Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Biophys J ; 119(2): 460-469, 2020 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-32645291

RESUMO

The monophasic action potential (MAP) is a near replica of the transmembrane potential recorded when an electrode is pushed firmly against cardiac tissue. Despite its many practical uses, the mechanism of MAP signal generation and the reason it is so different from unipolar recordings are not completely known and are a matter of controversy. In this work, we describe a method to simulate realistic MAP and intermediate forms, which are multiphasic electrograms different from an ideal MAP. The key ideas of our method are the formation of compressed zones and junctional spaces-regions of the extracellular and bath or blood pool directly in contact with electrodes that exhibit a pressure-induced reduction in electrical conductivity-and the presence of a complex network of passive components that acts as a high-pass filter to distort and attenuate the signal that reaches the recording amplifier. The network is formed by the interaction between the passive tissue properties and the double-layer capacitance of electrodes. The MAP and intermediate forms reside on a continuum of signals, which can be generated by the change of the model parameters. Our model helps to decipher the mechanisms of signal generation and can lead to a better design for electrodes, recording amplifiers, and experimental setups.


Assuntos
Coração , Potenciais de Ação , Condutividade Elétrica , Eletrodos , Potenciais da Membrana
2.
Pacing Clin Electrophysiol ; 40(5): 467-475, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28224629

RESUMO

OBJECTIVES: This study compared risks associated with magnetic resonance imaging (MRI) in patients with non-MRI conditional and MRI conditional pacing and defibrillator systems with particular attention to clinically actionable outcomes. BACKGROUND: While recipients of new MRI conditional pacemaker and defibrillator systems may undergo MRI scanning with very low risk, safety and regulatory concerns persist regarding such scanning in recipients of non-MRI conditional systems. METHODS: Patients with any cardiac device who were referred for MRI were prospectively enrolled at a single center and underwent scanning at 1.5 Tesla. Pre- and postscan lead characteristic changes, system integrity, and symptoms were analyzed. A comparison was made between non-MRI conditional and MRI conditional devices. RESULTS: 105 patients were evaluated allowing for comparison of 97 scans with non-MRI conditional devices and 16 scans with MRI conditional devices. The cohort included those with pacemaker dependency, defibrillator, and cardiac resynchronization devices. Small, nonsignificant changes were observed in lead characteristics following scanning, and there was no significant difference when comparing non-MRI and MRI conditional devices. Lead parameter changes did not require lead revision or programming changes. No device reset, failures, or premature scan termination was observed. CONCLUSIONS: 1.5 T MRI scanning in patients with MRI conditional and non-MRI conditional cardiac devices was performed with similar, low clinical risk.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Traumatismos por Eletricidade/epidemiologia , Falha de Equipamento/estatística & dados numéricos , Segurança de Equipamentos/estatística & dados numéricos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Idoso , Causalidade , Contraindicações , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Georgia/epidemiologia , Humanos , Masculino , Prevalência , Fatores de Risco
3.
Chaos ; 27(9): 093925, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28964135

RESUMO

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia with significant morbidity and mortality. Pharmacological agents are not very effective in the management of AF. Therefore, ablation procedures have become the mainstay of AF management. The irregular and seemingly chaotic atrial activity in AF is caused by one or more meandering spiral waves. Previously, we have shown the presence of sudden rhythm organization during ablation of persistent AF. We hypothesize that the observed transitions from a disorganized to an organized rhythm is a critical phase transition. Here, we explore this hypothesis by simulating ablation in an anatomically-correct 3D AF model. In 722 out of 2160 simulated ablation, at least one sudden transition from AF to an organized rhythm (flutter) was noted (33%). They were marked by a sudden decrease in the cycle length entropy and increase in the mean cycle length. At the same time, the number of reentrant wavelets decreased from 2.99 ± 0.06 in AF to 1.76 ± 0.05 during flutter, and the correlation length scale increased from 13.3 ± 1.0 mm to 196.5 ± 86.6 mm (both P < 0.0001). These findings are consistent with the hypothesis that transitions from AF to an anatomical flutter behave as phase transitions in complex non-equilibrium dynamical systems with flutter acting as an absorbing state. Clinically, the facilitation of phase transition should be considered a novel mechanism of ablation and may help to design effective ablation strategies.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Fenômenos Eletrofisiológicos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Modelos Anatômicos , Fatores de Tempo
4.
J Cardiovasc Electrophysiol ; 27(7): 820-4, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27037913

RESUMO

INTRODUCTION: Intracardiac electrogram voltage remains an important metric for radiofrequency lesion application. Embedded micro-electrodes within ablation catheters are now approved for use in humans. OBJECTIVE: This study examined electrogram characteristics of miniaturized electrode bipoles (iEGMmini ) compared to distal ablation tip bipoles (iEGMstandard ) in the setting of typical atrial flutter in humans. METHODS: This was a single-center prospective trial involving 21 patients. A total of 54 non-ablated and 56 ablated sites were analyzed offline by separate blinded observers for iEGM voltage after a clinically successful radiofrequency (RF) ablation for typical atrial flutter. Ablation sites were defined as sites that were localized anatomically within the RF lesion set and did not have atrial capture at 10 mA and 2 milliseconds. Non-ablated sites were defined as sites adjacent to or remote from the ablation lesion set with capture at 10 mA and 2 milliseconds. RESULTS: iEGMmini had greater voltages at non-ablated sites and lower voltages at ablated sites than iEGMstandard (non-ablated sites iEGMstandard 0.64 mV vs. iEGMmini 1.0 mV; ablated sites iEGMstandard 0.15 mV, iEGMmini 0.08 mV, P < 0.001). The difference for each patient between ablated and non-ablated sites was greater for iEGMmini compared to iEGMstandard (0.94 mV ± 0.57 iEGMmini vs. 0.52 mV ± 0.35 iEGMstandard , P < 0.001). Inter-observer agreement was good among all non-ablated sites and iEGMmini ablated sites, but was less robust for ablated sites using iEGMstandard . CONCLUSIONS: Imbedded mini-electrode iEGM bipoles had higher voltages in non-ablated tissue, lower voltages in ablated tissue, and significantly greater intra-patient differences between ablated and non-ablated sites. These data suggest a potential role for miniaturized electrode bipole use in RF lesion monitoring.


Assuntos
Flutter Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Eletrodos Implantados , Técnicas Eletrofisiológicas Cardíacas , Miocárdio/patologia , Potenciais de Ação , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Georgia , Frequência Cardíaca , Humanos , Miniaturização , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 39(1): 101-4, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26293817

RESUMO

Defibrillator lead malfunction can be a disastrous complication, leading to loss of protection from sudden cardiac death in a high-risk patient population. Recognition of lead-specific risk for failure can assist in development of focused screening or surveillance, as in the case of the Riata lead (St. Jude Medical, St. Paul, MN, USA) or the Sprint Fidelis lead (Medtronic Inc., Minneapolis, MN, USA). A case of defibrillation failure secondary to a Durata lead insulation failure is presented. A brief review of the literature and current St. Jude Medical implantable cardiac defibrillator lead design is presented. Identification of arcing is identified as a potential sign of catastrophic insulation failure.


Assuntos
Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Adulto , Falha de Equipamento , Evolução Fatal , Humanos , Masculino , Falha de Tratamento
6.
J Cardiovasc Electrophysiol ; 26(8): 900-904, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25952566

RESUMO

BACKGROUND: Although the subcutaneous ICD (S-ICD®) is an attractive alternative in patients with end-stage renal disease (ESRD), data on S-ICD outcomes in dialysis patients are lacking. METHODS: Patients with cardiomyopathy undergoing S-ICD implantation in our center were stratified by need for chronic dialysis at the time of implant. The primary endpoint was incidence of death, heart failure hospitalization or appropriate S-ICD shocks, and secondary endpoints were incidence of inappropriate shocks or implant related complications requiring surgical re-intervention. Mean follow-up was longer in the nondialysis cohort (514 ± 495 vs. 227 ± 233 days, P = 0.006), so all endpoints were analyzed using time-dependent comparisons and reported as annual event rates. RESULTS: Out of 79 S-ICD implants included in this analysis, 27 patients were on dialysis. Dialysis patients were older and more likely to be diabetic. Mean ejection fraction across the entire cohort was 26.9% without significant difference between dialysis and nondialysis groups. Although not significant, the incidence of the primary endpoint was higher in the dialysis cohort (23.8%/year vs. 10.9%/year, P = 0.317), driven primarily by a higher rate of appropriate shocks. The rate of inappropriate shocks was similar between groups (dialysis 6.0%/year vs. nondialysis 6.8%/year, P = 0.509). No patients in the dialysis cohort had complications requiring surgical re-intervention versus 6 patients in the nondialysis cohort (P = 0.086). CONCLUSIONS: Our data suggest that S-ICD implantation in dialysis patients is not associated with an excess risk of implant related complications or inappropriate shocks.


Assuntos
Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Falência Renal Crônica/terapia , Diálise Renal , Adulto , Idoso , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Georgia , Humanos , Estimativa de Kaplan-Meier , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/mortalidade , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Diálise Renal/efeitos adversos , Diálise Renal/mortalidade , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
7.
Pacing Clin Electrophysiol ; 38(11): 1297-303, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26256667

RESUMO

BACKGROUND: Little data exist on long-term outcomes following extraction of implantable cardioverter defibrillator (ICD) leads, particularly for noninfectious indications. We sought to identify predictors of long-term survival after ICD lead extraction. METHODS: We retrospectively reviewed ICD lead extractions at our institution (n = 508). Procedural outcomes and long-term survival were ascertained by medical records review. RESULTS: Indication for lead extraction was infection in 32.5% and lead failure in 61.8%. Mean dwell time of the oldest extracted lead was 5.1 ± 5.9 years. Complete procedural success was achieved in 96.5% of cases. Major procedure-related complications occurred in 1.6% with six periprocedural deaths. During a mean follow-up of 866 ± 798 days, survival was significantly worse among patients with infection as the indication for extraction. At 1 year after extraction, survival among those with infection was 88.2%, compared to 95.0% in the lead failure cohort (P < 0.001). Procedural failure was a significant predictor of long-term mortality, even after excluding periprocedural deaths. In multivariate models, the presence of chronic kidney disease, increased number of leads requiring extraction, lower ejection fraction, and procedural failure were predictors of mortality. CONCLUSION: Despite high rates of procedural success, infectious indication for ICD lead extraction is associated with increased long-term mortality. In contrast, among patients undergoing extraction for lead failure, long-term survival was excellent. The presence of procedural failure was a significant predictor of long-term mortality. Further studies will be necessary to better understand the mechanisms by which procedural failure may adversely impact long-term outcomes.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Remoção de Dispositivo/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo , Veias
8.
Pacing Clin Electrophysiol ; 38(12): 1434-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26285670

RESUMO

BACKGROUND: St. Jude Riata/Riata ST defibrillator leads (St. Jude Medical, Sylmar, CA, USA) were recalled by the Food and Drug Administration in 2011 for an increased rate of failure. More than 227,000 leads were implanted and at least 79,000 patients still have active Riata leads. Studies have examined clinical predictors of lead failure in Riata leads, but none have addressed the effect of implantable cardioverter defibrillator (ICD) generator exchange on lead failure. The purpose of this study is to assess the effect of ICD generator exchange on the rate of electrical failure in the Riata lead at 1 year. METHODS: A retrospective chart review was conducted in patients who underwent implantation of a Riata/Riata ST lead at one center. Patients with a functioning Riata lead (with/without externalized conductor) at the time of ICD exchange were compared to controls with Riata leads implanted for a comparable amount of time who did not undergo generator replacement. RESULTS: Riata leads were implanted in 1,042 patients prior to the recall and 153 of these patients underwent generator exchange without lead replacement. Conductor externalization was noted in 21.5% of Riata leads in the ICD exchange cohort, which was not different from the control group (19.2%; P = 0.32). Two leads failed in the first year after generator replacement (1.5%) which did not significantly differ from the control group (2.0%; P = 0.57). At change-out, 54% received a commanded shock (18.6 ± 0.9 J) that did not result in any change in the high-voltage lead impedance (46.1 ± 1.1 ohms). CONCLUSIONS: Conductor externalization was seen frequently in our cohort of patients. ICD generator exchange did not accelerate the rate of Riata lead failure at 1 year. Although both the control and the change-out cohorts failed at a rate much greater than nonrecalled leads, generator exchange did not appear to add to the problem.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Recall de Dispositivo Médico , Estudos de Coortes , Feminino , Georgia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco
9.
Pacing Clin Electrophysiol ; 37(3): 321-8, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24164147

RESUMO

BACKGROUND: Although left ventricular (LV) systolic dysfunction is known to occur in adults with repaired Tetralogy of Fallot (TOF), the effects of cardiac resynchronization therapy (CRT) are not well characterized. METHODS: We retrospectively divided all patients with repaired TOF and impaired LV ejection fraction (LVEF ≤ 40%) undergoing CRT at our institution (n = 10) into two groups: de novo CRT (group A, n = 6) or upgrade from existing device (group B, n = 4). Echocardiograms were reviewed at baseline, medium-term (>6 months post-CRT), and long-term follow-up. CRT response was defined as reduction in LV end-systolic volume (LVESV) ≥15% at medium term. RESULTS: Age at surgical repair was 13.1 ± 16.0 years, age at CRT was 44.4 ± 12.5 years, and baseline LVEF was 24.0 ± 10.5%. Group A demonstrated a preponderance of right ventricular (RV) conduction delay, whereas all patients in group B demonstrated RV pacing at baseline. At medium-term follow-up, patients in group A showed significant improvements in LVEF, LV end-diastolic volume (LVEDV), and LVESV. Group B also demonstrated a significant improvement in LVEF with favorable trends in LV volumes. Of nine patients with complete data at medium term, eight showed evidence of CRT response. Average long-term follow-up was 53.4 ± 29.3 months. At long-term follow-up, LVEF, LVEDV, and LVESV remained numerically better than baseline, although the results were no longer significant. CONCLUSIONS: Adult patients with repaired TOF and LV systolic dysfunction demonstrate significant medium-term response to CRT, even among those with RV conduction delay. The long-term impact of CRT in this population requires further characterization.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Insuficiência Cardíaca/cirurgia , Procedimentos de Cirurgia Plástica/efeitos adversos , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/prevenção & controle , Adolescente , Adulto , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Estudos Retrospectivos , Tetralogia de Fallot/complicações , Disfunção Ventricular Esquerda/diagnóstico , Adulto Jovem
10.
Nat Biomed Eng ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698155

RESUMO

The adenovirus-mediated somatic transfer of the embryonic T-box transcription factor 18 (TBX18) gene can convert chamber cardiomyocytes into induced pacemaker cells. However, the translation of therapeutic TBX18-induced cardiac pacing faces safety challenges. Here we show that the myocardial expression of synthetic TBX18 mRNA in animals generates de novo pacing and limits innate and inflammatory immune responses. In rats, intramyocardially injected mRNA remained localized, whereas direct myocardial injection of an adenovirus carrying a reporter gene resulted in diffuse expression and in substantial spillover to the liver, spleen and lungs. Transient expression of TBX18 mRNA in rats led to de novo automaticity and pacemaker properties and, compared with the injection of adenovirus, to substantial reductions in the expression of inflammatory genes and in activated macrophage populations. In rodent and clinically relevant porcine models of complete heart block, intramyocardially injected TBX18 mRNA provided rate-adaptive cardiac pacing for one month that strongly correlated with the animal's sinus rhythm and physical activity. TBX18 mRNA may aid the development of biological pacemakers.

11.
BMC Med Genet ; 14: 4, 2013 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-23302509

RESUMO

BACKGROUND: Age-related macular degeneration (AMD) is the leading cause of vision loss in elderly, Caucasian populations. There is strong evidence that mitochondrial dysfunction and oxidative stress play a role in the cell death found in AMD retinas. The purpose of this study was to examine the association of the Caucasian mitochondrial JTU haplogroup cluster with AMD. We also assessed for gender bias and additive risk with known high risk nuclear gene SNPs, ARMS2/LOC387715 (G > T; Ala69Ser, rs10490924) and CFH (T > C; Try402His, rs1061170). METHODS: Total DNA was isolated from 162 AMD subjects and 164 age-matched control subjects located in Los Angeles, California, USA. Polymerase chain reaction (PCR) and restriction enzyme digestion were used to identify the J, U, T, and H mitochondrial haplogroups and the ARMS2-rs10490924 and CFH-rs1061170 SNPs. PCR amplified products were sequenced to verify the nucleotide substitutions for the haplogroups and ARMS2 gene. RESULTS: The JTU haplogroup cluster occurred in 34% (55/162) of AMD subjects versus 15% (24/164) of normal (OR = 2.99; p = 0.0001). This association was slightly greater in males (OR = 3.98, p = 0.005) than the female population (OR = 3.02, p = 0.001). Assuming a dominant effect, the risk alleles for the ARMS2 (rs10490924; p = 0.00001) and CFH (rs1061170; p = 0.027) SNPs were significantly associated with total AMD populations. We found there was no additive risk for the ARMS2 (rs10490924) or CFH (rs1061170) SNPs on the JTU haplogroup background. CONCLUSIONS: There is a strong association of the JTU haplogroup cluster with AMD. In our Southern California population, the ARMS2 (rs10490924) and CFH (rs1061170) genes were significantly but independently associated with AMD. SNPs defining the JTU mitochondrial haplogroup cluster may change the retinal bioenergetics and play a significant role in the pathogenesis of AMD.


Assuntos
DNA Mitocondrial , Haplótipos , Degeneração Macular/genética , Idoso , California , Estudos de Casos e Controles , DNA Mitocondrial/genética , Feminino , Humanos , Degeneração Macular/etnologia , Masculino , Polimorfismo de Nucleotídeo Único , Fatores de Risco , População Branca/genética
12.
Europace ; 14(5): 761-6, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22183745

RESUMO

AIMS: Atrial fibrillation (AF)-induced electrical remodelling causes shortening of refractory period and slowing of conduction velocity. During the course of catheter ablation of AF, there are often transitions from AF to left atrial flutter (AFL) and from faster to slower AFL. The purpose of this study was to characterize the time course of change in AFL rate during AF ablation. METHODS AND RESULTS: Fourier transformation was performed on 16 s segments of coronary sinus and ablation catheter bipolar electrograms. Ablation-induced AF-to-AFL and AFL-to-AFL transitions were defined as a sudden drop in the dominant frequency (DF) of at least 10 bpm, followed by a regular rhythm. Forty-five transitions were detected in 24 ablation procedures. The mean DF in AF was 5.31 ± 0.79 Hz, which was significantly faster than AFL, 4.52 ± 0.62 Hz (P< 0.05). The mean ΔDF at transitions was -51 ± 16 bpm in AF and -40 ± 14 bpm in AFL. Dominant frequency slope was positive (rate increased) after all the transitions during AF (P< 0.0001) and in 11 of 14 transitions in AFL (P= 0.033). The time constant of the DF recovery curve was 161 ± 105 s. CONCLUSIONS: After ablation-induced transition from AF to AFL, or faster to slower AFL, there is a progressive increase in AFL rate over time. The mechanism of this acceleration is uncertain, but the time constant of this rate increase is consistent with the recovery of the slow/ultraslow sodium current in the setting of established electrical remodelling.


Assuntos
Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Ablação por Cateter , Modelos Cardiovasculares , Potenciais de Ação/fisiologia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Eletrocardiografia/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Análise de Fourier , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
14.
Pacing Clin Electrophysiol ; 35(2): 170-3, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22017595

RESUMO

BACKGROUND: Dofetilide, a class III antiarrhythmic, is one of the few alternatives to amiodarone in patients with atrial fibrillation (AF) and heart failure or coronary artery disease (CAD). While amiodarone has been extensively studied, little is known about predictors of response to dofetilide. We sought to identify clinical parameters associated with dofetilide success in a large cohort of patients with AF. METHODS/RESULTS: A total of 287 patients with AF started on dofetilide between 2001 and 2008 were included. Dofetilide was deemed "completely effective" if the patient remained on dofetilide at follow-up and had no recurrences of AF clinically or by electrocardiogram. Dofetilide efficacy was analyzed in relation to clinical variables relevant to AF and AF recurrence. After a follow-up of 10.2 ± 7.7 months, 54.7% of the patients remained on dofetilide and it was completely effective in 26.8%. The discontinuation rate during initial hospitalization was 13.3% from excessive QT prolongation and one patient with torsades de pointes (successfully treated). A history of CAD was the only univariate predictor of efficacy (odds ratio [OR] 2.27, 95% confidence interval [CI] 1.29-4.01, P < 0.05). CAD remained the only significant factor associated with efficacy of dofetilide in a multivariate regression model (OR 2.01, 95% CI 1.11-3.70, P < 0.05, n = 270). The overall efficacy of dofetilide in patients with CAD was 41.1%, compared to 23.5% in those without CAD (P < 0.05). CONCLUSIONS: In this large cohort of patients with AF, underlying coronary disease was significantly associated with dofetilide success. This finding may have utility for clinical decisions regarding initiation of dofetilide.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Doença da Artéria Coronariana/epidemiologia , Fenetilaminas/administração & dosagem , Sulfonamidas/administração & dosagem , Antiarrítmicos/administração & dosagem , Comorbidade , Doença da Artéria Coronariana/tratamento farmacológico , Sinergismo Farmacológico , Feminino , Georgia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Resultado do Tratamento
15.
Pacing Clin Electrophysiol ; 35(4): 431-43, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22303998

RESUMO

BACKGROUND: Patients receiving an implantable cardioverter defibrillator (ICD) report various types and degree of sleep disruptions, but little is known regarding their characteristics, duration, and associated factors. The purposes of this study were: (1) to describe the effect of a psychoeducational intervention on sleep quality and daytime sleepiness, (2) to describe patterns of sleep over time, and (3) to identify predictors of poor sleep in an ICD population. METHODS: A randomized longitudinal intervention trial was designed to test the effects of a psychoeducational intervention, which included a sleep education and counseling session in patients receiving their initial ICD. Patients (n=236; 75% men; mean age 58.4 [±11.2] from the PsychoEducationAl Intervention for ICD PatiEnts (PEACE) trial comprised the study population. Variables related to sleep were measured by the Pittsburgh Sleep Quality Inventory (PSQI) and Epworth Sleepiness Scale (ESS). RESULTS: No psychoeducational intervention effects on sleep outcomes were observed. However, 67.2% of the patients reported poor sleep quality at baseline, and 56.8% had low sleep quality at 6 months based on PSQI scores>5; one-third (32.6%) were excessively sleepy based on ESS scores≥10 at 6 months. Anxiety, depression, physical function, pain intensity, and pain severity were all highly correlated to each other across time. Female gender was a significant covariate for the PSQI. New York Heart Association (NYHA) class was a significant covariate for sleepiness (Epworth). CONCLUSIONS: Low sleep quality and daytime sleepiness are found at time of insertion and over time in patients with ICD. Female gender, higher NYHA class, as well as two latent factors encompassing increased anxiety, depressive symptoms, and decreased physical function and increased pain, were significant predictors of poor sleep quality and sleepiness over time. These data help identify those at higher risk for sleep problems after ICD.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Distúrbios do Sono por Sonolência Excessiva/etiologia , Sono , Idoso , Ansiedade/complicações , Depressão/complicações , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Dor/complicações , Risco , Índice de Gravidade de Doença , Fatores Sexuais
16.
Circulation ; 122(16): 1553-61, 2010 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-20921437

RESUMO

BACKGROUND: Prospective studies defining the risk associated with pacemaker or implantable cardioverter-defibrillator replacement surgeries do not exist. These procedures are generally considered low risk despite results from recent retrospective series reporting higher rates. METHODS AND RESULTS: We prospectively assessed predefined procedure-related complication rates associated with elective pacemaker or implantable cardioverter-defibrillator generator replacements over 6 months of follow-up. Two groups were studied: those without (cohort 1) and those with (cohort 2) a planned transvenous lead addition for replacement or upgrade to a device capable of additional therapies. Complications were adjudicated by an independent events committee. Seventy-two US academic and private practice centers participated. Major complications occurred in 4.0% (95% confidence interval, 2.9 to 5.4) of 1031 cohort 1 patients and 15.3% (95% confidence interval, 12.7 to 18.1) of 713 cohort 2 patients. In both cohorts, major complications were higher with implantable cardioverter-defibrillator compared with pacemaker generator replacements. Complications were highest in patients who had an upgrade to or a revised cardiac resynchronization therapy device (18.7%; 95% confidence interval, 15.1 to 22.6). No periprocedural deaths occurred in either cohort, although 8 later procedure-related deaths occurred in cohort 2. The 6-month infection rates were 1.4% (95% confidence interval, 0.7 to 2.3) and 1.1% (95% confidence interval, 0.5 to 2.2) for cohorts 1 and 2, respectively. CONCLUSIONS: Pacemaker and implantable cardioverter-defibrillator generator replacements are associated with a notable complication risk, particularly those with lead additions. These data support careful decision making before device replacement, when managing device advisories, and when considering upgrades to more complex systems.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Complicações Pós-Operatórias/epidemiologia , Sistema de Registros , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos , Estudos de Coortes , Falha de Equipamento , Feminino , Seguimentos , Parada Cardíaca/epidemiologia , Hematoma/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Trombose Venosa/epidemiologia
17.
Artigo em Inglês | MEDLINE | ID: mdl-35754518

RESUMO

Diagnosis and localization of cardiac arrhythmias, especially supraventricular tachycardia (SVT), by inspecting intracardiac signals and performing pacing maneuvers is the core of electrophysiology studies. Acquiring and maintaining complex skill sets can be facilitated by using simulators, allowing the operator to practice in a safe and controlled setting. An electrophysiology simulator should not only display arrhythmias but it has to respond to the user's arbitrary inputs. While, in principle, it is possible to model the heart using a detailed anatomical and cellular model, such a system would be unduly complex and computationally intensive. In this paper, we describe a freely available web-based electrophysiology simulator (http://svtsim.com), which is composed of a visualization/interface unit and a heart model based on a dynamical network. In the network, nodes represent the points of interest, such as the sinus and the atrioventricular nodes, and links model the conduction system and pathways. The dynamics are encoded explicitly in the state machines attached to the nodes and links. Simulated intracardiac signals and surface ECGs are generated from the internal state of the heart model. Reentrant tachycardias, especially various forms of SVT, can emerge in this system in response to the user's actions in the form of pacing maneuvers. Additionally, the resulting arrhythmias respond realistically to various inputs, such as overdrive pacing and delivery of extra stimuli, cardioversion, ablation, and infusion of medications. For nearly a decade, svtsim.com has been used successfully to train electrophysiology practitioners in many institutions. We will present our experience regarding best practices in designing and using electrophysiology simulators for training and testing. We will also discuss the current trends in clinical cardiac electrophysiology and the anticipated next generation electrophysiology simulators.

18.
Circulation ; 117(19): 2510-4, 2008 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-18458166

RESUMO

BACKGROUND: Brief interruptions in chest compressions reduce the efficacy of resuscitation from cardiac arrest. Interruptions of this type are inevitable during hands-off periods for shock delivery to treat ventricular tachyarrhythmias. The safety of a rescuer remaining in contact with a patient being shocked with modern defibrillation equipment has not been investigated. METHODS AND RESULTS: This study measured the leakage voltage and current through mock rescuers while they were compressing the chests of 43 patients receiving external biphasic shocks. During the shock, the rescuer's gloved hand was pressed onto the skin of the patient's anterior chest. To simulate the worst case of an inadvertent return current pathway, a skin electrode on the rescuers thigh was connected to an electrode on the patient's shoulder. In no cases were shocks perceptible to the rescuer. Peak potential differences between the rescuer's wrist and thigh ranged from 0.28 to 14 V (mean 5.8+/-5.8 V). The average leakage current flowing through the rescuer's body for each phase of the shock waveform was 283+/-140 microA (range 18.9 to 907 microA). This was below several recommended safety standards for leakage current. CONCLUSIONS: Rescuers performing chest compressions during biphasic external defibrillation are exposed to low levels of leakage current. The present findings support the feasibility of uninterrupted chest compressions during shock delivery, which may enhance the efficacy of defibrillation and cardiocerebral resuscitation.


Assuntos
Cardioversão Elétrica/métodos , Traumatismos por Eletricidade/etiologia , Parada Cardíaca/terapia , Ressuscitação/métodos , Cardioversão Elétrica/efeitos adversos , Mãos , Massagem Cardíaca , Humanos , Ressuscitação/efeitos adversos , Taquicardia Ventricular
19.
Cell Tissue Res ; 335(1): 67-73, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18682987

RESUMO

During early gastrulation, vertebrate embryos begin to produce endothelial cells (ECs) from the mesoderm. ECs first form primitive vascular plexus de novo and later differentiate into arterial, venous, capillary, and lymphatic ECs. In the heart, the five distinct EC types (endocardial, coronary arterial, venous, capillary, and lymphatic) have distinct phenotypes. For example, coronary ECs establish a typical vessel network throughout the myocardium, whereas endocardial ECs form a large epithelial sheet with no angiogenic sprouting into the myocardium. Neither coronary arteries, veins, and capillaries, nor lymphatic vessels fuse with the endocardium or open to the heart chamber. The developmental stage during which the specific phenotype of each cardiac EC type is determined remains unclear. The mechanisms involved in EC commitment and diversity can however be more precisely defined by tracking the migratory patterns and lineage decisions of the precursors of cardiac ECs.


Assuntos
Linhagem da Célula/fisiologia , Células Endoteliais/citologia , Mesoderma/citologia , Miocárdio/citologia , Animais , Vasos Sanguíneos/citologia , Vasos Sanguíneos/embriologia , Movimento Celular/fisiologia , Células Endoteliais/fisiologia , Coração/embriologia , Humanos , Vasos Linfáticos/citologia , Vasos Linfáticos/embriologia , Mesoderma/embriologia
20.
J Cardiovasc Electrophysiol ; 20(4): 453-60, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19347996

RESUMO

Modern implantable devices capable of pacing are armed with a multitude of programmable and automated features. While some features represent important advances in device safety and performance, many can also mimic device malfunction. This article discusses these features in terms of the confusion they may cause and highlights important clinical clues that aid in their recognition.


Assuntos
Artefatos , Estimulação Cardíaca Artificial , Erros de Diagnóstico/prevenção & controle , Eletrocardiografia Ambulatorial , Marca-Passo Artificial , Telemetria , Algoritmos , Automação , Estimulação Cardíaca Artificial/efeitos adversos , Qualidade de Produtos para o Consumidor , Desenho de Equipamento , Falha de Equipamento , Segurança de Equipamentos , Humanos , Marca-Passo Artificial/efeitos adversos , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA