Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 59(7)2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37512033

RESUMO

Background and Objectives: Minimally invasive cardiac surgery (MICS) has been developing since 1996. Peripheral cannulation is required to perform MICS, and good venous drainage and a bloodless field are crucial for the success of this procedure. We assessed the benefits of using a virtually wall-less cannula in comparison with the standard thin-wall cannula in clinical practice. Materials and Methods: Between January 2021 and December 2022, we evaluated 65 elective patients, who underwent isolated minimally invasive mitral valve surgery. Both the virtually wall-less and the thin-wall cannulas were placed through a surgical cut-down. Patients' characteristics at baseline were similar in the two groups, except for the body surface area (BSA), which was greater in the virtually wall-less group compared to the thin-wall one. In the standard group, the size of the cannula was chosen depending on the patient's BSA, and the choice of the Smartcannula was based on their height. Results: There were no significant differences between the two groups in terms of negative pressure applied, target flow achieved, hemolysis, the need for blood transfusion, and the post-operative increases in liver and renal enzymes. However, in all the patients, the estimated target flow was achieved, thereby showing the better hemodynamic performance of the virtually wall-less cannula, since, in this group, the patients' BSA was significantly greater compared to the thin-wall group. Ultimately, the mean cross-clamp time, as an indirect index of the effectiveness of the venous drainage, is shorter in the virtually wall-less group compared with the thin-wall group. Conclusions: The virtually wall-less cannula should be preferred in minimally invasive mitral valve surgery due to its superior performance in terms of venous drainage compared with the standard thin-wall cannula.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Mitral , Humanos , Valva Mitral/cirurgia , Cânula , Cateterismo/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
2.
J Cardiovasc Echogr ; 33(1): 40-42, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37426718

RESUMO

A 76-year-old man with history of previous coronary artery bypass grafting, permanent atrial fibrillation in novel oral anticoagulation therapy, and gastrointestinal bleedings underwent percutaneous left atrial appendage closure. The procedure was complicated by intraoperative device embolization, which caused a dynamic obstruction of the left ventricular outflow tract leading to severe hemodynamic instability. Transesophageal echocardiography showed a device in the ventricle site of the mitral anterior leaflet. The coronary angiography showed also patency of both arterial grafts in stable coronary artery disease. After failing the percutaneous retrieval with a snare, emergent surgery was planned. A moderate calcified aortic valve stenosis was also found, but in consideration of the unstable clinical conditions of the patient, we thought of performing a transcatheter aortic valve replacement (TAVR) in a second time. We have carefully planned the surgical retrieval of the device embolized paying attention of his several comorbidities. The strategy to remove the device with cardiopulmonary bypass without cross-clamping the aorta through a right mini-thoracotomy has been preferred.

3.
J Cardiovasc Dev Dis ; 8(12)2021 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-34940518

RESUMO

Intraoperative assessment of graft patency is pivotal for successful coronary revascularization. In the present study we aimed to propose a new, easy to perform tool to assess anastomotic quality intraoperatively, and to investigate its potential reliability in predicting early graft failure. Intraoperative graft flowmetry of 63 consecutive patients undergoing CABG were prospectively collected. Transit time flowmetry and its derivatives were recorded. Coronary resistances were calculated according to Hagen-Poiseuille equation both during cardioplegic arrest and after withdrawal from cardiopulmonary bypass. Angiographic evidence of graft occlusion at follow-up was cross-checked with intraoperative recordings. After a mean follow-up of 10.4 ± 6.0 months, 22 grafts were studied, and occlusion was documented in five (22.7%). Occluded grafts showed lower flows and higher resistances recorded during aortic cross-clamping. Coronary resistances, recorded during aortic cross-clamping, greater than 2.0 mmHg/mL/min, showed a sensitivity of 80% and a specificity of 100% to predict graft failure. We propose the routine recording of coronary resistances during aortic cross-clamping as an additional tool to overcome the acknowledged limitation of TTF to predict graft occlusion at 1 year.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA