Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Ophthalmic Physiol Opt ; 44(4): 757-768, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38240175

RESUMO

PURPOSE: To assess the impact of 3 months of orthokeratology (ortho-k) contact lenses (CLs) for myopia correction on the corneoscleral profile, as changes in scleral geometry could serve as indirect evidence of alteration in the corneal biomechanical properties. METHODS: Twenty subjects (40 eyes) were recruited to wear ortho-k lenses overnight; however, after discontinuation (two CL fractures, one under-correction and two non-serious adverse events), 16 subjects (31 eyes) finished a 3-month follow-up. Corneoscleral topographies were acquired using the Eye Surface Profiler (ESP) system before and after 3 months of lens wear. Steep (SimKs) and flat (SimKf) simulated keratometry and scleral sagittal height measurements for 13-, 14- and 15-mm chord lengths were automatically calculated by the ESP software. Additionally, sagittal height and slope were calculated in polar format from 21 radii (0-10 mm from the corneal apex) at 12 angles (0-330°). Linear mixed models were fitted to determine the differences between visits. RESULTS: SimKs and SimKf were increased significantly (p ≤ 0.02). The sagittal height in polar format increased significantly (p = 0.046) at a radius of 2.5 mm for 150°, 180°, 210° and 240° orientations and at a radius of 3.0 mm for 210°. Additionally, the slope in polar format significantly decreased (p ≤ 0.04) at radii ranges of 0.0-0.5, 0.5-1.0 and 1.0-1.5 mm for multiple angles and at a radii range of 5.0-5.5 mm for 90°. It also increased significantly (p ≤ 0.045) at a radii range of 1.5-2.0 mm for 30° and at radii ranges of 2.0-2.5, 2.5-3.0 and 3.0-3.5 mm for multiple angles. No significant changes were found for any parameter measured from the scleral area. CONCLUSIONS: Three months of overnight ortho-k lens wear changed the central and mid-peripheral corneal geometry as expected, maintaining the peripheral cornea and the surrounding sclera stability.


Assuntos
Córnea , Topografia da Córnea , Miopia , Procedimentos Ortoceratológicos , Refração Ocular , Esclera , Humanos , Procedimentos Ortoceratológicos/métodos , Masculino , Feminino , Miopia/fisiopatologia , Miopia/terapia , Córnea/diagnóstico por imagem , Adulto Jovem , Refração Ocular/fisiologia , Lentes de Contato , Adolescente , Adulto , Seguimentos , Acuidade Visual/fisiologia , Fenômenos Biomecânicos
2.
Ophthalmic Physiol Opt ; 44(1): 124-130, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37974449

RESUMO

PURPOSE: To assess the reliability and agreement of non-invasive break-up time (NIBUT) in symptomatic and asymptomatic contact lens (CL) wearers using automatic objective and conventional subjective techniques. METHODS: In this prospective cross-sectional study, soft CL wearers, classified into symptomatic and asymptomatic based on the Contact Lens Dry Eye Questionnaire-8, underwent NIBUT assessment with the CL in situ. The CA-800 Corneal Analyzer and the EasyTear® VIEW+ Tearscope were used for objective and subjective evaluation, respectively. The within-subject repeatability and intraclass correlation coefficient (ICC) were calculated. The agreement between the devices was compared using the Bland-Altman method. RESULTS: A total of 141 CL wearers (51 male and 90 female) with a mean age of 33.6 (SD = 12.2) years were included. The repeatability and ICC values obtained with the CA-800 device when measuring NIBUT were 5.4 s and 58.6% across the whole sample, 4.2 s and 48.8% for the asymptomatic group and 7.1 s and 68.4% for the symptomatic group. When using the subjective method (EasyTear®), the respective repeatability and ICC values were 7.3 s and 32.7% for the whole sample, 6.5 s and 30.4% for the asymptomatic group and 8.6 s and 35.9% for the symptomatic group. The CA-800 device provided significantly (p < 0.001) shorter NIBUT values compared with EasyTear® for the whole sample (3.3 [2.9] vs. 8.1 [3.4] s), the asymptomatic (3.3 [3.0] vs. 7.7 [3.6] s) and the symptomatic (3.8 [2.9] vs. 8.6 [3.0] s) groups. CONCLUSION: Objective (CA-800) NIBUT assessment provides more reliable measurements than the conventional subjective technique using the EasyTear® device. However, CL practitioners should also be aware that the objective method indicates shorter NIBUT values. Symptomatic CL wearers may also need a higher number of NIBUT measurements to obtain reliable estimations.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Humanos , Masculino , Feminino , Adulto , Estudos Prospectivos , Reprodutibilidade dos Testes , Estudos Transversais , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Lágrimas
3.
Eye Contact Lens ; 50(1): 29-34, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38124284

RESUMO

OBJECTIVE: The purpose of this study was to assess the visual performance and monochromatic higher-order aberrations (HOAs) obtained while wearing a MiSight dual-focus (DF) contact lenses (CL) in comparison with a single-vision contact lens (SVCL). METHODS: A randomized, double-masked, cross-over study was performed. Participants were fitted with a DFCL and a SVCL composed of the same material (omafilcon A) and parameters. Logarithm of the Minimum Angle of Resolution high-contrast (100%) and low-contrast (10%) visual acuity (VA) and contrast sensitivity (CS) for 3, 6, 12, and 18 cycles per degree were measured. Higher-order aberrations were also evaluated using a Hartmann-Shack aberrometer with the CLs on. RESULTS: Twenty-four subjects (21 females and 3 males) with a mean age of 21.9±1.9 years (range: 18-27) were included. Low-contrast VA was significantly lower with the DFCL regarding the SVCL design (0.39±0.23 vs 0.25±0.18, P=0.002). However, there were no differences in high-contrast VA between both CLs (-0.03±0.10 vs -0.09±0.14, P=0.187). Contrast sensitivity was lower with the DFCL under all spatial frequencies (P≤0.048). Second-, third-, fourth-, and fifth-order aberrations were significantly (P<0.001) higher for the DFCL. There were also significant differences between DFCL and SVCL in defocus (0.87±0.28 vs 0.16±0.35, P<0.001), oblique trefoil (-0.16±0.27 vs -0.01±0.08, P=0.005), vertical coma (0.13±0.17 vs 0.00±0.08, P=0.002), and spherical aberration (0.09±0.11 vs -0.02±0.05, P=0.002). CONCLUSION: Visual performance for detecting low-contrast targets is reduced when wearing MiSight DFCL compared with a SVCL with the same material. The main reason might be the induction of second-order and HOAs by the DFCL design.


Assuntos
Lentes de Contato Hidrofílicas , Lentes de Contato , Adulto , Feminino , Humanos , Masculino , Adulto Jovem , Sensibilidades de Contraste , Estudos Cross-Over , Transtornos da Visão , Acuidade Visual , Adolescente
4.
Graefes Arch Clin Exp Ophthalmol ; 261(10): 2853-2861, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37115266

RESUMO

PURPOSE: To assess the relationship between anterior chamber depth (ACD) and lens thickness (LT), as well as its three main components (anterior and posterior cortex and nucleus thickness), in cataractous and non-cataractous eyes, depending on the axial length (AxL). METHODS: Anterior and posterior cortex and nucleus thickness of the crystalline lens, ACD, and AxL were measured using optical low-coherence reflectometry in cataractous and non-cataractous eyes. They were also classified into hyperopia, emmetropia, myopia, and high myopia, depending on AxL; thus, eight subgroups were created. A minimum sample size of 44 eyes (of 44 patients) for each group was recruited. Linear models were fitted for the whole sample and each AxL subgroup to assess if there were differences in the relationships between the crystalline lens variables and ACD, including age as a covariate. RESULTS: Three hundred seventy cataract patients (237 females, 133 males) and 250 non-cataract controls (180 females, 70 males), aged 70.5 ± 9.4 and 41.9 ± 15.5 years, respectively, were recruited. The mean AxL, ACD, and LT for the cataractous and non-cataractous eyes were 23.90 ± 2.05, 24.11 ± 2.11, 2.64 ± 0.45, and 2.91 ± 0.49, 4.51 ± 0.38, 3.93 ± 0.44 mm, respectively. The inverse relationship of LT, anterior and posterior cortex, and nucleus thickness with ACD was not significantly (p ≥ 0.26) different between cataractous and non-cataractous eyes. Further subclassification of the sample depending on AxL showed that the inverse relationship between the posterior cortex and ACD was no longer significant (p > 0.05) for any non-cataractous AxL group. LT, anterior and posterior cortex, and nucleus thickness was not significantly (p ≥ 0.43) different between cataractous and non-cataractous eyes for the whole sample, and all AxL groups after adjusting for age. CONCLUSIONS: The presence of cataracts does not modify the inverse relationship of the LT, anterior and posterior cortex, and nucleus with ACD. And this relationship does not seem to depend importantly on AxL. Besides, the possible differences in LT, anterior and posterior cortex, and nucleus between cataractous and non-cataractous eyes may not be caused by lens opacification, but possibly by the progressive lens growth due to aging.


Assuntos
Catarata , Cristalino , Miopia , Masculino , Feminino , Humanos , Catarata/diagnóstico , Envelhecimento , Câmara Anterior , Biometria
5.
Int Ophthalmol ; 43(5): 1501-1510, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36260197

RESUMO

PURPOSE: To assess whether the postoperative outcomes of the implantation of an EVO + implantable collamer lens (ICL) in one eye can be used as a predictor of the vault of the fellow eye, and to evaluate the vault changes of the implantation in both eyes during the postoperative period. METHODS: A prospective study including 40 eyes of 20 patients with a bilateral EVO + ICL implantation was performed. Subjects were evaluated before the surgery and 1 day, 1 week and 1, 3 and 6 months postoperatively. Central vault was assessed using spectral-domain optical coherence tomography. The inter-eye and follow-up analyses were performed using lineal models and the Bland-Altman method. RESULTS: The vault of the first implanted eye at the 1-day visit highly predicts the vault of the second eye (R2 = .87; P < .001); the mean inter-eye difference was - 0.95 µm, and the superior and inferior limits of agreement were -50.27 µm and 148.37 µm, respectively. This relationship was maintained during the medium-term follow-up, not finding differences in the slopes among visits (P ≥ .09). A progressive decrease of vault was found during the follow-up (P < .001). Larger vault change 6 months after the surgery was associated with higher vault 1 day after the ICL implantation (R2 = .19;P = .005). CONCLUSION: One-day postoperative vault in the first eye can help to predict the optimal ICL sizing in the second eye. Vault tends to decrease during the first 6 months after EVO + ICL implantation. Eyes with higher initial vaults will also show larger reductions during the medium-term follow-up.


Assuntos
Miopia , Lentes Intraoculares Fácicas , Humanos , Implante de Lente Intraocular/métodos , Estudos Prospectivos , Miopia/diagnóstico , Miopia/cirurgia , Período Pós-Operatório , Estudos Retrospectivos
6.
Int Ophthalmol ; 43(12): 4711-4718, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37697080

RESUMO

PURPOSE: To evaluate the effect of EVO+ Visian Implantable Collamer Lens (ICL) implantation on the iridocorneal angle pigmentation and structures. METHODS: Myopic refractive surgery candidates who underwent posterior chamber EVO+ ICL implantation were evaluated preoperatively and 3 and 6 months postoperatively. High-resolution images of the iridocorneal angle (nasal, superior, temporal and inferior quadrants) were acquired during gonioscopy. A masked observer, blinded to study visits and patients' information, evaluated the angle width, apparent iris root insertion, iris configuration, and trabecular meshwork pigmentation according to the Spaeth scale in two different occasions. The intra-rater reliability was estimated using the weighted Gwet's Agreement Coefficient (AC2). Differences between visits were analyzed using the Cochran Q test or the Friedman test. RESULTS: Twenty-one patients (13 females and 8 males) aging 31.3 ± 6.3 years old were recruited. The intra-rater reliability of gonioscopy assessment was excellent for every parameter assessed (AC2 ≥ 0.97). No significant differences were found among the study visits for any quadrant in the angle width (p ≥ 0.74), apparent iris root insertion (p ≥ 0.22), iris configuration (p ≥ 0.21) and trabecular meshwork pigmentation (p ≥ 0.24). Mean pigmentation of trabecular meshwork for the four quadrants did not vary either among visits (p = 0.25). CONCLUSIONS: The EVO+ ICL implantation after uneventful procedures appears not to clinically affect the iridocorneal angle pigmentation and/or structures during a short-medium follow-up using gonioscopy assessment. The intra-rater reliability of glaucoma specialists assessing iridocorneal angle structures using gonioscopy images is very high.


Assuntos
Implante de Lente Intraocular , Transtornos da Pigmentação , Masculino , Feminino , Humanos , Adulto , Reprodutibilidade dos Testes , Implante de Lente Intraocular/métodos , Câmara Anterior , Malha Trabecular/cirurgia , Iris/cirurgia , Pigmentação , Gonioscopia
7.
AIDS Care ; 33(10): 1340-1349, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33487029

RESUMO

We evaluated health-related quality of life (QoL) and self-reported incomplete adherence as predictors of early second-line antiretroviral (ART) virological failure (VF). ACTG A5273 study participants completed the ACTG SF-21 measure which has 8 QoL domains. We used exact logistic regression to assess the association of QoL at baseline and week 4 with early VF adjusted for self-reported adherence. Of 500 individuals (51% women, median age 39 years) in this analysis, 79% and 75% self-reported complete adherence (no missing doses in the past month) at weeks 4 and 24, respectively. Early VF was experienced by 7% and more common among those who self-reported incomplete adherence. Participants with low week 4 QoL scores had higher rates of early VF than participants with high scores. After adjusting for self-reported adherence at week 4, VL and CD4 at baseline, cognitive functioning, pain and mental health domains were significantly associated with subsequent early VF. In this post-hoc analysis, poorer QoL adds to self-reported incomplete adherence after 4 weeks of second-line ART in predicting VF at week 24. Evaluation is needed to assess whether individuals with poorer QoL might be targeted for greater support to reduce risk of VF.Trial registration: ClinicalTrials.gov identifier: NCT01352715.


Assuntos
Fármacos Anti-HIV , Infecções por HIV , Adulto , Fármacos Anti-HIV/uso terapêutico , Antirretrovirais/uso terapêutico , Feminino , Infecções por HIV/tratamento farmacológico , Humanos , Masculino , Adesão à Medicação , Qualidade de Vida , Autorrelato , Carga Viral
8.
J Infect Dis ; 222(5): 777-786, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32274499

RESUMO

BACKGROUND: During antiretroviral treatment (ART) with plasma HIV RNA below the limit of quantification, HIV RNA can be detected in genital or rectal secretions, termed discordant shedding (DS). We hypothesized that proliferating cells produce virions without HIV replication. METHODS: ART-naive Peruvians initiating ART were observed for DS over 2 years. HIV env and pol genomes were amplified from DS. Antiretrovirals and cytokines/chemokines concentrations were compared at DS and control time points. RESULTS: Eighty-two participants had ART suppression. DS was detected in 24/82 (29%) participants: 13/253 (5%) cervicovaginal lavages, 20/322 (6%) seminal plasmas, and 6/85 (7%) rectal secretions. HIV RNA in DS specimens was near the limit of quantification and not reproducible. HIV DNA was detected in 6/13 (46%) DS cervicovaginal lavages at low levels. Following DNase treatment, 5/39 DS specimens yielded HIV sequences, all without increased genetic distances. Women with and without DS had similar plasma antiretroviral levels and DS in 1 woman was associated with inflammation. CONCLUSIONS: HIV RNA and DNA sequences and therapeutic antiretroviral plasma levels did not support HIV replication as the cause of DS from the genital tract. Rather, our findings infer that HIV RNA is shed due to proliferation of infected cells with virion production.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Secreções Corporais/virologia , DNA Viral/análise , Infecções por HIV/tratamento farmacológico , HIV-1/fisiologia , RNA Viral/análise , Eliminação de Partículas Virais , Adulto , Fármacos Anti-HIV/sangue , Colo do Útero/virologia , Citocinas/sangue , Feminino , Genes env , Genes pol , HIV-1/genética , Humanos , Masculino , Estudos Prospectivos , RNA Viral/sangue , Reto/virologia , Sêmen/virologia , Análise de Sequência de DNA , Análise de Sequência de RNA , Irrigação Terapêutica , Vagina/virologia , Carga Viral , Replicação Viral/efeitos dos fármacos , Adulto Jovem
9.
Clin Infect Dis ; 71(1): 158-165, 2020 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-31630166

RESUMO

BACKGROUND: Distal sensory peripheral neuropathy (DSPN) is a complication of human immunodeficiency virus (HIV). We estimate DSPN prevalence in 7 resource-limited settings (RLSs) for combination antiretroviral therapy (cART)-naive people living with HIV (PLWH) compared with matched participants not living with HIV and in PLWH virally suppressed on 1 of 3 cART regimens. METHODS: PLWH with a CD4+ count <300 cells/mm3 underwent standardized neurological examination and functional status assessments before and every 24 weeks after starting cART. Matched individuals not living with HIV underwent the same examinations once.Associations between covariates with DSPN at entry were assessed using the χ2 test, and virally suppressed PLWH were assessed using generalized estimating equations. RESULTS: Before initiating cART, 21.3% of PLWH had DSPN compared with 8.5% of people not living with HIV (n = 2400; χ2(df = 1) = 96.5; P < .00001). PLWH with DSPN were more likely to report inability to work [χ2(df = 1) = 10.6; P = .001] and depression [χ2(df = 1) = 8.9; P = .003] than PLWH without DSPN. Overall prevalence of DSPN among those virally suppressed on cART decreased: 20.3%, week 48; 15.3%, week 144; and 10.3%, week 192. Incident DSPN was seen in 127 PLWH. Longitudinally, DSPN was more likely in older individuals (P < .001) and PLWH with less education (P = .03). There was no significant association between cART regimen and DSPN. CONCLUSIONS: Although the prevalence of DSPN decreased following cART initiation in PLWH, further research could identify strategies to prevent or ameliorate residual DSPN after initiating cART in RLSs.


Assuntos
Infecções por HIV , Soropositividade para HIV , HIV-1 , Doenças do Sistema Nervoso Periférico , Idoso , Contagem de Linfócito CD4 , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Humanos , Doenças do Sistema Nervoso Periférico/epidemiologia
10.
Clin Infect Dis ; 68(10): 1739-1746, 2019 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-30137250

RESUMO

BACKGROUND: AIDS Clinical Trial Group 5199 compared neurological and neuropsychological test performance of human immunodeficiency virus type 1 (HIV-1)-infected participants in resource-limited settings treated with 3 World Health Organization-recommended antiretroviral (ART) regimens. We investigated the impact of tuberculosis (TB) on neurological and neuropsychological outcomes. METHODS: Standardized neurological and neuropsychological examinations were administered every 24 weeks. Generalized estimating equation models assessed the association between TB and neurological/neuropsychological performance. RESULTS: Characteristics of the 860 participants at baseline were as follows: 53% female, 49% African; median age, 34 years; CD4 count, 173 cells/µL; and plasma HIV-1 RNA, 5.0 log copies/mL. At baseline, there were 36 cases of pulmonary, 9 cases of extrapulmonary, and 1 case of central nervous system (CNS) TB. Over the 192 weeks of follow-up, there were 55 observations of pulmonary TB in 52 persons, 26 observations of extrapulmonary TB in 25 persons, and 3 observations of CNS TB in 2 persons. Prevalence of TB decreased with ART initiation and follow-up. Those with TB coinfection had significantly poorer performance on grooved pegboard (P < .001) and fingertapping nondominant hand (P < .01). TB was associated with diffuse CNS disease (P < .05). Furthermore, those with TB had 9.27 times (P < .001) higher odds of reporting decreased quality of life, and had 8.02 times (P = .0005) higher odds of loss of productivity. CONCLUSIONS: TB coinfection was associated with poorer neuropsychological functioning, particularly the fine motor skills, and had a substantial impact on functional ability and quality of life. CLINICAL TRIALS REGISTRATION: NCT00096824.


Assuntos
Disfunção Cognitiva/diagnóstico , Coinfecção/complicações , Infecções por HIV/complicações , Recursos em Saúde/provisão & distribuição , Doenças do Sistema Nervoso/diagnóstico , Tuberculose/complicações , Adulto , Disfunção Cognitiva/microbiologia , Disfunção Cognitiva/virologia , Coinfecção/microbiologia , Coinfecção/virologia , Feminino , HIV-1 , Humanos , Internacionalidade , Estudos Longitudinais , Masculino , Destreza Motora , Doenças do Sistema Nervoso/microbiologia , Doenças do Sistema Nervoso/virologia , Testes Neuropsicológicos , Estudos Prospectivos , Qualidade de Vida , Tuberculose/virologia
11.
Clin Infect Dis ; 68(10): 1733-1738, 2019 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-30219843

RESUMO

BACKGROUND: Neurocognitive impairment remains a common complication of human immunodeficiency virus (HIV) despite effective antiretroviral therapy (ART). We previously reported improved neurocognitive functioning with ART initiation in 7 resource-limited countries for HIV+ participants from the AIDS Clinical Trials Group (ACTG) 5199 International Neurological Study (INS). Here, we apply normative data from the International Neurocognitive Normative Study (INNS) to INS to provide previously unknown rates of neurocognitive impairment. METHODS: The A5199 INS assessed neurocognitive and neurological performance within a randomized clinical trial with 3 arms containing World Health Organization first-line recommended ART regimens (ACTG 5175; PEARLS). The ACTG 5271 INNS collected normative comparison data on 2400 high-risk HIV-negative participants from 10 voluntary counseling and testing sites aligned with INS. Normative comparison data were used to create impairment ratings for HIV+ participants in INS; associations were estimated using generalized estimating equations. RESULTS: Among 860 HIV+ adults enrolled in ACTG 5199, 55% had no neurocognitive impairment at baseline. Mild neurocognitive impairment was found in 25%, moderate in 17%, and severe in 3% of participants. With the initiation of ART, the estimated odds of impairment were reduced 12% (95% confidence interval, 9%, 14%) for every 24 weeks (P < .0001) on ART. Mild impairment dropped slightly and then remained at about 18% out to week 168. CONCLUSIONS: Almost half of HIV+ participants had neurocognitive impairment at baseline before ART, based on local norms. With ART initiation, there were significant overall reductions in neurocognitive impairment over time, especially in those with moderate and severe impairments. CLINICAL TRIALS REGISTRATION: NCT00096824.


Assuntos
Infecções por HIV/complicações , Recursos em Saúde , Transtornos Neurocognitivos/epidemiologia , Transtornos Neurocognitivos/virologia , Adulto , Fármacos Anti-HIV/uso terapêutico , Terapia Antirretroviral de Alta Atividade , Feminino , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Humanos , Internacionalidade , Estudos Longitudinais , Masculino , Transtornos Neurocognitivos/classificação , Testes Neuropsicológicos , Prevalência , Estudos Prospectivos , Carga Viral
12.
Ophthalmic Physiol Opt ; 39(5): 328-336, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31463969

RESUMO

PURPOSE: To investigate the effect of soft contact lens (CL) wear on the morphology of the epithelial-lamina propria junction as well as the possible association with symptoms of discomfort. METHODS: Ninety-two subjects were recruited, including 60 soft CL wearers, 16 previous wearers, and 16 non-wearers. Additionally, subjects were classified as symptomatic or asymptomatic using the Contact Lens Dry Eye Questionnaire 8 for the CL wearers (a score ≥ 12 was considered symptomatic) and the Dry Eye Questionnaire 5 for the previous wearers and non-wearers (a score ≥ 5 was considered symptomatic). In vivo confocal microscopy of the tarsal conjunctiva was performed on a single occasion. Papillae density, shortest diameter, longest diameter, area, circularity, lumen/wall brightness ratio, irregularity, reflectivity, inhomogeneous appearance of wall and inhomogeneous appearance of rete ridges were evaluated. Effects of CL wear, symptoms and their interaction were analysed using two-way analysis of variance. Correlations were investigated using Spearman's coefficient. Data are presented as mean (standard deviation) or median [interquartile range]. RESULTS: Contact lens wearers, compared to previous wearers and non-wearers, showed higher circularity [0.65 (0.08) vs 0.59 (0.10) vs 0.57 (0.11), p = 0.003]. Subjects with symptoms, compared to asymptomatic participants, showed higher circularity [0.64 (0.08) vs 0.61 (0.10), p < 0.001] and lower irregularity (1.0 [0.7-2.0] vs 1.3 [1.0-2.3], p = 0.009). For previous wearers, those with symptoms showed greater density (135.4 [107.3-183.3] vs 87.5 [85.4-116.7], p = 0.013) and circularity [0.64 (0.07) vs 0.54 (0.10), p = 0.016]. For non-wearers, those with symptoms showed higher circularity [0.65 (0.08) vs 0.50 (0.08), p < 0.001]. DEQ-5 correlated with circularity (ρ = 0.55, p = 0.001). CONCLUSIONS: Soft CL wear modifies papillae of the epithelial-lamina propria junction into a more rounded shape; however, CL cessation appears to resolve this alteration. Additionally, a more rounded papillae shape is associated with ocular symptoms in subjects not actively wearing CLs.


Assuntos
Túnica Conjuntiva/patologia , Lentes de Contato Hidrofílicas/efeitos adversos , Síndromes do Olho Seco/diagnóstico , Adulto , Análise de Variância , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Microscopia Confocal , Adulto Jovem
13.
BMC Med ; 16(1): 161, 2018 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-30244671

RESUMO

BACKGROUND: Various individual biomarkers of inflammation and micronutrient status, often correlated with each other, are associated with adverse treatment outcomes in human immunodeficiency virus (HIV)-infected adults. The objective of this study was to conduct exploratory factor analysis (EFA) on multiple inflammation and micronutrient biomarkers to identify biomarker groupings (factors) and determine their association with HIV clinical treatment failure (CTF) and incident active tuberculosis (TB). METHODS: Within a multicountry randomized trial of antiretroviral therapy (ART) efficacy (PEARLS) among HIV-infected adults, we nested a case-control study (n = 290; 124 cases, 166 controls) to identify underlying factors, based on EFA of 23 baseline (pre-ART) biomarkers of inflammation and micronutrient status. The EFA biomarker groupings results were used in Cox proportional hazards models to study the association with CTF (primary analysis where cases were incident World Health Organization stage 3, 4 or death by 96 weeks of ART) or incident active TB (secondary analysis). RESULTS: In the primary analysis, based on eigenvalues> 1 in the EFA, three factors were extracted: (1) carotenoids), (2) other nutrients, and (3) inflammation. In multivariable-adjusted models, there was an increased hazard of CTF (adjusted hazard ratio (aHR) 1.47, 95% confidence interval (CI)1.17-1.84) per unit increase of inflammation factor score. In the secondary incident active TB case-control analysis, higher scores of the high carotenoids and low interleukin-18 factor was protective against incident active TB (aHR 0.48, 95% CI 0.26-0.87). CONCLUSION: Factors identified through EFA were associated with adverse outcomes in HIV-infected individuals. Strategies focused on reducing adverse HIV outcomes through therapeutic interventions that target the underlying factor (e.g., inflammation) rather than focusing on an individual observed biomarker might be more effective and warrant further investigation.


Assuntos
Biomarcadores/sangue , Infecções por HIV , Inflamação/sangue , Micronutrientes/sangue , Tuberculose/complicações , Adulto , Fármacos Anti-HIV/uso terapêutico , Terapia Antirretroviral de Alta Atividade/métodos , Estudos de Casos e Controles , Feminino , Infecções por HIV/sangue , Infecções por HIV/complicações , Infecções por HIV/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Oligoelementos/sangue , Falha de Tratamento , Tuberculose/tratamento farmacológico , Adulto Jovem
14.
AIDS Care ; 30(8): 954-962, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29343078

RESUMO

We evaluated health-related quality of life (QoL) in HIV infection participants with virologic failure (VF) on first-line antiretroviral therapy (ART) in 9 resource-limited settings (RLS). ACTG SF-21 was completed by 512 participants at A5273 study entry; 8 domains assessed: general health perceptions (GHP), physical functioning (PF), role functioning (RF), social functioning (SF), cognitive functioning (CF), pain (P), mental health (MH), and energy/fatigue (E/F); each was scored between 0 (worst) to 100 (best). Mean QoL scores ranged from 67 (GHP) to 91 (PF, SF, CF). QoL varied by country; high VL and low CD4 were associated with worse QoL in most domains, except RF (VL only), SF (CD4 only) and CF (neither). Number of comorbidities, BMI and history of AIDS were associated with some domains. Relationships between QoL and VL varied among countries for all domains. The association of worse disease status with worse QoL may reflect low QoL when ART was initiated and/or deterioration associated with VF.


Assuntos
Fármacos Anti-HIV/uso terapêutico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/psicologia , Qualidade de Vida/psicologia , Adulto , Feminino , Infecções por HIV/virologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Carga Viral
15.
Eye Contact Lens ; 44 Suppl 2: S227-S232, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29461299

RESUMO

OBJECTIVES: To determine the reliability of wet and modified dry blotting techniques used in the gravimetric method to assess contact lens (CL) water content (WC), the accuracy of both techniques in comparison with the nominal WC, and also their agreement. METHODS: We evaluated hydrated and dry CL mass values and WC using the gravimetric method in 440 daily disposable CLs. Samples assessed corresponded to Dailies Total 1, Dailies AquaComfort Plus, 1-Day Acuvue TruEye, and Biotrue ONEday. Back vertex power ranged from +3.00 diopters (D) to -6.00 D. Within-subject coefficient of variation (CVw) and intraclass correlation coefficients were calculated. Bland-Altman analysis was also performed. RESULTS: The modified dry blotting technique yielded significantly (P≤0.0001) higher hydrated CL mass values. The wet blotting technique provided significantly (P≤0.04) better consistency than the modified dry one. Values of CVw for wet and modified dry blotting techniques ranged from 1.2% to 2.1% and from 3.7% to 5.4%, respectively. As for dry CL mass values, CVw values were not significantly different (P≥0.05) between wet (range: 1.1%-1.9%) and dry (range: 1.0%-5.1%) blotting techniques, except for Dailies AquaComfort Plus (P=0.03). Bland-Altman analysis showed poor agreement between the techniques. The wet blotting technique yielded WC values close (around 1%) to nominal ones, in contrast to modified dry blotting technique (≥2.5%). CONCLUSIONS: The wet blotting technique is not only more reliable than the modified dry one when obtaining hydrated CL mass but also provides more accurate nominal WC measurements. Agreement between the techniques was poor.


Assuntos
Lentes de Contato Hidrofílicas , Teste de Materiais/métodos , Água/análise , Equipamentos Descartáveis , Humanos , Reprodutibilidade dos Testes
16.
Ophthalmic Physiol Opt ; 37(1): 60-70, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-28030882

RESUMO

PURPOSE: To assess the influence of different indoor environments simulated in an environmental chamber on soft contact lens (CL) wearers. METHODS: Fifty-four CL wearers were grouped based on their symptoms while wearing their CLs. Subjects were fitted with two different CL types, conventional hydrogel (Omafilcon A) and silicone hydrogel (comfilcon A), and exposed to two controlled indoor environmental conditions, standard [50% relative humidity (RH), 23°C, 930 mb of atmospheric pressure] and adverse (in-flight air cabin environment: 5% RH, localised air flow, 23°C, 750 mb atmospheric pressure), for 90 min in an environmental chamber, making a total of four visits. Symptoms, tear osmolarity, pre-lens tear breakup time (PLBUT), phenol red thread test, visual acuity, bulbar and limbal hyperaemia, corneal and limbal staining, and CL dehydration were assessed using repeated measures analysis of variance. A linear mixed model was used to analyse the effect of environment, CL type, discomfort-based grouping, and time on blink rate. RESULTS: Environment was found to significantly (p ≤ 0.018) affect limbal and bulbar hyperaemia, PLBUT, tear osmolarity, and CL dehydration. Likewise, CL type significantly (p ≤ 0.04) affected nasal and total corneal staining, limbal conjunctival staining, CL dehydration, comfort, and blurred vision. The environment, CL type, and time had significant effects (p ≤ 0.0001) on the blink rate. CONCLUSIONS: Ocular surface integrity and blink rate in CL wearers depend on the environment CL users are exposed to, as well as on the soft CL type that they are wearing. Tight control of environmental conditions can contribute to a better understanding of CL-related discomfort.


Assuntos
Piscadela/fisiologia , Túnica Conjuntiva/diagnóstico por imagem , Lentes de Contato Hidrofílicas , Córnea/diagnóstico por imagem , Exposição Ambiental , Satisfação do Paciente , Acuidade Visual , Adulto , Método Duplo-Cego , Feminino , Humanos , Masculino , Inquéritos e Questionários , Adulto Jovem
17.
Eye Contact Lens ; 43(1): 57-63, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26783978

RESUMO

OBJECTIVES: To evaluate the safety and efficacy of a new artificial tear containing 0.2% hyaluronic acid, as compared with 0.9% saline solution, in mild dry eye patients after 1-month use in a crossover study design with washout periods. METHODS: Overall, 16 mild dry eye patients were included. After a week of washout, every patient used the experimental product (Visaid 0.2%) and the control product (0.9% saline solution), each for a month (3-8 drops daily). Both products were preservative free. The percentage change for the following variables were calculated and analyzed: Ocular Surface Disease Index (OSDI) questionnaire, visual acuity, intraocular pressure, ophthalmoscopy evaluation, biomicroscopy findings, fluorescein corneal staining and lissamine green conjunctival staining, tear breakup time, contrast sensitivity, Schirmer's test, and subject satisfaction. RESULTS: Patients reported an improvement (a significant decrease of -19.5%±27.5%) in OSDI scores after using Visaid 0.2% and a worsening (a significant increase of 19.2%±32.4%) after using 0.9% saline solution; the difference was significant (P=0.0087, Student's t test). Significant changes (P≤0.04, Wilcoxon's test) were found comparing Visaid 0.2% with saline solution for bulbar hyperemia (-39.1%±50.8% vs. 7.8%±12.0%, respectively), corneal staining (-26.0%±53.0% vs. 36.5%±73.3%), conjunctival staining (-54.7%±53.4% vs. -7.8%±47.2%), and subjective satisfaction (26.8%±28.5% vs. -13.3%±22.5%). There were no significant differences in the safety parameters for either solution. CONCLUSION: This clinical trial demonstrates the safety of Visaid 0.2% and its clear benefit over 0.9% saline solution.


Assuntos
Síndromes do Olho Seco/tratamento farmacológico , Ácido Hialurônico/uso terapêutico , Lubrificantes Oftálmicos/uso terapêutico , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Estudos Cross-Over , Método Duplo-Cego , Síndromes do Olho Seco/fisiopatologia , Feminino , Humanos , Ácido Hialurônico/efeitos adversos , Pressão Intraocular/fisiologia , Lubrificantes Oftálmicos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Estudos Prospectivos , Cloreto de Sódio , Inquéritos e Questionários , Resultado do Tratamento , Acuidade Visual/fisiologia
18.
Eye Contact Lens ; 43(6): 383-388, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27243353

RESUMO

PURPOSE: To evaluate the safety and efficacy of a new 0.3% hyaluronic acid artificial tear compared with 0.9% saline solution (0.9% NaCl) in moderate-to-severe dry eye patients after 1 month's use. METHODS: A total of 16 patients with moderate-to-severe dry eye were included in this crossover study. After a 1-week washout period, patients used the experimental (Visaid 0.3%) or control solution (0.9% NaCl), selected randomly, applying three to eight drops daily for a month. After another washout period, patients used the other solution in the same way. Percentage of change (ΔY) was calculated and analyzed for (1) safety variables: visual acuity, intraocular pressure, and ophthalmoscopy evaluation; (2) efficacy variable: Ocular Surface Disease Index (OSDI) questionnaire; and (3) secondary variables: biomicroscopy findings, fluorescein corneal staining, lissamine green conjunctival staining, tear breakup time (TBUT), contrast sensitivity, Schirmer test, and subject satisfaction. RESULTS: There were no significant differences in the safety parameters for either solution. After using Visaid 0.3%, patients showed significant improvements in OSDI score (ΔY: -9.66%±10.90), tarsal hyperemia (ΔY: -16.67%±27.89), corneal staining extension (ΔY: -34.90%±42.41), TBUT (ΔY: 13.98%±26.19), and subjective satisfaction (ΔY: 38.06%±47.06). When using 0.9% NaCl, Schirmer test results were significantly worse (ΔY: -11.47%±19.27). A significant difference between the 2 solutions was found in TBUT (ΔY: 13.98%±26.19 vs. 10.15%±42.34, respectively; P=0.0214). CONCLUSION: Visaid 0.3% is a safe product with some benefits over 0.9% NaCl in reducing ocular symptoms and improving some ocular signs in patients with moderate-to-severe dry eye.


Assuntos
Síndromes do Olho Seco/tratamento farmacológico , Ácido Hialurônico/uso terapêutico , Lubrificantes Oftálmicos/uso terapêutico , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Córnea/metabolismo , Estudos Cross-Over , Método Duplo-Cego , Síndromes do Olho Seco/fisiopatologia , Feminino , Humanos , Ácido Hialurônico/efeitos adversos , Pressão Intraocular/fisiologia , Lubrificantes Oftálmicos/efeitos adversos , Lubrificantes Oftálmicos/química , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Acuidade Visual/fisiologia
19.
Ophthalmology ; 123(1): 141-53, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26520171

RESUMO

PURPOSE: To assess the efficacy of topical 0.1% fluorometholone in dry eye disease (DED) patients for ameliorating the worsening of the ocular surface when exposed to adverse environments. DESIGN: Single-center, double-masked, randomized, vehicle-controlled clinical trial. PARTICIPANTS: Forty-one patients showing moderate to severe DED. METHODS: Patients randomly received 1 drop 4 times daily of either topical 0.1% fluorometholone (FML group) or topical polyvinyl alcohol (PA group) for 22 days. Corneal and conjunctival staining, conjunctival hyperemia, tear film breakup time (TBUT), tear osmolarity, and the Symptom Assessment in Dry Eye (SANDE) questionnaire scores were determined at baseline. Variables were reassessed on day 21 before and after undergoing a 2-hour controlled adverse environment exposure and again on day 22. MAIN OUTCOMES MEASURES: Percentage of patients showing an increase 1 point or more in corneal staining and a reduction of 2 points or more (0-10 scale) in SANDE score, after the controlled adverse environment exposure and 24 hours later. RESULTS: After 21 days of treatment, the FML group showed greater improvements in corneal and conjunctival staining, hyperemia, and TBUT than the PA group (P≤0.03). After the adverse exposure, the percentage of patients having a 1-grade or more increase in corneal staining was significantly (P = 0.03) higher in the PA group (63.1% vs. 23.8%, respectively). Additionally, the FML group showed no significant changes in corneal staining (mean, 0.86; 95% confidence interval [CI], 0.47-1.25; vs. mean, 1.05; 95% CI, 0.59-1.51, for visit 2 and 3, respectively), conjunctival staining (mean, 0.95; 95% CI, 0.54-1.37 vs. mean, 1.19; 95% CI, 0.75-1.63), and hyperemia (mean, 0.71; 95% CI, 0.41-1.02 vs. 1.14; 95% CI, 0.71-1.58) after the exposure, whereas for the PA group, there was significant worsening (P≤0.009) in these variables (corneal staining: mean, 1.95; 95% CI, 1.57-2.33 vs. mean, 2.58; 95% CI, 2.17-2.98; conjunctival staining: mean, 1.68; 95% CI, 1.29-2.08 vs. mean, 2.47; 95% CI, 2.07-2.88; hyperemia: mean, 1.95; 95% CI, 1.63-2.26 vs. mean, 2.84; 95% CI, 2.62-3.07). CONCLUSIONS: Three-week topical 0.1% fluorometholone therapy is effective not only in reducing ocular surface signs in DED patients, but also especially in preventing exacerbation caused by exposure to a desiccating stress.


Assuntos
Túnica Conjuntiva/efeitos dos fármacos , Córnea/efeitos dos fármacos , Desidratação/complicações , Síndromes do Olho Seco/tratamento farmacológico , Fluormetolona/administração & dosagem , Administração Tópica , Túnica Conjuntiva/patologia , Córnea/patologia , Desidratação/patologia , Relação Dose-Resposta a Droga , Método Duplo-Cego , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/patologia , Feminino , Glucocorticoides/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA