Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39352423

RESUMO

PURPOSE: To assess the trends in administered 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) doses, computed tomography (CT) radiation doses, and image quality over the last 15 years in children with drug-resistant epilepsy (DRE) undergoing hybrid positron emission tomography (PET) brain scans. METHODS: We retrospectively analyzed data from children with DRE who had [18F]FDG-PET/CT or magnetic resonance scans for presurgical evaluation between 2005 and 2021. We evaluated changes in injected [18F]FDG doses, administered activity per body weight, CT dose index volume (CTDIvol), and dose length product (DLP). PET image quality was assessed visually by four trained raters. Conversely, CT image quality was measured using region-of-interest analysis, normalized by signal-to-noise (SNR) and contrast-to-noise ratio (CNR). RESULTS: We included 55 children (30 male, mean age: 9 ± 6 years) who underwent 61 [18F]FDG-PET scans (71% as PET/CT). Annually, the injected [18F]FDG dose decreased by ~ 1% (95% CI: 0.92%-0.98%, p < 0.001), with no significant changes in administered activity per body weight (p = 0.51). CTDIvol and DLP decreased annually by 16% (95% CI: 9%-23%) and 15% (95% CI: 8%-21%, both p < 0.001), respectively. PET image quality improved by 9% year-over-year (95% CI: 6%-13%, p < 0.001), while CT-associated SNR and CNR decreased annually by 7% (95% CI: 3%-11%, p = 0.001) and 6% (95% CI: 2%-10%, p = 0.008), respectively. CONCLUSION: Our findings indicate stability in [18F]FDG administered activity per body weight alongside improvements in PET image quality. Conversely, CT-associated radiation doses reduced. These results reaffirm [18F]FDG-PET as an increasingly safer and higher-resolution auxiliary imaging modality for children with DRE. These improvements, driven by technological advancements, may enhance the diagnostic precision and patient outcomes in pediatric epilepsy surgery.

2.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37644149

RESUMO

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons/métodos , Fluordesoxiglucose F18 , Fígado/diagnóstico por imagem , Algoritmos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Imagens de Fantasmas
3.
Eur Radiol ; 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37855853

RESUMO

OBJECTIVES: To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS: Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3 volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS: Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS: Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT: Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS: • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation.

4.
Eur Radiol ; 33(6): 3832-3838, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36480026

RESUMO

BACKGROUND: Deep learning image reconstructions (DLIR) have been recently introduced as an alternative to filtered back projection (FBP) and iterative reconstruction (IR) algorithms for computed tomography (CT) image reconstruction. The aim of this study was to evaluate the effect of DLIR on image quality and quantification of coronary artery calcium (CAC) in comparison to FBP. METHODS: One hundred patients were consecutively enrolled. Image quality-associated variables (noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)) as well as CAC-derived parameters (Agatston score, mass, and volume) were calculated from images reconstructed by using FBP and three different strengths of DLIR (low (DLIR_L), medium (DLIR_M), and high (DLIR_H)). Patients were stratified into 4 risk categories according to the Coronary Artery Calcium - Data and Reporting System (CAC-DRS) classification: 0 Agatston score (very low risk), 1-99 Agatston score (mildly increased risk), Agatston 100-299 (moderately increased risk), and ≥ 300 Agatston score (moderately-to-severely increased risk). RESULTS: In comparison to standard FBP, increasing strength of DLIR was associated with a significant and progressive decrease of image noise (p < 0.001) alongside a significant and progressive increase of both SNR and CNR (p < 0.001). The use of incremental levels of DLIR was associated with a significant decrease of Agatston CAC score and CAC volume (p < 0.001), while mass score remained unchanged when compared to FBP (p = 0.232). The underestimation of Agatston CAC led to a CAC-DRS misclassification rate of 8%. CONCLUSION: DLIR systematically underestimates Agatston CAC score. Therefore, DLIR should be used cautiously for cardiovascular risk assessment. KEY POINTS: • In coronary artery calcium imaging, the implementation of deep learning image reconstructions improves image quality, by decreasing the level of image noise. • Deep learning image reconstructions systematically underestimate Agatston coronary artery calcium score. • Deep learning image reconstructions should be used cautiously in clinical routine to measure Agatston coronary artery calcium score for cardiovascular risk assessment.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cálcio , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação
5.
J Nucl Cardiol ; 30(1): 313-320, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35301677

RESUMO

BACKGROUND: To assess the accuracy of fully automated deep learning (DL) based coronary artery calcium scoring (CACS) from non-contrast computed tomography (CT) as acquired for attenuation correction (AC) of cardiac single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI). METHODS AND RESULTS: Patients were enrolled in this study as part of a larger prospective study (NCT03637231). In this study, 56 Patients who underwent cardiac SPECT-MPI due to suspected coronary artery disease (CAD) were prospectively enrolled. All patients underwent non-contrast CT for AC of SPECT-MPI twice. CACS was manually assessed (serving as standard of reference) on both CT datasets (n = 112) and by a cloud-based DL tool. The agreement in CAC scores and CAC score risk categories was quantified. For the 112 scans included in the analysis, interscore agreement between the CAC scores of the standard of reference and the DL tool was 0.986. The agreement in risk categories was 0.977 with a reclassification rate of 3.6%. Heart rate, image noise, body mass index (BMI), and scan did not significantly impact (p=0.09 - p=0.76) absolute percentage difference in CAC scores. CONCLUSION: A DL tool enables a fully automated and accurate estimation of CAC scores in patients undergoing non-contrast CT for AC of SPECT-MPI.


Assuntos
Doença da Artéria Coronariana , Aprendizado Profundo , Imagem de Perfusão do Miocárdio , Humanos , Cálcio , Imagem de Perfusão do Miocárdio/métodos , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
6.
J Nucl Cardiol ; 30(2): 616-625, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35819716

RESUMO

BACKGROUND: Positron emission tomography (PET) myocardial perfusion imaging (MPI) can be used to evaluate left ventricular (LV) volumes and function. We performed a head-to-head comparison of LV function and volumes obtained simultaneously using [13N]-ammonia-PET and cardiac magnetic resonance (CMR), with the latter serving as the reference standard. METHODS AND RESULTS: In this prospective study, 51 patients underwent [13N]-ammonia-PET MPI and CMR using a hybrid PET/MR device. Left ventricular end-systolic volumes (LVESV), end-diastolic volumes (LVEDV), stroke volumes (LVSV), ejection fractions (LVEF), and segmental wall motion were analyzed for both methods and were compared using correlational and Bland-Altman (BA) analysis; segmental wall motion was compared using ANOVA. The agreement between [13N]-ammonia-PET and CMR for LVEF was good, with minimal bias (- .6%) and narrow BA limits of agreement (- 7.9% to 6.8%), but [13N]-ammonia-PET systematically underestimated LV volumes, with high bias in LVESV (- 11.2 ml), LVEDV (- 28.9 ml), and LVSV (- 17.5 ml). Mean segmental wall motion in [13N]-ammonia-PET differed significantly among the corresponding normokinetic (6.6 ± 2 mm), hypokinetic (5.1 ± 2 mm), and akinetic (3.3 ± 2 mm) segments in CMR (P < .01). CONCLUSION: LVEF and LV wall motion can be accurately assessed using [13N]-ammonia-PET MPI, although LV volumes are significantly underestimated compared to CMR.


Assuntos
Doença da Artéria Coronariana , Disfunção Ventricular Esquerda , Humanos , Função Ventricular Esquerda , Estudos Prospectivos , Amônia , Tomografia Computadorizada por Raios X , Tomografia por Emissão de Pósitrons/métodos , Volume Sistólico , Espectroscopia de Ressonância Magnética , Perfusão
7.
Eur Arch Otorhinolaryngol ; 280(4): 1973-1981, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36471046

RESUMO

OBJECTIVES: The aim of this study was to investigate the value of metabolic tumor imaging using hybrid PET for the preoperative detection of extranodal extension (ENE) in lymph node metastases of oropharyngeal squamous cell carcinoma (OPSCC). METHODS: We performed a retrospective analysis of a consecutive cohort of patients with OPSCC treated with primary surgery with or without adjuvant (chemo-) radiotherapy at the Kantonsspital Sankt-Gallen and the University Hospital Zurich, Switzerland, from 2010 until 2019. Hybrid PET was compared to conventional cross-sectional imaging with MRI and CT. Histopathological presence of ENE of neck dissection specimen served as gold standard. RESULTS: A total number of 234 patients were included in the study, 95 (40.6%) of which had pathological ENE (pENE). CT has a good specificity with 93.7%; meanwhile, MRI was the most sensitive diagnostic method (72.0%). The nodal metabolic tumor parameters (SUVmax, TLG, MTV) were significantly higher in patients with positive ENE (p < 0.001 for all three parameters) than in patients with negative ENE (p < 0.001, for all three parameters). CONCLUSIONS: CT achieved the best specificity, while MRI had the best sensitivity to detect ENE. Nodal metabolic tumor parameters differed significantly between ENE-positive/negative and p16-positive/negative patients. Hence, quantitative data obtained by metabolic imaging might predict presence of ENE and, therefore, could be helpful in customizing therapy management.


Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Primárias Desconhecidas , Neoplasias Orofaríngeas , Humanos , Extensão Extranodal , Estudos Retrospectivos , Neoplasias Primárias Desconhecidas/diagnóstico por imagem , Prognóstico , Neoplasias Orofaríngeas/diagnóstico por imagem , Neoplasias Orofaríngeas/terapia , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos
8.
Eur J Nucl Med Mol Imaging ; 49(11): 3917-3928, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35435496

RESUMO

PURPOSE: Recently, a significant association was shown between novel growth patterns on histopathology of prostate cancer (PCa) and prostate-specific membrane antigen (PSMA) uptake on [68Ga]PSMA-PET. It is the aim of this study to evaluate the association between these growth patterns and ADC (mm2/1000 s) values in comparison to [68Ga]PSMA uptake on PET/MRI. METHODS: We retrospectively evaluated patients who underwent [68Ga]PSMA PET/MRI for staging or biopsy guidance, followed by radical prostatectomy at our institution between 07/2016 and 01/2020. The dominant lesion per patient was selected based on histopathology and correlated to PET/MRI in a multidisciplinary meeting, and quantified using SUVmax for PSMA uptake and ADCmean for diffusion restriction. PCa growth pattern was classified as expansive (EXP) or infiltrative (INF) according to its properties of forming a tumoral mass or infiltrating diffusely between benign glands by two independent pathologists. Furthermore, the corresponding WHO2016 ISUP tumor grade was evaluated. The t test was used to compare means, Pearson's test for categorical correlation, Cohen's kappa test for interrater agreement, and ROC curve to determine the best cutoff. RESULTS: Sixty-two patients were included (mean PSA 11.7 ± 12.5). The interrater agreement between both pathologists was almost perfect with κ = 0.81. While 25 lesions had an EXP-growth with an ADCmean of 0.777 ± 0.109, 37 showed an INF-growth with a significantly higher ADCmean of 1.079 ± 0.262 (p < 0.001). We also observed a significant difference regarding PSMA SUVmax for the EXP-growth (19.2 ± 10.9) versus the INF-growth (9.4 ± 6.2, p < 0.001). Within the lesions encompassing the EXP- or the INF-growth, no significant correlation between the ISUP groups and ADCmean could be observed (p = 0.982 and p = 0.861, respectively). CONCLUSION: PCa with INF-growth showed significantly lower SUVmax and higher ADCmean values compared to PCa with EXP-growth. Within the growth groups, ADCmean values were independent from ISUP grading.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Radioisótopos de Gálio , Humanos , Masculino , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/patologia , Estudos Retrospectivos
9.
Eur J Nucl Med Mol Imaging ; 49(5): 1721-1730, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34725726

RESUMO

PURPOSE: Prostate-specific membrane antigen (PSMA)-targeted PET is increasingly used for staging prostate cancer (PCa) with high accuracy to detect significant PCa (sigPCa). [68 Ga]PSMA-11 PET/MRI-guided biopsy showed promising results but also persisting limitation of sampling error, due to impaired image fusion. We aimed to assess the possibility of intraoperative quantification of [18F]PSMA-1007 PET/CT uptake in core biopsies as an instant confirmation for accurate lesion sampling. METHODS: In this IRB-approved, prospective, proof-of-concept study, we included five consecutive patients with suspected PCa. All underwent [18F]PSMA-1007 PET/CT scans followed by immediate PET/CT-guided and saturation template biopsy (3.1 ± 0.3 h after PET). The activity in biopsy cores was measured as counts per minute (cpm) in a gamma spectrometer. Pearson's test was used to correlate counts with histopathology (WHO/ISUP), tumor length, and membranous PSMA expression on immunohistochemistry (IHC). RESULTS: In 43 of 113 needles, PCa was present. The mean cpm was overall significantly higher in needles with PCa (263 ± 396 cpm) compared to needles without PCa (73 ± 44 cpm, p < 0.001). In one patient with moderate PSMA uptake (SUVmax 8.7), 13 out of 24 needles had increased counts (100-200 cpm) but only signs of inflammation and PSMA expression in benign glands on IHC. Excluding this case, ROC analysis resulted in an AUC of 0.81, with an optimal cut-off to confirm PCa at 75 cpm (sens/spec of 65.1%/87%). In all 4 patients with PCa, the first or second PSMA PET-guided needle was positive for sigPCa with high counts (156-2079 cpm). CONCLUSIONS: [18F]PSMA-1007 uptake in PCa can be used to confirm accurate lesion sampling of the dominant tumor intraoperatively. This technique could improve confidence in imaging-based biopsy guidance and reduce the need for saturation biopsy. TRIAL REGISTRATION NUMBER: NCT03187990, 15/06/2017.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Radioisótopos de Gálio , Humanos , Biópsia Guiada por Imagem , Masculino , Agulhas , Niacinamida/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/cirurgia
10.
Eur Radiol ; 32(1): 508-516, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34156552

RESUMO

OBJECTIVES: To assess the frequency, intensity, and clinical impact of [18F]FDG-avidity of axillary lymph nodes after vaccination with COVID-19 vaccines BNT162b2 (Pfizer-BioNTech) and mRNA-1273 (Moderna) in patients referred for oncological FDG PET/CT. METHODS: One hundred forty patients referred for FDG PET/CT during February and March 2021 after first or second vaccination with Pfizer-BioNTech or Moderna were retrospectively included. FDG-avidity of ipsilateral axillary lymph nodes was measured and compared. Assuming no knowledge of prior vaccination, metastatic risk was analyzed by two readers and the clinical impact was evaluated. RESULTS: FDG PET/CT showed FDG-avid lymph nodes ipsilateral to the vaccine injection in 75/140 (54%) patients with a mean SUVmax of 5.1 (range 2.0 - 17.3). FDG-avid lymph nodes were more frequent in patients vaccinated with Moderna than Pfizer-BioNTech (36/50 [72%] vs. 39/90 [43%] cases, p < 0.001). Metastatic risk of unilateral FDG-avid axillary lymph nodes was rated unlikely in 52/140 (37%), potential in 15/140 (11%), and likely in 8/140 (6%) cases. Clinical management was affected in 17/140 (12%) cases. CONCLUSIONS: FDG-avid axillary lymph nodes are common after COVID-19 vaccination. The avidity of lymph nodes is more frequent in Moderna compared to that in Pfizer-BioNTech vaccines. To avoid relatively frequent clinical dilemmas, we recommend carefully taking the history for prior vaccination in patients undergoing FDG PET/CT and administering the vaccine contralateral to primary cancer. KEY POINTS: • PET/CT showed FDG-avid axillary lymph nodes ipsilateral to the vaccine injection site in 54% of 140 oncological patients after COVID-19 vaccination. • FDG-avid lymphadenopathy was observed significantly more frequently in Moderna compared to patients receiving Pfizer-BioNTech-vaccines. • Patients should be screened for prior COVID-19 vaccination before undergoing PET/CT to enable individually tailored recommendations for clinical management.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Vacina de mRNA-1273 contra 2019-nCoV , Vacina BNT162 , Fluordesoxiglucose F18 , Humanos , Linfonodos/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , SARS-CoV-2 , Vacinação
11.
J Nucl Cardiol ; 29(6): 3236-3247, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35175556

RESUMO

BACKGROUND: To assess whether low-dose CT for attenuation correction of myocardial perfusion single-photon emission computed tomography (SPECT) allows for identification of anemic patients and grading anemia severity. METHODS AND RESULTS: Patients who underwent a preoperative blood-test and low-dose CT scan, as a part of a cardiac SPECT exam, between 01 January 2015 and 31 December 2017 were enrolled in this retrospective study. Hemoglobin (Hb) levels and hematocrit were derived from clinical records. CT images were visually assessed (qualitative analysis) for the detection of inter-ventricular septum sign (IVSS) and aortic rim sign (ARS) and quantitative analysis were performed. The diagnostic accuracy for detecting anemia was compared using Hb values as the standard of reference. A total of 229 patients were included (110 with anemia; 57 mild; 46 moderate; 7 severe). The AUC of IVSS and ARS were 0.830 and 0.669, respectively (p<0.0001). The quantitative analysis outperformed ARS and IVSS; (AUC of 0.893, p=0.29). The optimal anemia cut-off using Youden index was 4.5 HU. CONCLUSION: Quantitative analysis derived from low-dose CT images, as a part of cardiac SPECT exams, have a diagnostic accuracy similar to that of hematocrit for the detection of anemia and may allow discriminating different anemia severities.


Assuntos
Anemia , Imagem de Perfusão do Miocárdio , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Anemia/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Perfusão
12.
J Digit Imaging ; 35(3): 581-593, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35212859

RESUMO

The aim of the study was to analyze the use of block sequential regularized expectation maximization (BSREM) with different ß-values for the detection of brain metastases in digital fluorine-18 labeled 2-deoxy-2-fluoro-D-glucose (18F-FDG) PET/CT in lung cancer patients. We retrospectively analyzed staging/restaging 18F-FDG PET/CT scans of 40 consecutive lung cancer patients with new brain metastases, confirmed by MRI. PET images were reconstructed using BSREM (ß-values of 100, 200, 300, 400, 500, 600, 700) and OSEM. Two independent blinded readers (R1 and R2) evaluated each reconstruction using a 4-point scale for general image quality, noise, and lesion detectability. SUVmax of metastases, brain background, target-to-background ratio (TBR), and contrast recovery (CR) ratio were recorded for each reconstruction. Among all reconstruction techniques, differences in qualitative parameters were analyzed using non-parametric Friedman test, while differences in quantitative parameters were compared using analysis of variances for repeated measures. Cohen's kappa (k) was used to measure inter-reader agreement. The overall detectability of brain metastases was highest for BSREM200 (R1: 2.83 ± 1.17; R2: 2.68 ± 1.32) and BSREM300 (R1: 2.78 ± 1.23; R2: 2.68 ± 1.36), followed by BSREM100, which had lower accuracy owing to noise. The highest median TBR was found for BSREM100 (R1: 2.19 ± 1.05; R2: 2.42 ± 1.08), followed by BSREM200 and BSREM300. Image quality ratings were significantly different among reconstructions (p < 0.001). The median quality score was higher for BSREM100-300, and both noise and metastases' SUVmax decreased with increasing ß-value. Inter-reader agreement was particularly high for the detectability of photopenic metastases and blurring (all k > 0.65). BSREM200 and BSREM300 yielded the best results for the detection of brain metastases, surpassing both BSREM400 and OSEM, typically used in clinical practice.


Assuntos
Neoplasias Encefálicas , Neoplasias Pulmonares , Neoplasias Encefálicas/diagnóstico por imagem , Radioisótopos de Flúor , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Estudos Retrospectivos
13.
Eur J Nucl Med Mol Imaging ; 48(13): 4483-4494, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34120201

RESUMO

PURPOSE: Improved logistics and availability led to a rapid increase in the use of [18F]-PSMA-1007 for prostate cancer PET imaging. Initial data suggests increased uptake in benign lesions compared to [68 Ga]-PSMA-11, and clinical observations found increased unspecific bone uptake (UBU). We therefore investigate the frequency and characteristics of UBU in [18F]-PSMA-1007 PET. METHODS: We retrospectively analyzed [18F]-PSMA-1007 PET scans from four centers for the presence of UBU, defined as a focal mild-to-moderate uptake (SUVmax < 10.0) not obviously related to a benign or malignant cause. If present, up to three leading UBUs were quantified (SUVmax), localized, and correlated to clinical parameters, such as age, PSA, injected dose, Gleason score, tumor size (T1-T4), and type of PET scanner (analog vs. digital). Additionally, clinical and imaging follow-up results and therapeutic impact were evaluated. RESULTS: UBUs were identified in 179 out of 348 patients (51.4%). The most frequent localizations were ribs (57.5%) and pelvis (24.8%). The frequency of UBUs was not associated with PSA, Gleason score, tumor size, age, or the injected [18F]-PSMA-1007 dose. UBUs were significantly more frequent in images obtained with digital PET/CT scans (n = 74, 82%) than analog PET/CT scans (n = 221, 40.3%) (p = .0001) but not in digital PET/MR (n = 53, 51%) (p = .1599). In 80 out of 179 patients (44.7%), the interpretation of UBUs was critical for therapeutic management and therefore considered clinically relevant. For 65 UBUs, follow-ups were available: three biopsies, three radiotherapies with PSA follow-up, and 59 cases with imaging. After follow-up, UBUs were still considered unclear in 28 of 65 patients (43%), benign in 28 (43%), and malignant in nine (14%) patients. CONCLUSION: UBUs occur in two-thirds of patients imaged with [18F]-PSMA-1007 PET/CT and are significantly more frequent on digital PET scanners than analog scanners. UBUs should be interpreted carefully to avoid over-staging.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Ácido Edético , Humanos , Masculino , Niacinamida/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
14.
Eur Radiol ; 31(10): 8011-8020, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33768288

RESUMO

OBJECTIVES: To compare block sequential regularized expectation maximization (BSREM) and ordered subset expectation maximization (OSEM) for the detection of in-transit metastasis (ITM) of malignant melanoma in digital [18F]FDG PET/CT. METHODS: We retrospectively analyzed a cohort of 100 [18F]FDG PET/CT scans of melanoma patients with ITM, performed between May 2017 and January 2020. PET images were reconstructed with both OSEM and BSREM algorithms. SUVmax, target-to-background ratio (TBR), and metabolic tumor volume (MTV) were recorded for each ITM. Differences in PET parameters were analyzed with the Wilcoxon signed-rank test. Differences in image quality for different reconstructions were tested using the Man-Whitney U test. RESULTS: BSREM reconstruction led to the detection of 287 ITM (39% more than OSEM). PET parameters of ITM were significantly different between BSREM and OSEM reconstructions (p < 0.001). SUVmax and TBR were higher (76.5% and 77.7%, respectively) and MTV lower (49.5%) on BSREM. ITM missed with OSEM had significantly lower SUVmax (mean 2.03 vs. 3.84) and TBR (mean 1.18 vs. 2.22) and higher MTV (mean 2.92 vs. 1.01) on OSEM compared to BSREM (all p < 0.001). CONCLUSIONS: BSREM detects significantly more ITM than OSEM, owing to higher SUVmax, higher TBR, and less blurring. BSREM is particularly helpful in small and less avid lesions, which are more often missed with OSEM. KEY POINTS: • In melanoma patients, [18F]FDG PET/CT helps to detect in-transit metastases (ITM), and their detection is improved by using BSREM instead of OSEM reconstruction. • BSREM is particularly useful in small lesions.


Assuntos
Melanoma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Algoritmos , Fluordesoxiglucose F18 , Humanos , Processamento de Imagem Assistida por Computador , Melanoma/diagnóstico por imagem , Compostos Radiofarmacêuticos , Estudos Retrospectivos
15.
Artif Organs ; 44(9): 939-946, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32302423

RESUMO

The use of left ventricular assist devices (LVADs) as a treatment method for heart failure patients has been steadily increasing; however, pathological studies showed presence of thrombi around the HeartWare ventricular assist device inflow cannula (IC) in more than 95% of patients after device explantation. Flow fields around the IC might trigger thrombus formation and require further investigation. In this study flow dynamics parameters were evaluated for different patient geometries using computational fluid dynamics (CFD) simulations. Left ventricular (LV) models of two LVAD patients were obtained from CT scans. The LV volumes of Patient 1 (P1) and Patient 2 (P2) were 264 and 114 cm3 with an IC angle of 20° and 9° from the mitral-IC tip axis at the coronal plane. The IC insertion site at the apex was central for P1, whereas it was lateral for P2. Transient CFD simulations were performed over 9 cardiac cycles. The wedge area was defined from the cannula tip to the wall of the LV apex. Mean velocity magnitude and blood stagnation region (volume with mean velocity <5 mm/s) as well as the wall shear stress (WSS) at the IC surface were calculated. Cardiac support resulted in a flow mainly crossing the ventricle from the mitral valve to the LVAD cannula for P2, while the main inflow jet deviated toward the septal wall in P1. Lower WSS at the IC surface and consequently larger stagnation volumes were observed for P2 (P1: 0.17, P2: 0.77 cm3 ). Flow fields around an LVAD cannula can be influenced by many parameters such as LV size, IC angle, and implantation site. Careful consideration of influencing parameters is essential to get reliable evaluations of the apical flow field and its connection to apical thrombus formation. Higher blood washout and lower stagnation were observed for a central implantation of the IC at the apex.


Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar/efeitos adversos , Modelos Cardiovasculares , Trombose/prevenção & controle , Idoso , Cânula/efeitos adversos , Simulação por Computador , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica/fisiologia , Humanos , Imageamento Tridimensional , Masculino , Estresse Mecânico , Trombose/etiologia , Tomografia Computadorizada por Raios X
16.
Clin Nucl Med ; 2024 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-39365097

RESUMO

ABSTRACT: A 51-year-old man with severe multifactorial neurocognitive disorders subsequent to delirium, benzodiazepine withdrawal, and preexisting psychiatric illness was referred for 18F-FDG PET/CT brain imaging in order to rule out an underlying neurodegenerative cause of the symptoms, particularly frontotemporal lobar degeneration. Imaging was impaired by severe motion artifacts, leading to a false-positive result. However, utilizing retrospective data-driven motion correction facilitated a change in diagnosis, ruling out the presence of neurodegenerative disease. The implementation of motion correction of the 18F-FDG PET dataset proved crucial for the patient, as the exclusion of frontotemporal lobar degeneration formed the basis for continuing psychiatric and psychotherapeutic treatment.

17.
Med Mycol Case Rep ; 44: 100648, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38654745

RESUMO

We describe a case of rhino-orbital-cerebral mucormycosis (ROCM) in a diabetic patient. She presented with cavernous sinus syndrome and ischemia of the optic nerve. Initially unremarkable findings in the nasal cavity and paranasal sinus delayed early diagnosis. Within two weeks, a follow-up MRI showing progressive orbital inflammation, thrombosis of the cavernous sinus and erosive destruction of the left middle nasal concha together with necrotic black tissue in the left nasal cavity and destruction of the maxillary sinus demonstrated in a consecutively performed ethmoidectomy, finally gave way to diagnosis. Definite diagnosis was established by histopathology and culture. Treatment consisted of a combination of liposomal Amphotericin B, partial surgical resection and improved diabetes control. Despite insufficient surgical treatment, the progression of the disease was remarkably slow - a typical hallmark of chronic ROCM. With this case report we aim to underline the difficulties in establishing a prompt diagnosis of ROCM and to remind readers of its chronic form. 2012 Elsevier Ltd. All rights reserved.

18.
Clin Exp Med ; 24(1): 234, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39352553

RESUMO

Metastatic uveal melanoma (mUM) is associated with poor prognosis. Ipilimumab/nivolumab has shown antitumor efficacy in phase II studies. Tebentafusp resulted in longer overall survival (OS) compared to investigator`s choice in a phase III study. We sought to describe the radiological response patterns of mUM patients treated with immunotherapy. Patients with mUM treated with ipilimumab/nivolumab and tebentafusp between July 2018 and December 2022, with available radiological assessment per RECISTv1.1 and/or imPERCIST5, were retrospectively identified and included. Progression-free survival (PFS) and OS rates, liver-specific response and pathological assessment in available liver biopsies were evaluated. In the ipilimumab/nivolumab group, median PFS (mPFS) was 2.9 months (95% CI 2.2-28.6) and mOS 28.9 months (95% CI 12.7-NR). Complete (CMR) and partial (PMR) metabolic response per imPERCIST5, and partial response (PR) per RECISTv1.1 were associated with longer PFS and OS by trend, compared to morphologically and metabolically stable or progressive disease. In the tebentafusp group, mPFS was 2.7 months (95% CI 2.2-3) and mOS 18.6 months (95% CI 11.5-NR). PMR and PR were associated with longer PFS by trend. In both treatments, the overall treatment response was associated with the radiological response at the liver site. In available liver tumor biopsies, differences in pathological and radiological responses were noted. ImPERCIST5 and RECIST v1.1 are valuable tools in the radiological response assessment, but both methods display limitations. Accurate biomarkers to stratify patients at risk for disease progression and future translational studies to investigate mechanisms of response and resistance are required.


Assuntos
Imunoterapia , Ipilimumab , Melanoma , Nivolumabe , Neoplasias Uveais , Humanos , Neoplasias Uveais/patologia , Neoplasias Uveais/tratamento farmacológico , Neoplasias Uveais/mortalidade , Neoplasias Uveais/terapia , Neoplasias Uveais/imunologia , Melanoma/tratamento farmacológico , Melanoma/patologia , Melanoma/terapia , Melanoma/imunologia , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Nivolumabe/uso terapêutico , Ipilimumab/uso terapêutico , Imunoterapia/métodos , Adulto , Resultado do Tratamento , Resistencia a Medicamentos Antineoplásicos , Idoso de 80 Anos ou mais , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Intervalo Livre de Progressão
19.
Clin Nucl Med ; 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39325145

RESUMO

PURPOSE: Hypophysitis occurs in up to 10% of patients treated with immune-checkpoint inhibitors (ICIs). MRI shows no abnormalities of the pituitary gland in one third of patients. A delayed diagnosis increases the risk for life-threatening adrenal crisis, underscoring the need for early detection. This study evaluates the diagnostic accuracy FDG PET/CT in detecting ICI-induced hypophysitis in a cohort of melanoma patients. MATERIALS AND METHODS: Patients with metastatic melanoma and ICI-induced hypophysitis, who underwent FDG PET/CT 90 days before to 10 days after diagnosis, were compared with an age- and sex-matched control group of patients undergoing ICI treatment without signs of hypophysitis. The ratio of SUVmax of the pituitary gland to the SUVmean of the blood pool (target-to-background ratio [TBR]) was calculated. Diagnostic accuracy of the TBR was assessed using area under the receiver operating characteristics curve analysis. RESULTS: A total of 28 patients was included. The majority of patients with hypophysitis received ipilimumab/nivolumab (64.3%, 9/14). Visual assessment of the TBR distribution demonstrated a positive correlation with decreasing time to diagnosis. To evaluate diagnostic performance, only patients with FDG PET/CT 50 days before to 8 days after diagnosis (11/14) were included. TBR was significantly higher in these compared with the control group (median [interquartile range], 2.78 [2.41] vs 1.59 [0.70], respectively; P = 0.034). A sensitivity of 72.7% and a specificity of 90.9% were achieved at a TBR threshold of 2.41 (area under the receiver operating characteristics curve = 0.769). CONCLUSIONS: Our findings suggest that, in patients undergoing ICI treatment for metastatic melanoma, a pituitary TBR of approximately 2.4 may indicate impending ICI-induced hypophysitis.

20.
EJNMMI Res ; 14(1): 36, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578516

RESUMO

BACKGROUND: Liver uptake in [68Ga]Ga-PSMA-11 PET is used as an internal reference in addition to clinical parameters to select patients for [177Lu]Lu-PSMA-617 radioligand therapy (RLT). Due to increased demand, [68Ga]Ga-PSMA-11 was replaced by [18F]F-PSMA-1007, a more lipophilic tracer with different biodistribution and splenic uptake was suggested as a new internal reference. We compared the intra-patient tracer distribution between [68Ga]Ga-PSMA-11 and [18F]F-PSMA-1007. METHODS: Fifty patients who underwent PET examinations in two centers with both [18F]F-PSMA-1007 and [68Ga]Ga-PSMA-11 within one year were included. Mean standardized uptake values (SUVmean) were obtained for liver, spleen, salivary glands, blood pool, and bone. Primary tumor, local recurrence, lymph node, bone or visceral metastasis were also assessed for intra- and inter-individual comparison. RESULTS: Liver SUVmean was significantly higher with [18F]F-PSMA-1007 (11.7 ± 3.9) compared to [68Ga]Ga-PSMA-11 (5.4 ± 1.7, p < .05) as well as splenic SUVmean (11.2 ± 3.5 vs.8.1 ± 3.5, p < .05). The blood pool was comparable between the two scans. Malignant lesions did not show higher SUVmean on [18F]F-PSMA-1007. Intra-individual comparison of liver uptake between the two scans showed a linear association for liver uptake with SUVmean [68Ga]Ga-PSMA-11 = 0.33 x SUVmean [18F]F-PSMA-1007 + 1.52 (r = .78, p < .001). CONCLUSION: Comparing biodistribution of [68Ga]Ga and [18F]F tracers, liver uptake on [68Ga]Ga-PSMA-11 PET is the most robust internal reference value. Liver uptake of [18F]F-PSMA-1007 was significantly higher, but so was the splenic uptake. The strong intra-individual association of hepatic accumulation between the two scans may allow using of a conversion factor for [18F]F-PSMA-1007 as a basis for RLT selection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA