Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 86(5): 2337-44, 2014 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-24517117

RESUMO

Metabolites excreted by skin have a huge potential as disease biomarkers. However, due to the shortage of convenient sampling/analysis methods, the analysis of sweat has not become very popular in the clinical setting (pilocarpine iontophoresis being a prominent exception). In this report, a facile method for sampling and rapid chemical profiling of skin metabolites excreted with sweat is proposed. Metabolites released by skin (primarily the constituents of sweat) are collected into hydrogel (agarose) micropatches. Subsequently, they are extracted in an online analytical setup incorporating nanospray desorption electrospray ionization and an ion trap mass spectrometer. In a series of reference measurements, using bulk sampling and electrospray ionization mass spectrometry, various low-molecular-weight metabolites are detected in the micropatches exposed to skin. The sampling time is as short as 10 min, while the desorption time is 2 min. Technical precision of micropatch analysis varies within the range of 3-42%, depending on the sample and the method of data treatment; the best technical precision (≤10%) has been achieved while using an isotopically labeled internal standard. The limits of detection range from 7 to 278 pmol. Differences in the quantities of extracted metabolites are observed for the samples obtained from healthy individuals (intersubject variabilities: 30-89%; n = 9), which suggests that this method may have the potential to become a semiquantitative assay in clinical analysis and forensics.


Assuntos
Hidrogéis , Pele/metabolismo , Administração Tópica , Espectrometria de Massas por Ionização por Electrospray , Suor
2.
Anal Chem ; 85(8): 3836-41, 2013 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-23496007

RESUMO

Diamond nanoparticles (DNPs) were incorporated into matrix-assisted laser desorption/ionization (MALDI) samples to enhance the sensitivity of the mass spectrometer to carbohydrates. The DNPs optimize the MALDI sample morphology and thermalize the samples for thermally labile compounds because they have a high thermal conductivity, a low extinction coefficient in UV-vis spectral range, and stable chemical properties. The best enhancement effect was achieved when matrix, DNP, and carbohydrate solutions were deposited and vacuum-dried consecutively to form a trilayer sample morphology. It allows the direct identification of underivatized carbohydrates mixed with equal amount of proteins because no increase in the ion abundance of proteins was achieved. For dextran with an average molecular weight of 1500, the trilayer method typically improves the sensitivity by 79- and 7-fold in comparison to the conventional dried-droplet and thin-layer methods, respectively.


Assuntos
Dextranos/análise , Diamante/química , Nanopartículas/química , Proteínas/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Temperatura Alta , Íons , Razão Sinal-Ruído , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
3.
Talanta ; 72(2): 368-72, 2007 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-19071626

RESUMO

A capillary electrophoresis Raman spectroscopy (CE-RS) method based on the stacking and sweeping modes are described. A non-fluorescent compound (malachite green, MG; crystal violet, CV) and a doubled Nd:YAG laser (532 nm, 300 mW) were selected as the model compound and light source, respectively. In order to carry out a quantitative and analysis of MG, a monochromator was used to collect the specific Raman line at 1616 cm(-1) (the N-phi and C-C stretching, corresponding to 582 nm when the wavelength of the exciting source is 532 nm). The limit of detection (LOD) for MG was 1.6 x 10(-5) and 1.1 x 10(-5)M, respectively, based on the CZE and MEKC modes. This could be improved to 3.4 x 10(-7) and 5.3 x 10(-9)M, respectively, when the stacking and sweeping modes were applied. The method was also extended to the determination of MG in an actual sample.

SELEÇÃO DE REFERÊNCIAS