Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Infect Immun ; 86(5)2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29483293

RESUMO

This study investigated the host response to a polymicrobial pulpal infection consisting of Streptococcus anginosus and Enterococcus faecalis, bacteria commonly implicated in dental abscesses and endodontic failure, using a validated ex vivo rat tooth model. Tooth slices were inoculated with planktonic cultures of S. anginosus or E. faecalis alone or in coculture at S. anginosus/E. faecalis ratios of 50:50 and 90:10. Attachment was semiquantified by measuring the area covered by fluorescently labeled bacteria. Host response was established by viable histological cell counts, and inflammatory response was measured using reverse transcription-quantitative PCR (RT-qPCR) and immunohistochemistry. A significant reduction in cell viability was observed for single and polymicrobial infections, with no significant differences between infection types (∼2,000 cells/mm2 for infected pulps compared to ∼4,000 cells/mm2 for uninfected pulps). E. faecalis demonstrated significantly higher levels of attachment (6.5%) than S. anginosus alone (2.3%) and mixed-species infections (3.4% for 50:50 and 2.3% for 90:10), with a remarkable affinity for the pulpal vasculature. Infections with E. faecalis demonstrated the greatest increase in tumor necrosis factor alpha (TNF-α) (47.1-fold for E. faecalis, 14.6-fold for S. anginosus, 60.1-fold for 50:50, and 25.0-fold for 90:10) and interleukin 1ß (IL-1ß) expression (54.8-fold for E. faecalis, 8.8-fold for S. anginosus, 54.5-fold for 50:50, and 39.9-fold for 90:10) compared to uninfected samples. Immunohistochemistry confirmed this, with the majority of inflammation localized to the pulpal vasculature and odontoblast regions. Interestingly, E. faecalis supernatant and heat-killed E. faecalis treatments were unable to induce the same inflammatory response, suggesting E. faecalis pathogenicity in pulpitis is linked to its greater ability to attach to the pulpal vasculature.


Assuntos
Coinfecção/patologia , Enterococcus faecalis/patogenicidade , Interações Hospedeiro-Parasita , Pulpite/microbiologia , Pulpite/fisiopatologia , Ratos/microbiologia , Streptococcus anginosus/patogenicidade , Animais , Modelos Animais
2.
BMC Anesthesiol ; 17(1): 36, 2017 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-28257624

RESUMO

BACKGROUND: Aspiration of subglottic secretions past the endotracheal tube (ETT) cuff is a prerequisite for developing ventilator-associated pneumonia (VAP). Subglottic secretion drainage (SSD) ETTs reduce aspiration of subglottic secretions and have demonstrated lower VAP rates. We compared the performance of seven SSD ETTs against a non-SSD ETT in preventing aspiration below inflated cuffs. METHODS: ETTs were positioned vertically in 2 cm diameter cylinders. Four ml of a standard microbial suspension was added above inflated cuffs. After 1 h, aspiration was measured and ETTs demonstrating no leakage were subjected to rotational movement and evaluation over 24 h. Collected aspirated fluid was used to inoculate agar media and incubated aerobically at 37 °C for 24 h. The aspiration rate, volume and number of microorganisms that leaked past the cuff was measured. Experiments were repeated (×10) for each type of ETT, with new ETTs used for each repeat. Best performing ETTs were then tested in five different cylinder diameters (1.6, 1.8, 2.0, 2.2 and 2.4 cm). Experiments were repeated as above using sterile water. Volume and time taken for aspiration past the cuff was measured. Experiments were repeated (×10) for each type of ETT. Results were analysed using non-parametric tests for repeated measures. RESULTS: The PneuX ETT prevented aspiration past the cuff in all experiments. All other ETTs allowed aspiration, with considerable variability in performance. The PneuX ETT was statistically superior in reducing aspiration compared to the SealGuard (p < 0.009), KimVent (p < 0.002), TaperGuard (p < 0.004), Lanz (p < 0.001), ISIS (p < 0.001), SACETT (p < 0.001) and Soft Seal (p < 0.001) ETTs. Of the 4 ETTs tested in differing cylinder sizes, the PneuX significantly reduced aspiration across the range of diameters compared to the SealGuard (p < 0.0001), TaperGuard (p < 0.0001) and KimVent (p < 0.0001) ETTs. CONCLUSIONS: ETTs showed substantial variation in fluid aspiration, relating to cuff material and design. Variability in performance was likely due to the random manner in which involutional folds form in the inflated ETT cuff. The PneuX ETT was the only ETT able to consistently prevent aspiration past the cuff in all experiments.


Assuntos
Intubação Intratraqueal/instrumentação , Modelos Biológicos , Paracentese/instrumentação , Desenho de Equipamento , Humanos , Técnicas In Vitro , Pneumonia Aspirativa/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA