Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Arch Microbiol ; 206(3): 97, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38349544

RESUMO

Cordyceps militaris is a well-known medicinal mushroom in Asian countries. This edible fungus has been widely exploited for traditional medicine and functional food production. C. militaris is a heterothallic fungus that requires both the mating-type loci, MAT1-1 and MAT1-2, for fruiting body formation. However, recent studies also indicated two groups of C. militaris, including monokaryotic strains carrying only MAT1-1 in their genomes and heterokaryotic strains harboring both MAT1-1 and MAT1-2. These strain groups are able to produce fruiting bodies under suitable cultivating conditions. In previous work, we showed that monokaryotic strains are more stable than heterokaryotic strains in fruiting body formation through successive culturing generations. In this study, we report a high cordycepin-producing monokaryotic C. militaris strain (HL8) collected in Vietnam. This strain could form normal fruiting bodies with high biological efficiency and contain a cordycepin content of 14.43 mg/g lyophilized fruiting body biomass. The ethanol extraction of the HL8 fruiting bodies resulted in a crude extract with a cordycepin content of 69.15 mg/g. Assays of cytotoxic activity on six human cancer cell lines showed that the extract inhibited the growth of all these cell lines with the IC50 values of 6.41-11.51 µg/mL. Notably, the extract significantly reduced cell proliferation and promoted apoptosis of breast cancer cells. Furthermore, the extract also exhibited strong antifungal activity against Malassezia skin yeasts and the citrus postharvest pathogen Penicillium digitatum. Our work provides a promising monokaryotic C. militaris strain as a bioresource for medicine, cosmetics, and fruit preservation.


Assuntos
Antineoplásicos , Cordyceps , Neoplasias , Penicillium , Humanos , Penicillium/genética , Carpóforos
2.
Foot Ankle Surg ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38987122

RESUMO

BACKGROUND: Smoking has long been recognized as a risk factor for impaired wound and bone healing, particularly in the context of ankle and foot surgery. Despite numerous studies exploring the association between smoking and complications following ankle replacement, there remains significant inconsistency in their findings. Therefore, this meta-analysis study aims to elucidate whether smoking increases the rate of complications after total ankle arthroplasty (TAA), providing valuable insights for clinical management. METHODS: A comprehensive systematic search was conducted in the PubMed, Embase, and Wiley databases to identify relevant English studies on the influence of smoking on postoperative complications following ankle replacement without any restrictions on publication dates. The quality of the included studies was assessed using the Newcastle-Ottawa Scale. Random-effect models were used to calculate odds ratios (OR) and 95 % confidence intervals (CI). This study adhered to PRISMA guidelines for transparent reporting and was registered with PROSPERO. RESULTS: The analysis incorporated data from 12 retrospective cohort studies, totaling 17331 subjects, 2580 of whom were smokers and 791 complications following TAA. The findings revealed a statistically significant disparity in wound-related complications (OR: 2.26; 95 % CI: 1.13-4.50; P = .02), particularly evident in current smokers with an OR of 3.30 (95 % CI: 2.12-5.14; P < .00001). However, we lacked sufficient evidence to substantiate an association between smoking and complications related to the prosthesis (OR: 1.09; 95 % CI: 0.77-1.53; P = .64) or systemic complications (OR: 1.18; 95 % CI: 0.10-14.13; P = .90) following TAA. CONCLUSIONS: Smoking, especially current smoking, is associated with increased wound complication risk post-operation for total ankle arthroplasty. Despite a lack of definitive evidence on the optimal timeframe for smoking cessation before surgery, discontinuing smoking appears to be a prudent measure to mitigate these complications.

3.
ScientificWorldJournal ; 2020: 6829153, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32848513

RESUMO

This study examined the postoperative pain management practices among registered nurses in an urban hospital in Vietnam. Data of 90 nurses about postoperative pain management practices and pain management at the department were collected. Results indicated that 83.3% of nurses reported that they regularly assessed the degree of pain for postoperative patients. Only 32.2% used assessment tools such as the numeric rating scale to measure pain. Experience in pain management and having guidelines in the department were associated with a higher score in pain management practice. Findings suggested that facilitating the use of pain instruments and developing pain management guidelines should be prioritized.


Assuntos
Hospitais , Papel do Profissional de Enfermagem , Enfermeiras e Enfermeiros , Manejo da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/terapia , Adulto , Estudos Transversais , Análise Fatorial , Feminino , Humanos , Masculino , Manejo da Dor/métodos , Medição da Dor , Assistência ao Paciente/métodos , Assistência ao Paciente/normas , Padrões de Prática em Enfermagem , Vietnã
4.
J Clin Exp Dent ; 16(6): e678-e684, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39130359

RESUMO

Background: Different restoration materials have different optical characteristics that influence the intraoral scanner's (IOS) image accuracy. The purpose of this in-vitro investigation was to investigate how composite translucency affected the accuracy of IOS. Material and Methods: GC G-aenial Universal Injectable JE composite plates were used for the study at 3 thicknesses (1-2-3mm). A lab scanner (3Shape E1) obtained 1 reference scan, whereas IOS (Trios3) was used to conduct 10 experimental scans per group. After 3D superimposition, deviation values were used to assess the accuracy (trueness and precision) outcomes for the corresponding groups. Using an LS170 V2.0 colorimeter, the translucency parameter (TP) of the plates was determined from L*a*b* values of CIELAB color space. Results: The composite translucency resulted in a decrease in the scale of digital impressions. The 1mm group had the largest scale reduction (0.02mm) significantly, followed by the 2mm and 3mm groups (0.01mm). No difference was found in mean precision. The colorimeter detects the L*a*b* values and showed that 1mm composite plate expressed the highest TP value, then 2mm and 3mm groups (28.90, 14.26 and 6.49 respectively). The thinner composite, the higher translucency and TP were highly positively correlated to IOS trueness of composite plates. Conclusions: Composite translucency has an impact on optical impression accuracy. In correlation, the optical impression becomes less accurate the more translucent the composite is. This implies that in the digital process, the dentist should specify the appropriate optical properties of composite materials concerning both their mechanical and aesthetic qualities. Key words:Accuracy, translucency, resin composite, digital dentistry, intraoral-scanner.

5.
Environ Pollut ; 307: 119578, 2022 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-35688388

RESUMO

Long-term exposure to fine particles (PM2.5), ultrafine particles (UFPs), and volatile organic compounds (VOCs) emissions from cooking has been linked to adverse human health effects. Here, we measured the real-time number size distribution of particles emitted when cooking two served food in Chinese restaurants and estimated the emission rate of UFPs and PM2.5. Experiments were conducted under a control hood, and both online measurement and offline analysis of PM2.5 were carried out. The measured emission rates of PM2.5 generated from deep-frying and grilling were 0.68 ± 0.11 mg/min and 1.58 ± 0.25 mg/min, respectively. Moreover, the UFPs emission rate of deep-frying (4.3 × 109 #/min) is three times higher than that of grilling (1.4 × 109 #/min). Additionally, the PM2.5 emission of deep-frying was comprised of a considerable amount of α-Fe2O3 (5.7% of PM2.5 total mass), which is more toxic than other iron oxide species. A total of six carcinogenic HAPs were detected, among which formaldehyde, acrolein, and acetaldehyde were found to exceed the inhalation reference concentration (RfC) for both cooking methods. These findings can contribute to future evaluation of single particle and HAPs emission from cooking to better support toxicity assessment.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Nanopartículas , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , China , Culinária/métodos , Monitoramento Ambiental/métodos , Humanos , Ferro/análise , Nanopartículas/análise , Tamanho da Partícula , Material Particulado/análise , Restaurantes
6.
Artigo em Inglês | MEDLINE | ID: mdl-36429850

RESUMO

Volatile organic compounds (VOCs) emitted to the atmosphere form ozone and secondary organic aerosols (SOA) by photochemical reactions. As they contain numerous harmful compounds such as carcinogens, it is necessary to analyze them from a health perspective. Given the petroleum-based organic solvents used during the drying process, large amounts of VOCs are emitted from small laundry facilities. In this study, a laundry facility located in a residential area was selected, while VOCs data emitted during the drying process were collected and analyzed using a thermal desorption-gas chromatography/mass spectrometer (TD-GC/MS). We compared the results of the solvent composition, human risk assessment, contribution of photochemical ozone creation potential (POCP), and secondary organic aerosol formation potential (SOAP) to evaluate the chemical species. Alkane-based compounds; the main components of petroleum organic solvents, were dominant. The differences in evaporation with respect to the boiling point were also discerned. The POCP contribution exhibited the same trend as the emission concentration ratios for nonane (41%), decane (34%), and undecane (14%). However, the SOAP contribution accounted for o-xylene (28%), decane (27%), undecane (25%), and nonane (9%), thus confirming the high contribution of o-xylene to SOA formation. The risk assessment showed that acrylonitrile, carbon tetrachloride, nitrobenzene, bromodichloromethane, and chloromethane among carcinogenic compounds, and bromomethane, chlorobenzene, o-xylene, and hexachloro-1, 3-butadiene were found to be hazardous, thereby excessing the standard value. Overall these results facilitate the selection and control of highly reactive and harmful VOCs emitted from the dry-cleaning process.


Assuntos
Poluentes Atmosféricos , Ozônio , Petróleo , Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Ozônio/análise , Poluentes Atmosféricos/análise , Aerossóis/análise , Medição de Risco , Solventes , Petróleo/análise
7.
Nanomaterials (Basel) ; 11(6)2021 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-34072737

RESUMO

The lacking of laboratory black carbon (BC) samples have long challenged the corresponding toxicological research; furthermore, the toxicity tests of engineered carbon nanoparticles were unable to reflect atmospheric BC. As a simplified approach, we have synthesized artificial BC (aBC) for the purpose of representing atmospheric BC. Surface chemical properties of aBC were controlled by thermal treatment, without transforming its physical characteristics; thus, we were able to examine the toxicological effects on A549 human lung cells arising from aBC with varying oxidation surface properties. X-ray photoelectron spectroscopy, as well as Raman and Fourier transform infrared spectroscopy, verified the presence of increased amounts of oxygenated functional groups on the surface of thermally-treated aBC, indicating aBC oxidization at elevated temperatures; aBC with increased oxygen functional group content displayed increased toxicity to A549 cells, specifically by decreasing cell viability to 45% and elevating reactive oxygen species levels up to 294% for samples treated at 800 °C.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA