLoS One ; 15(7): e0235765, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32667947

RESUMO

Automatic evaluation of 3D volumes is a topic of importance in order to speed up clinical decision making. We describe a method to classify computed tomography scans on volume level for the presence of non-acute cerebral infarction. This is not a trivial task, as the lesions are often similar to other areas in the brain regarding shape and intensity. A three stage architecture is used for classification: 1) A cranial cavity segmentation network is developed, trained and applied. 2) Region proposals are generated 3) Connected regions are classified using a multi-resolution, densely connected 3D convolutional network. Mean area under curve values for subject level classification are 0.95 for the unstratified test set, 0.88 for stratification by patient age and 0.93 for stratification by CT scanner model. We use a partly segmented dataset of 555 scans of which 186 scans are used in the unstratified test set. Furthermore we examine possible dataset bias for scanner model and patient age parameters. We show a successful application of the proposed three-stage model for full volume classification. In contrast to black-box approaches, the convolutional network's decision can be further assessed by examination of intermediate segmentation results.


Assuntos
Algoritmos , Infarto Cerebral/classificação , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Idoso , Automação , Estudos de Casos e Controles , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/patologia , Feminino , Humanos , Masculino , Estudos Retrospectivos
16.
Eur J Radiol Open ; 7: 100234, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32420413

RESUMO

PURPOSE: To compare CT pulmonary angiographies (CTPAs) as well as phantom scans obtained at 100 kVp with a conventional CT (C-CT) to virtual monochromatic images (VMI) obtained with a spectral detector CT (SD-CT) at equivalent dose levels as well as to compare the radiation exposure of both systems. MATERIAL AND METHODS: In total, 2110 patients with suspected pulmonary embolism (PE) were examined with both systems. For each system (C-CT and SD-CT), imaging data of 30 patients with the same mean CT dose index (4.85 mGy) was used for the reader study. C-CT was performed with 100 kVp and SD-CT was performed with 120 kVp; for SD-CT, virtual monochromatic images (VMI) with 40, 60 and 70 keV were calculated. All datasets were evaluated by three blinded radiologists regarding image quality, diagnostic confidence and diagnostic performance (sensitivity, specificity). Contrast-to-noise ratio (CNR) for different iodine concentrations was evaluated in a phantom study. RESULTS: CNR was significantly higher with VMI at 40 keV compared to all other datasets. Subjective image quality as well as sensitivity and specificity showed the highest values with VMI at 60 keV and 70 keV. Hereby, a significant difference to 100 kVp (C-CT) was found for image quality. The highest sensitivity was found using VMI at 60 keV with a sensitivity of more than 97 % for all localizations of PE. For diagnostic confidence and subjective contrast, highest values were found with VMI at 40 keV. CONCLUSION: Higher levels of diagnostic performance and image quality were achieved for CPTAs with SD-CT compared to C-CT given similar dose levels. In the clinical setting SD-CT may be the modality of choice as additional spectral information can be obtained.

17.
Arch Osteoporos ; 15(1): 17, 2020 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-32088769

RESUMO

This study aims to evaluate the impact of dose reduction through tube current and sparse sampling on multi-detector computed tomography (MDCT)-based femoral bone strength prediction using finite element (FE) analysis. FE-predicted femoral failure load obtained from MDCT scan data was not significantly affected by 50% dose reductions through sparse sampling. Further decrease in dose through sparse sampling (25% of original projections) and virtually reduced tube current (50% and 25% of the original dose) showed significant effects on the FE-predicted failure load results. PURPOSE: To investigate the effect of virtually reduced tube current and sparse sampling on multi-detector computed tomography (MDCT)-based femoral bone strength prediction using finite element (FE) analysis. METHODS: Routine MDCT data covering the proximal femur of 21 subjects (17 males; 4 females; mean age, 71.0 ± 8.8 years) without any bone diseases aside from osteoporosis were included in this study. Fifty percent and 75% dose reductions were achieved by virtually reducing tube current and by applying a sparse sampling strategy from the raw image data. Images were then reconstructed with a statistically iterative reconstruction algorithm. FE analysis was performed on all reconstructed images and the failure load was calculated. The root mean square coefficient of variation (RMSCV) and coefficient of correlation (R2) were calculated to determine the variation in the FE-predicted failure load data for dose reductions, using original-dose MDCT scan as the standard of reference. RESULTS: Fifty percent dose reduction through sparse sampling showed lower RMSCV and higher correlations when compared with virtually reduced tube current method (RMSCV = 5.70%, R2 = 0.96 vs. RMSCV = 20.78%, R2 = 0.79). Seventy-five percent dose reduction achieved through both methods (RMSCV = 22.38%, R2 = 0.80 for sparse sampling; RMSCV = 24.58%, R2 = 0.73 for reduced tube current) could not predict the failure load accurately. CONCLUSION: Our simulations indicate that up to 50% reduction in radiation dose through sparse sampling can be used for FE-based prediction of femoral failure load. Sparse-sampled MDCT may allow fracture risk prediction and treatment monitoring in osteoporosis with less radiation exposure in the future.


Assuntos
Análise de Elementos Finitos , Tomografia Computadorizada Multidetectores/métodos , Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/etiologia , Medição de Risco/métodos , Idoso , Algoritmos , Densidade Óssea , Regras de Decisão Clínica , Feminino , Fêmur/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações
18.
Clin Neuroradiol ; 30(4): 749-759, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31696279

RESUMO

PURPOSE: To evaluate image quality and confidence for planning of periradicular infiltrations using virtually lowered tube currents and in-house developed iterative reconstruction (IR) for multidetector computed tomography (MDCT). METHODS: A total of 20 patients (mean age 54.9 ± 13.1 years) underwent MDCT for planning purposes of periradicular infiltrations at the lumbosacral spine (120 kVp and 100 mAs). Planning scans were simulated as if they were performed at 50% (D50), 10% (D10), 5% (D5), and 1% (D1) of the tube current of original scanning. Image reconstruction was achieved with two levels of IR (A: similar in appearance to clinical reconstructions, B: 10 times stronger noise reduction). Qualitative image evaluation was performed by two readers (R1 and R2) considering overall image quality and artifacts, image contrast, determination of nerve root, and confidence for intervention planning (scoring: 1 high, 2 medium, and 3 low confidence). RESULTS: Level A of IR was favorable regarding overall image quality, artifacts, image contrast, and nerve root depiction according to both readers, with preserved good to excellent scores down to D10 scans. The confidence for intervention planning was not significantly different (p > 0.05) between scans with tube currents virtually lowered down to 10% as compared to the original scans when using level A of IR (R1: 1.2 ± 0.4, R2: 1.1 ± 0.3). Inter-reader agreement for planning confidence was good to excellent (range of weighted Cohen's kappa: 0.62-1.00). CONCLUSION: The use of MDCT for planning purposes of lumbosacral periradicular infiltrations may be possible with tube currents lowered down to 10% of standard dose (equal to 10 mAs) without limitations in planning confidence.


Assuntos
Tomografia Computadorizada Multidetectores , Coluna Vertebral , Algoritmos , Artefatos , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
19.
Biomed Phys Eng Express ; 6(1): 015038, 2020 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-33438626

RESUMO

PURPOSE: To evaluate the benefit of the additional available information present in spectral CT datasets, as compared to conventional CT datasets, when utilizing convolutional neural networks for fully automatic localisation and classification of liver lesions in CT images. MATERIALS AND METHODS: Conventional and spectral CT images (iodine maps, virtual monochromatic images (VMI)) were obtained from a spectral dual-layer CT system. Patient diagnosis were known from the clinical reports and classified into healthy, cyst and hypodense metastasis. In order to compare the value of spectral versus conventional datasets when being passed as input to machine learning algorithms, we implemented a weakly-supervised convolutional neural network (CNN) that learns liver lesion localisation without pixel-level ground truth annotations. Regions-of-interest are selected automatically based on the localisation results and are used to train a second CNN for liver lesion classification (healthy, cyst, hypodense metastasis). The accuracy of lesion localisation was evaluated using the Euclidian distances between the ground truth centres of mass and the predicted centres of mass. Lesion classification was evaluated by precision, recall, accuracy and F1-Score. RESULTS: Lesion localisation showed the best results for spectral information with distances of 8.22 ± 10.72 mm, 8.78 ± 15.21 mm and 8.29 ± 12.97 mm for iodine maps, 40 keV and 70 keV VMIs, respectively. With conventional data distances of 10.58 ± 17.65 mm were measured. For lesion classification, the 40 keV VMIs achieved the highest overall accuracy of 0.899 compared to 0.854 for conventional data. CONCLUSION: An enhanced localisation and classification is reported for spectral CT data, which demonstrates that combining machine-learning technology with spectral CT information may in the future improve the clinical workflow as well as the diagnostic accuracy.


Assuntos
Algoritmos , Hepatopatias/patologia , Redes Neurais de Computação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/métodos , Humanos , Hepatopatias/classificação , Aprendizado de Máquina
20.
Clin Neuroradiol ; 29(4): 645-651, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30132090

RESUMO

PURPOSE: The aim of this study was to compare vertebral failure loads, predicted from finite element (FE) analysis of patients with and without osteoporotic vertebral fractures (OVF) at virtually reduced dose levels, compared to standard-dose exposure from multidetector computed tomography (MDCT) imaging and evaluate whether ultra-low dose derived FE analysis can still differentiate patient groups. MATERIALS AND METHODS: An institutional review board (IRB) approval was obtained for this retrospective study. A total of 16 patients were evaluated at standard-dose MDCT; eight with and eight without OVF. Images were reconstructed at virtually reduced dose levels (i. e. half, quarter and tenth of the standard dose). Failure load was determined at L1-3 from FE analysis and compared between standard, half, quarter, and tenth doses and used to differentiate between fracture and control groups. RESULTS: Failure load derived at standard dose (3254 ± 909 N and 3794 ± 984 N) did not significantly differ from half (3390 ± 890 N and 3860 ± 1063 N) and quarter dose (3375 ± 915 N and 3925 ± 990 N) but was significantly higher for one tenth dose (4513 ± 1762 N and 4766 ± 1628 N) for fracture and control groups, respectively. Failure load differed significantly between the two groups at standard, half and quarter doses, but not at tenth dose. Receiver operating characteristic (ROC) curve analysis also demonstrated that standard, half, and quarter doses can significantly differentiate the fracture from the control group. CONCLUSION: The use of MDCT enables a dose reduction of at least 75% compared to standard-dose for an adequate prediction of vertebral failure load based on non-invasive FE analysis.


Assuntos
Fraturas por Osteoporose/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fenômenos Biomecânicos , Estudos de Casos e Controles , Feminino , Análise de Elementos Finitos , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Tomografia Computadorizada Multidetectores/métodos , Fraturas por Osteoporose/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Medição de Risco/métodos , Fraturas da Coluna Vertebral/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA