Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Revista
País de afiliação
Intervalo de ano de publicação
1.
Vasa ; 50(3): 186-192, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33559507

RESUMO

Background: Our aim was to determine the rate of ischemic stroke following thoracic endovascular aortic repair (TEVAR) after reducing gas volume released during stentgraft deployment by de-airing of thoracic stentgrafts with high-volume of 0.9% heparinized saline solution. Patients and methods: A single center retrospective analysis of all consecutive patients undergoing TEVAR from 2014 to 2019 was performed. All thoracic stentgrafts were flushed with 120 ml 0.9% heparinized saline solution before implantation, according to our institutional protocol. Endpoints were in-hospital rates of ischemic stroke and spinal cord ischemia (SCI), and all-cause mortality. Results: One hundred and fifty-four patients (mean age: 66.8 ± 13.6 years, 64.9% males) were treated with TEVAR during the study period. Indications for treatment were thoracic aortic aneurysms (n = 75, 48.7%), acute type B aortic dissections (n = 46, 29.9%), aortic arch aneurysms and penetrating aortic ulcers (n = 28, 18.2%), and blunt traumatic aortic injuries (n = 5, 3.2%). Timing of procedure was urgent in 75 patients (48.7%). Proximal landing zone were zone 0-1-2 (n = 75, 48.7%), zone 3 (n = 66, 42.9%) and zone 4 (n = 13, 8.4%). Supra-aortic vessels were revascularized with custom-made fenestrated stentgrafts in 9 patients (5.8%), using chimney technique in 4 patients (2.6%), and with debranching procedures in 19 patients (12.3%). Left subclavian artery was covered without revascularization in 46 patients (29.9%). In-hospital stroke occurred in two patients (1.3%) and SCI in another two patients (1.3%). In-hospital mortality rate was 0.6%. No further in-hospital events were noted. Conclusions: De-airing of stentgrafts with high-volume of 0.9% heparinized saline solution seems to be safe and can be used as an adjunct to keep occurrence of neurological events after TEVAR as low as possible.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Solução Salina , Stents , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA