1.
Sensors (Basel) ; 21(15)2021 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-34372487

RESUMO

An innovative smart concrete anchorage (SCA) has been developed for monitoring the stress of prestressing (PS) tendons by utilizing smart ultra-high-performance concrete (UHPC). The smart UHPC contained 2 vol% steel fibers and fine steel slag aggregates instead of silica sands. The effects of different electrode materials, arrangements, and connectors on the self-stress sensing capacity of the SCA are discussed. A prototype SCA demonstrated its feasibility and sufficient self-stress sensing capacity to be used in monitoring the prestressing loss of the PS tendon. As the tensile stress of the PS tendon increased from 0 to 1488 MPa, the fractional change in resistivity (FCR) of the prototype SCA, with horizontally paired copper wire electrodes and a plug-in type connector, decreased linearly from 0% to -1.53%, whereas the FCR increased linearly from -1.53% to -0.04% as the tensile stress of the PS tendon decreased from 1488 to 331 MPa.


Assuntos
Materiais de Construção , Aço , Dióxido de Silício , Tendões