Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Rapid Commun Mass Spectrom ; 33(24): 1906-1914, 2019 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-31323696

RESUMO

RATIONALE: We developed a new high-throughput method to analyze tegafur (FT) and 5-fluorouracil (5-FU) in tear and plasma samples using hydrophilic interaction liquid chromatography (HILIC)/tandem mass spectrometry (MS/MS). METHODS: The tear samples (10 µL) spiked with FT, 5-FU, and 5-chlorouracil (internal standard) were diluted using 40 µL of 2 M ammonium acetate and 250 µL of acetonitrile with 2% formic acid; 20 µL of plasma spiked with the two drugs and internal standard was diluted with 80 µL of 2 M ammonium acetate and 500 µL of acetonitrile with 2% formic acid. After centrifugation, the clear supernatant extract (15 µL) was directly injected into the HILIC/MS/MS instrument, and each drug was separated on a Unison UK-Amino column (50 mm × 3 mm i.d., 3 µm particle size) with a linear gradient elution system composed of 10 mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.7 mL/min. We performed quantification by multiple reaction monitoring (MRM) with negative-ion atmospheric-pressure chemical ionization. RESULTS: Distinct peaks were observed for the drugs on each MRM channel within 2 min. The regression equations showed good linearity within the range 0.04-4.0 µg/mL for the tear and plasma samples with detection limits at 0.02-0.04 µg/mL. Recoveries for target analytes (FT and 5-FU) for the tear and plasma samples were in the 94-128% and 94-104% ranges, respectively. The intra- and inter-day coefficients of variation for the two drugs were lower than 10.8%. The accuracies of quantitation were 97-115% for both samples. CONCLUSIONS: We established a high-throughput, reproducible, and practical procedure for analyzing FT and 5-FU in human tear and plasma samples using HILIC/MS/MS analysis with an aminopropyl-bonded mixed-mode separation column. This method can be applied to the high-throughput routines used in clinical analyses.


Assuntos
Fluoruracila/análise , Lágrimas/química , Tegafur/análise , Idoso , Cromatografia Líquida de Alta Pressão , Feminino , Fluoruracila/sangue , Humanos , Interações Hidrofóbicas e Hidrofílicas , Limite de Detecção , Masculino , Espectrometria de Massas em Tandem , Tegafur/sangue
2.
J Sep Sci ; 35(5-6): 726-33, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22271670

RESUMO

A novel method is described for the extraction of methamphetamine, amphetamine, and methylenedioxyphenylalkylamine designer drugs, such as 3,4-methylenedioxy-methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxyethylamphetamine, N-methyl-1-(3,4-methylenedioxyphenyl)-2-butanamine, and 3,4-(methylenedioxyphenyl)-2-butanamine, from human whole blood using molecularly imprinted solid-phase extraction as highly selective sample clean-up technique. Whole blood samples were diluted with 10 mmol/L ammonium acetate (pH 8.6) and applied to a SupelMIP-Amphetamine molecularly imprinted solid-phase extraction cartridge. The cartridge was then washed to eliminate interferences, and the amphetamines of interest were eluted with formic acid/methanol (1:100, v/v). After derivatization with trifluoroacetic anhydride, the analytes were quantified using gas chromatography-mass spectrometry. Recoveries of the seven amphetamines spiked into whole blood were 89.1-102%. The limits of quantification for each compound in 200 µL of whole blood were between 0.25 and 1.0 ng. The maximum intra- and inter-day coefficients of variation were 9.96 and 13.8%, respectively. The results show that methamphetamine, amphetamine, and methylenedioxyphenylalkyl-amine designer drugs can be efficiently extracted from crude biological samples such as whole blood by molecularly imprinted solid-phase extraction with good reproducibility. This extraction method will be useful for the pretreatment of human samples before gas chromatography-mass spectrometry.


Assuntos
Anfetamina/isolamento & purificação , Anfetaminas/isolamento & purificação , Drogas Desenhadas/isolamento & purificação , Polímeros/química , Extração em Fase Sólida/métodos , 3,4-Metilenodioxianfetamina/análogos & derivados , 3,4-Metilenodioxianfetamina/sangue , 3,4-Metilenodioxianfetamina/isolamento & purificação , Adsorção , Anfetamina/sangue , Anfetaminas/sangue , Drogas Desenhadas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Impressão Molecular , Polímeros/síntese química , Extração em Fase Sólida/instrumentação
3.
Anal Bioanal Chem ; 401(7): 2215-23, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21874269

RESUMO

Dextromethorphan was extracted from human plasma samples (100 µL) using MonoTip C(18) tips, which are packed with C(18)-bonded monolithic silica gel that is attached to the inside of the tip. The samples, which contained dextromethorphan and trimeprazine as an internal standard (IS), were mixed with 200 µL of distilled water and 50 µL of 1 mol/L glycine-sodium hydroxide buffer (pH 10). The mixture was extracted to the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.5 µm) gave adequate separation of the dextromethorphan, IS, and impurities. The recoveries of dextromethorphan and the IS spiked into plasma were >87.4%. The regression equation for dextromethorphan showed excellent linearity from 2.5 to 320 ng/mL of plasma, and the limit of detection was 1.25 ng/mL of plasma. The intraday and interday coefficients of variation were less than 10.5% and 14.7%, respectively. The accuracy ranged from 91.9% to 107%. The validated method was successfully used to quantify the plasma concentration of dextromethorphan in a human subject after oral administration of the drug.


Assuntos
Dextrometorfano/sangue , Antagonistas de Aminoácidos Excitatórios/sangue , Cromatografia Gasosa-Espectrometria de Massas , Extração em Fase Sólida , Administração Oral , Dextrometorfano/administração & dosagem , Antagonistas de Aminoácidos Excitatórios/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Sensibilidade e Especificidade
4.
J Ethnopharmacol ; 276: 114218, 2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34029638

RESUMO

ETHNOPHARMACOLOGICAL RELEVANCE: Kamikihito (KKT) is a Kampo medicine that is prescribed in Japan for the treatment of anemia, insomnia and mental anxiety in Japan. However, its precise mechanism of action remains unclear. AIM OF THE STUDY: This study aimed to evaluate the possible antistress effect of KKT in rats with acute stress and the contribution of oxytocin to the process. MATERIALS AND METHODS: Acute immobilization stress (AIS; for 90 min) was used to assess the effect of KKT on acute stress. Male Wistar rats were orally treated with KKT. Parameters of stress were evaluated, and concentrations of oxytocin in plasma and cerebrospinal fluid (CSF) were measured. RESULTS: AIS-induced defecation and fecal weight were significantly decreased because of treatment with KKT. The plasma levels of stress-related hormones following AIS were investigated. The pre-administration of KKT significantly increased adrenocorticotrophic hormone (ACTH) and corticosterone (CORT) levels following AIS. Conversely, there was no significant change in the plasma oxytocin level. Microdialysis and hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-MS/MS) were used to monitor the oxytocin secretion in CSF. Oxytocin level increased during AIS following the treatment of KKT. At 30 min after AIS, the level remained higher than before AIS. Furthermore, using an open field test, the locomotion (exploratory behavior) immediately after AIS was examined. The total traveled distance decreased after AIS; however, the decrease was significantly inhibited by the treatment of KKT. However, the effect of KKT was obstructed by the pre-administration of the oxytocin receptor antagonist. CONCLUSIONS: These results suggest that KKT has antistress activity and increased oxytocin secretion may be a mechanism underlying this phenomenon.


Assuntos
Medicamentos de Ervas Chinesas/farmacologia , Ocitocina/líquido cefalorraquidiano , Estresse Fisiológico/efeitos dos fármacos , Administração Oral , Hormônio Adrenocorticotrópico/sangue , Animais , Comportamento Animal/efeitos dos fármacos , Corticosterona/sangue , Defecação/efeitos dos fármacos , Modelos Animais de Doenças , Medicamentos de Ervas Chinesas/administração & dosagem , Locomoção/efeitos dos fármacos , Masculino , Medicina Kampo/métodos , Núcleo Hipotalâmico Paraventricular/metabolismo , Núcleo Hipotalâmico Paraventricular/ultraestrutura , Ratos Wistar , Restrição Física/efeitos adversos
5.
Eur J Mass Spectrom (Chichester) ; 27(1): 63-70, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33745337

RESUMO

Aminoglycosides are a class of broad-spectrum antibiotics with several clinical uses. Owing to the ototoxicity and nephrotoxicity of aminoglycosides, therapeutic drug monitoring is required. This study aimed to devise a high-throughput method for identification and quantitative determination of aminoglycoside antibiotics in human plasma samples using ultra-performance liquid chromatography-quadrupole time-of-flight-mass spectrometry (UPLC-Q-ToF-MS). Plasma samples (100 µL) spiked with five aminoglycosides (streptomycin, spectinomycin, amikacin, kanamycin, and gentamycin) and an internal standard (ribostamycin) were diluted and centrifuged in aqueous formic acid and acetonitrile. The clear supernatant extract was evaporated and reconstituted in the mobile phase, of which 4 µL was subjected to UPLC-Q-ToF-MS. Prominent peaks were observed for the drugs within 3 min. The recoveries of five aminoglycosides from plasma samples were 92.6-120%. The regression equations showed excellent linearity (0.9999 ≥ r2 ≥ 0.9987) within the range of 1.0-100 µg/mL, and detection limits of 0.5-2.0 µg/mL. The coefficients of the intra- and inter-day variations for five drugs were less than 11.8%, while the accuracy of quantitation was in the range of 89-111%. In this study, a novel method was presented for identification and determination of aminoglycosides in human plasma samples using UPLC-Q-ToF-MS analysis. This method can be applied to high-throughput analysis used for clinical and environmental purposes.


Assuntos
Preparações Farmacêuticas , Espectrometria de Massas em Tandem , Aminoglicosídeos , Antibacterianos , Cromatografia Líquida de Alta Pressão , Humanos
6.
Hemodial Int ; 23(4): 466-471, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31328884

RESUMO

INTRODUCTION: The potential utility of intravenous alendronate for the treatment of osteoporosis in hemodialysis patients was recently reported. However, the pharmacokinetics of intravenous alendronate in patients on hemodialysis is not clear. METHODS: Six hemodialysis patients (mean age, 80.5 years) with osteoporosis who had received intravenous alendronate prior to the study were enrolled. The participants received a 30-min infusion of 900-µg alendronate intravenously at the beginning of the dialysis session. The blood flow rate (Qb) and dialysate flow rate (Qd) were set at 200 mL/min and 500 mL/min, respectively. All patients used the same dialyzer (1.5-m2 polysulfone membrane). At the completion of administration, plasma and dialysate samples were collected, and alendronate concentrations were determined using metal-free high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS). RESULTS: The plasma arterial alendronate concentration was 150.9 ± 46.09 ng/mL. It decreased through the dialyzer to 76.1 ± 34.1 ng/mL (venous alendronate concentration). Mean alendronate clearance was 113.9 ± 25.6 mL/min. Mean alendronate removal by hemodialysis, measured by the difference in arterial-venous concentrations, was 51.8%. CONCLUSIONS: Fifty percent of intravenous alendronate was removed by hemodialysis, which is nearly equal to elimination of alendronate in patients with normal renal function. The elimination by hemodialysis would decrease the risk of excessive accumulation in bone. UMIN 000027182.


Assuntos
Alendronato/metabolismo , Soluções para Diálise/química , Diálise Renal/métodos , Administração Intravenosa , Idoso de 80 Anos ou mais , Alendronato/farmacologia , Feminino , Humanos , Masculino
7.
J Sep Sci ; 31(12): 2265-71, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18546392

RESUMO

A method for the simultaneous extraction of four tricyclic antidepressants from human plasma samples using pipette tip SPE with MonoTip C(18) tips is presented. Human plasma (0.1 mL) containing four tricyclic antidepressants (amitriptyline, amoxapine, imipramine, and trimipramine) and an internal standard (IS), protriptyline, was mixed with 0.4 mL of distilled water and 100 microL 1 M NaOH solution. After centrifugation of the mixture, the supernatant was extracted to the C(18) phase of the tip by 20 repeated aspirating/dispensing cycles using a manual micropipettor. The analytes retained in the tip were eluted with methanol by five repeated aspirating/dispensing cycles. Without evaporation and reconstitution, the eluate was directly injected into a gas chromatograph injector and detected by a mass spectrometer with SIM in the positive-ion electron impact mode. Recovery of the four antidepressants and IS spiked into human plasma was 80.2-92.1%. The regression equations for the four antidepressants showed excellent linearity in the range of 0.2-40 ng/0.1 mL. LODs and LOQs for the four drugs were 0.05-0.2 ng/0.1 mL and 0.2-0.5 ng/0.1 mL, respectively. Intra- and interday CVs for the four drugs in plasma were no greater than 9.5%.


Assuntos
Antidepressivos Tricíclicos/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Extração em Fase Sólida/métodos , Amoxapina/administração & dosagem , Amoxapina/sangue , Antidepressivos Tricíclicos/administração & dosagem , Antidepressivos Tricíclicos/química , Análise Química do Sangue/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Extração em Fase Sólida/instrumentação
8.
J AOAC Int ; 91(6): 1354-62, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19202796

RESUMO

Chlorpromazine, levomepromazine, promazine, triflupromazine, and trimeprazine were simultaneously determined in human whole blood and plasma by combining headspace solid-phase microextraction and gas chromatography with nitrogen-phosphorus detection. Extraction efficiency for the phenothiazine derivatives was 0.013-0.117% for both sample types. Regression equations were linear [correlation coefficient (r) = 0.9951-0.9999] within the range 2.5-200 ng/0.5 mL for triflupromazine and trimeprazine, and 6.3-200 ng/0.5 mL for chlorpromazine, levomepromazine, and promazine. The limit of detection for each compound was 0.2-3.9 ng/0.5 mL whole blood and plasma. Intraday and interday coefficients of variation for all phenothiazines in both human samples were commonly < 15 and 20%, respectively. We also report the determination of levomepromazine in human plasma after oral administration.


Assuntos
Antipsicóticos/sangue , Fenotiazinas/sangue , Adulto , Cromatografia Gasosa , Feminino , Humanos , Indicadores e Reagentes , Nitrogênio/química , Fósforo/química , Controle de Qualidade , Padrões de Referência , Microextração em Fase Sólida
9.
Leg Med (Tokyo) ; 30: 14-20, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29127845

RESUMO

A highly sensitive method was developed for the analysis of alendronate in human plasma and dialysate using MonoSpin™ SAX® extraction and metal-free high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) following methylation with trimethylsilyldiazomethane. The chromatographic separation of the derivatives for alendronate and alendronate-d6 was achieved on an L-column2 ODS metal-free column (50 mm  ×  2 mm i.d., particle size 3 µm) with a linear gradient elution system composed of 10 mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.3 ml/min. Quantification was performed by multiple reaction monitoring (MRM) with positive-ion electrospray ionization (ESI). Distinct peaks were observed for alendronate and for the internal standard on each channel within 1 min. The regression equations showed good linearity within the ranges of 2.0-100 ng/0.5 ml for the plasma and 1.0-100 ng/0.5 ml for the dialysate, with the limits of detection at 1.0 ng/0.5 ml for the plasma and 0.5 ng/0.5 ml for the dialysate. Extraction efficiencies for alendronate for the plasma and dialysate were 41.1-51.2% and 63.6-73.4%, respectively. The coefficient of variation (CV) was ≤8.5%. The method was successfully applied to the analyses of real plasma and dialysate samples derived after intravenous administration of alendronate.


Assuntos
Alendronato/sangue , Conservadores da Densidade Óssea/sangue , Cromatografia Líquida de Alta Pressão/métodos , Soluções para Diálise/análise , Plasma/química , Espectrometria de Massas em Tandem/métodos , Diazometano/análogos & derivados , Humanos , Metais , Compostos de Trimetilsilil
10.
Leg Med (Tokyo) ; 31: 66-73, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29413992

RESUMO

A new high-throughput method was developed for analysis of valproate in human plasma samples by QuEChERS extraction and gas chromatography-tandem mass spectrometry (GC-MS/MS). Plasma samples (0.2 ml) spiked with valproate and secobarbital-d5 (internal standard) were diluted with 1.3 ml of distilled water. Acetonitrile (1 ml) was added followed by 0.4 g MgSO4 and 0.1 g NaOAC. After a centrifugation step (2000 g for 10 min), 1 ml of the supernatant was transferred to a dispersive-solid phase extraction (dSPE) tube containing 150 mg MgSO4 and 50 mg C18. This mixture was vortexed and centrifuged at 3000 g for 5 min, and then the upper layer was evaporated to dryness under a stream of nitrogen. The residue was dissolved in 40 µl ethyl acetate, and a 1-µl aliquot was injected into the GC-MS/MS. The GC separation of the compounds was achieved on a fused-silica capillary column Rxi-5Sil MS (30 m × 0.25 mm i.d.; 0.25-µm film thickness) and detected by MS/MS operating in electron ionization ion source mode. The regression equations showed excellent linearity (r > 0.9997) from 50 to 5000 ng/ml for plasma, with limit of detection of 10 ng/ml. The extraction efficiency of valproate for plasma ranged between 71.2%-103.5%. The coefficient of variation was <18.5%. The method was successfully applied to actual analyses of an autopsy case. This method can be useful for simple and reliable measurements of valproate in clinical and toxicological analyses; it can be integrated in screening and simultaneous determination methods for multiple drugs and poisons in the further studies.


Assuntos
Anticonvulsivantes/sangue , Cromatografia Gasosa-Espectrometria de Massas/métodos , Espectrometria de Massas em Tandem/métodos , Ácido Valproico/sangue , Adulto , Anticonvulsivantes/química , Feminino , Patologia Legal , Humanos , Secobarbital/sangue , Secobarbital/química , Ácido Valproico/química
11.
J Pharm Biomed Anal ; 44(2): 602-7, 2007 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-17267160

RESUMO

Methamphetamine and amphetamine were extracted from human urine samples using pipette tip solid-phase extraction (SPE) with MonoTip C18 tips (pipette tip volume, 200 microl), in which C18-bonded monolithic silica gel was fixed. A sample of human urine (0.5 ml) containing methamphetamine, amphetamine, and N-methylbenzylamine as internal standard (IS), was mixed with 25 microl of 1M sodium hydroxide solution. The mixture was extracted into the C18 phase of the SPE tip by 25 repeated aspirating/dispensing cycles using a manual micropipettor. Analytes retained in the C18 phase were then eluted with methanol by five repeated aspirating/dispensing cycles. After derivatization with trifluoroacetic anhydride, analytes were measured by gas chromatography/mass spectrometry with selected ion monitoring in the positive-ion electron impact mode. Recoveries of methamphetamine, amphetamine, and IS spiked into urine were more than 82.9, 82.2, and 78.2%, respectively. Regression equations for methamphetamine and amphetamine showed excellent linearity in the range of 0.25-200 ng/0.5 ml. Limit of detection was 0.04 ng/0.5 ml for methamphetamine and 0.05 ng/0.5 ml for amphetamine. Intra- and inter-day coefficients of variations for both stimulants were not greater than 10.8%. The data obtained from actual determination of methamphetamine and amphetamine in autopsy urine samples are also presented for validation of the method.


Assuntos
Anfetaminas/urina , Estimulantes do Sistema Nervoso Central/urina , Metanfetamina/urina , Autopsia , Toxicologia Forense , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Indicadores e Reagentes , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Extração em Fase Sólida , Soluções
12.
Leg Med (Tokyo) ; 24: 36-55, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28081789

RESUMO

A high-throughput method was developed for the detection of 31 benzodiazepine drugs and tandospirone in human plasma by on-line column-switching ultra-fast liquid chromatography-tandem mass spectrometry. Plasma samples (100µl) spiked with the 32 drugs and oxazepam-d5 (internal standard) were diluted with 300µl of 13.3mM ammonium acetate/acetonitrile (33:67, v/v). After centrifugation and filtration, the clear supernatant was injected directly onto the extraction column (Oasis HLB cartridge column). The following procedure was fully automated. The analytes retained on the extraction column were eluted by backflushing of the extraction column and introduced into an analytical column (SUMIPAX ODS D-Swifter column, 30mm×3.0mm i.d.; particle size 2µm) by column switching. Quantification was performed by multiple reaction monitoring with positive-ion electrospray ionization. Distinct peaks appeared for each drug and the internal standard on each channel within 7min, including the extraction time. All drugs spiked into plasma showed recoveries of 83-95%. The regression equations for the 32 drugs showed excellent linearities in the range of 50-2000pg/ml of plasma and the limits of detection ranged from 20 to 50pg/ml. The lower and upper limits of quantitation were 50-100ng/ml and 2000pg/ml, respectively. Intra- and interday coefficients of variation for none of the drugs were greater than 13.6%. The accuracies of quantitation were 87-112%. The multiple reaction monitoring information-dependent acquisition of enhanced product ions method enabled the quantification and confirmation of diazepam, triazolam, and lorazepam obtained from actual plasma.


Assuntos
Benzodiazepinas/sangue , Cromatografia Líquida de Alta Pressão , Isoindóis/sangue , Piperazinas/sangue , Pirimidinas/sangue , Espectrometria de Massas em Tandem/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
13.
Artigo em Inglês | MEDLINE | ID: mdl-16893687

RESUMO

A method for the simultaneous determination of selegiline and its metabolite, desmethylselegiline, in human whole blood and urine is presented. The method, which combines a fiber-based headspace solid-phase microextraction (SPME) technique with gas chromatography-mass spectrometry (GC-MS), required optimization of various parameters (e.g., salt additives, extraction temperatures, extraction times and the extraction properties of the SPME fiber coatings). Pargyline was used as the internal standard. Extraction efficiencies for both selegiline and desmethylselegiline were 2.0-3.4% for whole blood, and 8.0-13.2% for urine. The regression equations for selegiline and desmethylselegiline extracted from whole blood were linear (r(2)=0.996 and 0.995) within the concentration ranges 0.1-10 and 0.2-20 ng/ml, respectively. For urine, the regression equations for selegiline and desmethylselegiline were linear (r(2)=0.999 and 0.998) within the concentration ranges 0.05-5.0 and 0.1-10 ng/ml, respectively. The limit of detection for selegiline and desmethylselegiline was 0.01-0.05 ng/ml for both samples. The lower and upper limits of quantification for each compound were 0.05-0.2 and 5-20 ng/ml, respectively. Intra- and inter-day coefficients of variation for selegiline and desmethylselegiline in both samples were not greater than 8.7 and 11.7%, respectively. The determination of selegiline and desmethylselegiline concentrations in Parkinson's disease patients undergoing continuous selegiline treatment is presented and is shown to validate the present methodology.


Assuntos
Anfetaminas/análise , Líquidos Corporais/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Selegilina/análise , Microextração em Fase Sólida/métodos , Anfetaminas/sangue , Anfetaminas/urina , Humanos , Estrutura Molecular , Reprodutibilidade dos Testes , Selegilina/sangue , Selegilina/urina
14.
J Pharm Biomed Anal ; 41(1): 64-9, 2006 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-16378708

RESUMO

Triazolam was analyzed from human plasma samples by high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) with an MSpak GF polymer column (50 mm x 4.6 mm i.d., particle size 6 microm), which enabled direct injection of crude biological samples. Separation of triazolam, and lorazepam as the internal standard (IS) was carried out using 10mM ammonium acetate (pH 3.56)-0.1% formic acid and an acetonitrile gradient elution. Both compounds formed base peaks due to [M + H]+ ions by HPLC/ESI-MS, and product ions were produced from each [M + H]+ ion as seen by HPLC-MS/MS. Quantification of triazolam and the IS in plasma samples was made by selective reaction monitoring using each base peak of product ions of HPLC-MS/MS. The recovery range of triazolam spiked into plasma was 86.4-92.7%. The regression equation for triazolam showed excellent linearity in the range of 0.25-20 ng/mL, and the detection limit was 0.1 ng/mL. Intra- and inter-day precisions for triazolam in plasma samples were not greater than 12.4%. Accuracy for the drug was in the range of 88.0-101.4%. Data obtained after oral administration of triazolam in male and female subjects are also presented.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Triazolam/análise , Triazolam/sangue , Acetonitrilas/química , Administração Oral , Adulto , Química Farmacêutica/métodos , Feminino , Formiatos/química , Humanos , Concentração de Íons de Hidrogênio , Masculino , Modelos Químicos , Análise de Regressão , Reprodutibilidade dos Testes
15.
J AOAC Int ; 88(6): 1655-60, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16526447

RESUMO

Seven phenothiazine derivatives, perazine, perphenazine, prochlorperazine, propericiazine, thioproperazine, trifluoperazine, and flupentixol, have been found to be extractable from human plasma and urine samples using disk solid-phase extraction (SPE) with an Empore C18 cartridge. Human plasma and urine (1 mL each) containing the 7 phenothiazine derivatives were mixed with 2 mL of 0.1M NaOH and 7 mL distilled water and then poured into the disk SPE cartridges. The drugs were eluted with 1 mL chloroform- acetonitrile (8 + 2) and determined by liquid chromatography with ammonium formate/formic acid-acetonitrile gradient elution. The detection was performed by ultraviolet absorption at 250 nm. The separation of the 7 phenothiazine derivatives from each other and from impurities was generally satisfactory using a SymmetryShield RP8 column (150 x 2.1 mm id, 3.5 microm particle size). The recoveries of the 7 phenothiazine derivatives spiked into plasma and urine samples were 64.0-89.9% and 65.1-92.1%, respectively. Regression equations for the 7 phenothiazine derivatives showed excellent linearity, with detection limits of 0.021-0.30 microg/mL for plasma and 0.017-0.30 microg/mL for urine. The within-day and day-to-day coefficients of variation for both samples were commonly below 9.0 and 14.9%, respectively.


Assuntos
Líquidos Corporais/metabolismo , Cromatografia Líquida/métodos , Fenotiazinas/análise , Acetonitrilas/química , Análise Química do Sangue/métodos , Clorofórmio/química , Humanos , Modelos Lineares , Modelos Químicos , Fenotiazinas/química , Padrões de Referência , Análise de Regressão , Fatores de Tempo , Urinálise/métodos , Água/química
16.
Jpn J Ophthalmol ; 59(5): 364-71, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26088457

RESUMO

PURPOSE: To evaluate a new rapid and sensitive method for analyzing human tears and plasma for nonsteroidal anti-inflammatory drugs (NSAIDs) and investigate the influence of the transfer of NSAIDs in an ocular lesion. METHODS: In this cross-over study, a single dose of 200 mg of ibuprofen and 60 mg of loxoprofen sodium were orally administered to six healthy Japanese subjects. Collected samples were analyzed by ultra-fast liquid chromatography tandem mass spectrometry (UFLC-MS/MS). RESULTS: Recoveries of the two drugs spiked in the tears and plasma were 96.0-117.0 % in the tears and 99.0-105.7 % in the plasma. Regression equations for both NSAIDs showed excellent linearity from 0.02-1.0 µg/ml for the tears and 0.1-5.0 µg/ml for the plasma, with the limits of detection at 0.02 µg/ml for tears and 0.1 µg/ml for plasma. CONCLUSION: This new high-throughput NSAID determination method only requires a small tear amount (10 µl) and plasma volume (20 µl) and thus will be useful in clinical and toxicological analyses. Analytical results also showed the presence of ibuprofen and loxoprofen in the actual tears and plasma, which confirms the transition of NSAIDs from the tears to the plasma.


Assuntos
Anti-Inflamatórios não Esteroides/farmacocinética , Ibuprofeno/farmacocinética , Fenilpropionatos/farmacocinética , Lágrimas/metabolismo , Administração Oral , Adulto , Análise Química do Sangue , Cromatografia Líquida , Estudos Cross-Over , Feminino , Voluntários Saudáveis , Humanos , Ibuprofeno/administração & dosagem , Masculino , Pessoa de Meia-Idade , Fenilpropionatos/administração & dosagem , Espectrometria de Massas em Tandem
17.
J Mass Spectrom ; 39(10): 1147-52, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15468125

RESUMO

Paraquat (PQ) and diquat (DQ) in human whole blood and urine were analyzed by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) with positive ion electrospray ionization (ESI). The compounds were extracted with Sep-Pak C18 cartridges from whole blood and urine samples containing ethyl paraquat as an internal standard. The separation of PQ and DQ was carried out using ion-pair chromatography with heptafluorobutyric acid in 20 mM ammonium acetate and acetonitrile gradient elution for successful coupling with MS. Both compounds formed base peaks due to [M-H]+ ions by HPLC/ESI-MS and the product ions produced from each [M-H]+ ion by HPLC/MS/MS. Selective reaction monitoring (SRM) showed much higher sensitivity for both body fluids. Therefore, a detailed procedure for the detection of compounds by SRM with HPLC/MS/MS was established and carefully validated. The recoveries of PQ and DQ were 80.8-95.4% for whole blood and 84.2-96.7% for urine. The calibration curves for PQ and DQ showed excellent linearity in the range of 25-400 ng ml(-1) of whole blood and urine. The detection limits were 10 ng ml(-1) for PQ and 5 ng ml(-1) for DQ in both body fluids. The intra- and inter-day precision for both compounds in whole blood and urine samples were not greater than 13.0%. The data obtained from the determination of PQ and DQ in rat blood after oral administration of the compounds are also presented.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Diquat/sangue , Herbicidas/sangue , Espectrometria de Massas/métodos , Paraquat/sangue , Animais , Líquidos Corporais/química , Química Clínica/instrumentação , Diquat/análise , Diquat/urina , Herbicidas/análise , Herbicidas/urina , Humanos , Paraquat/análise , Paraquat/urina , Ratos
18.
J Pharm Biomed Anal ; 88: 71-80, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24036363

RESUMO

A simple and sensitive method was developed and validated here for the analysis of thirteen nonsteroidal anti-inflammatory drugs (NSAIDs) in human plasma samples by hydrophilic interaction liquid chromatography (HILIC)-tandem mass spectrometry (MS/MS). A small volume of plasma (20µL) spiked with compounds was diluted with 80µL of 10-mM ammonium acetate followed by a simple protein precipitation with 400µL of acetonitrile. After centrifugation, the clear supernatant extract was directly injected into the HILIC-MS/MS, without any solvent evaporation and reconstitution steps. The chromatographic separation of the NSAIDs was achieved on a Unison UK-Amino HILIC column (50mm×3mm i.d., particle size 3µm) with a linear gradient elution system composed of 10mM ammonium acetate (pH 6.8) and acetonitrile at a flow rate of 0.4mL/min. The mass spectra obtained by HILIC-MS showed base peak ions due to [M+H](+) for indomethacin, oxaprozin, ketoprofen, alminoprofen, zaltoprofen, tiaprofenic acid, pranoprofen, and ketoprofen-d3 and due to [M-H](-) for etodolac, ibuprofen, diclofenac, fenoprofen, loxoprofen, naproxen, and ibuprofen-d3. Recoveries of these thirteen NSAIDs in plasma were 34.8-113% and the lower limits of quantitation were 0.125-1.25µg/mL. The intra- and interday coefficient of variations for all drugs in plasma were less than 14.6%. The data obtained from actual plasma determinations of zaltoprofen, ibuprofen, and diclofenac are also presented.


Assuntos
Anti-Inflamatórios/sangue , Análise Química do Sangue , Monitoramento de Medicamentos , Espectrometria de Massas em Tandem , Acetatos/química , Acetonitrilas/química , Administração Oral , Adulto , Anti-Inflamatórios não Esteroides , Humanos , Interações Hidrofóbicas e Hidrofílicas , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Análise de Regressão , Reprodutibilidade dos Testes , Solventes/química
19.
Leg Med (Tokyo) ; 14(5): 267-71, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22546247

RESUMO

Dimemorfan was extracted from human plasma samples (100 µL) using MonoTip C(18) tips, which were packed with a C(18)-bonded monolithic silica gel attached to the inside of the tip. The samples, which contained dimemorfan and trimeprazine as an internal standard (IS), were mixed with 300 µL of distilled water and 50 µL of 1M glycine-sodium hydroxide buffer (pH 10). The mixture was extracted onto the C(18) phase of the tip by 20 sequential aspirating/dispensing cycles using a manual micropipettor. The analytes retained on the C(18) phase were then eluted with methanol by five sequential aspirating/dispensing cycles. The eluate was injected directly into a gas chromatograph and detected by a mass spectrometer with selected ion monitoring in positive electron ionization mode. An Equity-5 fused silica capillary column (30 m × 0.32 mm i.d., film thickness 0.25 µm) gave adequate separation of the dimemorfan, IS, and impurities. The recoveries of dimemorfan and the IS spiked into plasma were ≥83%. The regression equation for dimemorfan showed excellent linearity from 0.25 to 32.0 ng/100 µL of plasma, and the limit of detection was 0.125 ng/100 µL of plasma. The maximum intra-day and inter-day relative standard deviations were 13%, while accuracy ranged from 88% to 105%. Dimemorfan was stable for at least 12 h at 4°C, 4 weeks at -80°C, and three freeze-thaw cycles in plasma. This new method is expected to have application as a pretreatment for the rapid, simple, and quantitative determination of dimemorfan in plasma samples.


Assuntos
Morfinanos/análise , Plasma/química , Extração em Fase Sólida/métodos , Trimeprazina/análise , Antipruriginosos/análise , Antitussígenos/análise , Humanos , Extração em Fase Sólida/instrumentação
20.
J Chromatogr A ; 1218(18): 2521-7, 2011 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-21429493

RESUMO

Solid-phase extraction (SPE) using micropipette tips is a useful technique to prepare samples prior to mass spectrometry. However, most commercial SPE tips have loading capacities that are insufficient for quantitative determination. In this paper, we describe a rapid method for quantitative microanalysis of five phenothiazine derivatives, chlorpromazine, levomepromazine, promazine, promethazine and trimeprazine, using a recently introduced C(18) monolithic silica SPE tip, the MonoTip C(18), for extraction from human plasma. The drugs could be extracted within 5 min from 0.1-mL plasma samples, eluted with methanol, and the eluate injected directly into a gas chromatograph prior to mass spectrometry analysis. Only 0.7 mL of solvent was required for each step of the extraction process. The recoveries of the five phenothiazines spiked into plasma were 91-95% and the limits of quantification for each drug were between 0.25 and 2.0 ng/0.1 mL. The maximum intra- and inter-day coefficient of variation was 11%. The validated method was successfully used to quantify the plasma concentration of levemepromazine in a human subject after oral administration of the drug. This new method is expected to have wide applications as a pretreatment for the rapid, quantitative determination of drug concentrations in plasma samples.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Fenotiazinas/sangue , Extração em Fase Sólida/instrumentação , Extração em Fase Sólida/métodos , Adulto , Estabilidade de Medicamentos , Feminino , Humanos , Modelos Lineares , Metotrimeprazina/análogos & derivados , Metotrimeprazina/sangue , Metotrimeprazina/farmacocinética , Porosidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA