Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Stroke Cerebrovasc Dis ; 33(1): 107451, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37995501

RESUMO

OBJECTIVES: Up to 20 % of ischemic strokes are associated with overt atrial fibrillation (AF). Furthermore, silent AF was detected by an implantable cardiac monitor (ICM) in 1 in 3 cryptogenic strokes in the CRYSTAL AF study. An ESC position paper has suggested a HAVOC score ≥ 4 or a Brown ESUS-AF score ≥ 2 as criteria for ICM implantation after cryptogenic stroke, but neither of these criteria has been developed or validated in ICM populations. We assessed the performance of HAVOC and Brown ESUS-AF scores in a cohort of ICM patients implanted after embolic stroke of undetermined source (ESUS). METHODS: All patients implanted with an ICM for ESUS between February 2016 and February 2022 at two French University Hospitals were retrospectively included. Demographic data, cardiovascular risk factors, and clinical and biological data were collected after a review of electronic medical records. HAVOC and Brown ESUS-AF scores were calculated for all patients. FINDINGS: Among the 384 patients included, 106 (27 %) developed AF during a mean follow-up of 33 months. The scores performances for predicting AF during follow-up were: HAVOC= AUC: 68.5 %, C-Index: 0.662, and Brown ESUS-AF=AUC: 72.9 %, C-index 0.712. Compared with the CHA2DS2-VASc score, only the Brown ESUS-AF score showed significant improvement in NRI/IDI. Furthermore, classifying patients according to the suggested HAVOC and Brown ESUS-AF thresholds, only 24 % and 31 % of the cohort, respectively, would have received an ICM, and 58 (55 %) and 47 (44 %) of the AF patients, respectively, would not have been implanted with an ICM. CONCLUSION: HAVOC and Brown ESUS-AF scores showed close and moderate performance in predicting AF on ICM after cryptogenic stroke, with a significant lack of sensitivity. Specific risk scores should be developed and validated in large ICM cohorts.


Assuntos
Fibrilação Atrial , AVC Embólico , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/terapia , AVC Embólico/complicações , Estudos Retrospectivos , Fatores de Risco , AVC Isquêmico/complicações
2.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36938977

RESUMO

AIMS: In a recent position paper, the European Heart Rhythm Association (EHRA) proposed an algorithm for the screening and management of arrhythmias using digital devices. In patients with prior stroke, a systematic screening approach for atrial fibrillation (AF) should always be implemented, preferably immediately after the event. Patients with increasing age and with specific cardiovascular or non-cardiovascular comorbidities are also deemed to be at higher risk. From a large nationwide database, the aim was to analyse AF incidence rates derived from this new EHRA algorithm. METHODS AND RESULTS: Using the French administrative hospital discharge database, all patients hospitalized in 2012 without a history of AF, and with at least a 5-year follow-up (FU) (or if they died earlier), were included. The yearly incidence of AF was calculated in each subgroup defined by the algorithm proposed by EHRA based on a history of previous stroke, increasing age, and eight comorbidities identified via International Classification of Diseases 10th Revision codes. Out of the 4526 104 patients included (mean age 58.9 ± 18.9 years, 64.5% women), 1% had a history of stroke. Among those with no history of stroke, 18% were aged 65-74 years and 21% were ≥75 years. During FU, 327 012 patients had an incidence of AF (yearly incidence 1.86% in the overall population). Implementation of the EHRA algorithm divided the population into six risk groups: patients with a history of stroke (group 1); patients > 75 years (group 2); patients aged 65-74 years with or without comorbidity (groups 3a and 3b); and patients < 65 years with or without comorbidity (groups 4a and 4b). The yearly incidences of AF were 4.58% per year (group 2), 6.21% per year (group 2), 3.50% per year (group 3a), 2.01% per year (group 3b), 1.23% per year (group 4a), and 0.35% per year (group 4b). In patients aged < 65 years, the annual incidence of AF increased progressively according to the number of comorbidities from 0.35% (no comorbidities) to 9.08% (eight comorbidities). For those aged 65-75 years, the same trend was observed, i.e. increasing from 2.01% (no comorbidities) to 11.47% (eight comorbidities). CONCLUSION: These findings at a nationwide scale confirm the relevance of the subgroups in the EHRA algorithm for identifying a higher risk of AF incidence, showing that older patients (>75 years, regardless of comorbidities) have a higher incidence of AF than those with prior ischaemic stroke. Further studies are needed to evaluate the usefulness of algorithm-based risk stratification strategies for AF screening and the impact of screening on major cardiovascular event rates.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/complicações , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Incidência , Isquemia Encefálica/epidemiologia , Comorbidade , Fatores de Risco
3.
N Engl J Med ; 390(11): 1054-1055, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38477997
4.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-34974497

RESUMO

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Coração Auxiliar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Resultado do Tratamento
5.
Rev Cardiovasc Med ; 22(3): 1063-1072, 2021 09 24.
Artigo em Inglês | MEDLINE | ID: mdl-34565108

RESUMO

We evaluated the age-specific mortality of unselected adult outpatients infected with SARS-CoV-2 treated early in a dedicated COVID-19 day hospital and we assessed whether the use of hydroxychloroquine (HCQ) + azithromycin (AZ) was associated with improved survival in this cohort. A retrospective monocentric cohort study was conducted in the day hospital of our center from March to December 2020 in adults with PCR-proven infection who were treated as outpatients with a standardized protocol. The primary endpoint was 6-week mortality, and secondary endpoints were transfer to the intensive care unit and hospitalization rate. Among 10,429 patients (median age, 45 [IQR 32-57] years; 5597 [53.7%] women), 16 died (0.15%). The infection fatality rate was 0.06% among the 8315 patients treated with HCQ+AZ. No deaths occurred among the 8414 patients younger than 60 years. Older age and male sex were associated with a higher risk of death, ICU transfer, and hospitalization. Treatment with HCQ+AZ (0.17 [0.06-0.48]) was associated with a lower risk of death, independently of age, sex and epidemic period. Meta-analysis evidenced consistency with 4 previous outpatient studies (32,124 patients-Odds ratio 0.31 [0.20-0.47], I2 = 0%). Early ambulatory treatment of COVID-19 with HCQ+AZ as a standard of care is associated with very low mortality, and HCQ+AZ improve COVID-19 survival compared to other regimens.


Assuntos
Assistência Ambulatorial , Antivirais/uso terapêutico , Azitromicina/uso terapêutico , Tratamento Farmacológico da COVID-19 , Intervenção Médica Precoce , Hidroxicloroquina/uso terapêutico , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Antivirais/efeitos adversos , Azitromicina/efeitos adversos , COVID-19/diagnóstico , COVID-19/mortalidade , Quimioterapia Combinada , Feminino , França , Hospitalização , Humanos , Hidroxicloroquina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
Purinergic Signal ; 15(1): 45-52, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30535950

RESUMO

The mechanism of atrial fibrillation (AF) in patients with normal heart remains unclear. While exogenous adenosine can trigger AF, nothing is known about the behavior of endogenous adenosine plasma level (APL) at the onset of AF and during ablation procedure. Ninety-one patients (68 with paroxysmal AF: 40 males, 66 ± 16 years; 23 with persistent AF: 14 males, 69 ± 11 years) and 18 controls were included. Among paroxysmal patients: i) medical therapy alone was performed in 45 cases and ablation procedure in 23. AF was spontaneously resolutive in 6 cases; ii) 23 underwent ablation procedure and blood was collected simultaneously in a brachial vein and in the left atrium; 17 were spontaneously in sinus rhythm while 6 were in sinus rhythm after direct current cardioversion. Among persistent patients: i) in 17 patients, blood samples were collected in a brachial vein before and after direct current cardioversion; ii) in 6 patients, blood samples were collected simultaneously in a brachial vein and in left atrium before and after cardioversion during ablation procedure. CV-APL was higher in patients with persistent AF vs patients with paroxysmal AF (median [range]: 0.9[0.6-1.1] vs 0.7[0.4-1.1] µM; p < 0.001). In patients with paroxysmal AF, LA-APL increased during the AF episode (0.95[0.85-1.4] vs 2.7[1.5-7] µM; p = 0.03) and normalized in sinus rhythm after DCCV. In patients with persistent AF, LA-APL was higher than CV-APL (1.2[0.7-1.8] vs 0.9[0.6-1.1] µM; p < 0.001), and both normalized in sinus rhythm (CV-APL: 0.8[0.6-1.1] vs 0.75[0.4-1] µM; p = 0.03), (LA-APL: 1.95[1.3-3] vs 1[0.5-1.15] µM; p = 0.03). The occurrence of AF is associated with a strong increase of APL in the atrium. The cause of this increase needs further investigations.


Assuntos
Adenosina/sangue , Fibrilação Atrial/sangue , Idoso , Fibrilação Atrial/terapia , Ablação por Cateter , Cardioversão Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
7.
Heart Vessels ; 34(5): 824-831, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30415372

RESUMO

Infections of cardiac implantable electronic devices (CIEDs) have increased over the past decade. However, the impact of the climate on CIED infections is unknown. To determine whether there is a seasonal variation in CIED infections. In this single-center observational study, retrospective analysis of prospectively collected data was performed. Timone Hospital in Marseille (south-east France) is a tertiary care institution and the regional reference center for management of CIED infections. All consecutive patients with CIED extractions for infectious reasons were included over a 12-year period. We noted the mean temperature (°C), precipitation (mm) and the incidence of CIED infections over this period. Among 612 patients [mean (standard deviation) age, 72.4 (13.0) years; 74.0% male], 238 had endocarditis alone (38.9%), 249 had pocket infection alone (40.7%), and 125 had both (20.4%). We found bacterial documentation in 428 patients (70.0%), commensal in 245 (40.0%). The incidence of CIED infections was positively associated with high temperature (regression coefficient = 0.075; P = 0.01) and precipitation (regression coefficient = 0.022; P < 0.01). Seasonal variation was specific of pocket infections, whether they were associated with endocarditis or not. Subgroups with infection seasonality were: women, elderly people (> 75 years), late CIED infection and skin commensal bacterial infections. We found a seasonal variation in pocket infections, whether associated with endocarditis or not. Infections were associated with elevated temperatures and precipitation. Therefore, specific prevention strategy should be discussed in high-risk patients.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/etiologia , Estações do Ano , Idoso , Idoso de 80 Anos ou mais , Endocardite/epidemiologia , Endocardite/etiologia , Feminino , França/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Atenção Terciária
8.
J Cardiovasc Electrophysiol ; 29(11): 1493-1499, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30230085

RESUMO

INTRODUCTION: Demonstration of exit block after pulmonary vein isolation (PVI) is the cornerstone of ablation for atrial fibrillation (AF). It requires the demonstration of local pulmonary vein (PV) capture and absence of conduction to the atrium but is often challenging due to the inability to see local paced PV-evoked potentials. We retrospectively examined the ability of adenosine to augment this technique during CARTO-based radiofrequency ablation procedures. METHODS: Retrospective analysis of evoked PV potentials during adenosine administration while testing for PV exit block at a single UK center. RESULTS: One hundred and twenty-nine PVs in 33 patients were isolated using radiofrequency energy to demonstrate entry block. Of those, the pacing of 24 veins under baseline conditions did not clearly demonstrate local PV-evoked potentials sufficient to be sure that the local vein was truly captured and dissociated from the atrium. Adenosine was administered in 19 of these, with 10 of 19 (52.6%) veins then demonstrating clear local PV-evoked potentials transiently during adenosine administration, sufficient to allow assessment of definite exit block. CONCLUSION: Adenosine administered during PV pacing allows transient visualization of local PV-evoked potentials after PVI facilitating the clearer demonstration of PV exit block in over 50% veins.


Assuntos
Adenosina/administração & dosagem , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/efeitos dos fármacos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Humanos , Estudos Retrospectivos
9.
J Cardiovasc Electrophysiol ; 29(6): 881-888, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29505684

RESUMO

INTRODUCTION: The ConfiDENSE™ module (Carto3 v4) allows rapid annotation of endocardial electrograms acquired by multielectrode (ME) mapping. However, its accuracy in assessing atrial voltages is unknown. METHODS AND RESULTS: Two ConfiDENSE™ left atrial voltage maps were created during continuous pacing in 20 patients undergoing catheter ablation for persistent AF using a ME lasso catheter and a contact force (CF) sensing ablation catheter. The automated tissue proximity indicator (TPI) filter was then applied to the ME map to yield a TPI map. Reference maps (RM) were created offline by a blinded observer by manually assessing all points against fidelity criteria. Bipolar voltages and proportion of low voltage points (< 0.5 mV) derived from the ME, CF, and TPI maps were compared with those derived from the RM. Note that 853 ± 365 points, 252 ± 184 points, and 144 ± 73 were collected for ME, TPI, and CF maps, respectively, and 429 ± 153 points were included in the RM. Voltages with CF and TPI maps were similar to those with RM (1.57 ± 0.47 mV vs. 1.63 ± 0.31 mV, P = 0.57 and 1.50 ± 0.38 mV vs. 1.63 ± 0.31 mV, P = 0.07, respectively), whereas ME maps showed a significantly lower mean voltage (1.00 ± 0.22 mV, P < 0.001). As compared to RM maps (17 ± 8%), low voltage points were significantly overestimated by the ME maps (50 ± 9% (P < 0.001) and TPI maps (28 ± 13% (P < 0.001), but not by the CF maps (22 ± 14%, P = 0.17). CONCLUSION: Application of the TPI filter to ConfiDENSE maps significantly increases the quality of the voltage data, conserving a reasonable point density, but still overestimates low voltage points as compared to CF-sensing maps or maps reviewed manually.


Assuntos
Potenciais de Ação , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Veias Pulmonares/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial , Ablação por Cateter , Eletrodos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Veias Pulmonares/cirurgia , Reprodutibilidade dos Testes , Fatores de Tempo
10.
Europace ; 20(4): e42-e50, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28582500

RESUMO

Aims: Reimplantation of cardiac implantable electronic devices (CIEDs) after extraction due to device infection is a major issue in pacemaker-dependent patients. We compared in-hospital and long-term outcomes with two techniques: epicardial reimplantation (EPI) before CIED extraction and temporary pacing (TP) with a view to delayed endocardial reimplantation. Methods and results: Two cohorts of consecutive pacemaker-dependent patients who underwent transvenous lead extraction at our tertiary centre were included in this retrospective cohort study. According to successive policies, either the EPI or the TP approach was used. In-hospital complications occurred at similar rates in the EPI (n = 59) and TP (n = 52) cohorts (37.3% vs. 32.7%, respectively; P = 0.61). Thirteen (25.0%) patients in the TP cohort eventually were reimplanted epicardially, mainly because of infection of the temporary lead. Finally, 65 patients were discharged with an epicardial device and 37 with an endocardial device. Median follow-up was 41.7 (interquartile range 34.1-51.5) months. No difference was observed in long-term mortality according to the reimplantation strategy, but use of TP was associated with a reduced risk of late endocarditis and device reintervention (hazard ratio (HR) 0.25, 95% confidence interval (CI) 0.09-0.069, P = 0.01), whereas epicardial device reimplantation was associated with an increased risk (HR 3.62, 95% CI 1.07-12.21, P = 0.04). Conclusion: We observed similar in-hospital outcomes in our EPI and TP cohorts. Twenty-five percent of the patients initially paced by a TP strategy finally needed an epicardial device, mainly because of infection of their TP lead. Use of TP resulted in lower rates of late endocarditis and device reintervention.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Endocárdio/cirurgia , Marca-Passo Artificial/efeitos adversos , Pericárdio/cirurgia , Implantação de Prótese/métodos , Infecções Relacionadas à Prótese/cirurgia , Estimulação Cardíaca Artificial , Endocárdio/fisiopatologia , Hospitalização , Humanos , Pericárdio/fisiopatologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 41(9): 1071-1077, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29947109

RESUMO

PURPOSE: Ablation of premature ventricular complexes (PVCs) originating from left-sided papillary muscles is challenging. We tested a new approach by performing high-density mapping of PVC. METHODS AND RESULTS: We used a 20-pole deflectable spiral catheter during ablation procedures in four consecutive patients. Three presented with mitral valve prolapse, one with dilated cardiomyopathy. PVC burden was 24 ± 13%. The procedures lasted 182 ± 55.4 minutes, including 10 ± 3.2 minutes of radiofrequency. In all patients, mapping evidenced internal primary activation relative to the left ventricle shell (mean distance 21.3 ± 5.1 mm). Endocavitary prematurity was -38.3 ± 4.8 ms. Primary ablation success was achieved for all patients. CONCLUSIONS: High-density mapping of the papillary muscles in the left ventricle using a spiral catheter may be feasible. We identified the PVC foci away from the left ventricular shell. This consolidates the assumption for the origin of these ectopic beats at the junction between the chordae tendineae and the papillary muscles.


Assuntos
Músculos Papilares/cirurgia , Ablação por Radiofrequência/métodos , Complexos Ventriculares Prematuros/cirurgia , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/cirurgia , Ecocardiografia , Eletrocardiografia Ambulatorial , Mapeamento Epicárdico , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Prolapso da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/cirurgia , Músculos Papilares/fisiopatologia , Resultado do Tratamento , Complexos Ventriculares Prematuros/fisiopatologia
12.
Europace ; 19(10): 1710-1716, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27733470

RESUMO

AIMS: We sought to compare outcomes and costs of a stepwise approach to transvenous lead extraction (TLE) involving laser-assisted sheaths or mechanical polypropylene sheaths, with/without crossover. METHODS AND RESULTS: We prospectively included patients who underwent TLE (between August 2013 and December 2014) as part of a stepwise approach involving simple traction, lead snaring, and sheath-assisted dissection; all of these patients underwent a first-line polypropylene-sheath-extraction approach (Group A). The comparison group (Group B) was consecutive patients who had undergone TLE before August 2013, during which laser-assisted sheath extraction was the first-line approach. The number of patients in Group B was adjusted to match the number who eventually needed sheaths in Group A. Procedural data, outcomes, and costs were compared between groups (comparison of approaches) and in patients who needed sheath-assisted extraction (comparison of techniques). Overall, 521 leads were extracted (131 patients in Group A, 104 in Group B). Radiological and clinical success rates were similar; crossover from polypropylene to laser sheaths was needed in 10 patients in Group A (vs. none in Group B). Radiological (P< 0.001) and clinical (P= 0.01) success rates were higher and were achieved with a lower radiation exposure (P= 0.03) with laser sheaths in patients (60 in each group) who needed sheath-assisted extraction. Complication rates were similar in both groups (P= 0.66) but two deaths occurred in Group B. The laser approach had higher material cost (P= 0.002). CONCLUSIONS: Although laser-assisted TLE was more effective than polypropylene sheath-assisted TLE, the latter was associated with fewer complications and was more cost-effective.


Assuntos
Cateterismo Cardíaco/economia , Desfibriladores Implantáveis , Remoção de Dispositivo/economia , Custos de Cuidados de Saúde , Terapia a Laser/economia , Marca-Passo Artificial , Avaliação de Processos em Cuidados de Saúde/economia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos/economia , Análise Custo-Benefício , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/instrumentação , Remoção de Dispositivo/métodos , Desenho de Equipamento , Feminino , França , Humanos , Terapia a Laser/efeitos adversos , Terapia a Laser/instrumentação , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Polipropilenos/economia , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação/economia , Radiografia Intervencionista/economia , Fatores de Tempo , Resultado do Tratamento
13.
Front Cardiovasc Med ; 11: 1361761, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572304

RESUMO

Background and aims: Right phrenic nerve palsy is the most frequent complication of cryoballoon procedures. The SMARTFREEZE™ console (Boston Scientific, St. Paul, MN, USA) has integrated a new tool for diaphragm monitoring-the Diaphragm Movement Sensor; however, it has not been evaluated in clinical practice. We aimed to assess the diagnostic performance of the Diaphragm Movement Sensor based on compound motor action potential data recorded simultaneously. Methods: Thirty consecutive patients (mean age 63.2 ± 10.2 years) were included. We simultaneously recorded the compound motor action potential and the Diaphragm Movement Sensor during cryoapplications in the right pulmonary veins. The right phrenic nerve was paced at 60 per minute, 12 V and 2.9 ms. Compound motor action potential monitoring with a 30% decrease cutoff for the diagnosis of phrenic nerve threatening was considered the gold standard. The Diaphragm Movement Sensor decrease threshold was also set at 30%. Results: Considering compound motor action potential monitoring, phrenic nerve threatening occurred 11 times (in seven patients) among 84 cryoapplications (13.1%) at the right pulmonary veins. The sensitivity and specificity of the Diaphragm Movement Sensor were, respectively, 33% (95% CI: 7%-70%) and 49% (95% CI: 38%-61%; P < 0.001). The predictive positive and negative values for the Diaphragm Movement Sensor were, respectively, 7% (95% CI: 2%-20%) and 86% (95% CI: 72%-95%). The Diaphragm Movement Sensor gave an erroneous diagnosis in 44/84 cryoapplications (52.4%). Conclusions: The diagnostic performance of the Diaphragm Movement Sensor is low, and the relevance of its use in clinical practice may be debated.

14.
Mayo Clin Proc ; 99(5): 754-765, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38180394

RESUMO

OBJECTIVE: To compare outcomes after left atrial appendage occlusion (LAAO) via implanted device vs no LAAO in a matched cohort of patients with atrial fibrillation (AF). METHODS: This longitudinal retrospective cohort study was based on the national database covering hospital care for the entire French population. Adults (≥18 years of age) who had been hospitalized with AF (January 1, 2015, to January 1, 2020) who underwent LAAO were identified. Propensity score matching was used to control for potential confounders of the treatment-outcome relationship. The primary outcome was a composite of ischemic stroke, major bleeding, or all-cause death during follow-up. RESULTS: After propensity score matching, 1216 patients with AF who were treated with LAAO were matched with 1216 controls (patients AF who were not treated with LAAO). Mean follow-up was 14.5 months (median, 13 months; IQR, 7-21 months). Patients with LAAO had a lower risk of the composite outcome (HR, 0.48; 95% CI, 0.42 to 0.55). Total events (309 for LAAO vs 640 for controls) and event rates (23.3% vs 44.0%/year, respectively) were lower for LAAO, driven primarily by a decreased risk of all-cause death (HR, 0.39; 95% CI, 0.33 to 0.46; P<.0001), whereas ischemic stroke risk was higher (HR, 1.75; 95% CI, 1.17 to 2.64). Significant interactions were observed in subgroups with a history of ischemic stroke (P<.001) and of bleeding (P=.002). CONCLUSION: Among AF patients at high bleeding risk, our nationwide study highlights a high risk of clinical events during follow-up. LAAO appeared less effective than no LAAO in preventing stroke but more effective in preventing death. Left atrial appendage occlusion is particularly effective in patients with previous ischemic stroke or any episode of bleeding.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Masculino , Feminino , Idoso , Estudos Retrospectivos , Pontuação de Propensão , Estudos Longitudinais , Pessoa de Meia-Idade , Resultado do Tratamento , Dispositivo para Oclusão Septal , AVC Isquêmico/prevenção & controle , AVC Isquêmico/etiologia , AVC Isquêmico/epidemiologia , Idoso de 80 Anos ou mais , França/epidemiologia
15.
Cells ; 12(16)2023 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-37626837

RESUMO

Although very common, the precise mechanisms that explain the symptomatology of neuroendocrine syncope (NES) remain poorly understood. This disease, which can be very incapacitating, manifests itself as a drop in blood pressure secondary to vasodilation and/or extreme slowing of heart rate. As studies continue, the involvement of the adenosinergic system is becoming increasingly evident. Adenosine, which is an ATP derivative, may be involved in a large number of cases. Adenosine acts on G protein-coupled receptors with seven transmembrane domains. A1 and A2A adenosine receptor dysfunction seem to be particularly implicated since the activation leads to severe bradycardia or vasodilation, respectively, two cardinal symptoms of NES. This mini-review aims to shed light on the links between dysfunction of the adenosinergic system and NHS. In particular, signal transduction pathways through the modulation of cAMP production and ion channels in relation to effects on the cardiovascular system are addressed. A better understanding of these mechanisms could guide the pharmacological development of new therapeutic approaches.


Assuntos
Adenosina , Síncope , Animais , Anuros , Pressão Sanguínea , Frequência Cardíaca
16.
Circ Arrhythm Electrophysiol ; 16(3): e011354, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802906

RESUMO

BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do Tratamento
17.
Eur Heart J Acute Cardiovasc Care ; 12(9): 571-581, 2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37319361

RESUMO

AIMS: Heart transplantation (HT) can be proposed as a therapeutic strategy for patients with severe refractory electrical storm (ES). Data in the literature are scarce and based on case reports. We aimed at determining the characteristics and survival of patients transplanted for refractory ES. METHODS AND RESULTS: Patients registered on HT waiting list during the following days after ES and eventually transplanted, from 2010 to 2021, were retrospectively included in 11 French centres. The primary endpoint was in-hospital mortality. Forty-five patients were included [82% men; 55.0 (47.8-59.3) years old; 42.2% and 26.7% non-ischaemic dilated or ischaemic cardiomyopathies, respectively]. Among them, 42 (93.3%) received amiodarone, 29 received (64.4%) beta blockers, 19 (42.2%) required deep sedation, 22 had (48.9%) mechanical circulatory support, and 9 (20.0%) had radiofrequency catheter ablation. Twenty-two patients (62%) were in cardiogenic shock. Inscription on wait list and transplantation occurred 3.0 (1.0-5.0) days and 9.0 (4.0-14.0) days after ES onset, respectively. After transplantation, 20 patients (44.4%) needed immediate haemodynamic support by extracorporeal membrane oxygenation (ECMO). In-hospital mortality rate was 28.9%. Predictors of in-hospital mortality were serum creatinine/urea levels, need for immediate post-operative ECMO support, post-operative complications, and surgical re-interventions. One-year survival was 68.9%. CONCLUSION: Electrical storm is a rare indication of HT but may be lifesaving in those patients presenting intractable arrhythmias despite usual care. Most patients can be safely discharged from hospital, although post-operative mortality remains substantial in this context of emergency transplantation. Larger studies are warranted to precisely determine those patients at higher risk of in-hospital mortality.


Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Arritmias Cardíacas/etiologia , Choque Cardiogênico/etiologia , Oxigenação por Membrana Extracorpórea/métodos
18.
J Am Coll Cardiol ; 82(7): 590-599, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37558371

RESUMO

BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapia
20.
Front Cardiovasc Med ; 9: 814026, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35211527

RESUMO

BACKGROUND: Compound motor action potential (CMAP) monitoring is a common method used to prevent right phrenic nerve palsy during cryoballoon ablation for atrial fibrillation. OBJECTIVE: We compared recordings simultaneously obtained with surface and hepatic electrodes. METHODS: We included 114 consecutive patients (mean age 61.7 ± 10.9 years) admitted to our department for cryoballoon ablation. CMAP was monitored simultaneously with a hepatic catheter and a modified lead I ECG, whilst right phrenic nerve was paced before (stage 1) and during (stage 2) the right-sided freezes. If phrenic threat was detected with hepatic recordings (CMAP amplitude drop >30%) the application was discontinued with forced deflation. RESULTS: The ratio of CMAP/QRS was 4.63 (2.67-9.46) for hepatic and 0.76 (0.55-1.14) for surface (p < 0.0001). Signal coefficients of variation during stage 1 were 3.92% (2.48-6.74) and 4.10% (2.85-5.96) (p = 0.2177), respectively. Uninterpretable signals were more frequent on surface (median 10 vs. 0; p < 0.0001). For the 14 phrenic threats, the CMAP amplitude dropped by 35.61 ± 8.27% on hepatic signal and by 33.42 ± 11.58% concomitantly on surface (p = 0.5417). Our main limitation was to achieve to obtain stable phrenic capture (57%). CMAP monitoring was not reliable because of pacing instability in 15 patients (13.16%). A palsy occurred in 4 patients (3.51%) because cryoapplication was halted too late. CONCLUSION: Both methods are feasible with the same signal stability and amplitude drop precocity during phrenic threats. Clarity and legibility are significantly better with hepatic recording (sharper signals, less far-field QRS). The two main limitations were pacing instability and delay between 30% CMAP decrease and cryoapplication discontinuation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA