Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(5): 916-928, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38439119

RESUMO

INTRODUCTION: Artificial intelligence (AI) ECG arrhythmia mapping provides arrhythmia source localization using 12-lead ECG data; whether this information impacts procedural efficiency is unknown. We performed a retrospective, case-control study to evaluate the hypothesis that AI ECG mapping may reduce time to ablation, procedural duration, and fluoroscopy. MATERIALS AND METHODS: Cases in which system output was used were retrospectively enrolled according to IRB-approved protocols at each site. Matched control cases were enrolled in reverse chronological order beginning on the last day for which the technology was unavailable. Controls were matched based upon physician, institution, arrhythmia, and a predetermined complexity rating. Procedural metrics, fluoroscopy data, and clinical outcomes were assessed from time-stamped medical records. RESULTS: The study group consisted of 28 patients (age 65 ± 11 years, 46% female, left atrial dimension 4.1 ± 0.9 cm, LVEF 50 ± 18%) and was similar to 28 controls. The most common arrhythmia types were atrial fibrillation (n = 10), premature ventricular complexes (n = 8), and ventricular tachycardia (n = 6). Use of the system was associated with a 19.0% reduction in time to ablation (133 ± 48 vs. 165 ± 49 min, p = 0.02), a 22.6% reduction in procedure duration (233 ± 51 vs. 301 ± 83 min, p < 0.001), and a 43.7% reduction in fluoroscopy (18.7 ± 13.3 vs. 33.2 ± 18.0 min, p < 0.001) versus controls. At 6 months follow-up, arrhythmia-free survival was 73.5% in the study group and 63.3% in the control group (p = 0.56). CONCLUSION: Use of forward-solution AI ECG mapping is associated with reductions in time to first ablation, procedure duration, and fluoroscopy without an adverse impact on procedure outcomes or complications.


Assuntos
Potenciais de Ação , Arritmias Cardíacas , Inteligência Artificial , Ablação por Cateter , Valor Preditivo dos Testes , Tempo para o Tratamento , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Fluoroscopia , Frequência Cardíaca , Duração da Cirurgia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estudos de Casos e Controles
2.
Circ Res ; 128(2): 172-184, 2021 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-33167779

RESUMO

RATIONALE: Susceptibility to VT/VF (ventricular tachycardia/fibrillation) is difficult to predict in patients with ischemic cardiomyopathy either by clinical tools or by attempting to translate cellular mechanisms to the bedside. OBJECTIVE: To develop computational phenotypes of patients with ischemic cardiomyopathy, by training then interpreting machine learning of ventricular monophasic action potentials (MAPs) to reveal phenotypes that predict long-term outcomes. METHODS AND RESULTS: We recorded 5706 ventricular MAPs in 42 patients with coronary artery disease and left ventricular ejection fraction ≤40% during steady-state pacing. Patients were randomly allocated to independent training and testing cohorts in a 70:30 ratio, repeated K=10-fold. Support vector machines and convolutional neural networks were trained to 2 end points: (1) sustained VT/VF or (2) mortality at 3 years. Support vector machines provided superior classification. For patient-level predictions, we computed personalized MAP scores as the proportion of MAP beats predicting each end point. Patient-level predictions in independent test cohorts yielded c-statistics of 0.90 for sustained VT/VF (95% CI, 0.76-1.00) and 0.91 for mortality (95% CI, 0.83-1.00) and were the most significant multivariate predictors. Interpreting trained support vector machine revealed MAP morphologies that, using in silico modeling, revealed higher L-type calcium current or sodium-calcium exchanger as predominant phenotypes for VT/VF. CONCLUSIONS: Machine learning of action potential recordings in patients revealed novel phenotypes for long-term outcomes in ischemic cardiomyopathy. Such computational phenotypes provide an approach which may reveal cellular mechanisms for clinical outcomes and could be applied to other conditions.


Assuntos
Cardiomiopatias/diagnóstico , Morte Súbita Cardíaca/etiologia , Diagnóstico por Computador , Técnicas Eletrofisiológicas Cardíacas , Redes Neurais de Computação , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/etiologia , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Fenótipo , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
3.
Europace ; 22(6): 897-905, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32243508

RESUMO

AIMS: Persistent atrial fibrillation (AF) has been explained by multiple mechanisms which, while they conflict, all agree that more disorganized AF is more difficult to treat than organized AF. We hypothesized that persistent AF consists of interacting organized areas which may enlarge, shrink or coalesce, and that patients whose AF areas enlarge by ablation are more likely to respond to therapy. METHODS AND RESULTS: We mapped vectorial propagation in persistent AF using wavefront fields (WFF), constructed from raw unipolar electrograms at 64-pole basket catheters, during ablation until termination (Group 1, N = 20 patients) or cardioversion (Group 2, N = 20 patients). Wavefront field mapping of patients (age 61.1 ± 13.2 years, left atrium 47.1 ± 6.9 mm) at baseline showed 4.6 ± 1.0 organized areas, each separated by disorganization. Ablation of sites that led to termination controlled larger organized area than competing sites (44.1 ± 11.1% vs. 22.4 ± 7.0%, P < 0.001). In Group 1, ablation progressively enlarged unablated areas (rising from 32.2 ± 15.7% to 44.1 ± 11.1% of mapped atrium, P < 0.0001). In Group 2, organized areas did not enlarge but contracted during ablation (23.6 ± 6.3% to 15.2 ± 5.6%, P < 0.0001). CONCLUSION: Mapping wavefront vectors in persistent AF revealed competing organized areas. Ablation that progressively enlarged remaining areas was acutely successful, and sites where ablation terminated AF were surrounded by large organized areas. Patients in whom large organized areas did not emerge during ablation did not exhibit AF termination. Further studies should define how fibrillatory activity is organized within such areas and whether this approach can guide ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardioversão Elétrica , Átrios do Coração/cirurgia , Humanos , Pessoa de Meia-Idade
5.
J Cardiovasc Electrophysiol ; 28(10): 1158-1166, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28670858

RESUMO

INTRODUCTION: Ventricular fibrillation is a common life-threatening arrhythmia. The ECG of VF appears chaotic but may allow identification of sustaining mechanisms to guide therapy. HYPOTHESIS: We hypothesized that rotors and focal sources manifest distinct features on the ECG, and computational modeling may identify mechanisms of such features. METHODS: VF induction was attempted in 31 patients referred for ventricular arrhythmia ablation. Simultaneous surface ECG and intracardiac electrograms were recorded using biventricular basket catheters. Endocardial phase maps were used to mechanistically classify each VF cycle as rotor or focally driven. ECGs were analyzed from patients demonstrating both mechanisms in the primary analysis and from all patients with induced VF in the secondary analysis. The ECG voltage variation during each mechanism was compared. Biventricular computer simulations of VF driven by focal sources or rotors were created and resulting ECGs of each VF mechanism were compared. RESULTS: Rotor-based VF exhibited greater voltage variation than focal source-based VF in both the primary analysis (n = 8, 110 ± 24% vs. 55 ± 32%, P = 0.02) and the secondary analysis (n = 18, 103 ± 30% vs. 67 ± 34%, P = 0.009). Computational VF simulations also revealed greater voltage variation in rotors compared to focal sources (110 ± 19% vs. 33 ± 16%, P = 0.001), and demonstrated that this variation was due to wavebreak, secondary rotor initiation, and rotor meander. CONCLUSION: Clinical and computational studies reveal that quantitative criteria of ECG voltage variation differ significantly between VF-sustaining rotors and focal sources, and provide insight into the mechanisms of such variation. Future studies should prospectively evaluate if these criteria can separate clinical VF mechanisms and guide therapy.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia , Idoso , Ablação por Cateter , Catéteres , Simulação por Computador , Fenômenos Eletrofisiológicos , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Fibrilação Ventricular/terapia
6.
Europace ; 19(5): 769-774, 2017 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339546

RESUMO

AIMS: Focal Impulse and Rotor Modulation (FIRM) uses 64-electrode basket catheters to identify atrial fibrillation (AF)-sustaining sites for ablation, with promising results in many studies. Accordingly, new basket designs are being tested by several groups. We set out to determine the procedural safety of adding basket mapping and map-guided ablation to conventional pulmonary vein isolation (PVI). METHODS AND RESULTS: We collected 30 day procedural safety data in five US centres for consecutive patients undergoing FIRM plus PVI (FIRM-PVI) compared with contemporaneous controls undergoing PVI without FIRM. A total of 625 cases were included in this analysis: 325 FIRM-PVI and 300 PVI-controls. FIRM-PVI patients were more likely than PVI-controls to be male (83% vs. 66%, P < 0.001) and have long-standing persistent AF (26% vs. 13%, P < 0.001) reflecting patients referred for FIRM. Total ablation time was greater for FIRM-PVI (62 ± 22 min) vs. PVI-controls (52 ± 18 min, P = 0.03). The complication rate for FIRM-PVI procedures (4.3%) was similar to controls (4.0%, P = 1) for both major and minor complications; no deaths were reported. The rate of complications potentially attributable to the basket catheter was small and did not differ between basket types (Constellation 2.8% vs. FIRMap 1.8%, P = 0.7) or between cases in which basket catheters were and were not used (P = 0.5). Complication rates did not differ between centres (P = 0.6). CONCLUSIONS: Procedural complications from the use of the basket catheters for AF mapping are low, and thus procedural safety appears similar between FIRM-PVI and PVI-controls in a large multicentre cohort. Future studies are required to determine the optimal approach to maximize the efficacy of FIRM-guided ablation.


Assuntos
Fibrilação Atrial/mortalidade , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/mortalidade , Ablação por Cateter/mortalidade , Ablação por Cateter/estatística & dados numéricos , Complicações Pós-Operatórias/mortalidade , Cirurgia Assistida por Computador/mortalidade , Fibrilação Atrial/diagnóstico por imagem , Mapeamento Potencial de Superfície Corporal/métodos , Mapeamento Potencial de Superfície Corporal/estatística & dados numéricos , Ablação por Cateter/métodos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Fatores de Risco , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologia
7.
J Electrocardiol ; 50(3): 307-315, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28108014

RESUMO

BACKGROUND: During ablation for atrial fibrillation (AF), it is challenging to anticipate transitions to organized tachycardia (AT). Defining indices of this transition may help to understand fibrillatory conduction and help track therapy. OBJECTIVE: To determine the timescale over which atrial fibrillation (AF) organizes en route to atrial tachycardia (AT) using the ECG referenced to intracardiac electrograms. METHODS: In 17 AF patients at ablation (58.7±9.6years; 53% persistent AF) we analyzed spatial loops of atrial activity on the ECG and intracardiac electrograms over successive timepoints. Loops were tracked at precisely 15, 10, 5, 3 and 1min prior to defined transitions of AF to AT. RESULTS: Organizational indices reliably quantified changes from AF to AT. Spatiotemporal AF organization on the ECG was identifiable at least 15min before AT was established (p=0.02). CONCLUSIONS: AF shows anticipatory global organization on the ECG minutes before AT is clinically evident. These results offer a foundation to establish when AF therapy is on an effective path, and for a quantitative classification separating AT from AF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Eletroencefalografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Monitorização Intraoperatória/métodos , Taquicardia Atrial Ectópica/diagnóstico por imagem , Taquicardia Atrial Ectópica/cirurgia , Fibrilação Atrial/complicações , Ablação por Cateter , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Taquicardia Atrial Ectópica/etiologia , Resultado do Tratamento
8.
J Cardiovasc Electrophysiol ; 27(6): 661-9, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26918971

RESUMO

INTRODUCTION: Recurrent atrial fibrillation (AF) after ablation is associated with reconnection of initially isolated pulmonary vein (PV) trigger sites. Substrates are often targeted in addition to PVI, but it is unclear how substrates progress over time. We studied if substrates in recurrent AF are conserved or have developed de novo from pre-ablation AF. METHODS AND RESULTS: Of 137 patients undergoing Focal Impulse and Rotor Mapping (FIRM) at their index procedure for AF, 29 consecutive patients (60 ± 8 years, 79% persistent) recurred and were also mapped at repeat procedure (21 ± 20 months later) using carefully placed 64-pole baskets and RhythmView(TM) (Topera, Menlo Park, CA, USA) to identify AF sources and disorganized zones. Compared to index AF, recurrent AF had a longer cycle length (177 ± 21 vs. 167 ± 19 milliseconds, P = 0.01). All patients (100%) had 1 or more conserved AF rotors between procedures with surrounding disorganization. The number of sources was similar for recurrent AF post-PVI versus index AF (3.2 ± 1.4 vs. 3.1 ± 1.0, P = 0.79), but was lower for recurrent AF after FIRM+PVI versus index AF (4.4 ± 1.4 vs. 2.9 ± 1.7, P = 0.03). Overall, 81% (61/75) of AF sources lay in conserved regions, while 19% (14/75) were detected de novo. CONCLUSION: Electrical propagation patterns for recurrent AF after unsuccessful ablation are similar in individual patients to their index AF. These data support temporospatial stability of AF substrates over 1-2 years. Trials should determine the relative benefit of adding substrate mapping and ablation to PVI for recurrent AF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Falha de Tratamento
9.
Europace ; 18(suppl 4): iv104-iv112, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28011837

RESUMO

AIMS: Left ventricular activation delay due to left bundle branch block (LBBB) is an important determinant of the severity of dyssynchronous heart failure (DHF). We investigated whether patient-specific computational models constructed from non-invasive measurements can provide measures of baseline dyssynchrony and its reduction after CRT that may explain the degree of long-term reverse ventricular remodelling. METHODS AND RESULTS: LV end-systolic volume reduction (ΔESVLV) measured by 2D trans-thoracic echocardiography in eight patients following 6 months of CRT was significantly (P < 0.05) greater in responders (26 ± 20%, n = 4) than non-responders (11 ± 16%, n = 4). LV reverse remodelling did not correlate with baseline QRS duration or its change after biventricular pacing, but did correlate with baseline LV endocardial activation measured by electroanatomic mapping (R2 = 0.71, P < 0.01). Patient-specific models of LBBB ventricular activation with parameters obtained by matching model-computed vectorcardiograms (VCG) to those derived from standard patient ECGs yielded LV endocardial activation times that correlated well with those measured from endocardial maps (R2 = 0.90). Model-computed 3D LV activation times correlated strongly with the reduction in LVESV (R2 = 0.93, P < 0.001). Computed decreases due to simulated CRT in the time delay between LV septal and lateral activation correlated strongly with ΔESVLV (R2 = 0.92, P < 0.001). Models also suggested that optimizing VV delays may improve resynchronization by this measure of activation delay. CONCLUSIONS: Patient-specific computational models constructed from non-invasive measurements can compute estimates of LV dyssynchrony and their changes after CRT that may be as good as or better than electroanatomic mapping for predicting long-term reverse remodelling.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Potenciais de Ação , Idoso , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Processamento de Sinais Assistido por Computador , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Vetorcardiografia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular
10.
Pacing Clin Electrophysiol ; 39(11): 1254-1260, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27550834

RESUMO

BACKGROUND: Radiofrequency (RF) technology has improved detection of retained surgical sponges with a reported 100% sensitivity and specificity. However, the potential for interactions of the RF signals emitted by the detection system with cardiac implantable electronic devices (CIEDs) or temporary pacemakers may limit its use in those patients with these devices. This study investigated whether RF detection technology causes interference or clinically significant changes in the programmed settings of implanted pacemakers and defibrillators or temporary epicardial pacemakers. METHODS: Fifty patients who were scheduled either for CIED removal or placement of a temporary epicardial pacemaker (at the time of open heart surgery) were recruited for this study. Device settings and measurements from separate interrogations before and after scanning with the RF detection system were compared. For the temporary pacemakers, we observed for any changes in hemodynamics or signs of pacing interference. RESULTS: Twenty (40%) pacemakers, 20 (40%) implantable cardioverter defibrillators, and 10 (20%) temporary pacemakers were analyzed in this study. During scanning, no signal interference was detected in any permanent device, and there were no significant changes in programmed settings after scanning with the RF detection system. However, pacing inhibition was detected with temporary pacing systems when programmed to a synchronous mode (DDD). CONCLUSIONS: RF detection technology can be safely used to scan for retained surgical sponges in patients with permanent CIEDs and temporary pacemakers set to asynchronous mode.


Assuntos
Desfibriladores Implantáveis , Corpos Estranhos/diagnóstico , Marca-Passo Artificial , Ondas de Rádio , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
J Cardiovasc Electrophysiol ; 26(10): 1117-26, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26179310

RESUMO

INTRODUCTION: Recent work has suggested a role for organized sources in sustaining ventricular fibrillation (VF). We assessed whether ablation of rotor substrate could modulate VF inducibility in canines, and used this proof-of-concept as a foundation to suppress antiarrhythmic drug-refractory clinical VF in a patient with structural heart disease. METHODS AND RESULTS: In 9 dogs, we introduced 64-electrode basket catheters into one or both ventricles, used rapid pacing at a recorded induction threshold to initiate VF, and then defibrillated after 18±8 seconds. Endocardial rotor sites were identified from basket recordings using phase mapping, and ablation was performed at nonrotor (sham) locations (7 ± 2 minutes) and then at rotor sites (8 ± 2 minutes, P = 0.10 vs. sham); the induction threshold was remeasured after each. Sham ablation did not alter canine VF induction threshold (preablation 150 ± 16 milliseconds, postablation 144 ± 16 milliseconds, P = 0.54). However, rotor site ablation rendered VF noninducible in 6/9 animals (P = 0.041), and increased VF induction threshold in the remaining 3. Clinical proof-of-concept was performed in a patient with repetitive ICD shocks due to VF refractory to antiarrhythmic drugs. Following biventricular basket insertion, VF was induced and then defibrillated. Mapping identified 4 rotors localized at borderzone tissue, and rotor site ablation (6.3 ± 1.5 minutes/site) rendered VF noninducible. The VF burden fell from 7 ICD shocks in 8 months preablation to zero ICD therapies at 1 year, without antiarrhythmic medications. CONCLUSIONS: Targeted rotor substrate ablation suppressed VF in an experimental model and a patient with refractory VF. Further studies are warranted on the efficacy of VF source modulation.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Sistema de Condução Cardíaco/cirurgia , Cirurgia Assistida por Computador/métodos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/cirurgia , Animais , Cães , Estudos de Viabilidade , Projetos Piloto , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 25(12): 1284-92, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25263408

RESUMO

INTRODUCTION: Several groups report electrical rotors or focal sources that sustain atrial fibrillation (AF) after it has been triggered. However, it is difficult to separate stable from unstable activity in prior studies that examined only seconds of AF. We applied phase-based focal impulse and rotor mapping (FIRM) to study the dynamics of rotors/sources in human AF over prolonged periods of time. METHODS: We prospectively mapped AF in 260 patients (169 persistent, 61 ± 12 years) at 6 centers in the FIRM registry, using baskets with 64 contact electrodes per atrium. AF was phase mapped (RhythmView, Topera, Menlo Park, CA, USA). AF propagation movies were interpreted by each operator to assess the source stability/dynamics over tens of minutes before ablation. RESULTS: Sources were identified in 258 of 260 of patients (99%), for 2.8 ± 1.4 sources/patient (1.8 ± 1.1 in left, 1.1 ± 0.8 in right atria). While AF sources precessed in stable regions, emanating activity including spiral waves varied from collision/fusion (fibrillatory conduction). Each source lay in stable atrial regions for 4,196 ± 6,360 cycles, with no differences between paroxysmal versus persistent AF (4,290 ± 5,847 vs. 4,150 ± 6,604; P = 0.78), or right versus left atrial sources (P = 0.26). CONCLUSIONS: Rotors and focal sources for human AF mapped by FIRM over prolonged time periods precess ("wobble") but remain within stable regions for thousands of cycles. Conversely, emanating activity such as spiral waves disorganize and collide with the fibrillatory milieu, explaining difficulties in using activation mapping or signal processing analyses at fixed electrodes to detect AF rotors. These results provide a rationale for targeted ablation at AF sources rather than fibrillatory spiral waves.


Assuntos
Algoritmos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Relógios Biológicos , Mapeamento Potencial de Superfície Corporal/métodos , Sistema de Condução Cardíaco/fisiopatologia , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Condução Nervosa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
13.
J Cardiovasc Electrophysiol ; 25(9): 921-929, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24948520

RESUMO

INTRODUCTION: The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers. METHODS: We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View(TM) ; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI. RESULTS: Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145-354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89). CONCLUSIONS: Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center's first cases.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
14.
Circ J ; 78(10): 2357-66, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25213002

RESUMO

Outcomes for patients with atrial fibrillation (AF) have changed little despite many advances in technology. In large part, this reflects fundamental uncertainty about the mechanisms for AF in humans, which must reconcile diverse observations. Despite the complexity of AF, many electrophysiologists have witnessed modulation of 'chaotic' AF after the first few ablation lesions, or before lines are complete or trigger sites are isolated, and numerous analyses demonstrate temporospatial stability in AF. These common observations challenge the concept that AF is driven by spatially disorganized, widespread mechanisms. Using mathematical techniques applied to other complex systems, evidence is rapidly accumulating that human AF is largely sustained by localized rotors and focal sources. Elimination of sources by Focal Impulse and Rotor Modulation (FIRM)-guided ablation has been shown by independent laboratories to substantially improve success compared with pulmonary vein isolation alone. These data advance our mechanistic understanding of AF. Randomized trials are underway to verify the relative efficacy of ablation at AF sources (substrate) vs. conventional trigger ablation. The renewed focus on AF substrates is a paradigm shift, but also a re-alignment of concepts for AF towards those for other cardiac arrhythmias that are generally defined by sustaining mechanisms (substrates).


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Fenômenos Eletrofisiológicos , Modelos Cardiovasculares , Humanos
15.
Curr Cardiol Rep ; 16(8): 509, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24950671

RESUMO

Atrial fibrillation (AF) is the most common arrhythmia targeted by catheter ablation. Despite significant advances in our understanding of AF, ablation outcomes remain suboptimal, and this is due in large part to an incomplete understanding of the underlying sustaining mechanisms of AF. Recent developments of patient-tailored and physiology-based computational mapping systems have identified localized electrical spiral waves, or rotors, and focal sources as mechanisms that may represent novel targets for therapy. This report provides an overview of Focal Impulse and Rotor Modulation (FIRM) mapping, which reveals that human AF is often not actually driven by disorganized activity but instead that disorganization is secondary to organized rotors or focal sources. Targeted ablation of such sources alone can eliminate AF and, when added to pulmonary vein isolation, improves long-term outcome compared with conventional ablation alone. Translating mechanistic insights from such patient-tailored mapping is likely to be crucial in achieving the next major advances in personalized medicine for AF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Fibrilação Atrial/fisiopatologia , Eletrocardiografia/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Humanos
16.
Heart Rhythm O2 ; 5(2): 131-136, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38545321

RESUMO

Background: Respiratory motion management strategies are used to minimize the effects of breathing on the precision of stereotactic ablative radiotherapy for ventricular tachycardia, but the extent of cardiac contractile motion of the human heart has not been systematically explored. Objective: We aim to assess the magnitude of cardiac contractile motion between different directions and locations in the heart. Methods: Patients with intracardiac leads or valves who underwent 4-dimensional cardiac computed tomography (CT) prior to a catheter ablation procedure for atrial or ventricular arrhythmias at 2 medical centers were studied retrospectively. The displacement of transvenous right atrial appendage, right ventricular (RV) implantable cardioverter-defibrillator, coronary sinus lead tips, and prosthetic cardiac devices across the cardiac cycle were measured in orthogonal 3-dimensional views on a maximal-intensity projection CT reconstruction. Results: A total of 31 preablation cardiac 4-dimensional cardiac CT scans were analyzed. The LV lead tip had significantly greater motion compared with the RV lead in the anterior-posterior direction (6.0 ± 2.2 mm vs 3.8 ± 1.7 mm; P = .01) and superior-inferior direction (4.4 ± 2.9 mm vs 3.5 ± 2.0 mm; P = .049). The prosthetic aortic valves had the least movement of all fiducials, specifically compared with the RV lead tip in the left-right direction (3.2 ± 1.2 mm vs 6.1 ± 3.8 mm, P = .04) and the LV lead tip in the anterior-posterior direction (3.8 ± 1.7 mm vs 6.0 ± 2.2 mm, P = .03). Conclusion: The degree of cardiac contractile motion varies significantly (1 mm to 15.2 mm) across different locations in the heart. The effect of contractile motion on the precision of radiotherapy should be assessed on a patient-specific basis.

17.
bioRxiv ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38798676

RESUMO

In patients with dyssynchronous heart failure (DHF), cardiac conduction abnormalities cause the regional distribution of myocardial work to be non-homogeneous. Cardiac resynchronization therapy (CRT) using an implantable, programmed biventricular pacemaker/defibrillator, can improve the synchrony of contraction between the right and left ventricles in DHF, resulting in reduced morbidity and mortality and increased quality of life. Since regional work depends on wall stress, which cannot be measured in patients, we used computational methods to investigate regional work distributions and their changes after CRT. We used three-dimensional multi-scale patient-specific computational models parameterized by anatomic, functional, hemodynamic, and electrophysiological measurements in eight patients with heart failure and left bundle branch block (LBBB) who received CRT. To increase clinical translatability, we also explored whether streamlined computational methods provide accurate estimates of regional myocardial work. We found that CRT increased global myocardial work efficiency with significant improvements in non-responders. Reverse ventricular remodeling after CRT was greatest in patients with the highest heterogeneity of regional work at baseline, however the efficacy of CRT was not related to the decrease in overall work heterogeneity or to the reduction in late-activated regions of high myocardial work. Rather, decreases in early-activated regions of myocardium performing negative myocardial work following CRT best explained patient variations in reverse remodeling. These findings were also observed when regional myocardial work was estimated using ventricular pressure as a surrogate for myocardial stress and changes in endocardial surface area as a surrogate for strain. These new findings suggest that CRT promotes reverse ventricular remodeling in human dyssynchronous heart failure by increasing regional myocardial work in early-activated regions of the ventricles, where dyssynchrony is specifically associated with hypoperfusion, late systolic stretch, and altered metabolic activity and that measurement of these changes can be performed using streamlined approaches.

18.
J Cardiovasc Electrophysiol ; 24(8): 926-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23574305

RESUMO

INTRODUCTION: Electrical storm is a condition characterized by multiple episodes of ventricular tachycardia (VT) or ventricular fibrillation (VF) in a short period of time. CASE PRESENTATION: An 80-year-old male with a history of ischemic cardiomyopathy presented with multiple ICD shocks. As a last resort, he underwent percutaneous left, followed by right, stellate ganglion block under fluoroscopic guidance. Since his discharge, he has been managed with alternating, biweekly left and right stellate ganglion blocks, and he has received no ICD shocks. DISCUSSION: This case illustrates the potential of ongoing, temporary percutaneous stellate ganglion blockade in suppressing ventricular arrhythmogenesis.


Assuntos
Bloqueio Nervoso/métodos , Gânglio Estrelado/fisiopatologia , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/prevenção & controle , Fibrilação Ventricular/fisiopatologia , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis , Fluoroscopia , Humanos , Masculino
19.
Europace ; 15(9): 1249-58, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23449925

RESUMO

AIMS: To develop electrocardiogram (ECG) tools to quantify the number of sources for atrial fibrillation (AF), i.e. spatially stable rotors and focal impulses, and whether they lie in right or left atrium. Intracardiac mapping has recently shown that paroxysmal and persistent AF is sustained by rotors or focal sources that are stable in location and thus targets for limited ablation [focal impulse and rotor modulation (FIRM)] to eliminate AF. Importantly, the numbers and locations of concurrent sources determine both the complexity of AF and the approach for ablation. METHODS AND RESULTS: In 36 AF patients (n = 29 persistent, 63 ± 9 years) in the CONventional ablation with or without Focal Impulse and Rotor Modulation (CONFIRM) trial, we developed phase lock (PL) to quantify spatial repeatability of ECG 'F-waves' between leads over time. Phase lock spectrally quantifies the angle θ between F-wave voltages in planes formed by ECG leads I, aVF, and V1 at successive points in time. We compared PL with ECG spectral dominant frequency (DF) and organizational index (OI) to characterize stable rotors and focal sources validated by intracardiac FIRM mapping. Focal impulse and rotor modulation ablation alone at ≤3 sources acutely terminated and rendered AF non-inducible or substantially slowed AF in 31 of 36 patients. Receiver operating characteristics of PL for this endpoint had area under the curve (AUC) = 0.72, and the optimum cut-point (PL = 0.09) had 74% sensitivity, 92% positive predictive value (PPV). Receiver operating characteristics areas for OI and DF were 0.50 and 0.58, respectively. Left (n = 28) or right (n = 3) atrial sources were localized by PL with AUC = 0.85, sensitivity 100%, PPV 30%, and negative predictive value 100%. Spectral DF provided AUC = 0.79. Notably, PL did not comigrate with diagnosis of paroxysmal or persistent AF (P = NS), unlike ECG DF. CONCLUSION: The novel metric of ECG PL identifies patients with fewer (≤3) or greater numbers of stable rotors/focal sources for AF, validated by intracardiac FIRM mapping, and localized them to right or left atria. These data open the possibility of using 12-lead ECG analyses to classify AF mechanistically and plan procedures for right- or left-sided FIRM ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Relógios Biológicos , Mapeamento Potencial de Superfície Corporal/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Modelos Cardiovasculares , Simulação por Computador , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
JACC Case Rep ; 15: 101870, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37283824

RESUMO

In patients presenting with refractory ventricular tachycardia (VT) and aortic and mitral mechanical prosthetic valves, traditional catheter ablation is challenging. We describe a case in which a novel noninvasive computational electrocardiogram mapping algorithm localized VT sources originating from substrate near the mechanical valves, in which stereotactic ablative radiotherapy eliminated VT in 1.5-year follow-up. (Level of Difficulty: Advanced.).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA