Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Ultrasound Obstet Gynecol ; 62(1): 14-22, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36776132

RESUMO

OBJECTIVE: A favorable postnatal prognosis in cases of pulmonary atresia/critical stenosis with intact ventricular septum (PA/CS-IVS) is generally equated with the possibility of achieving biventricular (BV) repair. Identification of fetuses that will have postnatal univentricular (UV) circulation is key for prenatal counseling, optimization of perinatal care and decision-making regarding fetal therapy. We aimed to evaluate the accuracy of published models for predicting postnatal circulation in PA/CS-IVS using a large internationally derived validation cohort. METHODS: This was a systematic review of published uni- and multiparametric models for the prediction of postnatal circulation based on echocardiographic findings at between 20 and 28 weeks of gestation. Models were externally validated using data from the International Fetal Cardiac Intervention Registry. Sensitivity, specificity, predictive values, area under the receiver-operating-characteristics curves (AUCs) and proportion of cases with true vs predicted outcome were calculated. RESULTS: Eleven published studies that reported prognostic parameters of postnatal circulation were identified. Models varied widely in terms of the main outcome (UV (n = 3), non-BV (n = 3), BV (n = 3), right-ventricle-dependent coronary circulation (n = 1) or tricuspid valve size at birth (n = 1)) and in terms of the included predictors (single parameters only (n = 6), multiparametric score (n = 4) or both (n = 1)), and were developed on small sample sizes (range, 15-38). Nine models were validated externally given the availability of the required parameters in the validation cohort. Tricuspid valve diameter Z-score, tricuspid regurgitation, ratios between right and left cardiac structures and the presence of ventriculocoronary connections (VCC) were the most commonly evaluated parameters. Multiparametric models including up to four variables (ratios between right and left structures, right ventricular inflow duration, presence of VCC and tricuspid regurgitation) had the best performance (AUC, 0.80-0.89). Overall, the risk of UV outcome was underestimated and that of BV outcome was overestimated by most models. CONCLUSIONS: Current prenatal models for the prediction of postnatal outcome in PA/CS-IVS are heterogeneous. Multiparametric models for predicting UV and non-BV circulation perform well in identifying BV patients but have low sensitivity, underestimating the rate of fetuses that will ultimately have UV circulation. Until better discrimination can be achieved, fetal interventions may need to be limited to only those cases in which non-BV postnatal circulation is certain. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Atresia Pulmonar , Insuficiência da Valva Tricúspide , Septo Interventricular , Gravidez , Recém-Nascido , Feminino , Humanos , Atresia Pulmonar/diagnóstico por imagem , Constrição Patológica , Estudos Retrospectivos
2.
J Biomed Mater Res A ; 82(3): 768-76, 2007 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-17330873

RESUMO

Thin film nitinol and single crystal Ni-Mn-Ga represent two new shape memory materials with potential to be used as percutaneously placed implant devices. However, the biocompatibility of these materials has not been adequately assessed. Immersion tests were conducted on both thin film nitinol and single crystal Ni-Mn-Ga in Hank's balanced salt solution at 37 degrees C and pH 7.4. After 12 h, large pits were found on the Ni-Mn-Ga samples while thin film nitinol displayed no signs of corrosion. Further electrochemical tests on thin film nitinol samples revealed breakdown potentials superior to a mechanically polished nitinol disc. These results suggest that passivation or electropolishing of thin film nitinol maybe unnecessary to promote corrosion resistance.


Assuntos
Ligas , Corrosão , Teste de Materiais , Níquel , Materiais Biocompatíveis/normas , Soluções Isotônicas , Titânio
3.
Cancer Res ; 56(14): 3192-5, 1996 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-8764104

RESUMO

Manganese superoxide dismutase (MnSOD) is a superoxide anion scavenger located in mitochondria. Increased expression of MnSOD can diminish oxygen radical-mediated injuries and the cytotoxic effects of tumor necrosis factor alpha, ionizing radiation, and certain chemotherapeutic agents. We used immunohistochemical staining to analyze 42 specimens of human brain tumors and 3 normal brain controls with a polyclonal antibody recognizing human MnSOD. We measured MnSOD in cerebrospinal fluid (CSF) from 14 patients with brain tumors and 7 control patients using an ELISA. Although MnSOD is not readily detected in normal brain, malignant central nervous system tumors, including tumors metastatic to the brain, displayed marked immunoreactivity to MnSOD intracellularly, in the extracellular matrix and in the tumor endothelial cells. Grade IV astrocytomas (glioblastomas), Grade III astrocytomas, and medulloblastomas were strongly immunoreactive, whereas Grade II astrocytomas had much less immunoreactivity. ELISA analysis of CSF samples from patients with malignant tumors also revealed high levels of MnSOD protein, up to 45-fold greater than the level of control CSF samples.


Assuntos
Neoplasias Encefálicas/enzimologia , Superóxido Dismutase/metabolismo , Encéfalo/enzimologia , Histocitoquímica , Humanos , Mitocôndrias/enzimologia
4.
J Biomed Mater Res B Appl Biomater ; 100(3): 718-25, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22121079

RESUMO

A flexible, low profile, flow diversion stent could replace endovascular coiling for the treatment of intracranial aneurysms. Micropatterned-thin film nitinol (TFN) is a novel biomaterial with high potential for use in next-generation endovascular devices. Recent advancements in micropatterning have allowed for fabrication of a hyperelastic thin film nitinol (HE-TFN). In this study, the authors describe in vitro and in vivo testing of novel HE-TFN based flow diverting stents. Two types of HE-TFN with expanded pores having long axes of 300 and 500 µm were used to fabricate devices. In vitro examination of the early thrombotic response in whole blood showed a possible mechanism for the device's function, whereby HE-TFN serves as a scaffold for blood product deposition. In vivo testing in swine demonstrated rapid occlusion of model wide-neck aneurysms. Average time to occlusion for the 300-µm device was 10.4 ± 5.5 min. (N = 5) and 68 ± 30 min for the 500-µm device (N = 5). All aneurysms treated with bare metal control stents remained patent after 240 min (N = 3). SEM of acutely harvested devices supported in vitro results, demonstrating that HE-TFN serves as a scaffold for blood product deposition, potentially enhancing its flow-diverting effect. Histopathology of devices after 42 days in vivo demonstrated a healthy neointima and endothelialization of the aneurysm neck region. HE-TFN flow-diverting stents warrant further investigation as a novel treatment for intracranial aneurysms.


Assuntos
Ligas , Aneurisma Intracraniano/cirurgia , Teste de Materiais , Stents , Animais , Modelos Animais de Doenças , Feminino , Humanos , Porosidade , Suínos
5.
Biomaterials ; 31(34): 8864-71, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20810163

RESUMO

Because of its low profile and biologically inert behavior, thin film nitinol (TFN) is ideally suited for use in construction of endovascular devices. We have developed a surface treatment for TFN designed to minimize platelet adhesion by creating a superhydrophilic surface. The hemocompatibility of expanded polytetrafluorethylene (ePTFE), untreated thin film nitinol (UTFN), and a surface treated superhydrophilic thin film nitinol (STFN) was compared using an in vitro circulation model with whole blood under flow conditions simulating a moderate arterial stenosis. Scanning electron microscopy analysis showed increased thrombus on ePTFE as compared to UTFN or STFN. Total blood product deposition was 6.3 ± 0.8 mg/cm(2) for ePTFE, 4.5 ± 2.3 mg/cm(2) for UTFN, and 2.9 ± 0.4 mg/cm(2) for STFN (n = 12, p < 0.01). ELISA assay for fibrin showed 326 ± 42 µg/cm(2) for ePTFE, 45.6 ± 7.4 µg/cm(2) for UTFN, and 194 ± 25 µg/cm(2) for STFN (n = 12, p < 0.01). Platelet deposition measured by fluorescent intensity was 79,000 20,000 AU/mm(2) for ePTFE, 810 ± 190 AU/mm(2) for UTFN, and 1600 ± 25 AU/mm(2) for STFN (n = 10, p < 0.01). Mass spectrometry demonstrated a larger number of proteins on ePTFE as compared to either thin film. UTFN and STFN appear to attract significantly less thrombus than ePTFE. Given TFN's low profile and our previously demonstrated ability to place TFN covered stents in vivo, it is an excellent candidate for use in next-generation endovascular stents grafts.


Assuntos
Ligas/farmacologia , Estenose Coronária/fisiopatologia , Hemorreologia/efeitos dos fármacos , Teste de Materiais/métodos , Plaquetas/efeitos dos fármacos , Plaquetas/metabolismo , Proteínas Sanguíneas/química , Proteínas Sanguíneas/metabolismo , Fibrina/metabolismo , Humanos , Espectrometria de Massas , Microscopia Eletrônica de Varredura , Microscopia de Fluorescência , Trombose/patologia
6.
Pediatr Cardiol ; 27(1): 149-155, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16261272

RESUMO

In children with pulmonary atresia not amenable to initial complete correction, antegrade pulmonary blood flow can be established with surgical right ventricular outflow tract (RVOT) patch enlargement. An 11-year experience with RVOT transannular patch (TAP) augmentation without the use of cardiopulmonary bypass (off-pump) is reported. From March 1993 to October 2004, off-pump surgical RVOT enlargement with a TAP was attempted in all patients in whom a concurrent procedure that required bypass was not required. The procedure was performed with cardiopulmonary bypass standby. Twenty-two consecutive patients in whom this procedure was attempted were reviewed. Twenty of 22 patients tolerated off-pump TAP placement. In 2 patients with ductal-dependent pulmonary blood flow, off-pump TAP placement was not tolerated. Adequate antegrade pulmonary blood flow was achieved in all patients without operative mortalities or complications. There was one death in the postoperative period from myocardial ischemia secondary to right ventricular-dependent coronary circulation. Transannular RVOT patch augmentation can be performed safely and effectively without cardiopulmonary bypass.


Assuntos
Angioplastia com Balão , Implante de Prótese Vascular , Cateterismo Cardíaco , Ponte Cardiopulmonar , Comunicação Interventricular/cirurgia , Ventrículos do Coração/cirurgia , Atresia Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Angioplastia com Balão/instrumentação , Implante de Prótese Vascular/instrumentação , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Feminino , Comunicação Interventricular/diagnóstico , Ventrículos do Coração/patologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Lactente , Recém-Nascido , Pulmão/irrigação sanguínea , Imageamento por Ressonância Magnética , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Cuidados Paliativos , Complicações Pós-Operatórias/diagnóstico , Atresia Pulmonar/diagnóstico , Estenose da Valva Pulmonar/diagnóstico , Estudos Retrospectivos , Rizotomia/instrumentação , Instrumentos Cirúrgicos , Técnicas de Sutura , Tetralogia de Fallot/diagnóstico , Obstrução do Fluxo Ventricular Externo/diagnóstico
7.
Pediatr Cardiol ; 27(1): 168-169, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16391983

RESUMO

We report two children, age 7 months and 5 years, who underwent surgery for congenital heart disease and developed persistent pleural effusions with elevated eosinophil counts. Given the elevation of eosinophil counts in both blood and pleural fluid of these patients, it was considered that an allergic response might have caused the persistent effusion. In both cases, the effusion resolved within 48 hours after treatment with corticosteroids was begun. It is possible that postoperative eosinophilic pleural effusion may represent a subgroup of effusions that are more likely to respond to treatment with corticosteroids.


Assuntos
Eosinofilia/tratamento farmacológico , Glucocorticoides/administração & dosagem , Cardiopatias Congênitas/cirurgia , Hemissuccinato de Metilprednisolona/administração & dosagem , Derrame Pleural/tratamento farmacológico , Complicações Pós-Operatórias/tratamento farmacológico , Tubos Torácicos , Pré-Escolar , Terapia Combinada , Dieta com Restrição de Gorduras , Eosinófilos/efeitos dos fármacos , Humanos , Lactente , Infusões Intravenosas , Contagem de Leucócitos , Masculino , Nutrição Parenteral Total
8.
Pediatr Cardiol ; 26(3): 267-74, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16082575

RESUMO

Embolizations of coils and devices are well-known complications of transcatheter procedures performed in order to occlude extracardiac or intracardiac shunts. A review of the literature and of our experience was performed to provide a succinct review of existing transcatheter retrieval techniques. After embolization of a coil or device, the appropriate initial procedure involves repositioning of the coil or device using a snare or bioptome to a location where harm to the patient is minimized. The subsequent retrieval technique depends on the characteristics of the coil or device involved. Coils may be retrieved using a bioptome or a snare. Devices must be snared, often in specific places. Both may be pulled into long or short, appropriately sized retrieval sheaths. To minimize potential morbidities associated with these retrievals and to maximize efficacy of retrieval, operators performing transcatheter coil or device occlusions must be familiar with retrieval techniques.


Assuntos
Cateterismo Cardíaco/instrumentação , Embolização Terapêutica/instrumentação , Cardiopatias Congênitas/terapia , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardiovasculares/métodos , Embolia/etiologia , Embolia/prevenção & controle , Embolização Terapêutica/métodos , Desenho de Equipamento , Defeitos dos Septos Cardíacos/terapia , Humanos
9.
Pediatr Cardiol ; 26(6): 762-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16132277

RESUMO

Given the volume of pediatric orthotopic heart transplants (OHTs) at several centers, it is now possible to generate pediatric-specific, single-center OHT survival data. The transplant experience for 152 pediatric OHT patients at our institution was reviewed. The following were noted for each patient: graft survival; immunosuppressant therapy; initial diagnosis; cause of graft failure; clinical status at time of transplant; donor and recipient blood type, sex, weight, and age; ischemic time; previous cardiac surgery; race; and immune status. A series of Kaplan-Meier survival curves were constructed. Univariate comparisons of survival curves were performed with the Breslow test to determine equality of each pair of curves. Only immunosuppression with tacrolimus and an initial diagnosis of noncongenital heart disease positively influenced survival in pediatric OHT patients (p < or = 0.021 and p < or = 0.03, respectively). The more recently transplanted patients, managed with tacrolimus, had less mortality early after OHT (acute rejection) and less mortality during the period 2 or 3 years after OHT. No other factors, including prior cardiothoracic surgery, sex matching, and race matching, significantly influenced survival. Recently transplanted patients managed with tacrolimus-based immunosuppression and patients with noncongenital cardiomyopathy have significantly superior graft survival.


Assuntos
Doença das Coronárias/cirurgia , Sobrevivência de Enxerto , Cardiopatias Congênitas/cirurgia , Transplante de Coração , Criança , Doença das Coronárias/tratamento farmacológico , Feminino , Humanos , Imunossupressores/uso terapêutico , Masculino , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Tacrolimo/uso terapêutico
10.
Minerva Pediatr ; 56(1): 1-28, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15249911

RESUMO

Pediatric interventional catheterization is an expanding specialty with a range of mature, emerging, and investigative procedures and technologies. Many dysfunctional obstructions and/or shunts caused by congenital heart defects may be treated or significantly palliated in the catheterization laboratory. These include valvar pulmonary or aortic stenosis, the patent ductus arteriosus, coarctation of the aorta, branch pulmonary stenosis, atrial septal defects and even ventricular septal defects. Valve replacement technology, approaches to complex heart diseases such as single ventricle, and fetal interventions are subjects of active investigations. A comprehensive review of the present and future of interventional pediatric cardiology is presented.


Assuntos
Cardiologia/tendências , Pediatria/tendências , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/métodos , Serviço Hospitalar de Cardiologia/tendências , Cateterismo de Swan-Ganz , Criança , Serviços de Saúde da Criança/tendências , Cardiopatias/congênito , Cardiopatias/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Humanos , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA