Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Lasers Med Sci ; 37(2): 919-928, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34052927

RESUMO

PURPOSE: To evaluate the safety and efficacy of an at-home photobiomodulation (PBM) device for the treatment of diabetic foot ulcers (DFUs) in a frail population with severe comorbidities. METHODS: Prospective, randomized, double-blind, sham-controlled pilot study. Patients (age = 63 ± 11 years, male:female 13:7) with insulin-dependent diabetes type 2, neuropathy, peripheral artery disease, significant co-morbidities, and large osteomyelitis-associated DFUs (University of Texas grade ≥ III) were randomized to receive active (n = 10) or sham (n = 10) at-home daily PBM treatments (pulsed near-infrared 808 nm Ga-Al-As laser, 250 mW, 8.8 J/cm2) for up to 12 weeks in addition to standard care. The primary outcome was the %wound size reduction. The secondary was adverse events. RESULTS: With the numbers available, PBM-treated group had significantly greater %reduction compared to sham (area [cm2], baseline vs endpoint: PBM 10[20.3] cm2 vs 0.2[2.4] cm2; sham, 7.9 [12.0] cm2 vs 4.6 [13.8] cm2, p = 0.018 by Mann-Whitney U test). Wound closure > 90% occurred in 7 of 10 PBM-treated patients but in only 1 of 10 sham patients (p = 0.006). No adverse device effects were observed. CONCLUSIONS: Photobiomodulation at home, in addition to standard care, may be effective for the treatment of severe DFUs in frail patients with co-morbidities and is particularly relevant at these times of social distancing. Our preliminary results justify the conduction of a larger clinical trial. CLINICALTRIALS: gov: NCT01493895.


Assuntos
Diabetes Mellitus , Pé Diabético , Terapia com Luz de Baixa Intensidade , Idoso , Pé Diabético/radioterapia , Método Duplo-Cego , Feminino , Idoso Fragilizado , Humanos , Lasers , Terapia com Luz de Baixa Intensidade/métodos , Masculino , Pessoa de Meia-Idade , Morbidade , Projetos Piloto , Estudos Prospectivos , Cicatrização
2.
BMC Surg ; 22(1): 125, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35365145

RESUMO

BACKGROUND: Spinal trauma patients treated in a specialized hybrid operating room (OR) using two robotic systems communicating during surgery. METHODS: Retrospective review of patients with thoracolumbar or sacral fractures who underwent surgical fixation between Jan 2017 to Jan 2020 with robotic-guided percutaneous pedicle screw insertion in the specialized hybrid OR with Robotic flat panel 3D C-arm (ArtisZeego) for intraoperative interventional imaging connected with the robotic-guidance platform Renaissance (Mazor Robotics). RESULTS: Twenty eight surgeries were performed in 27 patients; 23 with traumatic spinal fractures, 4 with multi-level thoracolumbar compression fractures due to severe osteoporosis. Average patient age 49 (range 12-86). Average radiation exposure time 40 s (range 12-114 s). Average radiation exposure dose 11,584 ± SD uGym2 (range 4454-58,959). Lumber levels operated on were between T5 and S2 (shortest three vertebras and longest eight vertebras). 235 (range 5-11) trajectories were performed. All trajectories were accurate in all cases percutaneous pedicle screws placement was correct, without breach noted at the pedicle in any of the cases. No major complications reported. In all cases, follow-up X-rays showed adequate fracture reduction with restoration. CONCLUSIONS: Merging of surgical robotics technologies increases patient safety and surgeon and patient confidence in percutaneous spine traumatic procedures.


Assuntos
Parafusos Pediculares , Robótica , Fraturas da Coluna Vertebral , Humanos , Pessoa de Meia-Idade , Robótica/métodos , Região Sacrococcígea , Sacro/cirurgia , Fraturas da Coluna Vertebral/cirurgia
3.
Int Orthop ; 46(9): 1971-1975, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35718826

RESUMO

INTRODUCTION: Accurate templating is an integral part of pre-operative planning for total hip arthroplasty (THA). Templating of cementless implant accuracy has been average. The aim of this study was to assess the impact of Dorr femoral classification on the accuracy of pre-operative digital templating. PATIENTS AND METHODS: This was a retrospective study of cementless THA pre-operative planning using one implant design. A total of 210 primary THA were reviewed. A total of 102 cementless THAs matched the exclusion and inclusion criteria, using one implant combination, were analyzed by an orthopaedic resident and a fellowship trained arthroplasty surgeon. Each x-ray was evaluated and assigned a femoral Dorr classification. Accuracy of templating was determined by comparing the templated size with the actual implant size both for the femoral and acetabular components. RESULT: Out of the 102 cases, exact templating size was achieved in 35.3% for the acetabulum, 25.5% for the femur, and only in 9.8% for both components. Reasonable templating, ± one of the actual size, was achieved in 78.4% for the acetabulum, 74.5% for the femur, and 60.8% for both components. Use of Dorr femoral type classification did not result in better templating accuracy. CONCLUSION: Pre-operative hip cementless templating using digital x-rays with double marker method do not improve accuracy compared to other methods available for templating. Accounting for bone quality using the Dorr femoral classification did not improve accuracy.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/métodos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Cuidados Pré-Operatórios/métodos , Estudos Retrospectivos
4.
Isr Med Assoc J ; 23(8): 490-493, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34392623

RESUMO

BACKGROUND: Osteoporosis is a common medical condition in older ages. A devastating result of osteoporosis may be a hip fracture with up to 30% mortality rate in one year. The compliance rate of osteoporotic medication following a hip fracture is 20% in the western world. OBJECTIVES: To evaluate the impact of the fracture liaison service (FLS) model in the orthopedic department on patient compliance following hip fracture. METHODS: We performed a retrospective review of all patients with hip fracture who were involved with FLS. We collected data regarding kidney function, calcium levels, parathyroid hormone levels, and vitamin D levels at admission. We educated the patient and family, started vitamin D and calcium supplementation and recommended osteoporotic medical treatment. We phoned the patient 6-12 weeks following the fracture to ensure treatment initiation. RESULTS: From June 2018 to June 2019 we identified 166 patients with hip fracture who completed at least one year of follow-up. Over 75% of the patients had low vitamin D levels and 22% had low calcium levels at admission. Nine patients (5%) died at median of 109 days. Following our intervention, 161 patients (96%) were discharged with a specific osteoporotic treatment recommendation; 121 (73%) received medication for osteoporosis on average of < 3 months after surgery. We recommended on injectable medications; however, 51 (42%) were treated with oral biphsophonate. CONCLUSIONS: FLS improved the compliance rate of osteoporotic medical treatment and should be a clinical routine in every medical center.


Assuntos
Cálcio/administração & dosagem , Fraturas do Quadril , Osteoporose , Fraturas por Osteoporose , Período Pós-Operatório , Prevenção Secundária , Vitamina D/administração & dosagem , Idoso , Conservadores da Densidade Óssea/administração & dosagem , Conservadores da Densidade Óssea/classificação , Suplementos Nutricionais , Quimioterapia Combinada , Feminino , Fraturas do Quadril/mortalidade , Fraturas do Quadril/prevenção & controle , Fraturas do Quadril/cirurgia , Humanos , Israel/epidemiologia , Masculino , Mortalidade , Procedimentos Ortopédicos/estatística & dados numéricos , Osteoporose/sangue , Osteoporose/complicações , Osteoporose/tratamento farmacológico , Osteoporose/epidemiologia , Fraturas por Osteoporose/mortalidade , Fraturas por Osteoporose/prevenção & controle , Fraturas por Osteoporose/cirurgia , Estudos Retrospectivos , Prevenção Secundária/métodos , Prevenção Secundária/organização & administração , Vitamina D/sangue
5.
J Arthroplasty ; 35(8): 2076-2083, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32307289

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) for valgus deformity is a challenge. The standard medial parapatellar approach may not be universally useful for this. We have adopted the lateral approach to valgus knees. Here we describe our experience with this approach, present early results, and compare them to the medial approach. METHODS: Our institutional registry was queried for all patients with valgus deformity who underwent a TKA via a lateral approach between 2013 and 2016. The registry was also queried for patients with valgus deformity who underwent a TKA through a medial approach in previous years and this data was compared to the study group. RESULTS: Seventy-nine valgus knees in 72 patients were operated through a lateral approach. Deformity was corrected by 10.8°, from 16.2° to 5.4° (P < .001). Patellar tilt improved from -2.3° to 0.3° (P = .037). Seven implants (9%) were constrained. Mean operating time was 87 minutes (range 53-137). Twenty-five knees in 23 patients were operated via the medial approach. Deformity was corrected by 7.3°, from 13.2° to 5.9° (P < .001). Mean operating time was 137 minutes (range 90-230). Constrained implants were used in 16% of cases. The lateral approach allowed better correction of valgus deformity (10.8 vs 7.3, P = .03) and shorter operative times (87 vs 137 minutes, P < .001). CONCLUSION: A lateral approach TKA for valgus deformity improves knee alignment and patellar tilt. Compared to the medial approach, it allows better correction of the deformity, shorter operating times, and perhaps less use of constrained implants.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Patela/cirurgia
6.
BMC Geriatr ; 19(1): 135, 2019 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-31109289

RESUMO

BACKGROUND: Most surviving hip-fracture patients experience reduced mobility and lose some of their functional ability, which increases the risk of complications and rehospitalization. Post-discharge transitional programs to reduce readmissions and disabilities have shown some success. Telerehabilitation refers to the use of technologies to provide rehabilitation services to people in their homes. Considering the need for long-term follow-up care for people with hip fracture, in-home telerehabilitation could increase independence, decrease hospital stays and reduce the burden for caregivers. The objective of this study is to investigate the effectiveness of an intervention program based on telerehabilitation on activities of daily living (ADL), quality of life (QOL), depression and burden on caregivers compared to face-to-face home visits and usual care of community-dwelling older adults after hip fracture. METHODS/DESIGN: This will be a three-armed randomized control trial (RCT) including pre/post intervention and follow-up. The trial will include 90 older people with hip fractures who will be randomly assigned to a telerehabilitation group (N = 30), face-to-face visits (N = 30) and a control group. The aim of the intervention is to improve the transition from rehabilitation units to community dwelling. It will include 10 videoconferencing/ face-to-face sessions from an occupational therapist in the presence of the primary caregiver. Each session will be utilized to guide the participants to achieve their self-identified goals, focusing on problem-solving for daily life situations and on the ability to implement the discussed strategies for a variety of activities. Outcome measures include Functional Independence Measure (FIM) for evaluation of ADL, SF-12 for evaluation of Health-related QOL, The Geriatric Depression Scale (GDS) and The Zarit Caregiver Burden Scale. Data will be analyzed using Repeated measures MANOVA. DISCUSSION: The current study will enable the cost-effectiveness examination of a suggested rehabilitation service based on available technology. The proposed intervention will increase accessibility of in-home rehabilitation services, improve function and health, and reduce economic burden. TRIAL REGISTRATION: NCT03376750 (12/15/2017).


Assuntos
Atividades Cotidianas , Fraturas do Quadril/epidemiologia , Fraturas do Quadril/reabilitação , Cuidados Pós-Operatórios/métodos , Telerreabilitação/métodos , Idoso , Idoso de 80 Anos ou mais , Análise Custo-Benefício , Feminino , Seguimentos , Fraturas do Quadril/economia , Humanos , Masculino , Morbidade , Cuidados Pós-Operatórios/economia , Qualidade de Vida , Método Simples-Cego , Telerreabilitação/economia , Resultado do Tratamento
7.
Int Orthop ; 43(11): 2607-2612, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-30643935

RESUMO

BACKGROUND AND PURPOSE: As patients who were afflicted with poliomyelitis during the outbreaks in the past are aging, lower extremity osteoporotic fractures are becoming more frequent. Fixation in deformed, porotic bone, coupled with muscle weakness and imbalance creates a unique challenge when treating these fractures as does their reduced rehabilitation potential. The aim of this study was to investigate the outcome of femoral fractures in surviving poliomyelitis patients. PATIENTS AND METHODS: Sixty-five patients with 74 femoral fractures were treated between 1990 and 2014. Clinical outcome was assessed using the Parkland and Palmer mobility score, and quality-of-life was assessed using the SF-12® score. RESULTS: Some 84% of the fractures were a result of low-energy mechanisms and occurred in the polio-affected limbs, but nonaffected limbs were also injured owing to low-energy mechanisms in all cases. Fifty-seven fractures were treated operatively. There were nine re-operations (16%), including implant removals, nonunion, peri-implant fractures, and malunion. Some 60% of the patients did not regain their previous ambulatory capacity. Post-operative weight-bearing status did not correlate with the final functional outcome. CONCLUSIONS: Polio patients with femoral fractures have a guarded prognosis for regaining their pre-injury ambulatory capacity. A higher re-operation rate than that with "normal" osteoporotic fractures is expected.


Assuntos
Fraturas do Fêmur/cirurgia , Limitação da Mobilidade , Fraturas por Osteoporose/cirurgia , Poliomielite/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/reabilitação , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas por Osteoporose/etiologia , Fraturas por Osteoporose/reabilitação , Prognóstico , Recuperação de Função Fisiológica , Reoperação , Estudos Retrospectivos , Sobreviventes , Resultado do Tratamento , Caminhada , Suporte de Carga , Adulto Jovem
8.
Skeletal Radiol ; 47(4): 483-490, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29128913

RESUMO

OBJECTIVES: Malreduction in the axial plane (malrotation) following tibial fracture surgery is often undiagnosed. A few clinical and radiographic methods have been proposed for measuring tibial rotation intraoperatively, yet have failed to match the accuracy of computed tomography (CT). The aim of this study was to develop radiographic tools for future intraoperative assessment of the tibial shaft rotation profile. METHODS: The setting was a laboratory computerized analysis. Twenty lower limb CT scans were used to construct a three-dimensional (3D) model using AMIRA© software. A virtual 3D cylinder was implanted in the posterior condylar line and in the transmalleolar axis. The 3D models were used to simulate four standard knee and ankle plain radiographs. On each radiograph, four landmarks were depicted by two observers and their relation with the cylinder was measured and analyzed for accuracy and reproducibility. A cadaveric lower leg was implanted with two Kirschner wires. A CT scan was performed in addition to 2D fluoroscopy. The simulated radiographs and the fluoroscopy were compared for accuracy. RESULTS: Measurement of the landmarks showed reliability in most of the knee anteroposterior and ankle mortise radiographs (coefficients of variation < 0.01 and = 0.01) respectively. Cadaveric measurement of the landmarks using real fluoroscopy and simulated radiographs were similar. CONCLUSIONS: To date, no reliable and common methods have been reported for the evaluation of tibial axial rotation. We propose a model in which simple radiographic landmarks can be used to calculate a 3D coordinate system that accurately assesses the axial rotation angle of the tibial shaft.


Assuntos
Complicações Pós-Operatórias/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Anormalidade Torcional/diagnóstico por imagem , Pontos de Referência Anatômicos , Cadáver , Simulação por Computador , Estudos de Viabilidade , Fluoroscopia , Humanos , Imageamento Tridimensional , Cuidados Intraoperatórios , Masculino , Reprodutibilidade dos Testes , Rotação , Tomografia Computadorizada por Raios X
9.
Arch Orthop Trauma Surg ; 138(5): 661-667, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29427201

RESUMO

BACKGROUND: Femoral neck fractures (FNF) are becoming increasingly common as population ages. Nondisplaced fractures are commonly treated by cancellous, parallel placed, partially threaded cannulated screws (PTS). This allows controlled fracture impaction. However, sliding implants can lead to femoral neck shortening (FNS) that has been shown to be correlated with reduced quality of life and impaired gait pattern. Recently, in our institution we have changed the fixation of FNF to fully threaded screws (FTS) with or without an additional partially threaded screw in order to minimize this phenomenon. The aim of this study was to compare the FNS in patients treated with FTS as compared with our historical controls treated with PTS. PATIENTS AND METHODS: Between 2014 and 2016, 38 patients with FNF were treated with FTS. Out of the 38, 24 were available for radiographic follow-up. 41 patients treated previously with PTS were available as a control group. Radiographic analysis was performed to assess the FNF in three vectors: Horizontal (X), Vertical (Y) and overall (Z) according to the neck-shaft angle. RESULTS: Time for admission to surgery was longer in the PTS group (p = 0.04). Patient demographics and major complication rates were similar in the two patient groups. Average FNS in the X axis was significantly smaller in the FTS group than in the PTS group (2.8 ± 3.6 vs 7.6 ± 4.2 mm, p < 0.01) as well as the Y axis (1.2 ± 2.6 vs 4.9 ± 4.2 mm, p < 0.01) and thus also decreased overall Z shortening (2.3 ± 3.5 vs 6.23 ± 4.5 mm, p < 0.01). There was a tendency towards a more valgus reduction in the PTS (137° vs 134°, p = 0.08). There was a significantly smaller number of FTS patients with moderate (5-10 mm) or severe (> 10 mm) FNS. Screw pull-out > 5 mm occurred in 17/41 patients in the PTS but none in the FTS group (p < 0.01). CONCLUSION: This study proves that use of FTS improves the radiographic results following FNF fixation using cannulated screws.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Colo do Fêmur , Fixação Interna de Fraturas , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/fisiopatologia , Colo do Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Humanos , Radiografia
10.
Harefuah ; 157(3): 145-148, 2018 Mar.
Artigo em Hebraico | MEDLINE | ID: mdl-29582942

RESUMO

INTRODUCTION: Computer Assisted Orthopaedic Surgery (CAOS) was introduced in the late 1990's and early 2000's. Since then its application in orthopaedic trauma has been utilized mainly as augmented fluoroscopy for intraoperative navigation. From 2010 our center implemented an advanced system allowing further expansion of this technology. AIMS: The aim of this study was to describe the experience with an advanced fluoroscopic based CAOS system in our center. METHODS: The BrainLabTM Trauma 3.0 utilizes a handheld fluoroscope tracker, enables tracking of two anatomical objects and intraoperative planning. We implemented this system for the performance of 126 navigated procedures between the years 2011-2014. The procedures included 58 cases of navigated hip fracture pinning, 9 plate navigation for distal femoral fractures, 19 iliosacral screw insertions, 20 femoral fracture reductions, and 12 other procedures (acetabular screws, osteotomies etc). RESULTS: The mean age of patients was 52 years (range 16-82 years); 46 male and 80 female patients. The mean operating room time was 157 minutes (range 70 to 470 minutes). The average radiation required was 550 rad cm2 (~30 sec fluoroscopic time). Overall estimated additional OR time was estimated as 10-15 minutes for hip pinning, 15-20 minutes for pelvic iliosacral screws and 30-45 minutes of additional OR time for femur fracture reduction for length and rotation. In 5% of cases (6 patients), navigation was aborted due to technical reasons. No misplaced hardware due to the use of navigation was documented. CONCLUSIONS: CAOS is a powerful tool in trauma surgery with 95% success rate, with a reasonable added burden time. Although 3D navigation may be more useful in the pelvis, even two-dimensional navigation increases precision and implant placement. Femoral fracture reduction for accurate length and rotation control is solely enabled by CAOS. In the future, more time efficient and user-friendly systems will enable widespread use of these technologies in orthopaedic trauma.


Assuntos
Fraturas do Quadril/cirurgia , Ortopedia/métodos , Cirurgia Assistida por Computador , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
11.
Harefuah ; 157(3): 183-187, 2018 Mar.
Artigo em Hebraico | MEDLINE | ID: mdl-29582951

RESUMO

INTRODUCTION: Regenerative medicine research has evolved significantly in recent years. There is a great un-met clinical need for developing new treatments that will induce regeneration of injured skeletal tissues in cases such as large bony defects caused by trauma or tumor resection, articular cartilage defects and torn or degenerate tendons and ligaments. Except for bone that can regenerate small defects, all other skeletal tissues do not hold the natural capability for regeneration after injury and rather form a less functional scar tissue. In order to induce tissue regeneration, it is now believed that three crucial elements must reach the injured zone: a) multipotent cells that can rapidly proliferate and differentiate to form the injured tissues, such as mesenchymal stem cells for skeletal tissues; b) extra-cellular matrix that will support the newly built tissues, and c) the correct molecular signals. Using diverse research tools and expertise, our department focused its research on basic, translational and clinical solutions for injured and degenerative skeletal tissues. In this review we will describe our different research directions, from in-vitro cell cultures and animal models studies to human clinical trials.


Assuntos
Regeneração Óssea/fisiologia , Medicina Regenerativa , Animais , Osso e Ossos , Cartilagem , Modelos Animais de Doenças , Humanos , Células-Tronco Mesenquimais , Modelos Biológicos , Transplante de Células-Tronco
12.
J Cell Mol Med ; 20(5): 815-24, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26917487

RESUMO

Injuries to ligaments are common, painful and debilitating, causing joint instability and impaired protective proprioception sensation around the joint. Healing of torn ligaments usually fails to take place, and surgical replacement or reconstruction is required. Previously, we showed that in vivo application of the recombinant human amelogenin protein (rHAM(+)) resulted in enhanced healing of the tooth-supporting tissues. The aim of this study was to evaluate whether amelogenin might also enhance repair of skeletal ligaments. The rat knee medial collateral ligament (MCL) was chosen to prove the concept. Full thickness tear was created and various concentrations of rHAM(+), dissolved in propylene glycol alginate (PGA) carrier, were applied to the transected MCL. 12 weeks after transection, the mechanical properties, structure and composition of transected ligaments treated with 0.5 µg/µl rHAM(+) were similar to the normal un-transected ligaments, and were much stronger, stiffer and organized than control ligaments, treated with PGA only. Furthermore, the proprioceptive free nerve endings, in the 0.5 µg/µl rHAM(+) treated group, were parallel to the collagen fibres similar to their arrangement in normal ligament, while in the control ligaments the free nerve endings were entrapped in the scar tissue at different directions, not parallel to the axis of the force. Four days after transection, treatment with 0.5 µg/µl rHAM(+) increased the amount of cells expressing mesenchymal stem cell markers at the injured site. In conclusion application of rHAM(+) dose dependently induced mechanical, structural and sensory healing of torn skeletal ligament. Initially the process involved recruitment and proliferation of cells expressing mesenchymal stem cell markers.


Assuntos
Amelogenina/farmacologia , Ligamento Colateral Médio do Joelho/efeitos dos fármacos , Células-Tronco Mesenquimais/efeitos dos fármacos , Propriocepção/efeitos dos fármacos , Cicatrização/efeitos dos fármacos , Alginatos/administração & dosagem , Animais , Biomarcadores/metabolismo , Movimento Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Relação Dose-Resposta a Droga , Portadores de Fármacos , Feminino , Humanos , Ligamento Colateral Médio do Joelho/lesões , Ligamento Colateral Médio do Joelho/inervação , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/metabolismo , Terminações Nervosas/efeitos dos fármacos , Ratos , Proteínas Recombinantes/farmacologia , Resistência à Tração , Cicatrização/fisiologia
13.
J Arthroplasty ; 30(6): 1041-3, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25680448

RESUMO

Patients with peri-acetabular osteolysis around a well fixed cementless acetabular component may be treated with liner exchange. When the locking mechanism is unreliable or unavailable, cementing the liner into the fixed acetabular component is a feasible option. The purpose of this study was to evaluate the clinical and radiographic long term results of this technique. Forty hip revisions with liner cementation in 37 patients were performed. The minimum follow up was 10 years. Modified Harris Hip Score and recent x rays were reviewed. Four hips were re-revised. Two patients were diagnosed with exacerbation of osteolysis but refused revision. Dislocation rate was relatively high (16%). Liner cementation technique in revision hip surgery is useful in patients with a well fixed metal backed acetabular component.


Assuntos
Artroplastia de Quadril/métodos , Cimentação/métodos , Osteólise/cirurgia , Polietileno/química , Reoperação/métodos , Acetábulo/cirurgia , Feminino , Seguimentos , Prótese de Quadril , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Resultado do Tratamento , Raios X
14.
Mol Ther ; 21(8): 1631-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23732992

RESUMO

Distal tibial fractures tend towards delayed- or nonunion. The purpose of this study was to evaluate the safety and efficacy of early minimally invasive intervention (MII) in the treatment of these fractures. A total 24 consecutive patients who underwent operative treatment for distal tibial fractures were randomized into a control and an intervention group. MII entailed aspirating iliac crest bone marrow and peripheral blood, yielding mesenchymal stem cells (MSCs) and platelet-rich plasma (PRP) respectively, that were mixed with demineralized bone matrix (DBM) and injected under fluoroscopic control into the fracture site. No complications occurred in either group. The median time to union was 1.5 months in the MII group and 3 months in the control group. MII was found to be a safe and efficient procedure.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos , Fraturas não Consolidadas/terapia , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/metabolismo , Adolescente , Adulto , Terapia Baseada em Transplante de Células e Tecidos/efeitos adversos , Feminino , Humanos , Masculino , Transplante de Células-Tronco Mesenquimais/efeitos adversos , Pessoa de Meia-Idade , Qualidade de Vida , Resultado do Tratamento , Adulto Jovem
15.
J Shoulder Elbow Surg ; 23(8): 1150-5, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24581875

RESUMO

BACKGROUND: Proximal humeral locking plates have significantly improved the treatment of proximal humeral fractures in recent years; however, they are not devoid of complications. Inadvertent screw penetration into the joint is a well-documented complication. Intraoperative 3-dimensional (3D) imaging may assist in detecting intra-articular implant penetration. This study compared the performance of a standard C-arm fluoroscope with a novel 3D imaging fluoroscope in detecting penetrating implants in a proximal humeral fracture model. METHODS: Zinc-sprayed proximal humerus sawbones were affixed with a proximal humeral locking plate. Six different constructs were assembled. In each specimen, 1 screw, 2 screws, or no screws were inserted 2-mm proud of the articular surface. Each specimen was imaged with a conventional fluoroscope and a 3D imaging fluoroscope. Overall, 36 image sets were prepared for each modality. These were evaluated by 2 fellowship-trained surgeons for intraobserver and interobserver reliability as well for the accuracy of detecting prominent implants in the 2 imaging methods. RESULTS: Overall accuracy for observer A was 89.9% compared with 100% for C-arm fluoroscopy and 3D imaging fluoroscopy (P < .01) and for observer B was 91.1% and 100% (P = .01), respectively. The κ values were 0.74 with C-arm fluoroscopy and 1.0 for the 3D imaging fluoroscopy for observer A, and 0.93 and 1.0, respectively, for observer B. CONCLUSIONS: In a proximal humeral fracture model, C-arm fluoroscopy is a highly accurate imaging modality that can minimize the incidence of penetrating screws into the joint. Further clinical studies are required to establish this modality.


Assuntos
Parafusos Ósseos , Fluoroscopia , Fixação Interna de Fraturas/efeitos adversos , Cabeça do Úmero/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Humanos , Cabeça do Úmero/cirurgia , Imageamento Tridimensional , Complicações Intraoperatórias/diagnóstico por imagem , Modelos Anatômicos , Reprodutibilidade dos Testes
16.
Inquiry ; 61: 469580241230293, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38491840

RESUMO

The increase in hip fractures (HF) due to aging of the population and the rise in attractiveness of services provided at home following the COVID-19 pandemic, emphasize the need to compare outcomes of home versus hospital HF rehabilitation. To date, studies comparing the 2 services have focused primarily on clinical outcomes rather than patient-reported outcomes (PROs). This longitudinal observational study evaluated PROs of older adults with HF in the 2 settings. The SF36 questionnaire was used to measure PROs 3 times after surgery. The first PRO was retrospective and reflected pre-fracture health status. Descriptive statistics and mixed-effect logistic regression were used. Of 86 patients participating in the study, 41 had home rehabilitation and 45 had hospital rehabilitation. In both groups, the mental and physical scores plummeted 2 weeks after the HF, compared to pre-fracture status. The difference in improvement from pre-fracture status to recovery in both groups, were not significantly (P < .05) different, except for the pain domain. PROs of home versus hospital rehabilitation were similar, suggesting that rehabilitation at home can be as effective as hospital rehabilitation for suitable patients. This knowledge can improve quality of care in an aging global population.


Assuntos
Fraturas do Quadril , Pandemias , Humanos , Idoso , Estudos Retrospectivos , Fraturas do Quadril/reabilitação , Fraturas do Quadril/cirurgia , Hospitais
17.
Arthritis Rheum ; 64(3): 718-28, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21987377

RESUMO

OBJECTIVE: Sirtuin 1 (SirT1) has been implicated in the regulation of human cartilage homeostasis and chondrocyte survival. Exposing human osteoarthritic (OA) chondrocytes to tumor necrosis factor α (TNFα) generates a stable and enzymatically inactive 75-kd form of SirT1 (75SirT1) via cathepsin B-mediated cleavage. Because 75SirT1 is resistant to further degradation, we hypothesized that it has a distinct role in OA, and the present study was undertaken to identify this role. METHODS: The presence of cathepsin B and 75SirT in OA and normal human chondrocytes was analyzed. Confocal imaging of SirT1 was used to monitor its subcellular trafficking following TNFα stimulation. Coimmunofluorescence staining for cathepsin B, mitochondrial cytochrome oxidase subunit IV, and lysosome-associated membrane protein 1 together with SirT1 was performed. Human chondrocytes were tested for apoptosis by fluorescence-activated cell sorter analysis and immunoblotting for caspases 3 and 8. Human chondrocyte mitochondrial extracts were obtained and analyzed for 75SirT1-cytochrome c association. RESULTS: Confocal imaging and immunoblot analyses following TNFα challenge of human chondrocytes demonstrated that 75SirT1 was exported to the cytoplasm and colocalized with the mitochondrial membrane. Consistent with this, immunoprecipitation and immunoblot analyses revealed that 75SirT1 is enriched in mitochondrial extracts and associates with cytochrome c following TNFα stimulation. Preventing nuclear export of 75SirT1 or reducing levels of full-length SirT1 and 75SirT1 augmented chondrocyte apoptosis in the presence of TNFα. Levels of cathepsin B and 75SirT1 were elevated in OA versus normal chondrocytes. Additional analyses showed that human chondrocytes exposed to OA-derived synovial fluid generated the 75SirT1 fragment. CONCLUSION: These data suggest that 75SirT1 promotes chondrocyte survival following exposure to proinflammatory cytokines.


Assuntos
Apoptose/efeitos dos fármacos , Cartilagem Articular/metabolismo , Condrócitos/metabolismo , Osteoartrite do Joelho/metabolismo , Sirtuína 1/metabolismo , Fator de Necrose Tumoral alfa/metabolismo , Idoso , Cartilagem Articular/efeitos dos fármacos , Cartilagem Articular/patologia , Catepsina B/genética , Catepsina B/metabolismo , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Condrócitos/efeitos dos fármacos , Citocromos c/metabolismo , Citoplasma/efeitos dos fármacos , Citoplasma/metabolismo , Expressão Gênica , Humanos , Mitocôndrias/efeitos dos fármacos , Mitocôndrias/metabolismo , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/cirurgia , Sirtuína 1/genética , Fator de Necrose Tumoral alfa/farmacologia
18.
Isr Med Assoc J ; 15(3): 148-52, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23662376

RESUMO

BACKGROUND: Explosion injuries to the upper extremity have specific clinical characteristics that differ from injuries due to other mechanisms. OBJECTIVES: To evaluate the upper extremity injury pattern of attacks on civilian targets, comparing bomb explosion injuries to gunshot injuries and their functional recovery using standard outcome measures. METHODS: Of 157 patients admitted to the hospital between 2000 and 2004, 72 (46%) sustained explosion injuries and 85 (54%) gunshot injuries. The trauma registry files were reviewed and the patients completed the DASH Questionnaire (Disabilities of Arm, Shoulder and Hand) and SF-12 (Short Form-12) after a minimum period of 1 year. RESULTS: Of the 157 patients, 72 (46%) had blast injuries and 85 (54%) had shooting injuries. The blast casualties had higher Injury Severity Scores (47% vs. 22% with a score of > 16, P = 0.02) and higher percent of patients treated in intensive care units (47% vs. 28%, P = 0.02). Although the Abbreviated Injury Scale score of the upper extremity injury was similar in the two groups, the blast casualties were found to have more bilateral and complex soft tissue injuries and were treated surgically more often. No difference was found in the SF-12 or DASH scores between the groups at follow up. CONCLUSIONS: The casualties with upper extremity blast injuries were more severely injured and sustained more bilateral and complex soft tissue injuries to the upper extremity. However, the rating of the local injury to the isolated limb is similar, as was the subjective functional recovery.


Assuntos
Traumatismos do Braço , Traumatismos por Explosões , Procedimentos Cirúrgicos Operatórios , Extremidade Superior/cirurgia , Ferimentos por Arma de Fogo , Escala Resumida de Ferimentos , Adolescente , Adulto , Traumatismos do Braço/classificação , Traumatismos do Braço/epidemiologia , Traumatismos do Braço/etiologia , Traumatismos do Braço/fisiopatologia , Traumatismos do Braço/cirurgia , Traumatismos por Explosões/epidemiologia , Traumatismos por Explosões/fisiopatologia , Traumatismos por Explosões/cirurgia , Bombas (Dispositivos Explosivos) , Explosões , Feminino , Humanos , Escala de Gravidade do Ferimento , Israel/epidemiologia , Tempo de Internação/estatística & dados numéricos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Recuperação de Função Fisiológica , Sistema de Registros/estatística & dados numéricos , Procedimentos Cirúrgicos Operatórios/classificação , Procedimentos Cirúrgicos Operatórios/métodos , Procedimentos Cirúrgicos Operatórios/reabilitação , Inquéritos e Questionários , Centros de Traumatologia/estatística & dados numéricos , Extremidade Superior/lesões , Extremidade Superior/fisiopatologia , Ferimentos por Arma de Fogo/epidemiologia , Ferimentos por Arma de Fogo/fisiopatologia , Ferimentos por Arma de Fogo/cirurgia
19.
J Reconstr Microsurg ; 29(8): 495-500, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23757152

RESUMO

Immune system augmentation, using the antigen glatiramer acetate (GA), which is known to affect cellular immunity, has been shown to have a positive effect on peripheral nerve regeneration. We aimed to compare the effect of GA on the regeneration of crushed versus transected nerves. Wild-type rats underwent crush or transection and repair of the sciatic nerve. They were examined 3 weeks postinjury histologically (axon count) and functionally (tibialis anterior muscle weight and footprint analysis). GA was found to augment regeneration both histologically and functionally. In the transected nerve, a significant increase in axon count distal to the injury site was seen in the GA group versus control. A similar yet statistically insignificant trend was found in the crushed nerve. Improvement was found in the footprint analysis between the GA and control groups in both crush and transected nerve groups. We found improvement in the footprint analysis in the crush versus transection group. GA was found to improve the regeneration of the peripheral nerve. Histologically, this was more pronounced in the transection injury. The discrepancy between the different functional measures examined may be explained by the distance of the reinnervated muscles evaluated from the injury site.


Assuntos
Compressão Nervosa , Regeneração Nervosa/efeitos dos fármacos , Regeneração Nervosa/imunologia , Peptídeos/farmacologia , Traumatismos dos Nervos Periféricos/tratamento farmacológico , Traumatismos dos Nervos Periféricos/imunologia , Nervo Isquiático/efeitos dos fármacos , Nervo Isquiático/lesões , Animais , Axônios , Adjuvante de Freund/farmacologia , Acetato de Glatiramer , Imunidade Celular , Músculo Esquelético/inervação , Ratos , Ratos Sprague-Dawley
20.
Comput Assist Surg (Abingdon) ; 28(1): 2162970, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36637291

RESUMO

Correct mechanical alignment (180° hip-knee-angle (HKA)) may be difficult to obtain on a consistent basis in obese patients. This is a randomized controlled study comparing the post-operative coronal alignment in obese patients between two surgical total knee arthroplasty (TKA) techniques - conventional and computer assisted navigation. The primary outcome was the post-operative HKA. A total of 60 patients were assigned to undergo conventional total knee arthroplasty (30 patients) or computerized assisted stereotaxic navigation system with Bluetooth communication surgery (30 patients). One patient from the study group was excluded due to malfunction of the navigation system. Good quality x-rays were available in 57 patients. There was no difference between the groups. Post-operative HKA was 2.8° and 2.9° in the study and control groups, respectively (p = 0.87). In obese patients undergoing TKA, computerized navigation had no impact on post-op HKA. Clincal Trial Registration Number: HMO 0092-13.


Assuntos
Artroplastia do Joelho , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/efeitos adversos , Articulação do Joelho/cirurgia , Radiografia , Período Pós-Operatório
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA