Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 88(7): 1067-1074, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27259089

RESUMO

BACKGROUND: The Flash Ostial system (Ostial Corporation, Sunnyvale, CA) was designed to optimize implantation of aorto-ostial coronary stents by flaring the proximal stent struts against the aortic wall. METHODS: We retrospectively reviewed the medical record, angiograms, and intravascular ultrasound images of 22 aorto-ostial percutaneous coronary interventions performed at our institution between March and September 2015. The Flash Ostial system was used in 13 cases (59%). RESULTS: Mean age was 67 ± 8 years and all patients were men. The target vessel was the right coronary artery (59%), left main (27%), or a saphenous vein graft (14%); 59% of the lesions had moderate/severe calcification. The mean number of predilation balloons was 1.8 ± 1.6, mean Flash ostial balloon diameter was 3.3 ± 0.5 mm and mean inflation pressure was 13.1 ± 4.0 atmospheres. Intravascular ultrasonography (available for 19 patients) revealed mean ostial minimum lumen cross-sectional area (MLA) of 9.2 ± 3.0 mm2 and reference MLA of 8.5 ± 2.7 mm2 . The percent difference between ostial and reference MLA was higher in cases in which the Flash Ostial system was used versus those where it was not (9.6 ± 5.5% vs. 4.0 ± 2.8%, P = 0.03). All stent struts were well apposed. Technical success was 100%. One patient developed a left groin pseudoaneurysm treated with thrombin injection and one patient had a periprocedural myocardial infarction. Median contrast, fluoroscopy time, and procedure time were 235 mL, 33 min, and 118 min, respectively. CONCLUSIONS: The Flash Ostial system can be successfully used in aorto-ostial stenting, resulting in large ostial vessel MLA. © 2016 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Oclusão de Enxerto Vascular/terapia , Idoso , Falso Aneurisma/tratamento farmacológico , Falso Aneurisma/etiologia , Angioplastia Coronária com Balão/efeitos adversos , Meios de Contraste/administração & dosagem , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento , Fluoroscopia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Veia Safena/diagnóstico por imagem , Veia Safena/transplante , Stents , Texas , Trombina/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
2.
Catheter Cardiovasc Interv ; 81(3): 488-93, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22234940

RESUMO

BACKGROUND: Optical coherence tomography (OCT) and near-infrared spectroscopy (NIRS) allow assessment of the anatomy (OCT) and composition (NIRS) of coronary lesions. We sought to examine the association between pre-stenting lipid core plaque (LCP), as assessed by NIRS and post-stenting thrombus formation, as assessed by OCT. METHODS: We reviewed the angiograms of nine patients who underwent coronary stenting in association with NIRS and OCT imaging. A large LCP by NIRS was defined as at least three 2-mm yellow blocks on the NIRS block chemogram with >200° angular extent. Intracoronary thrombus was defined as a mass of medium reflectivity protruding into the vessel lumen, discontinuous from the surface of the vessel wall. RESULTS: Mean age was 67 ± 7 years, and all patients were men, presenting with stable angina (56%), unstable angina (11%), or acute myocardial infarction (33%). The mean vessel lipid core burden index (LCBI) was 120 ± 45, and the mean highest 6-mm LCBI was 386 ± 190. Three patients had a large LCP and two of them (66%) developed intrastent thrombus after stent implantation compared to none of six patients without large LCPs (0%, P = 0.02). The thrombus resolved after intracoronary glycoprotein IIb/IIIa administration and balloon postdilation. Postprocedural myocardial infarction occurred in 33% versus 17% of patients with and without large LCP, respectively (P = 0.57). CONCLUSION: Stenting of large LCPs may be associated with intrastent thrombus formation, suggesting that more intensive anticoagulant and/or antiplatelet therapy may be beneficial in such lesions. © 2012 Wiley Periodicals, Inc.


Assuntos
Vasos Coronários/química , Oclusão de Enxerto Vascular/diagnóstico , Lipídeos/análise , Placa Aterosclerótica/química , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Stents , Tomografia de Coerência Óptica/métodos , Idoso , Estenose Coronária/cirurgia , Vasos Coronários/patologia , Seguimentos , Oclusão de Enxerto Vascular/metabolismo , Humanos , Masculino , Intervenção Coronária Percutânea , Placa Aterosclerótica/patologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA