Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
G Chir ; 26(8-9): 321-7, 2005.
Artigo em Italiano | MEDLINE | ID: mdl-16329776

RESUMO

Done to the improvement of knowledges in hepatic surgery and postoperative care, hepatocellular carcinoma (HCC) have been treated more and more frequently by hepatic resection. Aim of this study is to report an initial series of patients affected by HCC treated by hepatic resection utilizing a new water-cooled, high-density, monopolar device, the Tissuelink Monopolar Floating Ball (Tissuelink Medical Inc., Dover, NH, U.S.A.), in order to avoid bleeding during hepatic surgery. Sex, age, kind of disease, viral and Child status, type of surgical procedure, in association to lenght of surgical procedure, blood loss, utilization of the vascular clamping of the liver, hospital stay, morbidity and mortality have been analized. Six liver resections have been performed utilizing this new device. No vascular clamping was established except one. No mortality was recorded. Morbidity was ascites in one case and pleural effusion in a second one. In conclusion the Floating Ball reduces the intraoperative bleeding during hepatic resection in patients with HCC.


Assuntos
Carcinoma Hepatocelular/cirurgia , Técnicas Hemostáticas/instrumentação , Hepatectomia , Neoplasias Hepáticas/cirurgia , Idoso , Carcinoma Hepatocelular/complicações , Desenho de Equipamento , Feminino , Humanos , Cirrose Hepática/complicações , Neoplasias Hepáticas/complicações , Masculino
2.
Angiology ; 49(9): 707-21, 1998 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9756422

RESUMO

It is still a matter of debate as to which parameters should be used for noninvasive diagnosis of renovascular disease by renal Doppler sonography (RDS). The accuracy of RDS in the detection of renal artery stenosis (RAS) was tested in 95 consecutive, moderate to severe hypertensive patients (I-II World Health Organization [WHO] stages). Reno-aortic ratio (RAR) for peak systolic velocity (PSV) was also calculated to assist in the diagnosis of significant (>50%) RAS. Paired receiver-operating characteristic (ROC) analysis was plotted for evaluating the relationship between sensitivity and specificity for each parameter. In a subset of 57 kidneys, the influence of blood pressure and age on intraparenchymal parameters was evaluated. Measurements of maximal peak systolic velocity (PSV) at the site of stenosis, RAR for PSV, and minimum acceleration index in the main renal artery showed high accuracy (areas under the ROC curve 0.97, 0.88, and 0.80, respectively). Among intraparenchymal parameters, early systolic acceleration showed the best area under the ROC curve (0.90), but provided a low positive predictive value (29%) and was significantly influenced by blood pressure (multiple r=0.56; p=0.001). Pulsatility and resistive indices were found to be less powerful as absolute values, and both significantly influenced by blood pressure and age (multiple r=0.60 and 0.50; p=0.001, p=0.02, respectively). However, interindividual variance of intrarenal indices should be minimized by calculation of side difference, although this procedure would become misleading or impossible in patients with bilateral RAS or a single kidney, respectively. These results support the use of extraparenchymal parameters for noninvasive detection of RAS, and emphasize that intrarenal parameters cannot be considered as absolute values.


Assuntos
Hipertensão Renovascular/diagnóstico por imagem , Obstrução da Artéria Renal/diagnóstico por imagem , Ultrassonografia Doppler , Adulto , Idoso , Pressão Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fluxo Pulsátil , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA