RESUMO
BACKGROUND: Smoking worsens underlying asthma inflammation and also induces resistance to inhaled corticosteroids (ICS). Small airways dysfunction measured by impulse oscillometry (IOS) is associated with worse control. OBJECTIVES: We investigated the effects on small airways of adding long-acting beta-agonist (LABA) alone or with long-acting muscarinic antagonist (LAMA) to ICS in asthmatic smokers. METHODS: Sixteen current smokers were enrolled: mean age 44 year, FEV1 84%, FEF25-75 47%, R5 158%, ACQ 1.69, 20 pack year . Patients were converted to a reference ICS as HFA-BDP during initial run-in at median dose of 800 µg/day. Open label olodaterol 5 µg od (OLO) or olodaterol 5 µg/tiotropium 5 µg od (OLO/TIO) was added to HFA-BDP for median duration of 3 weeks in a randomized cross over design, including run-in and washout periods on HFA-BDP. IOS and spirometry were measured after each treatment (BDP/OLO/TIO or BDP/OLO) and at baseline after run-in and washout (BDP). RESULTS: After chronic dosing, IOS outcomes at trough except for R20 were all significantly improved with OLO/TIO compared to OLO. For the primary end-point of total airway resistance (as R5), the mean difference (95%CI) at trough was 0.06 (0.015-0.10) kPa/l/s, peripheral airways resistance (as R5-R20) 0.03 (0.003-0.06) kPa/l/s, peripheral lung reactance area (as AX) 0.38 (0.08-0.68) kPa/l and resonant frequency (as RF) 2.28 (0.45-4.12) Hz. FEF25-75 at trough was also better with OLO/TIO vs TIO: 0.93 (0.86 - 0.95) l/s while FEV1 was not different. CONCLUSIONS: ICS/LABA/LAMA was superior to ICS/LABA on trough small airway outcomes in asthma patients who smoke.
Assuntos
Corticosteroides/administração & dosagem , Agonistas de Receptores Adrenérgicos beta 2/administração & dosagem , Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Benzoxazinas/administração & dosagem , Pulmão/efeitos dos fármacos , Antagonistas Muscarínicos/administração & dosagem , Fumantes , Fumar/efeitos adversos , Brometo de Tiotrópio/administração & dosagem , Administração por Inalação , Corticosteroides/efeitos adversos , Agonistas de Receptores Adrenérgicos beta 2/efeitos adversos , Adulto , Antiasmáticos/efeitos adversos , Asma/diagnóstico , Asma/fisiopatologia , Benzoxazinas/efeitos adversos , Estudos Cross-Over , Combinação de Medicamentos , Feminino , Humanos , Pulmão/fisiopatologia , Masculino , Antagonistas Muscarínicos/efeitos adversos , Nebulizadores e Vaporizadores , Recuperação de Função Fisiológica , Escócia , Fumar/fisiopatologia , Fatores de Tempo , Brometo de Tiotrópio/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: Extra-fine particle formulations of inhaled corticosteroid (ICS) are associated with improved lung delivery. OBJECTIVES: A pragmatic study to assess patient-reported outcomes after switching from fine to extra-fine particle ICS in persistent asthma. METHODS: Twenty-four patients (mean age 48 year, FEV1 84%, ACQ 1.67) received 4 weeks run-in with a constant dose of fine particle ICS (mean dose 710 µg), followed by switching to an equivalent dose of extra-fine particle hydrofluoroalkane beclomethasone dipropionate (mean dose 355µg). Asthma control questionnaire (ACQ), the primary outcome and mini asthma quality of life questionnaire (mAQLQ) were measured pre- and post-run-in (baseline) and after 4 weeks and 8 weeks of switching. RESULTS: Comparing pre- vs post-run-in, there were no differences for ACQ: 1.67 vs 1.65 or AQLQ: 5.08 vs 5.34. There were mean (95%CI) improvements (P < 0.001) from baseline after 8 weeks for ACQ: -0.53 (-0.83, -0.23) and AQLQ: 0.69 (0.35, 1.04), which exceeded the minimal clinically important difference (MCID) of 0.5 for both. There were also differences (P < 0.05) in domiciliary symptoms and reliever use. There were no significant changes at 8 weeks in lung function, FeNO or blood eosinophils. CONCLUSIONS: Pragmatic switching from fine to extra-fine particle ICS at half the dose was associated with clinically relevant improvements in asthma control and quality of life, but not lung function or type 2 biomarkers.
Assuntos
Corticosteroides/administração & dosagem , Asma/tratamento farmacológico , Qualidade de Vida , Inquéritos e Questionários , Administração por Inalação , Adolescente , Corticosteroides/efeitos adversos , Adulto , Idoso , Asma/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho da PartículaRESUMO
BACKGROUND: The forced oscillation technique (FOT) measures respiratory impedance during normal tidal breathing and requires minimal patient cooperation. OBJECTIVE: To compare IOS and AOS devices in patients with asthma and COPD. METHODS: We compared two different FOT devices, namely impulse oscillometry using a loudspeaker (IOS: Jaeger Masterscreen) and airwave oscillometry using a vibrating mesh (AOS: Thorasys Tremoflo) for pre- and post-bronchodilator measurements in 84 patients with asthma and COPD. RESULTS: The overall pattern of measurement bias was for higher resistance with IOS and higher reactance with AOS, this being the case in asthma and COPD separately. There were small but significantly higher values using IOS for resistance at 5 Hz (R5) and 20(19) Hz (R20(19)). In converse, values for reactance at 5 Hz (X5), reactance area (AX) and resonant frequency (Fres) were significantly higher using AOS but to a much larger extent. The difference in AX between devices was more pronounced in COPD than in asthma. Salbutamol reversibility as % change was greater in asthma than COPD patients with AX but not FEV1. CONCLUSION: Our study showed evidence of better agreement for resistance than reactance when comparing IOS and AOS, perhaps inferring that AOS may be more sensitive at measuring reactance in patients with airflow obstruction.