Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Anat ; 243(3): 545-554, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36924312

RESUMO

There are studies that show the better balance after dry needling in lumbar pain. However, the postural control effects after foot dry needling are unknown. Our objective was to check if dry needling reduces postural control. Eighteen subjects with flexor digitorum brevis (FDB) muscle Myofascial trigger point were evaluated pre- and post-deep dry needling. We measured stabilometric variables in a pre-post study. We have found significant differences in three stabilometric variables: surface with eyes closed (29.36-53.21 mm2 ) (p = 0.000), medium speed of the laterolateral displacement with eyes closed (1.42-1.64 mm/s) (p = 0.004), and medium speed of the anteroposterior displacement with eyes closed (1.30-1.53 mm/s) (p = 0.025). Dry needling therapy application in FDB muscle reduces standing postural control with eyes closed.


Assuntos
Agulhamento Seco , Síndromes da Dor Miofascial , Equilíbrio Postural , Pontos-Gatilho , Agulhamento Seco/efeitos adversos , Músculo Esquelético , Posição Ortostática , Humanos , Síndromes da Dor Miofascial/fisiopatologia , Síndromes da Dor Miofascial/terapia , Masculino , Feminino ,
2.
BMC Nurs ; 22(1): 408, 2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-37904211

RESUMO

BACKGROUND: Transnational migratory movements make Spain a country with a very diverse population, including women and girls from countries where Female Genital Mutilation (FGM) is practiced. Given this reality, we set out to carry out a qualitative study to identify the knowledge, attitudes and skills of health professionals regarding FGM. METHOD: Qualitative study with a content analysis approach. Forty-seven health professionals with the profiles of Nursing, Family Medicine, Pediatrics, Midwifery and Gynecology and Obstetrics were purposively selected. Data were collected through semi-structured in-depth interviews and focus groups. The qualitative content analysis approach was used for data analysis. The study was conducted in the years 2019 and 2022. RESULTS: Although most professionals are aware of the current legislation on FGM in Spain, only a few of them are aware of the existence of the FGM prevention protocol in Castilla-La Mancha. This lack of knowledge together with the perception that FGM belongs to the private sphere of women, contributes to the loss of opportunities to identify and prevent FGM. CONCLUSION: Health professionals' training, especially midwives and pediatricians, is essential to the identification and action against Female Genital Mutilation.

3.
Int J Clin Pract ; 2022: 1746782, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35685601

RESUMO

Background: Intensive care units (ICUs) may produce stress on the relatives of patients that have long-term physiological and psychological implications. Objectives: This study aimed to evaluate the effects of the relatives´ visit prior to hospital admission(s) on the patient's scheduled cardiac surgery regarding depression, anxiety, and satisfaction of the patient's family in an ICU. Methods: A randomized clinical trial [NCT03605420] was carried out according to the CONSORT criteria. Thirty-eight relatives of ICU patients were recruited at an ICU and randomized into study groups. Experimental group participants (n = 19) consisted of relatives who received 1 ICU visit prior to the patient's admission. Control group participants (n = 19) consisted of patients' relatives who received standard care alone. A self-report test battery, including the Impact of Event Scale-Revised (IES-R) and the Hospital Anxiety and Depression Scale (HADS), was completed by the patient's relative prior to the patient's ICU admission and again three and 90 days after ICU discharge. Furthermore, the Family Satisfaction with Care in the Intensive Care Unit (FS-ICU) and Critical Care Family Needs Inventory (CCFNI) were administered to help determine the respondents' satisfaction three days after the patient's ICU discharge. Results: Statistically significant differences in FS-ICU results were found between control and experimental groups; no statistically significant differences were found in IES-R, HADS, and CCFNI results. Thus, members in the control group were more satisfied with the time elapsed to raise their concerns (p=0.005), emotional support provided (p=0.020), quality of care (p=0.035), opportunities to express concerns and ask questions (p=0.005), and general satisfaction with the ICU's decision-making (p=0.003). Conclusions: Relatives' satisfaction during patients' ICU admission may be impaired after their prior visit to the hospital admission. Relative's anxiety and depression scores did not seem to be significantly affected. Relatives´ visit prior to elective cardiac surgery hospital admission impaired their satisfaction in an ICU and may not be advisable for healthcare practice.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Depressão , Ansiedade/psicologia , Depressão/psicologia , Família/psicologia , Hospitais , Humanos , Unidades de Terapia Intensiva , Satisfação Pessoal
4.
J Tissue Viability ; 30(2): 271-275, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33608187

RESUMO

PURPOSE: The objective of this study is examine Quality of Life in subjects with chronic kidney disease utilizing Foot Health Status Questionnaire (FHSQ). MATERIAL AND METHODS: 101 subjects with chronic kidney disease (CKD) was studied in specialized clinics, in Extremadura (Spain). An observational descriptive study. The FHSQ was utilized to assess specific foot health (first section) and overall health (second division). The differences between clumps they were assessed using a t-test to independent samples. RESULTS: 59.40% (n = 60) were men and 40.59% (n = 41) women. The mean age was 68.77 ± 14.07. In first division of the FHSQ, a less score was registered in footwear domain (39.25) and in general foot health domain (46.37). In second division, less scores were resulted in general health domain (72) and vigour domain (60.43). CKD women got less scores in every domain. Women with CKD obtained significantly less scores in dimensions of foot pain, foot function, footwear, general foot health, general health and physical activity and there was no difference contrasted with men in the dimensions of social capacity and vigour. CONCLUSIONS: The studied CKD population has problems their feet. Quality of life of CKD subjects is negatively impacted by health of their feet, difficulties with footwear, their overall health, and lack of vitality. Women with CKD show lower values of quality of life contrasted to male patients, associated with inability to perform physical activity, lack of energy and tiredness.


Assuntos
Pé/fisiopatologia , Insuficiência Renal Crônica/complicações , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida/psicologia , Insuficiência Renal Crônica/fisiopatologia , Espanha , Inquéritos e Questionários
5.
Pain Med ; 21(2): e172-e181, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31502640

RESUMO

OBJECTIVE: To determine the immediate efficacy of a single session of deep dry needling (DDN) vs ischemic compression (ICT) in a latent myofascial trigger point (MTrP) of the shortened triceps surae from triathletes for ankle dorsiflexion and redistribution of plantar pressures and stability. DESIGN: A randomized simple blind clinical trial (NCT03273985). SETTING: An outpatient clinic. SUBJECTS: Thirty-four triathletes with a latent MTrP in the shortened gastrocnemius. METHODS: Triathletes were randomized to receive a single session of DDN (N = 17) or ICT (N = 17) in a latent MTrP of the shortened triceps surae. The primary outcome was ankle dorsiflexion range of motion (ROM) by a universal goniometer. Secondary objectives were distribution of dynamic and static plantar pressures by T-Plate platform pressure, with measurements both before and after five, 10, 15, 20, and 25 minutes of treatment. RESULTS: There were no statistically significant differences (P > 0.05) for ankle dorsiflexion ROM or dynamic and static plantar pressures between the experimental group treated with DDN and the control group treated with ICT before and after treatment. CONCLUSIONS: DDN vs ICT carried out in latent MTrPs of the shortened gastrocnemius of triathletes did not present differences in terms of dorsiflexion ROM of the tibiofibular-talar joint or in static and dynamic plantar pressure changes before and immediately after treatment.


Assuntos
Agulhamento Seco/métodos , Músculo Esquelético , Síndromes da Dor Miofascial/terapia , Modalidades de Fisioterapia , Adulto , Articulação do Tornozelo , Atletas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Pontos-Gatilho
6.
J Med Internet Res ; 22(7): e19781, 2020 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-32706672

RESUMO

BACKGROUND: Home blood pressure monitoring has many benefits, even more so, in populations prone to high blood pressure, such as persons with diabetes. OBJECTIVE: The purpose of this research was to validate the QardioArm mobile device in a sample of individuals with noninsulin-dependent type 2 diabetes in accordance with the guidelines of the second International Protocol of the European Society of Hypertension. METHODS: The sample consisted of 33 patients with type 2 diabetes. To evaluate the validity of QardioArm by comparing its data with that obtained with a digital sphygmomanometer (Omron M3 Intellisense), two nurses collected diastolic blood pressure, systolic blood pressure, and heart rate with both devices. RESULTS: The analysis indicated that the test device QardioArm met all the validation requirements using a sample population with type 2 diabetes. CONCLUSIONS: This paper reports the first validation of QardioArm in a population of individuals with noninsulin-dependent type 2 diabetes. QardioArm for home monitoring of blood pressure and heart rate met the requirements of the second International Protocol of the European Society of Hypertension.


Assuntos
Determinação da Pressão Arterial/métodos , Diabetes Mellitus Tipo 2/complicações , Adulto , Feminino , Humanos , Masculino
7.
Sensors (Basel) ; 20(6)2020 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-32168780

RESUMO

: Nowadays, the use of insoles in sport practice have been recognized to decrease the foot and lower limb injury patterns. The aim of this study was to analyse the effect of four types of hardness insoles (HI) in the activity patterns of the hip and thigh muscles (HTM) in motoriders during motorcycling sport. The study was a crossover trial. Subjects were elite motoriders. The mean age was 33 ± 5.14 years. Electromyography (EMG) of hip and thigh muscles (HTM) data was registered via surface while subjects were riding on an elite motorcycle simulator. Subjects had to complete different tests with randomly hardest insoles (HI): 1: only polypropylene (58° D Shore); 2: Polypropylene (58° D Shore) with selective aluminium in hallux and metatarsal heads (60 HB Brinell hardness); 3: Ethylene vinyl acetate (EVA) (52° A Shore); and finally, 4: Ordinary EVA (25° A Shore) as the control. EMG patterns of the HTM, riding on an elite motorcycle simulator, showed the lowest peak amplitude with the insoles with polypropylene and selective aluminium. Using the hardest insoles in our study (selective aluminium) the EMG amplitude peaks decreased in all HTM.


Assuntos
Eletromiografia/métodos , Órtoses do Pé , Dureza/fisiologia , Motocicletas , Músculo Esquelético/fisiologia , Adulto , Estudos Cross-Over , Quadril/fisiologia , Humanos , Masculino , Polipropilenos , Esportes , Coxa da Perna/fisiologia
8.
J Med Internet Res ; 21(12): e14686, 2019 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-31789600

RESUMO

BACKGROUND: Hypertension is considered as a main risk factor for chronic kidney disease development and progression. Thus, the control and evaluation of this disease with new software and devices are especially important in patients who suffer from chronic kidney disease. OBJECTIVE: This study aimed to validate the QardioArm mobile device, which is used for blood pressure (BP) self-measurement in patients who suffer from chronic kidney disease, by following the European Society of Hypertension International Protocol 2 (ESH-IP2) guidelines. METHODS: A validation study was carried out by following the ESH-IP2 guidelines. A sample of 33 patients with chronic kidney disease self-measured their BP by using the QardioArm and Omron M3 Intellisense devices. Heart rate (HR), diastolic BP, and systolic BP were measured. RESULTS: The QardioArm fulfilled the ESH-IP2 validation criteria in patients who suffered from chronic kidney disease. CONCLUSIONS: Thus, this study is considered as the first validation using a wireless upper arm oscillometric device connected to an app to measure BP and HR meeting the ESH-IP2 requirements in patients who suffer from chronic kidney disease. New validation studies following the ESH-IP2 guidelines should be carried out using different BP devices in patients with specific diseases.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial/normas , Hipertensão/diagnóstico , Insuficiência Renal Crônica/complicações , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco
9.
Life (Basel) ; 14(6)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38929738

RESUMO

BACKGROUND: Nowadays, pregnant women require more individualized attention in their assistance process during pregnancy. One of the aspects that requires the most focus is the suitability of carrying out physical activity. The objective of this meta-review is to find out the effects of physical activity during pregnancy on the incidence of GDM compared to women who do not perform physical activity. METHODS: A search was conducted in Cochrane, CSIC, Ebscohost, Proquest, Pubmed, Scielo, and Scopus. The search focused on systematic reviews and meta-analyses published in the last five years. The AMSTAR-2 scale was used as a quality assessment tool for the final sample. RESULTS: A total of 18 systematic reviews and meta-analyses were included. Sixteen of them found out that physical activity during pregnancy has preventive effects for GDM compared with women who lacked physical activity. Among the studies, we found a reduction in the risk of GDM of between 24% and 38% and odds ratios ranging between 0.39 and 0.83 calculated for a 95% CI. Only two studies did not find statistically significant effects. Other variables such as type and duration of physical activity, overweight and obesity, gestational age, etc., were also considered. CONCLUSIONS: Physical activity prevents the incidence of GDM. The main characteristics that enhance this preventive effect are starting at the initial stages of pregnancy and maintaining during the whole pregnancy as well as combining strength and aerobic exercise at a low to moderate intensity.

10.
PeerJ ; 11: e15011, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36919164

RESUMO

Background: Infrared thermography devices have been commonly applied to measure superficial temperature in structural composites and walls. These tools were cheaper than other thermographic devices used to measure superficial human muscle tissue temperature. In addition, infrared thermography has been previously used to assess skin temperature related to muscle tissue conditions in the triceps surae of athletes. Nevertheless, the reliability and repeatability of an infrared thermography device designed for materials, such as the Manual Infrared Camera PCE-TC 30, have yet to be determined to measure skin temperature of the triceps surae muscle tissue of athletes. Objective: The purpose was to determine the procedure's intra- and inter-session reliability and repeatability to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device in the triceps surae muscle tissue of athletes, which was initially designed to measure the superficial temperature of materials. Methods: A total of 34 triceps surae muscles were bilaterally assessed from 17 healthy athletes using the Manual Infrared Camera PCE-TC 30 thermography device to determine intra- (at the same day separated by 1 h) and inter-session (at alternate days separated by 48 h) reliability and repeatability of the skin temperature of the soleus, medial and lateral gastrocnemius muscles. The triceps surae complex weas measured by a region of interest of 1 cm2 through five infrared thermography images for each muscle. Statistical analyses comprised intraclass correlation coefficient (ICC), standard error of measurement (SEM), minimum detectable change (MCD), systematic error of measurement, correlation (r), and Bland-Altman plots completed with linear regression models (R 2). Results: Intra- and inter-session measurements of the proposed infrared thermography procedure showed excellent reliability (ICC(1,2) = 0.968-0.977), measurement errors (SEM = 0.186-0.232 °C; MDC = 0.515-0.643 °C), correlations (r = 0.885-0.953), and did not present significant systematic error of measurements (P > 0.05). Adequate agreement between each pair of measurement moments was presented by the Bland-Altman plots according to the limits of agreement and non-significant linear regression models (R 2 = 0.000-0.019; P > 0.05). Conclusions: The proposed procedure to determine skin temperature within the Manual Infrared Camera PCE-TC 30 thermography device presented excellent intra- and inter-session reliability and repeatability in athletes' triceps surae muscle tissue. Future studies should consider the SEM and MDC of this procedure to measure the skin temperature of soleus, medial, and lateral gastrocnemius muscles to promote triceps surae muscle prevention and recovery in athletes.


Assuntos
Temperatura Cutânea , Termografia , Humanos , Termografia/métodos , Reprodutibilidade dos Testes , Músculo Esquelético/fisiologia , Perna (Membro)
11.
PeerJ ; 11: e15298, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37151296

RESUMO

Background: One of the measures for controlling the coronavirus disease 2019 (COVID-19) pandemic was the mass closure of gyms. This measure leads us to determine the differences between indoor and outdoor air quality. That is why the objective of this study was to analyse the indoor air quality of a sports centre catering to small groups and rehabilitation. Methods: The study was conducted in a single training centre, where 26 measurements were taken in two spaces (indoors and outdoors). The air quality index, temperature, relative humidity, total volatile compounds, carbon monoxide, ozone, formaldehyde, carbon dioxide, and particulate matter were measured indoors and outdoors using the same protocol and equipment. These measurements were taken twice, once in the morning and once in the afternoon, with all measurements made at the same time, 10 am and 6 pm, respectively. Additionally, four determinations of each variable were collected during each shift, and the number of people who had trained in the room and the number of trainers were counted. Results: In the different variables analysed, the results show that CO2 and RH levels are higher indoors than outdoors in both measurement shifts. Temperatures are higher outside than inside and, in the evening, than in the morning. TVOC, AQI and PM show less variation, although they are higher outdoors in the morning. CO is highest indoors. HCHO levels are almost negligible and do not vary significantly, except for a slight increase in the afternoon outside. Ozone levels are not significant. All the variables showed practically perfect reliability in all the measurements, except for ozone measured outside in the morning. On the other hand, the variables exhibit variations between indoors and outdoors during the morning and afternoon, except for the three types of PM. Also, the data show that all the main variables measured inside the sports training centre are similar between morning and afternoon. However, outside, temperature, relative humidity and HCHO levels show significant differences between morning and afternoon while no differences are observed for the other variables. Conclusion: The indoor air quality of the training centre assessed was good and met current regulations; some of its components even exhibited better levels than fresh air. This article is the first to measure indoor air quality in a sports training centre catering to rehabilitation and small groups.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , COVID-19 , Ozônio , Humanos , Poluição do Ar em Ambientes Fechados/análise , Poluentes Atmosféricos/efeitos adversos , Reprodutibilidade dos Testes , COVID-19/epidemiologia , Ozônio/análise
12.
J Pers Med ; 13(1)2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36675670

RESUMO

Preventing, diagnosing, and controlling high blood pressure is a global health priority. The self-measurement of blood pressure is therefore fundamental and should be done with devices validated by recognized protocols, although most are not. The most widely used and current protocols are the 2010 European Society of Hypertension (ESH) revision and the 2018 Association for the Advancement of Medical Instrumentation (AAMI)/ ESH/ the International Organization for Standardization (ISO) universal standard, respectively. The aim of this study was to find out which blood pressure measuring devices have been adequately validated by the above protocols. A narrative review of blood pressure device validations was conducted by searching the PubMed database. From 52 records identified, 37 studies were included. Most validations follow the 2010 revision and only six follow the 2018 protocol, which is more demanding. Almost all validated sphygmomanometers are automated oscillometric sphygmomanometers in the general population. Wrist devices and devices combining new technologies are also validated, as well as in specific populations, such as the obese, pregnant women, or children. There is sufficient evidence to confirm that the universal AAMI/ ESH/ISO standard is considered the protocol of the century. However, it is necessary to increase the number of validations following it and, above all, validations of the new technologies that are invading the current market.

13.
Front Psychol ; 13: 841917, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35983198

RESUMO

Child maltreatment is conceived as a public health problem. Therefore, it is appropriate to analyse the explanatory models that deal with this behaviour, reflecting these postulates within the panorama of health education, which makes health professionals responsible for taking action. In order to do this, the theoretical context and the awareness of nursing students in relation to these theories must be analysed. In turn, the use of information and communication technologies in this field should be valued, due to their capacity to manage and systematise information, becoming a relevant tool when training future nursing professionals. Without forgetting that health informatics is a spectrum of multidisciplinary fields that includes the study of the design, development and application of computational techniques to improve healthcare. A review of the scientific literature was carried out, for which primary and secondary sources were consulted, tracing a search for data thanks to the keywords: 'nursing'; 'abuse'; 'children'; 'education' and 'theory'. During the second half of the 20th century, several health paradigms have been developed, which present different pathways to health education. There have also been three generations of theoretical models that attempt to analyse the public health problem of child maltreatment. This reflects the need for a transdisciplinary approach to child abuse, where there is no one explanatory model that is more appropriate than another, but where the choice of the health education paradigm and, within this, the most recommendable theory will depend on each situation.

14.
Artigo em Inglês | MEDLINE | ID: mdl-33809948

RESUMO

BACKGROUND: The analysis of the center of pressure (COP) is a method used to assess the foot function, but its reliability and repeatability have not been evaluated. COP can be altered by diverse conditions, like an excessive foot pronation. Low-Dye taping is commonly used for the treatment of symptoms related to an excessive pronation. To date, no study has evaluated the effects of the Low-Dye taping on COP and the duration of its effects. Thus, the main purpose of this manuscript was to assess the reliability and repeatability of the percentage of center of pressure locus area (%CLA) in feet with an excessive pronation, and secondarily, to assess that the Low-Dye taping modifies the %CLA during the immediate 48 h. METHODS: An observational study of the reliability and repeatability of the %CLA variable with the Low-Dye taping in feet with excessive pronation was carried out. We used the EPS-Platform to evaluate the results of the variable in 6 conditions in a first session to evaluate the reliability of the results. We compared the results of the first session with the results in a second session to evaluate the repeatability of the results. We also carried out an ANOVA test to evaluate the changes that the taping produced in the variable between without taping with the rest of the 6 conditions. RESULTS: For the %CLA, we observed a reliability greater than 0.80, measured by the interclass ratio index, both in the first session before taping, and in the second session before taping, thus being a repeatability variable. In the following times, with taping, at 10 min with tape, at 20 min with tape, at 24 h with tape and at 48 h with tape; an interclass ratio coefficient (ICC) higher than 0.80 was again obtained, thus being a reliable variable in all measurements made. The Low-Dye taping did not change %CLA from the time the tape was put in until 48 h (p-value = 1.000). CONCLUSIONS: The %CLA variable, in feet with excessive pronation, proved to be a reliable variable in all the measurements obtained before putting on the tape and during the following 48 h with the tape, and a repeatable variable. The Low-Dye taping did not change the %CLA from the time the tape was put in until 48 h.


Assuntos
Podiatria , , Pronação , Reprodutibilidade dos Testes
15.
Sao Paulo Med J ; 139(4): 319-324, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34037202

RESUMO

BACKGROUND: Frailty is a condition that can increase the risk of falls. In addition, foot disorders can negatively influence elderly people, thus affecting their condition of frailty. OBJECTIVE: To determine whether foot pain can influence a greater degree of frailty. DESIGN AND SETTING: Cross-sectional descriptive study conducted at the University of Valencia, Valencia, Spain. METHODS: A sample older than 60 years (n = 52), including 26 healthy subjects and 26 foot pain patients, was recruited. Frailty disability was measured using the 5-Frailty scale and the Edmonton Frailty scale (EFS). RESULTS: There were statistically significant differences in the total EFS score and in most of its subscales, according to the Mann-Whitney U test (P < 0.05). In addition, foot pain patients presented worse scores (higher 5-Frailty scores) than did healthy patients, regarding matched-paired subjects (lower EFS scores). With regard to the rest of the measurements, there were no statistically significant differences (P > 0.05). The highest scores (P < 0.001) were for fatigue on the 5-Frailty scale and the EFS, and for the subscale of independence function in EFS. CONCLUSIONS: These elderly patients presented impairment relating to ambulation and total 5-Frailty score, which seemed to be linked to the presence of frailty syndrome and foot disorders.


Assuntos
Fragilidade , Idoso , Estudos de Casos e Controles , Estudos Transversais , Idoso Fragilizado , Fragilidade/complicações , Fragilidade/epidemiologia , Humanos , Dor/epidemiologia , Dor/etiologia
16.
Artigo em Inglês | MEDLINE | ID: mdl-33467061

RESUMO

Tailor's bunion (TB) disease should be considered one of the foot injuries that causes disability in feet as well as general health. This case-control descriptive study investigated and contrasted the effects of different TB types in a sociodemographic population using the Foot Health Status Questionnaire (FHSQ). A sample of 100 subjects with a mean age of 51.70 ± 17.78 years was recruited and requested to reply to a foot health survey. Results were self-reported. Subjects were scored. Participants with TB type III (TB3) registered lower scores for foot pain, foot function, footwear, and foot health. Physical activity and social capacity had higher scores, and vigor and general health were lower. A Kruskal-Wallis test was used for systematic differences between the FHSQ and different TB types. In all analyses, statistical significance was considered a p-value <0.05 with a 95% confidence interval. Statistically significant differences were found between all domains of the FHSQ and TB, except for the social capacity domain and vigor. The FHSQ is an important measurement tool in TB subjects, showing that factors such as sex, age, and footwear used throughout an individual's life are significantly associated with the development of TB3 and its influence on foot pain and foot health.


Assuntos
Joanete do Alfaiate/psicologia , Dor/epidemiologia , Qualidade de Vida , Adulto , Idoso , Idoso de 80 Anos ou mais , Joanete do Alfaiate/diagnóstico , Estudos de Casos e Controles , Exercício Físico , Feminino , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Dor/psicologia , Inquéritos e Questionários
17.
Quant Imaging Med Surg ; 11(1): 84-94, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33392013

RESUMO

BACKGROUND: The lateral ankle ligament complex is the most frequently injured ligament secondary to strong ankle inversion movement during lateral ankle sprains (LAS). Among these injuries, anterior talofibular ligament (ATFL) injury is the most frequent condition (present in 66-85% of such injuries). The purpose of this research was to use magnetic resonance imaging (MRI) to determine the association between ankle tendon, ligament, and joint conditions and ATFL injuries. METHODS: A case-control MRI study was carried out to compare the presence of ankle muscle, tendon, ligament, and joint conditions in patients with injured ATFLs (case group; n=25) and non-injured ATFLs (control group; n=25). RESULTS: Achilles tendinopathy was present in 1/25 (4%) patients with injured ATFLs and 7/25 (28%) non-injured ATFL subjects (P=0.048). Injured calcaneofibular ligaments (CFLs) were present in 19/25 (76%) patients with injured ATFLs and 1/25 (4%) non-injured ATFL subjects (P<0.001). Finally, injured tibiotalar joints were present in 16/25 (64%) patients with injured ATFLs and 5/25 (20%) non-injured ATFL subjects (P=0.002). Other musculoskeletal structure injuries occurred at similar rates between patients with injured ATFLs and those with non-injured ATLFs (P≥0.05). CONCLUSIONS: Patients with ATFL injuries showed a greater presence of CFL and tibiotalar joint injuries than subjects with non-injured ATFLs.

18.
Healthcare (Basel) ; 8(4)2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33322505

RESUMO

OBJECTIVE: M-mode ultrasound imaging (US) reflects the motion of connective tissue within muscles. The objectives of this study were to evaluate inter-rater and intra-rater reliability of soleus muscle measurements between examiners with different levels of US experience in asymptomatic subjects and to investigate the level of soleus muscle isometric activity in two positions (knee extended and knee flexed at 30°). METHODS: Thirty volunteers without a history of ankle pain were evaluated with US examinations of the soleus muscle. Each muscle was scanned independently by two evaluators. Muscle at rest thickness, maximal isometric contraction thickness, time and velocity measures were detailed and blinded to the other examiner. RESULTS: Intra- and inter-rater reliability at rest, in maximal isometric contraction thickness, contraction time and contraction velocity measures for both positions (extended and flexed knee) were reported from good to excellent for all outcome measurements. The position with the knee extended reported a statistically significant increase in thickness after motion showing 1.33 ± 0.27 mm for measurements at rest thickness with knee extended versus 1.50 ± 0.29 mm for measurements at end thickness with the knee in flexed position (p = 0.001), as well as 1.31 ± 0.23 mm for rest thickness with the knee in flexed position measurements with respect to 1.34 ± 0.24 mm for maximal isometric contraction thickness with extended knee measurements (p = 0.058). CONCLUSIONS: This study found that intra- and inter-examiner reliability of M-mode ultrasound imaging of the soleus muscle was excellent in asymptomatic subjects and the soleus muscle activity was different between the position with the knee extended and the position with the knee flexed.

19.
Phys Ther Sport ; 43: 70-76, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32114316

RESUMO

OBJECTIVES: The prevalence of myofascial pain syndrome varies from 21% 93%. Several studies have shown that myofascial induction is effective in treating myofascial pain syndrome. Although these techniques have shown some effectiveness in clinical practice, there have been little study into their effects, and have deep effects. The purpose of this study was to investigate if the application of a single myofascial induction technique for each foot, targeted to the plantar fascia resulted in changes in balance and footprint variables. DESIGN: A quasi-experimental study. SETTING: An outpatient clinic. SUBJECTS: 20 healthy participants (12 females and 8 males) were evaluated pre and post Myofascial induction technique for each foot in plantar fascia during 5 min. METHODS: We measured static footprint and stabilometry variables in asymptomatic subjects. The footprint surface area was divided: bilateral rear foot, bilateral midfoot, bilateral fore foot. RESULTS: We found differences in the footprint variables: maximun pressure in forefoot (p = 0.025), surface in forefoot (p = 0.03). The myofascial induction has no effects on stabilometry variables. CONCLUSIONS: The immediate effects of the longitudinal technique of myofascial induction of the plantar fascia are the increase of surface and maximum pressure in fore foot.


Assuntos
Pé/fisiologia , Manipulações Musculoesqueléticas , Síndromes da Dor Miofascial/fisiopatologia , Síndromes da Dor Miofascial/terapia , Equilíbrio Postural/fisiologia , Pressão , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade
20.
JMIR Mhealth Uhealth ; 8(4): e14702, 2020 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-32238337

RESUMO

BACKGROUND: Hypertension is a global public health issue and is closely related to chronic kidney disorder (CKD). In people with CKD, strict monitoring of blood pressure is an important part of therapy. OBJECTIVE: The aim of this research was to validate the iHealth Track blood pressure monitoring device for patients with CKD according to the European Society of Hypertension International Protocol 2010 (ESH-IP2). METHODS: In total, 33 patients who received hemodialysis in Plasencia participated in the study. There were 9 successive measurements made, which conformed to the ESH-IP2. We calculated the differences between the standard reference device (Omron M3 Intellisense) and the test device (iHealth Track) for blood pressure and heart rate values. For 99 total comparisons of paired measurements, we classified differences into various categories (≤5 mmHg, ≤10 mmHg, and ≤15 mmHg for blood pressure; ≤3, ≤5, and ≤8 beats per minute for heart rate). RESULTS: In 90 of 99 systolic blood pressure and 89 of 99 diastolic blood pressure comparisons between the devices, measurement differences were within 5 mmHg. In 81 of 99 heart rate comparisons between the devices, measurement differences were within 3 beats per minute. The mean differences between the test and reference standard measurements were 3.27 (SD 2.99) mmHg for systolic blood pressure, 3.59 (SD 4.55) mmHg for diastolic blood pressure, and 2.18 (SD 2.75) beats per minute for heart rate. We also observed that for both systolic and diastolic blood pressure, 31 of 33 participants had at least two of three comparisons between the devices with measurement differences less than 5 mmHg. For heart rate, 28 of 33 patients had at least two of three comparisons between the devices with measurement differences less than 3 beats per minute. CONCLUSIONS: To our knowledge, this is the first study to show that iHealth Track meets the requirements of the ESH-IP2 in patients with CKD. Therefore, the iHealth Track is suitable for use in renal patients.


Assuntos
Monitorização Ambulatorial da Pressão Arterial , Hipertensão , Insuficiência Renal Crônica , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Determinação da Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Feminino , Humanos , Hipertensão/diagnóstico , Masculino , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA