Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Magn Reson Med ; 87(1): 312-322, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34453462

RESUMO

PURPOSE: Magnetic particle imaging (MPI) is a new imaging modality that sensitively and specifically detects superparamagnetic iron oxide nanoparticles (SPIOs). MRI cell tracking with SPIOs has very high sensitivity, but low specificity and quantification is difficult. MPI could overcome these limitations. There are no reports of micron-sized iron oxide particles (MPIO) for cell tracking by MPI. Therefore, the goal was to evaluate if MPIO can be used for in vivo detection and quantification of cancer cells distributed in the mouse brain by MPI. METHODS: In the first experiment mice were injected with either 2.5 × 105 or 5.0 × 105 MPIO-labeled cancer cells and MPI was performed ex vivo. In a second experiment, mice received either 2.5 × 105 or 5.0 × 104 MPIO-labeled cells and MPI was performed in vivo. In a third experiment, mice were injected with 5.0 × 104 cells, labeled with either MPIO or ferucarbotran, and MPI was performed in vivo. RESULTS: MPIO-labeled cells were visible in all MPI images of the mouse brain. The MPI signal and iron content measurements were greater for brains of mice that were injected with higher numbers of MPIO-labeled cells. Ferucarbotran-labeled cells were not detected in the brain by MPI. CONCLUSION: This is the first example of the use of MPIO for cell tracking with MPI. With an intracardiac cell injection, ~15% of cells will arrest in the brain vasculature. For our lowest cell injection of 5.0 × 104 cells, this was ~10 000 cells, distributed throughout the brain.


Assuntos
Compostos Férricos , Neoplasias , Animais , Encéfalo/diagnóstico por imagem , Rastreamento de Células , Imageamento por Ressonância Magnética , Camundongos , Microesferas
2.
Nanoscale ; 13(12): 6016-6023, 2021 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-33683241

RESUMO

Due to their innate tumour homing capabilities, in recent years, circulating tumour cells (CTCs) have been engineered to express therapeutic genes for targeted treatment of primary and metastatic lesions. Additionally, previous studies have incorporated optical or PET imaging reporter genes to enable noninvasive monitoring of therapeutic CTCs in preclinical tumour models. An alternative method for tracking cells is to pre-label them with imaging probes prior to transplantation into the body. This is typically more sensitive to low numbers of cells since large amounts of probe can be concentrated in each cell. The objective of this work was to evaluate magnetic particle imaging (MPI) for the detection of iron-labeled experimental CTCs. CTCs were labeled with micro-sized iron oxide (MPIO) particles, administered via intra-cardiac injection in tumour bearing mice and were detected in the tumour region of the mammary fat pad. Iron content and tumour volumes were calculated. Ex vivo MPI of the tumours and immunohistochemistry were used to validate the imaging data. Here, we demonstrate for the first time the ability of MPI to sensitively detect systemically administered iron-labeled CTCs and to visualize tumour self-homing in a murine model of human breast cancer.


Assuntos
Neoplasias da Mama , Células Neoplásicas Circulantes , Animais , Neoplasias da Mama/diagnóstico por imagem , Diagnóstico por Imagem , Genes Reporter , Humanos , Fenômenos Magnéticos , Imageamento por Ressonância Magnética , Camundongos
3.
Tomography ; 6(4): 315-324, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33364421

RESUMO

Many labs have been developing cellular magnetic resonance imaging (MRI), using both superparamagnetic iron oxide nanoparticles (SPIONs) and fluorine-19 (19F)-based cell labels, to track immune and stem cells used for cellular therapies. Although SPION-based MRI cell tracking has very high sensitivity for cell detection, SPIONs are indirectly detected owing to relaxation effects on protons, producing negative magnetic resonance contrast with low signal specificity. Therefore, it is not possible to reliably quantify the local tissue concentration of SPION particles, and cell number cannot be determined. 19F-based cell tracking has high specificity for perfluorocarbon-labeled cells, and 19F signal is directly related to cell number. However, 19F MRI has low sensitivity. Magnetic particle imaging (MPI) is a new imaging modality that directly detects SPIONs. SPION-based cell tracking using MPI displays great potential for overcoming the challenges of MRI-based cell tracking, allowing for both high cellular sensitivity and specificity, and quantification of SPION-labeled cell number. Here we describe nanoparticle and MPI system factors that influence MPI sensitivity and resolution, quantification methods, and give our perspective on testing and applying MPI for cell tracking.


Assuntos
Rastreamento de Células , Nanopartículas , Meios de Contraste , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA