RESUMO
BACKGROUND: The large dengue (DENV) and chikungunya (CHIKV) outbreaks observed during the last decade across the world, as well as local transmissions in non-endemic areas are a growing concern for blood safety. The aim of this study was to evaluate and compare the sensitivity of nucleic acid tests (NAT) detecting DENV and CHIKV RNA. MATERIALS AND METHODS: Using DENV 1 to 4 International Standards, the limits of detection (LODs) calculated by probit analysis of two NAT assays; the cobas CHIKV/DENV assay (Roche Diagnostics) and the Procleix Dengue Virus Assay (Grifols) were compared. In addition, CHIKV-RNA LOD of the cobas CHIKV/DENV assay was evaluated. RESULTS: For dengue, the 95% LOD of the cobas assay ranged between 4.10 [CI95%: 2.70-8.19] IU/mL (DENV-2) and 7.07 [CI95%: 4.34-14.89] IU/mL (DENV-4), and between 2.19 [CI95%: 1.53-3.83] IU/mL (DENV-3) and 5.84 [CI95%: 3.84-10.77] IU/mL (DENV-1) for Procleix assay. The Procleix assay had a significant lower LOD for DENV-3 (2.19 vs. 5.89 IU/mL) when compared to the cobas assay (p = 0.005). The 95% LOD for CHIKV-RNA detection of the cobas assay was 4.76 [CI95%: 3.08-8.94] IU/mL. DISCUSSION: The two NAT assays developed for blood donor screening evaluated in this study demonstrated high and similar analytical performance. Subject to an appropriate risk-benefit assessment, they can be used to support blood safety during outbreaks in endemic areas or in non-endemic areas as an alternative to deferring blood donors during local transmission likely to affect the blood supply. The development of multiplex assays is expected to optimize laboratory organization.
Assuntos
Febre de Chikungunya , Vírus Chikungunya , Vírus da Dengue , Dengue , RNA Viral , Humanos , Dengue/transmissão , Dengue/diagnóstico , Dengue/prevenção & controle , Dengue/sangue , Febre de Chikungunya/diagnóstico , Febre de Chikungunya/transmissão , Febre de Chikungunya/sangue , Febre de Chikungunya/prevenção & controle , RNA Viral/sangue , RNA Viral/análise , Técnicas de Amplificação de Ácido Nucleico/métodos , Segurança do Sangue/métodos , Transfusão de Sangue , Sensibilidade e Especificidade , Limite de DetecçãoRESUMO
In France, blood donations are tested in pools of 96 samples for parvovirus B19 (B19V) DNA to discard plasma for fractionation when it contains high viral loads. Between January 2015 and March 2024, B19V-positive donations decreased during the COVID-19 pandemic, followed by a strong rebound in 2023 and unusually high circulation during winter 2023/24 (ca 10 times higher December 2023-March 2024 vs the pre-pandemic period). Variations over time are probably related to measures implemented to limit SARS-CoV-2 spread.