Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Heart Vessels ; 37(2): 337-346, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34524496

RESUMO

Performing transcatheter aortic valve implantation with high implantation technique, i.e. with an aorto-ventricular ratio > 60/40, reduces the need of permanent pacemaker implantation. Valve calcification and prosthesis oversizing are predictors of permanent pacemaker implantation, but there are no available data on their role when transcatheter aortic valve implantation is performed with an aorto-ventricular ratio > 60/40. The aim of this study was to evaluate the effect of leaflets/annulus calcification and prosthesis oversizing on the incidence of permanent pacemaker implantation after transcatheter aortic valve implantation with a high implantation technique. Transcatheter aortic valve implantation was performed in 48 patients implanting a balloon-expandable transcatheter heart valve with an aorto-ventricular ratio > 60/40. Calcium burden was assessed by preprocedural multidetector computed tomography. An invasive electrophysiological study was performed before and after transcatheter aortic valve implantation. Five patients (10.4%) needed permanent pacemaker implantation. At univariate analysis, baseline right bundle branch block and postprocedural PR, QRS and His-ventricular interval elongation significantly predicted permanent pacemaker implantation (p < 0.05). Receiver-operating characteristic curve analysis showed a correlation between transcatheter heart valve oversizing and permanent pacemaker implantation need, with the best cut-off being 17% (AUC = 0.72, p = 0.033). Linear regression analysis demonstrated that QRS complex elongation was related to total, left and non-coronary leaflet calcification (p < 0.05). This study demonstrates that, when transcatheter aortic valve implantation is performed using a balloon-expandable transcatheter heart valve deployed with an aorto-ventricular ratio > 60/40, the presence of leaflets/annulus calcification or the need to oversize the prosthesis correlate with the occurrence of pathological cardiac conduction delays.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Biomedicines ; 12(6)2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38927500

RESUMO

Arrhythmic risk stratification in patients with Lamin A/C gene (LMNA)-related cardiomyopathy influences clinical decisions. An implantable cardioverter defibrillator (ICD) should be considered in patients with an estimated 5-year risk of malignant ventricular arrhythmia (MVA) of ≥10%. The risk prediction score for MVA includes non-missense LMNA mutations, despite their role as an established risk factor for sudden cardiac death (SCD) has been questioned in several studies. The purpose of this study is to investigate cardiac features and find gene-phenotype correlations that would contribute to the evidence on the prognostic implications of non-missense vs. missense mutations in a cohort of LMNA mutant patients. An observational, prospective study was conducted in which 54 patients positive for a Lamin A/C mutation were enrolled, and 20 probands (37%) were included. The median age at first clinical manifestation was 41 (IQR 19) years. The median follow-up was 8 years (IQR 8). The type of LMNA gene mutation was distributed as follows: missense in 26 patients (48%), non-frameshift insertions in 16 (30%), frameshift deletions in 5 (9%), and nonsense in 7 (13%). Among the missense mutation carriers, two (8%) died and four (15%) were admitted onto the heart transplant list or underwent transplantation, with a major adverse cardiovascular event (MACE) rate of 35%. No statistically significant differences in MACE prevalence were identified according to the missense and non-missense mutation groups (p value = 0.847). Our data shift the spotlight on this considerable topic and could suggest that some missense mutations may deserve attention regarding SCD risk stratification in real-world clinical settings.

3.
Expert Rev Pharmacoecon Outcomes Res ; 23(9): 1101-1111, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37589294

RESUMO

OBJECTIVES: Percutaneous coronary intervention (PCI) represents the standard treatment for ST-elevated myocardial infarction, nevertheless, mortality and heart failures are frequent. Pressure-controlled intermittent coronary sinus occlusion (PiCSO) might reduce infarct size showing better patients' outcomes. We evaluated the cost-effectiveness of PCI+PiCSO compared to PCI from the National Healthcare Service (NHS) perspective in Italy. METHODS: A Markov model was developed to estimate life years (LYs), quality-adjusted life years (QALYs) and costs. A micro-costing analysis has been performed to inform the cost of PCI+PiCSO procedure. Sensitivity analyses were performed to test the robustness of the model results. RESULTS: Considering a willingness-to-pay threshold of 50,000€/QALY for the ICUR and a cost for PCI+PiCSO procedure of 14,654€, the innovative strategy may be cost-effective compared to PCI alone from the Italian NHS perspective, showing an ICUR of 17,530€/QALY (ICER 14,631€/LY) over a lifetime horizon; the probabilistic sensitivity analysis showed that PCI+PiCSO is cost-effective in 78.8% of simulations.Considering the above mentioned willingness-to-pay threshold, PCI+PiCSO strategy would be cost-effective over a lifetime horizon considering a cost for PCI+PiCSO procedure lower than 28,160€. CONCLUSION: PCI+PiCSO procedure may be considered a cost-effective technology that allows reducing cardiac events, while improving patients' life expectancy and quality of life.


Assuntos
Seio Coronário , Insuficiência Cardíaca , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/métodos , Análise de Custo-Efetividade , Qualidade de Vida , Análise Custo-Benefício , Anos de Vida Ajustados por Qualidade de Vida
4.
Hellenic J Cardiol ; 70: 19-27, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36581137

RESUMO

BACKGROUND: Acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is a frequent complication associated with adverse outcomes and mortality. Various scores have been developed to predict this complication in the coronary setting. However, none have ever been tested in a large TAVI population. This study aimed to evaluate the power of four different scores in predicting AKI after TAVI. METHODS: Overall, 1535 consecutive TAVI patients from the observational multicentric "Magna Graecia" TAVI registry were included in the analysis. Of the study population, 235 (15.31%) developed AKI early. The Mehran, William Beaumont Hospital, CR4EATME3AD3, and ACEF scores were calculated retrospectively. RESULTS: The patients who developed TAVI-related AKI had significantly higher absolute values of all risk scores than those who did not. The receiver-operating characteristic analysis also showed a significant correlation between these four scores and AKI, but without a significant difference among all of them (p value = 0.176). Nevertheless, based on their area under the curve values (≤0.604 for all), none had adequate diagnostic accuracy in predicting TAVI-related AKI. Importantly, multivariate analysis identified myocardial revascularization close to the TAVI procedure and implantation of self-expanding prostheses, as well as atrial fibrillation, low-osmolar contrast media administration, corrected contrast medium volume, and any transfusion (p value < 0.05 for all) as independent risk factors for AKI. CONCLUSIONS: Although high values of current AKI risk scores are significantly associated with the development of this complication, these are not sufficiently accurate. Further studies are needed so that a TAVI-dedicated AKI risk score may be created.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
5.
J Cardiovasc Dev Dis ; 10(6)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37367409

RESUMO

BACKGROUND: Surgical mortality risk scores, even if not properly designed and rarely tested in the transcatheter aortic valve implantation (TAVI) setting, still guide the heart team in managing significant aortic stenosis. METHODS: After splitting 1763 consecutive patients retrospectively based on their mortality risk thresholds, the composite endpoint early safety (ES) was adjudicated according to Valve Academic Research Consortium (VARC)-2 and -3 consensus documents. RESULTS: ES incidence was higher if VARC-2 rather than VARC-3 defined. Despite only patients showing VARC-2 ES had significantly lower absolute values of all three main risk scores, these last still failed to foresee both VARC-2 and -3 ES in intermediate-risk patients. The receiver operating characteristic analysis also showed a significant correlation, but with poor diagnostic accuracy, among the three scores and only VARC-2 ES; moreover, the absence of VARC-2 ES and low-osmolar contrast media administration were identified as independent predictors of 1-year mortality and absence of VARC-3 ES, respectively. Finally, even a single complication included in the ES definition could significantly affect 1-year mortality. CONCLUSION: Currently, the most used mortality risk scores do not have adequate diagnostic accuracy in predicting ES after TAVI. The absence of VARC-2, instead of VARC-3, ES is an independent predictor of 1-year mortality.

6.
Int J Cardiol ; 329: 56-62, 2021 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-33359334

RESUMO

BACKGROUND: Acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is frequent and associated with adverse outcomes and mortality; to date, in such setting of patients there is no consistent evidence that either low-osmolar contrast media (LOCM) or iso-osmolar contrast medium (IOCM) are superior to the other in terms of renal safety. METHODS: 697 consecutive patients not in hemodialysis treatment who underwent TAVI (327 males, mean age 81.01 ± 5.75 years, mean european system for cardiac operative risk evaluation II 6.17 ± 0.23%) were enrolled. According to osmolality of the different iodinated CM, the population was divided in 2 groups: IOCM (n = 370) and LOCM group (n = 327). Preoperatively, 40.54% of patients in IOCM vs 39.14% in LOCM group (p = 0.765) suffered from chronic kidney disease (CKD). RESULTS: The incidence of AKI was significantly lower with IOCM (9.73%) than with LOCM (15.90%; p = 0.02), and such significant difference (p < 0.001) in postprocedural change of renal function parameters persisted at discharge too. The incidence of AKI was also significantly lower with IOCM in younger patients, without diabetes, anemia, coronary artery disease history, CKD, chronic or persistent atrial fibrillation, left ventricular ejection fraction ≤35%, and in patients with low operative mortality risk scores, receiving lower amounts of dye (p < 0.05 for all). Importantly, multivariate analysis identified LOCM administration as an independent risk factor for both AKI (p = 0.006) and 1-year mortality (p = 0.001). CONCLUSIONS: The use of IOCM have a favorable impact on renal function with respect to LOCM, but it should be considered especially for TAVI patients at lower AKI risk.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Meios de Contraste/efeitos adversos , Humanos , Masculino , Concentração Osmolar , Sistema de Registros , Fatores de Risco , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
7.
World J Clin Cases ; 9(25): 7472-7477, 2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34616814

RESUMO

BACKGROUND: Laminopathies are rare diseases, whose cardiac manifestations are heterogeneous and, especially in their initial stage, similar to those of more common conditions, such as ischemic heart disease. Early diagnosis is essential, as these conditions can first manifest themselves with sudden cardiac death. Electrical complications usually appear before structural complications; therefore, it is important to take into consideration these rare genetic disorders for the differential diagnosis of brady and tachyarrhythmias, even when left ventricle systolic function is still preserved. CASE SUMMARY: A 60-year-old man, without history of previous disorders, presented in September 2019 to the emergency department because of the onset of syncope associated with hypotension. The patient was diagnosed with a high-grade atrioventricular block. A dual chamber pacemaker was implanted, but after the onset of a sustained ventricular tachycardia during physical exertion, a drug eluting stent was implanted on an intermediate stenosis on the left anterior descending artery, which had previously been considered non-haemodynamically significant. During the follow-up, the treating cardiologist, suspicious of the overall clinical picture, recommended a genetic test for the diagnosis of cardiomyopathies, which tested positive for a pathogenetic mutation of the lamin A/C gene. While awaiting the result of the genetic test and, later, the pacemaker to be upgraded to a biventricular defibrillator, a remote monitoring device was given to the patient in order to minimize in-person clinical evaluations during the coronavirus disease 2019-related lockdown. CONCLUSION: This case aims to raise awareness of the cardiological manifestations of laminopathies, which can be dangerously misdiagnosed as other, more common conditions.

8.
Data Brief ; 35: 106827, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33659591

RESUMO

A comprehensive description of baseline characteristics, procedural features and outcomes related to the development of acute kidney injury (AKI) after transcatheter aortic valve implantation (TAVI) is reported in our research paper (Impact of contrast medium osmolality on the risk of acute kidney injury after transcatheter aortic valve implantation: insights from the Magna Graecia TAVI registry. Int J Cardiol. DOI: 10.1016/j.ijcard.2020.12.049). Three Italian heart centers were involved in this multicentric observational study. Between March 2011 and February 2019, a total of 888 patients underwent TAVI; according to the inclusion and exclusion criteria, 697 patients were included in the post-hoc analysis. This Data in Brief paper aims to report demographic, clinical, laboratory, echocardiographic, intraprocedural, periprocedural, postprocedural and follow-up data; all of them were prospectively collected from each patient's health record, whereas the analysis was performed retrospectively. Targets of this data analysis were: 1) to evaluate the impact of contrast medium (CM) osmolality on TAVI-related AKI; 2) to identify the most of risk factors involved in the development of such complication, and consequently in the occurrence of 1-year mortality; 3) to estimate the impact of CM osmolality on AKI in specific patient subgroups.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA