Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Aerosol Med Pulm Drug Deliv ; 36(4): 154-161, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37256713

RESUMO

Background: In the critically ill, pulmonary vasodilators are often provided off label to intubated patients using continuous nebulization. If additional aerosol therapies such as bronchodilators or antibiotics are needed, vasodilator therapy may be interrupted. This study assesses aerosol systems designed for simultaneous delivery of two aerosols using continuous nebulization and bolus injection without interruption or circuit disconnection. Methods: One i-AIRE dual-port breath-enhanced jet nebulizer (BEJN) or two Aerogen® Solo vibrating mesh nebulizers (VMNs) were installed on the dry side of the humidifier. VMN were stacked; one for infusion and the second for bolus drug delivery. The BEJN was powered by air at 3.5 L/min, 50 psig. Radiolabeled saline was infused at 5 and 10 mL/h with radiolabeled 3 and 6 mL bolus injections at 30 and 120 minutes, respectively. Two adult breathing patterns (duty cycle 0.13 and 0.34) were tested with an infusion time of 4 hours. Inhaled mass (IM) expressed as % of initial syringe activity (IM%/min) was monitored in real time with a ratemeter. All delivered radioaerosol was collected on a filter at the airway opening. Transients in aerosol delivery were measured by calibrated ratemeter. Results: IM%/h during continuous infusion was linear and predictable, mean ± standard deviation (SD): 2.12 ± 1.45%/h, 2.47 ± 0.863%/h for BEJN and VMN, respectively. BEJN functioned without incident. VMN continuous aerosol delivery stopped spontaneously in 3 of 8 runs (38%); bolus delivery stopped spontaneously in 3 of 16 runs (19%). Tapping restarted VMN function during continuous and bolus delivery runs. Bolus delivery IM% (mean ± SD): 20.90% ± 7.01%, 30.40% ± 11.10% for BEJN and VMN, respectively. Conclusion: Simultaneous continuous and bolus nebulization without circuit disconnection is possible for both jet and mesh technology. Monitoring of VMN devices may be necessary in case of spontaneous interruption of nebulization.


Assuntos
Albuterol , Respiração Artificial , Adulto , Humanos , Administração por Inalação , Aerossóis , Nebulizadores e Vaporizadores , Broncodilatadores , Sistemas de Liberação de Medicamentos , Desenho de Equipamento
2.
Respir Care ; 67(8): 914-928, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35640996

RESUMO

BACKGROUND: Recent observational studies of nebulizers placed on the wet side of the humidifier suggest that, after some time, considerable condensation can form, which triggers an occlusion alarm. In the current study, an inline breath-enhanced jet nebulizer was tested and compared in vitro with a vibrating mesh nebulizer on the humidifier dry-inlet side of the ventilator circuit. METHODS: Two duty cycle breathing patterns were tested during continuous infusion (5 or 10 mL/h) with and without dynamic changes in infusion flow and duty cycle, or bolus delivery (3 or 6 mL) of radiolabeled saline solution. Inhaled mass (IM) was measured by a real-time ratemeter (µCi/min) and analyzed by multiple linear regression. RESULTS: During simple continuous infusion, IM increased linearly for both nebulizer types. IM variability was attributable to the duty cycle (P < .001) (34%) and infusion flow (P < .001) (32%) but independent of nebulizer technology (P = .38) (7%). Dynamic continuous infusion studies that simulate clinical scenarios with ventilator and pump flow changes demonstrated a linear increase in the rate of aerosol that was dependent on pump flow (P < .001) (63%) and minimally dependent on the duty cycle (P = .003) (8%). During bolus treatments, IM increased linearly to plateau. IM variability was attributable to the duty cycle (P < .001) (40%) and residual radioactivity in the nebulizer (P < .001) (20%). Separate analysis revealed that the vibrating mesh nebulizer residual volume contributed 16% of the variability and inline breath-enhanced jet nebulizer contributed 5%. IM variability was independent of bolus volume (P = .82) (1%). System losses were similar (the inline breath-enhanced jet nebulizer: 32% residual in nebulizer; the vibrating mesh nebulizer: 34% in circuitry). CONCLUSIONS: Aerosol delivery during continuous infusion and bolus delivery was comparable between the inline breath-enhanced jet nebulizer and the vibrating mesh nebulizer, and was determined by pump flow and initial ventilator settings. Further adjustments in ventilator settings did not significantly affect drug delivery. Expiratory losses predicted by the duty cycle were reduced with placement of the nebulizer near the ventilator outlet.


Assuntos
Albuterol , Respiração Artificial , Administração por Inalação , Aerossóis , Broncodilatadores , Sistemas de Liberação de Medicamentos , Desenho de Equipamento , Humanos , Nebulizadores e Vaporizadores
3.
J Aerosol Med Pulm Drug Deliv ; 35(1): 32-40, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34227873

RESUMO

Background: A new real-time method for assessing factors determining aerosol delivery is described. Methods: A breath-enhanced jet nebulizer operated in a ventilator/heated humidifier system was tested during bolus and continuous infusion aerosol delivery. 99mTc (technetium)/saline was either injected (3 or 6 mL) or infused over time into the nebulizer. A shielded gamma ratemeter was oriented to count radioaerosol accumulating on an inhaled mass (IM) filter at the airway opening of a test lung. Radioactivity measured at 2-10-minute intervals was expressed as % nebulizer charge (bolus) or % syringe activity per minute infused. All circuit parts were measured and imaged by gamma camera to determine mass balance. Results: Ratemeter activity quantitatively reflected immediate changes in IM: 3 and 6 mL bolus IM% = 16.1 and 18.8% in 6 and 14 minutes, respectively; infusion IM% = 0.64 + 0.13 (run time, min), R2 0.999. Effect of nebulizer priming and system anomalies were readily detected in real time. Mass balance (basis = dose infused in 90 minutes): IM 39.2%, breath-enhanced jet nebulizer residual 35.5%, circuit parts including humidifier 23.4%, and total recovery 98.1%. Visual analysis of circuit component images identified sites of increased deposition. Conclusion: Real-time ratemeter measurement with gamma camera imaging provides operational feedback during in vitro testing procedures and yields a detailed analysis of the parameters influencing drug delivery during mechanical ventilation. This method of analysis facilitates assessment of device function and influence of circuit parameters on drug delivery.


Assuntos
Albuterol , Respiração Artificial , Administração por Inalação , Aerossóis , Broncodilatadores , Sistemas de Liberação de Medicamentos , Desenho de Equipamento , Nebulizadores e Vaporizadores , Respiração Artificial/métodos
4.
Biochemistry ; 48(37): 8806-16, 2009 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-19655782

RESUMO

The presence of metallothionein in seaweed Fucus vesiculosus has been suggested as the protecting agent against toxic metals in the contaminated waters it can grow in. We report the first kinetic pathway data for A3+ binding to an algal metallothionein, F. vesiculosus metallothionein (rfMT). The time and temperature dependence of the relative concentrations of apo-rfMT and the five As-containing species have been determined following mixing of As3+ and apo-rfMT using electrospray ionization mass spectrometry (ESI MS). Kinetic analysis of the detailed time-resolved mass spectral data for As3+ metalation allows the simulation of the metalation reactions showing the consumption of apo-rfMT, the formation and consumption of As1- to As4-rfMT, and subsequent, final formation of As5-rfMT. The kinetic model proposed here provides a stepwise analysis of the metalation reaction showing time-resolved occupancy of the Cys7 and the Cys9 domain. The rate constants (M(-1) s(-1)) calculated from the fits for the 7-cysteine gamma domain are k1gamma, 19.8, and k2gamma, 1.4, and for the 9-cysteine beta domain are k1beta, 16.3, k2beta, 9.1, and k3beta, 2.2. The activation energies and Arrhenius factors for each of the reaction steps are also reported. rfMT has a long 14 residue linker, which as we show from analysis of the ESI MS data, allows each of its two domains to bind As3+ independently of each other. The analysis provides for the first time an explanation of the differing metal-binding properties of two-domain MTs with linkers of varying lengths, suggesting further comparison between plant (with long linkers) and mammalian (with short linkers) metallothioneins will shed light on the role of the interdomain linker.


Assuntos
Proteínas de Algas/química , Arsênio/química , Arsênio/metabolismo , Fucus/química , Metalotioneína/química , Metalotioneína/metabolismo , Proteínas de Algas/metabolismo , Sequência de Aminoácidos , Arsênio/toxicidade , Fucus/efeitos dos fármacos , Fucus/metabolismo , Cinética , Dados de Sequência Molecular , Ligação Proteica , Estrutura Terciária de Proteína , Proteínas Recombinantes/química , Proteínas Recombinantes/metabolismo , Espectrometria de Massas por Ionização por Electrospray
5.
J Inorg Biochem ; 104(3): 232-44, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20079542

RESUMO

Metallothionein (MT) is a prominent metal-binding protein and in mammalian systems contains a two-domain betaalpha motif, while in lower life forms MT often consists of only a single-domain structure. There are also unusual MTs from American oysters that consist of multiple domains (from one to four alpha domains). This report details the study of the As(3+)-metalation to two different concatenated triple beta and alpha domain MTs using time-resolved electrospray ionization mass spectrometry (ESI MS). Analysis of kinetic ESI MS data show that alphaalphaalpha human MT and betabetabeta human MT bind As(3+) in a noncooperative manner and involves up to 11 sequential bimolecular reactions. We report the complete progress of the reactions for the As(3+)-metalation of both triple-domain MTs from zero and up to 9 (betabetabeta) or 10As(3+) ions (alphaalphaalpha). The rate constants for the As(3+)-metalation are reported for both the betabetabeta and alphaalphaalpha human MT. At room temperature (298K) and pH3.5, the sequential individual rate constants, k(n) (n=1-9) for the As(3+)-metalation of betabetabetahMT starting at k(1betabetabeta) are 40, 36, 37, 26, 27, 17, 12, 6, and 1M(-1)s(-1); while at room temperature (298K) and pH3.5, the sequential individual rate constants, k(n) (n=1-10) for the As(3+)-metalation of alphaalphaalphahMT starting at k(1alphaalphaalpha) are 52, 45, 46, 42, 38, 36, 29, 25, 14, and 6M(-1)s(-1). The trend in the rate constant values reported for these two triple-domain MT proteins supports our previous proposal that the rate constant values are proportionally related to the total number of equivalent binding sites. The rate of binding for the 1st As(3+) is the fastest we have determined for any MT to date. Additionally, we propose that the data show for the first time for any MT species, that interdomain metalation occurs in the binding of the 10th and 11th As(3+) to alphaalphaalphahMT.


Assuntos
Arsênio/metabolismo , Metalotioneína/química , Metalotioneína/metabolismo , Conformação Proteica , Sequência de Aminoácidos , Animais , Arsênio/química , Sítios de Ligação , Evolução Biológica , Humanos , Metalotioneína/genética , Dados de Sequência Molecular , Ligação Proteica , Espectrometria de Massas por Ionização por Electrospray
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA