Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Int J Clin Oncol ; 28(12): 1625-1632, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37875767

RESUMO

BACKGROUND: Body weight loss (BWL) is a serious complication of gastrectomy in patients with gastric cancer (GC). Nutritional intervention alone is inadequate for preventing BWL, and a new approach is needed. Oral frailty among older adults has recently attracted attention. This study aimed to investigate masticatory ability and BWL after gastrectomy. METHODS: This was a single-center, retrospective study. Functional tooth units (FTU) were used to measure masticatory ability. Patients with FTU < 4 were defined as low FTU group and FTU ≥ 4 as high FTU group. The BWL was compared between the two groups. RESULTS: Sixty patients who underwent distal gastrectomy for GC from March 2022 to January 2023 were enrolled in this study. The median FTU was 3 (range 0-12). The low-FTU group (FTU < 4) included 29 patients, while the high-FTU group (FTU ≥ 4) included 31 patients. The %BWL in the low FTU group was significantly higher than that in the high-FTU group at 1 and 3 months (p = 0.003 and p = 0.017, respectively). The risk factors associated with a %BWL > 5 at 1 and 3 months after gastrectomy were analyzed using logistic regression analysis. Only FTU < 4 was an independent risk factor after gastrectomy for GC in univariate and multivariate analyses (p = 0.028 and p = 0.006, respectively). CONCLUSIONS: Low FTU in patients with preoperative GC was a risk factor for %BWL 1 and 3 months postoperatively. Appropriate oral interventions may be useful in improving the postoperative nutritional status after gastrectomy.


Assuntos
Fragilidade , Neoplasias Gástricas , Humanos , Idoso , Estudos Retrospectivos , Redução de Peso , Fragilidade/etiologia , Fragilidade/cirurgia , Gastrectomia/efeitos adversos , Fatores de Risco , Neoplasias Gástricas/cirurgia
2.
Gan To Kagaku Ryoho ; 48(13): 1685-1687, 2021 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-35046297

RESUMO

A 69-year-old female underwent a mesh repair for an abdominal incisional hernia 4 years previously in our hospital. She visited local hospital for abdominal pain and fever. Abdominal CT showed a localizes abscess formation above the mesh, then she was taken to our hospital. We suspected mesh infection and performed emergent mesh removal. After the operation, we examined for her anemia. Her colonoscopy and CT findings pointed to transverse colon cancer. We performed right hemicolectomy, and final diagnosis was transverse colon cancer pT4aN0M0, pStage Ⅱb. She underwent adjuvant chemotherapy, and 9 months after surgery, no recurrence was found.


Assuntos
Colo Transverso , Neoplasias do Colo , Idoso , Colectomia , Colo Transverso/cirurgia , Neoplasias do Colo/complicações , Neoplasias do Colo/tratamento farmacológico , Neoplasias do Colo/cirurgia , Feminino , Humanos , Recidiva Local de Neoplasia , Telas Cirúrgicas
3.
Gan To Kagaku Ryoho ; 47(13): 2239-2241, 2020 Dec.
Artigo em Japonês | MEDLINE | ID: mdl-33468920

RESUMO

A 60's woman was admitted to our hospital because of palpitations that occurred with exertion. Coronary angiography computed tomography(CT)of suspected angina detected a tumor in the pancreatic head region. Abdominal CT showed a poorly enhanced 40×32 mm solid tumor in the hepatoduodenal ligament that contained a fatty component and calcification. During surgery, the tumor was located in the hepatoduodenal ligament, adhered to the pancreatic head, common hepatic artery, gastroduodenal artery, portal vein and common bile duct. However, the tumor was resected by preserving them. The tumor contained stratified squamous epithelium, a sebaceous gland, nerve, a pancreatic gland, and an adrenal gland. The histological diagnosis was a mature cystic teratoma. The patient showed no recurrence in 2 years and 10 months post-surgery. Mature teratomas in the hepatoduodenal ligament are extremely rare. Some reports showed that combined resection was performed when the tumor was in contact with the common bile duct, portal vein, and arteries. However, in our case, the tumor was removed relatively safely without combined resection.


Assuntos
Recidiva Local de Neoplasia , Teratoma , Feminino , Humanos , Ligamentos/cirurgia , Fígado , Omento , Teratoma/cirurgia
4.
J Infect Chemother ; 21(8): 610-2, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25960155

RESUMO

BACKGROUND: Acute rheumatic fever (ARF) is an illness caused by group A streptococcus (GAS) infection, and remains the leading cause of acquired heart disease in worldwide. Distinguishing between ARF and septic arthritis may be difficult. This report describes a case of suppurative arthritis overlapping with ARF. CASE PRESENTATION: A 4-year-old, previously healthy boy presented with fever and left leg pain. The level of anti-streptolysin O (ASO) was elevated. His throat swab cultures grew GAS, but none were detected in his synovial fluid. Magnetic resonance imaging revealed suspected arthritis and osteomyelitis. The patient was treated for septic arthritis, but was subsequently diagnosed with ARF, after the development of carditis. CONCLUSION: The clinical and laboratory features of ARF and suppurative arthritis demonstrate substantial overlap. Patients with an elevated ASO should undergo a careful cardiac examination for carditis associated with ARF by an echocardiogram.


Assuntos
Artrite Infecciosa/diagnóstico , Artrite Juvenil/diagnóstico , Osteomielite/diagnóstico , Febre Reumática/diagnóstico , Febre Reumática/tratamento farmacológico , Infecções Estreptocócicas/complicações , Streptococcus pyogenes/isolamento & purificação , Doença Aguda , Artrite Infecciosa/microbiologia , Artrite Juvenil/microbiologia , Pré-Escolar , Diagnóstico Diferencial , Humanos , Masculino , Miocardite/microbiologia , Osteomielite/microbiologia , Febre Reumática/microbiologia , Infecções Estreptocócicas/tratamento farmacológico
5.
Eur J Orthop Surg Traumatol ; 24(8): 1531-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24442384

RESUMO

INTRODUCTION: The level and morphology of posterior cruciate ligament (PCL) attachment vary greatly among individuals, and the function of the PCL after tibial osteotomy performed during total knee arthroplasty (TKA) surgery remains unclear. Therefore, we evaluated the resection amount of PCL attachment and the function of the residual PCL in cruciate-retaining (CR)-type TKA. METHODS: We examined 76 patients with knee osteoarthritis who had undergone CR-type TKA. The level of the tibial PCL attachment was measured by preoperative MRI and the amount resected into the tibial PCL attachment from the osteotomy level as well as the longitudinal diameter of the residual PCL by postoperative radiography. The relationships between these and joint gap tension value at flexion or amount of tibial posterior transfer by postoperative stress radiography were examined. RESULTS: The longitudinal diameter of the PCL attachment and the attachment level varied widely among patients. There were 39 patients (51%) with tibial osteotomy level caudal to the PCL attachment. Flexion gap tension in patients with residual PCL (residual PCL group) was slightly higher than those without residual PCL (fully-resected group). There was no correlation between amount of PCL residual and joint gap tension at the flexion position. Even in those without residual PCL, no correlation was observed between the resected amount and flexion joint gap tension value. Comparison of amount of posterior transfer by postoperative stress radiography between those with and without residual PCL revealed no significant difference. CONCLUSIONS: It was confirmed that the level and morphology of the PCL attachment vary greatly among individuals and the amount of PCL resected at tibial osteotomy during TKA surgery varies depending on the patient. The tension due to flexion position tended to decrease if the tibial osteotomy line was caudal to the PCL attachment; however, the amount of tibial posterior transfer due to stress was not changed.


Assuntos
Artroplastia de Substituição do Tornozelo/métodos , Osteotomia/métodos , Ligamento Cruzado Posterior/cirurgia , Tíbia/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Ligamento Cruzado Posterior/anatomia & histologia , Radiografia , Amplitude de Movimento Articular , Tíbia/anatomia & histologia , Resultado do Tratamento
6.
J Mech Behav Biomed Mater ; 63: 399-406, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27454526

RESUMO

The in-vivo progression of creep and wear in ultra-high molecular weight polyethylene (UHMWPE) acetabular liners has been clinically evaluated by measuring radiographic penetration of femoral heads. In such clinical assessments, however, viscoelastic strain relaxation has been rarely considered after a removal of hip joint loading, potentially leading to an underestimation of the penetrated thickness. The objective of this study was to investigate shape-recovery behavior of pre-compressed, radiation crosslinked and antioxidant vitamin E-diffused UHMWPE acetabular liners, and also to characterize the effects of varying their internal diameter (ID) and wall thickness (WT). We applied uniaxial compression to the UHMWPE specimens of various ID (28, 32, 36mm) and WT (4.8, 6.8, 8.9mm) for 4320min under the constant load of 3000N, and subsequently monitored the strain-relaxation behavior as a function of time after unloading. It was observed that there was a considerable shape recovery of the components after removal of the external static load. Reducing ID and WT significantly accelerated the rate of creep strain recovery, and varying WT was more sensitive to the recovery behavior than ID. Creep deformation of the tested liners recovered mostly within the first 300min after unloading. Note that approximately half of the total recovery amount proceeded just within 5min after unloading. These results suggest a remarkably high capability of shape recovery of vitamin E-diffused highly crosslinked UHMWPE. In conclusion, the time-dependent shape recovering and the diameter-thickness effect on its behavior should be carefully considered when the postoperative penetration is quantified in highly crosslinked UHMWPE acetabular liners (especially on the non-weight bearing radiographs).


Assuntos
Prótese de Quadril , Teste de Materiais , Polietilenos/química , Desenho de Prótese , Vitamina E/química , Artroplastia de Quadril , Estresse Mecânico
7.
J Mech Behav Biomed Mater ; 62: 399-406, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27261923

RESUMO

Since the early 2000s, the use of large femoral heads is becoming increasingly popular in total hip arthroplasty (THA), which provides an improved range of motion and joint stability. Large femoral heads commonly necessitate to be coupled with thinner acetabular liners than the conventionally used because of the limited sizes of outer shells (especially for patients with small pelvic size). However, the influence of the liner thinning on the mechanical performance is still not clearly understood. The objective of this study was to experimentally clarify the size and thickness effect on the rates of compressive creep strain in conventional (virgin low-crosslinked) and vitamin E-diffused highly crosslinked, ultra-high molecular weight polyethylene (UHMWPE) acetabular liners. We applied uniaxial compression to these liners of various internal diameters (28, 32 and 36mm) and thicknesses (4.8, 6.8 and 8.9mm) up to 4320min under the constant load of 3000N. Vitamin E-diffused highly crosslinked UHMWPE components showed significantly greater creep resistance than the conventional ones. In the both types of UHMWPE, the rates of creep strain significantly decreased by increasing the internal diameter and thickness. Varying the component thickness contributed more largely to the creep behavior rather than the internal diameter. Our results suggest the positive mechanical advantage of using large femoral heads, but at the same time, a considerable liner thinning is not recommended for minimizing creep strain. Therefore, the further in-vitro as well as in-vivo research are necessary to conclude the optimal balance of head diameter and liner thickness within the limited sizes of outer shells.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Polietilenos/química , Desenho de Prótese , Vitamina E/química , Humanos , Falha de Prótese
8.
Ther Clin Risk Manag ; 11: 1383-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26396523

RESUMO

It has been recognized that perioperative hemostasis management after joint-replacement surgery for hemophilia patients is complicated and cumbersome, due to the necessity of rigorous monitoring for clotting-factor levels throughout the infusion. Between 2005 and 2014, we examined seven patients with hemophilia A (ten joints: six hips and four knees) receiving total hip or knee arthroplasty (THA or TKA) for hemophilic arthropathy. One male patient (31 years old) showed an intra-articular hematoma formation after THA (case 1). In another male patient (46 years old) receiving TKA, the postoperative trough factor VIII level became lower significantly than reference levels (80%-100% for the 5-10 postoperative days) recommended by the guidelines from the Japanese Society on Thrombosis and Hemostasis, despite sufficient coagulant based on the guidelines being administered (case 2). In the latter patient, deep infection and hematoma formation were observed postoperatively. In this article, we provide a detailed clinical report regarding these two complication cases at the early postoperative periods, and the management of bleeding control for hemophilia patients is discussed.

9.
J Mech Behav Biomed Mater ; 42: 43-53, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25460925

RESUMO

Plastic deformation is an unavoidable event in biomedical polymeric implants for load-bearing application during long-term in-vivo service life, which involves a mass transfer process, irreversible chain motion, and molecular reorganization. Deformation-induced microstructural alterations greatly affect mechanical properties and durability of implant devices. The present research focused on evaluating, from a molecular physics viewpoint, the impact of externally applied strain (or stress) in ultra-high molecular weight polyethylene (UHMWPE) prostheses, subjected to radiation cross-linking and subsequent remelting for application in total hip arthroplasty (THA). Two different types of commercial acetabular liners, which belong to the first-generation highly cross-linked UHMWPE (HXLPE), were investigated by means of confocal/polarized Raman microprobe spectroscopy. The amount of crystalline region and the spatial distribution of molecular chain orientation were quantitatively analyzed according to a combined theory including Raman selection rules for the polyethylene orthorhombic structure and the orientation distribution function (ODF) statistical approach. The structurally important finding was that pronounced recrystallization and molecular reorientation increasingly appeared in the near-surface regions of HXLPE liners with increasing the amount of plastic (compressive) deformation stored in the microstructure. Such molecular rearrangements, occurred in response to external strains, locally increase surface cross-shear (CS) stresses, which in turn trigger microscopic wear processes in HXLPE acetabular liners. Thus, on the basis of the results obtained at the molecular scale, we emphasize here the importance of minimizing the development of irrecoverable deformation strain in order to retain the pristine and intrinsically high wear performance of HXLPE components.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fenômenos Mecânicos , Polietilenos/química , Anisotropia , Teste de Materiais , Transição de Fase , Estresse Mecânico
10.
Biomed Res Int ; 2015: 610763, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26576428

RESUMO

The values of hip rotation center (HRC) and femoral offset (FO) evaluated according to Caucasian anatomical landmarks have been regarded as a useful reference also for Japanese patients in total hip arthroplasty (THA). In a strict sense, however, since there can be racial differences among their anatomical morphologies, it is clinically important to reconsider those parameters for the Japanese. In the present study, in order to investigate correlations among hip and pelvic morphometric parameters, frontal radiographs were taken from 98 Japanese adults (60 males and 38 females) without acetabular dysplasia and arthropathy in the standing position. Their mean age was 62.0 ± 16.7 years. The horizontal position of HRC was significantly correlated with the pelvic width in both genders (P = 0.0026 and 0.0010 for the males and the females, resp.). The vertical position of HRC was significantly correlated with the teardrop-sacroiliac distance in the males (P = 0.0003) and with the pelvic cavity height in the females (P = 0.0067). However, in both genders, there were no correlations among FO and the other parameters analyzed in this study. Our present findings might contribute to theoretical implications of an appropriate HRC position for Japanese OA patients in THA.


Assuntos
Pontos de Referência Anatômicos/diagnóstico por imagem , Artroplastia de Quadril/métodos , Fêmur/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Osteoartrite/diagnóstico por imagem , Osteoartrite/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/cirurgia , Articulação do Quadril/cirurgia , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Cuidados Pré-Operatórios/métodos , Prognóstico , Ajuste de Prótese/métodos , Radiografia , Reprodutibilidade dos Testes , Rotação , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto Jovem
11.
Biomed Res Int ; 2014: 808369, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25243183

RESUMO

The present study investigated effects of processing procedures on morphology of highly cross-linked and re-melted UHMWPE (XLPE) in total hip and knee arthroplasty (THA, TKA). The shape recovery behavior was also monitored via uniaxial compression test at room temperature after non-destructive characterizations of the in-depth microstructure by confocal/polarized Raman spectroscopy. The goal of this study was to relate the manufacturing-induced morphology to the in vivo micromechanical performance, and ultimately to explore an optimal structure in each alternative joint bearing. It was clearly confirmed that the investigated XLPE hip and knee implants, which were produced from different orthopaedic grade resins (GUR 1050 and GUR 1020), consisted of two structural regions in the as-received states: the near-surface transitional anisotropic layer (≈100 µm thickness) and the bulk isotropic structural region. These XLPEs exhibited a different crystalline anisotropy and molecular texture within the near-surface layers. In addition, the knee insert showed a slightly higher efficiency of shape recovery against the applied strain over the hip liner owing to a markedly higher percentage of the bulk amorphous phase with intermolecular cross-linking. The quantitative data presented in this study might contribute to construct manufacturing strategies for further rationalized structures as alternative bearings in THA and TKA.


Assuntos
Materiais Biocompatíveis/química , Prótese de Quadril , Prótese do Joelho , Teste de Materiais/métodos , Polietilenos/química , Anisotropia , Fenômenos Mecânicos , Análise Espectral Raman
12.
J Mech Behav Biomed Mater ; 36: 59-70, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24801101

RESUMO

Vitamin-E (α-tocopherol) is now recognized worldwide as one of the most promising antioxidant agents for highly cross-linked polyethylene (HXLPE) used in total joint replacements. In the contemporary manufacturing processes, two alternative methods are currently accepted to incorporate this antioxidant into polyethylene microstructure: (i) blending vitamin-E before consolidation and radiation crosslinking; (ii) infusing vitamin-E via a homogenizing heat treatment after radiation crosslinking. However, the effects of these technological differences on crystalline morphology and mechanical behavior of polyethylene remains to be fully elucidated. The aim of this paper is to quantitatively evaluate the microstructural differences of commercially available vitamin-E blended and infused HXLPE liner (referred to as Liner BL and IF, respectively). For this purpose, confocal/polarized Raman spectroscopy was used to systematically examine the three-phase percentages (amorphous (αa), crystalline (αc), and intermediate third phase (αt)), preferential molecular orientation (θp), and degree of crystalline anisotropy (〈P2(cosß)〉). Additionally, we compared the time-dependent deformation of Liner BL and IF as obtained by uniaxial stress relaxation tests followed by strain recovery. Distinctive features of the near-surface αc, θp, and〈P2(cosß)〉 were clearly observed within the first 35µm in the two studied liners. Despite the equivalent level of the bulk αc and 〈P2(cosß)〉, higher restoring force against a uniaxial strain was observed in Liner IF, which reflects a higher crosslink density in its amorphous phase. On the other hands, a higher degree of surface orientational randomness was detected in Liner BL, which is structurally more beneficial for minimizing the in-vivo occurrence of strain-softening-assisted wear.


Assuntos
Materiais Biocompatíveis/síntese química , Implantes de Medicamento/síntese química , Prótese de Quadril , Polietilenos/química , Vitamina E/administração & dosagem , Vitamina E/química , Antioxidantes/administração & dosagem , Reagentes de Ligações Cruzadas/química , Módulo de Elasticidade , Teste de Materiais , Conformação Molecular , Estresse Mecânico , Resistência à Tração , Viscosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA