Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Arch Orthop Trauma Surg ; 144(4): 1781-1792, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38147077

RESUMO

BACKGROUND: Positioning implant components and restoring patient anatomy during total hip arthroplasty (THA) are essential for joint stability, polyethylene liner wear, and range of motion. Previous studies comparing intraoperative fluoroscopy with no fluoroscopy during the posterior or posterolateral approach have reported conflicting results. This meta-analysis evaluated if intraoperative fluoroscopy improves component positioning and femoral component position compared to no fluoroscopy during posterior or posterolateral approach total hip arthroplasty. METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses standards were followed when conducting the systematic review. We searched Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in May 2023 to identify studies involving Intraoperative fluoroscopy versus no fluoroscopy during posterior or posterolateral approach total hip arthroplasty. Finally, we identified 1133 patients (1145 hips) assessed in seven studies. RESULTS: There were no significant differences in terms of acetabular cup inclination angle (ACIA, P = 0.43), ACIA within safe zone rate (P = 0.58), acetabular cup anteversion angle (ACAA, P = 0.46); ACAA within safe zone rate (P = 0.72), Combined safe zone rate (P = 0.28), dislocation rate (P = 0.64) and infection rate (P = 0.94) between two groups. Compared with the no fluoroscopy group, the intraoperative fluoroscopy group had more operation time (P < 0.00001), less femoral component offset difference (FCOD, P = 0.03), and less LLD (P < 0.00001). CONCLUSION: Even though intraoperative fluoroscopy was not related to an improvement in cup location or dislocation incidence. Our findings demonstrate that the restoration of leg lengths and femoral offset can be significantly improved by using intraoperative fluoroscopy to supplement good surgical skills in THA. The advantages of intraoperative fluoroscopy might become more apparent for surgeons with less experience. To ascertain whether intraoperative fluoroscopy for posterior or posterolateral approach total hip arthroplasty will have clinical benefits and improve the survival of prostheses, more well-powered and well-designed long-term follow-up studies were necessary.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Luxações Articulares , Humanos , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Acetábulo/cirurgia , Fluoroscopia/métodos , Luxações Articulares/cirurgia
2.
J Orthop Surg Res ; 18(1): 586, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37553600

RESUMO

BACKGROUND: The positioning of implant components for total hip arthroplasty (THA) is essential for joint stability, polyethylene liner wear, and range of motion. One potential benefit of the direct anterior approach (DAA) for THA is the ability to use intraoperative fluoroscopy for acetabular cup positioning and limb-length evaluation. Previous studies comparing intraoperative fluoroscopy with no fluoroscopy during DAA have reported conflicting results. This meta-analysis aimed to evaluate whether intraoperative fluoroscopy improves component positioning compared to no fluoroscopy during direct anterior total hip arthroplasty. METHODS: A systematic review following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines was conducted. We searched Web of Science, EMBASE, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in May 2023 to identify studies involving intraoperative fluoroscopy versus no fluoroscopy during direct anterior total hip arthroplasty. Finally, we identified 1262 hips assessed in seven studies. RESULTS: There were no significant differences in terms of acetabular cup inclination angle (ACIA, P = 0.21), ACIA within safe zone rate (P = 0.97), acetabular cup anteversion angle (ACAA, P = 0.26); ACAA within safe zone rate (P = 0.07), combined safe zone rate (P = 0.33), and limb-length discrepancy (LLD, P = 0.21) between two groups. CONCLUSION: Even though intraoperative fluoroscopy was not related to an improvement in cup location or LDD. With fewer experienced surgeons, the benefit of intraoperative fluoroscopy might become more evident. More adequately powered and well-designed long-term follow-up studies were required to determine whether the application of the intraoperative fluoroscopy for direct anterior total hip arthroplasty will have clinical benefits and improve the survival of prostheses.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Articulação do Quadril/cirurgia , Estudos Retrospectivos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia
3.
J Orthop Surg Res ; 17(1): 243, 2022 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-35440065

RESUMO

BACKGROUND: Despite Vast improvements in technology and surgical technique in total knee arthroplasty (TKA), approximately 15-25% TKAs, have suboptimal subjective clinical outcomes. Our study sought to evaluate if sensor-guided balancing improves postoperative clinical outcomes compared to a conventional gap balancing technique. METHODS: We searched Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database in March 2022 to identify studies involving sensor-guided balancing versus conventional gap balancing technique in TKA. Finally, we identified 2147 knees assessed in nine studies. RESULTS: Compared with manual gap balancing, Sensor-guided gap balancing resulted in less rate of Manipulation under anesthesia (MUA) (P = 0.02), however more rate of intraoperative additional procedures (P = 0.0003). There were no significant differences in terms of KSS (P = 0.21), KSS Function score (P = 0.36), OKS (P = 0.61), KOOS (P = 0.78), operative time (P = 0.17), Mechanical axis (P = 0.69) and rate of reoperation between two groups. CONCLUSION: Compared with conventional manual gap balancing techniques, sensors have more balancing procedures being performed. However, it did result in a reduction in the rate of MUA. More extensive, high-quality RCTs are required to verify our findings further.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Artroplastia do Joelho/métodos , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular
4.
J Orthop Surg Res ; 15(1): 297, 2020 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-32758250

RESUMO

BACKGROUND: The infrapatellar fat pad (IPFP) or Hoffa's fat pad is often resected during total knee arthroplasty in order to improve visibility. However, the management of the IPFP during total knee arthroplasty (TKA) is the subject of an ongoing debate that has no clear consensus. The purpose of this review was to appraise if resection of the IPFP affects clinical outcomes. METHODS: We conducted a meta-analysis to identify relevant randomized controlled trials involving infrapatellar fat pad resection and infrapatellar fat pad preservation during total knee arthroplasty in electronic databases, including Web of Science, Embase, PubMed, Cochrane Controlled Trials Register, Cochrane Library, Highwire, CBM, CNKI, VIP, and Wanfang database, up to March 2020. RESULTS: Nine randomized controlled trials, involving 783 TKAs (722 patients), were included in the systematic review. Outcome measures included patellar tendon length (PTL), Insall-Salvati ratio (ISR), rate of anterior knee pain, Knee Society Scores (KSS), and knee range of motion. The meta-analysis identified a trend toward the shortening of the patellar tendon with IPFP resection at 6 months (P = 0.0001) and 1 year (P = 0.001). We found no statistical difference in ISR (P = 0.87), rate of anterior knee pain within 6 months (p = 0.45) and 1 year (p = 0.38), KSS at 1 year (p = 0.77), and knee range of motion within 6 months (p = 0.61) and 1 year (0.46). CONCLUSION: Based on the available level I evidence, we were unable to conclude that one surgical technique of IPFP can definitively be considered superior over the other. More adequately powered and better-designed randomized controlled trial (RCT) studies with long-term follow-up are required to produce evidence-based guidelines regarding IPFP resection.


Assuntos
Tecido Adiposo/cirurgia , Artroplastia do Joelho/métodos , Patela/cirurgia , Idoso , Feminino , Humanos , Articulação do Joelho/patologia , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Dor Pós-Operatória/epidemiologia , Ligamento Patelar/patologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Amplitude de Movimento Articular , Preservação de Tecido
5.
J Clin Anesth ; 33: 75-80, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27555137

RESUMO

STUDY OBJECTIVES: To compare the anesthetic potency and safety of spinal anesthesia with higher dosages of levobupivacaine and bupivacaine in patients for bilateral sequential for total knee arthroplasty (TKA). DESIGN: Retrospective cohort study. SETTING: Operation theater with postoperative inpatient follow-up. PATIENTS: The medical records of 315 patients who underwent sequential bilateral TKA were reviewed. INTERVENTIONS: Patients who received intrathecal levobupicavaine 0.5% were compared with patients who received hyperbaric bupivacaine 0.5% with fentanyl 25 µg for spinal anesthesia. MEASUREMENTS: The primary outcome was the use of rescue analgesia (systemic opioids, conversion to general anesthesia) during surgery for both groups. Secondary outcomes included adverse effects of local anesthetics (hypotension and bradycardia) during surgery and morbidity related to spinal anesthesia (postoperative nausea, vomiting, and bleeding) during hospital stay. MAIN RESULTS: One hundred fifty patients who received intrathecal levobupivacaine 0.5% (group L) were compared with 90 patients given hyperbaric bupivacaine 0.5% with fentanyl 25 µg (group B). The mean volume of levobupivacaine administered was 5.8 mL (range, 5.0-6.0 mL), and that of bupivacaine was 3.8 mL (range, 3.5-4.0 mL). Both groups achieved similar maximal sensory level of block (T6). The time to maximal height of sensory block was significantly shorter in group B than group L, 18.2 ± 4.5 vs 23.9 ± 3.8 minutes (P< .001). The time to motor block of Bromage 3 was also shorter in group B (8.7 ± 4.1 minutes) than group L (16.0 ± 4.5 minutes) (P< .001). Patients in group B required more anesthetic supplement than group L (P< .001). Hypotension and postoperative bleeding were significantly less common in group L than group B. CONCLUSION: Levobupivacaine at a higher dosage provided longer duration of spinal anesthesia with better safety profile in sequential bilateral TKA.


Assuntos
Raquianestesia/métodos , Anestésicos Locais/administração & dosagem , Artroplastia do Joelho/métodos , Bupivacaína/análogos & derivados , Bupivacaína/administração & dosagem , Idoso , Raquianestesia/efeitos adversos , Anestésicos Locais/efeitos adversos , Bupivacaína/efeitos adversos , Esquema de Medicação , Feminino , Humanos , Período Intraoperatório , Levobupivacaína , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA