Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Brief Bioinform ; 25(3)2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38627939

RESUMO

The latest breakthroughs in spatially resolved transcriptomics technology offer comprehensive opportunities to delve into gene expression patterns within the tissue microenvironment. However, the precise identification of spatial domains within tissues remains challenging. In this study, we introduce AttentionVGAE (AVGN), which integrates slice images, spatial information and raw gene expression while calibrating low-quality gene expression. By combining the variational graph autoencoder with multi-head attention blocks (MHA blocks), AVGN captures spatial relationships in tissue gene expression, adaptively focusing on key features and alleviating the need for prior knowledge of cluster numbers, thereby achieving superior clustering performance. Particularly, AVGN attempts to balance the model's attention focus on local and global structures by utilizing MHA blocks, an aspect that current graph neural networks have not extensively addressed. Benchmark testing demonstrates its significant efficacy in elucidating tissue anatomy and interpreting tumor heterogeneity, indicating its potential in advancing spatial transcriptomics research and understanding complex biological phenomena.


Assuntos
Benchmarking , Perfilação da Expressão Gênica , Análise por Conglomerados , Redes Neurais de Computação
2.
J Environ Manage ; 359: 120954, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38692026

RESUMO

Plastic products' widespread applications and their non-biodegradable nature have resulted in the continuous accumulation of microplastic waste, emerging as a significant component of ecological environmental issues. In the field of microplastic detection, the intricate morphology poses challenges in achieving rapid visual characterization of microplastics. In this study, photoacoustic imaging technology is initially employed to capture high-resolution images of diverse microplastic samples. To address the limited dataset issue, an automated data processing pipeline is designed to obtain sample masks while effectively expanding the dataset size. Additionally, we propose Vqdp2, a generative deep learning model with multiple proxy tasks, for predicting six forms of microplastics data. By simultaneously constraining model parameters through two training modes, outstanding morphological category representations are achieved. The results demonstrate Vqdp2's excellent performance in classification accuracy and feature extraction by leveraging the advantages of multi-task training. This research is expected to be attractive for the detection classification and visual characterization of microplastics.


Assuntos
Aprendizado Profundo , Microplásticos , Técnicas Fotoacústicas , Microplásticos/análise , Técnicas Fotoacústicas/métodos , Monitoramento Ambiental/métodos , Plásticos
3.
RSC Adv ; 14(31): 22497-22503, 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39015667

RESUMO

The development of a green, safe, and accurate sample preparation method for the determination of trace metal elements in environmental samples is of great importance. Choline chloride-based deep eutectic solvents (DESs) were used to extract heavy metal elements from litterfall and the target analytes were measured using inductively coupled plasma optical emission spectrometry. Factors such as the type, ratio, dosage, and extraction time and temperature of the DESs were studied. A DES system based on choline chloride and maleic acid had the highest extraction efficiency of 98.5%, 88.4%, 90.2%, and 93.7% for Cd, Cu, Zn, and Fe. Under the optimized conditions, the limits of detection and limits of quantification were in the range of 0.04-0.70 and 0.13-2.30 mg kg-1. The repeatability (n = 3), estimated in terms of the relative standard deviation, ranged from 1.14% to 3.40%. The proposed method was validated for accuracy using GBW10087. Notably, the energy consumption of the newly developed method was only one-fifth that of a traditional acid digestion method. This work not only presents an environmentally friendly method for the determination of trace element concentrations in environmental samples but also deepens our understanding of DES systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA