RESUMO
AIMS: Patients with atrial fibrillation frequently experience sleep disorder breathing, and both conditions are highly prevalent in presence of heart failure (HF). We explored the association between the combination of an HF and a sleep apnoea (SA) index and the incidence of atrial high-rate events (AHRE) in patients with implantable defibrillators (ICDs). METHODS AND RESULTS: Data were prospectively collected from 411 consecutive HF patients with ICD. The IN-alert HF state was measured by the multi-sensor HeartLogic Index (>16), and the ICD-measured Respiratory Disturbance Index (RDI) was computed to identify severe SA. The endpoints were as follows: daily AHRE burden of ≥5 min, ≥6 h, and ≥23 h. During a median follow-up of 26 months, the time IN-alert HF state was 13% of the total observation period. The RDI value was ≥30 episodes/h (severe SA) during 58% of the observation period. An AHRE burden of ≥5 min/day was documented in 139 (34%) patients, ≥6 h/day in 89 (22%) patients, and ≥23 h/day in 68 (17%) patients. The IN-alert HF state was independently associated with AHRE regardless of the daily burden threshold: hazard ratios from 2.17 for ≥5 min/day to 3.43 for ≥23 h/day (P < 0.01). An RDI ≥ 30 episodes/h was associated only with AHRE burden ≥5 min/day [hazard ratio 1.55 (95% confidence interval: 1.11-2.16), P = 0.001]. The combination of IN-alert HF state and RDI ≥ 30 episodes/h accounted for only 6% of the follow-up period and was associated with high rates of AHRE occurrence (from 28 events/100 patient-years for AHRE burden ≥5 min/day to 22 events/100 patient-years for AHRE burden ≥23 h/day). CONCLUSIONS: In HF patients, the occurrence of AHRE is independently associated with the ICD-measured IN-alert HF state and RDI ≥ 30 episodes/h. The coexistence of these two conditions occurs rarely but is associated with a very high rate of AHRE occurrence. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.
Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Síndromes da Apneia do Sono , Humanos , Desfibriladores Implantáveis/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Medição de Risco , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapiaRESUMO
BACKGROUND: In heart failure (HF) patients, atrial fibrillation (AF) is associated with a worse prognosis. Implantable cardioverter-defibrillator (ICD) diagnostics allow continuous monitoring of AF and are equipped with algorithms for HF monitoring. OBJECTIVE: We evaluated the association between the values of the multisensor HF HeartLogic index and the incidence of AF, and assessed the performance of the index in detecting follow-up periods of significantly increased AF risk. METHODS: The HeartLogic feature was activated in 568 ICD patients. Median follow-up was 25 months [25th-75th percentile (15-35)]. The HeartLogic algorithm calculates a daily HF index and identifies periods of IN-alert state on the basis of a configurable threshold. The endpoints were daily AF burden ≥5 minutes, ≥6 hours, and ≥23 hours. RESULTS: The HeartLogic index crossed the threshold value 1200 times. AF burden ≥5 minutes/day was documented in 183 patients (32%), ≥6 hours/day in 118 patients (21%), and ≥23 hours/day in 89 patients (16%). The weekly time of IN-alert state was independently associated with AF burden ≥5 minutes/day (hazard ratio [HR] 1.95; 95% confidence interval [CI] 1.22-3.13; P = .005), ≥6 hours/day (HR 2.66; 95% CI 1.60-4.44; P <.001), and ≥23 hours/day (HR 3.32; 95% CI 1.83-6.02; P <.001), after correction for baseline confounders. Comparison of the episode rates in the IN-alert state with those in the OUT-of-alert state yielded HR ranging from 1.57 to 3.11 for AF burden from ≥5 minutes to ≥23 hours. CONCLUSIONS: The HeartLogic alert state was independently associated with AF occurrence. The intervals of time defined by the algorithm as periods of increased risk of HF allow risk stratification of AF according to various thresholds of daily burden.
Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Algoritmos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Monitorização FisiológicaRESUMO
BACKGROUND: The remote device management (RM) is recommended for patients with cardiac implantable electronic devices (CIEDs). RM underutilization is frequently driven by the lack of correct system activation. The MyLATITUDE Patient App (Boston Scientific) has been developed to encourage patient compliance with RM by providing information on communicator setup, troubleshooting, and connection status of the communicator. METHODS: At 14 centers, patients with CIEDs were invited to download and install the App on a mobile device. After 3 months, patients were asked to complete an ad hoc questionnaire to evaluate their experience. RESULTS: The App was proposed to 242 consecutive patients: 81 before RM activation, and 161 during follow-up. The App was successfully installed by 177 (73%) patients. The time required for activation of the communicator and the need for additional support were similar between patients who followed the indications provided by the App and those who underwent standard in-clinic training. During follow-up, notifications of lack of connection were received by 20 (11%) patients and missed transmission by 22 (12%). The median time from notification to resolution was 2 days. After 3 months, 175 (99%) communicators of the 177 patients who installed the App were in "Monitored" status versus 113 (94%) of 120 patients without the App installed (p=0.033). The use of the app made 84% of patients feel reassured. CONCLUSIONS: The App was well accepted by CIED patients and offered support for communicator management and installation. Its use enabled patients to remain connected with greater continuity during follow-up.