1.
Sensors (Basel) ; 22(4)2022 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-35214230

RESUMO

The combination of interstitial hyperthermia treatment (IHT) with high dose rate brachytherapy (HDR-BT) can improve clinical outcomes since it highly enhances the efficiency of cell kill, especially when applied simultaneously. Therefore, we have developed the ThermoBrachy applicators. To effectively apply optimal targeted IHT, treatment planning is considered essential. However, treatment planning in IHT is rarely applied as it is regarded as difficult to accurately calculate the deposited energy in the tissue in a short enough time for clinical practice. In this study, we investigated various time-efficient methods for fast computation of the electromagnetic (EM) energy deposition resulting from the ThermoBrachy applicators. Initially, we investigated the use of an electro-quasistatic solver. Next, we extended our investigation to the application of geometric simplifications. Furthermore, we investigated the validity of the superpositioning principle, which can enable adaptive treatment plan optimization without the need for continuous recomputation of the EM field. Finally, we evaluated the accuracy of the methods by comparing them to the golden standard Finite-Difference Time-Domain calculation method using gamma-index analysis. The simplifications considerably reduced the computation time needed, improving from >12 h to a few seconds. All investigated methods showed excellent agreement with the golden standard by showing a >99% passing rate with 1%/0.5 mm Dose Difference and Distance-to-Agreement criteria. These results allow the proposed electromagnetic simulation method to be used for fast and accurate adaptive treatment planning.


Assuntos
Braquiterapia , Hipertermia Induzida , Braquiterapia/métodos , Simulação por Computador , Fenômenos Eletromagnéticos , Hipertermia Induzida/métodos , Dosagem Radioterapêutica
2.
Int J Hyperthermia ; 38(1): 1660-1671, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34814784

RESUMO

OBJECTIVE: In High Dose Rate Brachytherapy for prostate cancer there is a need for a new way of increasing cancer cell kill in combination with a stable dose to the organs at risk. In this study, we propose a novel ThermoBrachy applicator that offers the unique ability to apply interstitial hyperthermia while simultaneously serving as an afterloading catheter for high dose rate brachytherapy for prostate cancer. This approach achieves a higher thermal enhancement ratio than in sequential application of radiation and hyperthermia and has the potential to decrease the overall treatment time. METHODS: The new applicator uses the principle of capacitively coupled electrodes. We performed a proof of concept experiment to demostrate the feasibility of the proposed applicator. Moreover, we used electromagnetic and thermal simulations to evaluate the power needs and temperature homogeneity in different tissues. Furthermore we investigated whether dynamic phase and amplitude adaptation can be used to improve longitudinal temperature control. RESULTS: Simulations demonstrate that the electrodes achieve good temperature homogeneity in a homogenous phantom when following current applicator spacing guidelines. Furthermore, we demonstrate that by dynamic phase and amplitude adaptation provides a great advancement for further adaptability of the heating pattern. CONCLUSIONS: This newly designed ThermoBrachy applicator has the potential to revise the interest in interstitial thermobrachytherapy, since the simultaneous application of radiation and hyperthermia enables maximum thermal enhancement and at maximum efficiency for patient and organization.


Assuntos
Braquiterapia , Hipertermia Induzida , Neoplasias da Próstata , Humanos , Masculino , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Temperatura
3.
Sensors (Basel) ; 21(3)2021 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-33499122

RESUMO

There is a growing interest to improve the quality of life of blind people. An implanted intracortical prosthesis could be the last resort in many cases of visual impairment. Technology at this moment is at a stage that implementation is at sight. Making the data communication to and from the implanted electrodes wireless is beneficial to avoid infection and to ease mobility. Here, we focus on the stimulation side, or downlink, for which we propose a low-power non-coherent digital demodulator on the implanted receiver. The experimentally demonstrated downlink is on a scaled-down version at a 1 MHz carrier frequency showing a data rate of 125 kbps. This provides proof of principle for the system with a 12 MHz carrier frequency and a data rate of 4 Mbps, which consumes under 1 mW at the receiver side in integrated circuit (IC) simulation. Due to its digital architecture, the system is easily adjustable to an ISM frequency band with its power consumption scaling linearly with the carrier frequency. The tested system uses off-the-shelf coils, which gave sufficient bandwidth, while staying within safe SAR limits. The digital receiver achieved a reduction in power consumption by skipping clock cycles of redundant bits. The system shows a promising pathway to a low-power wireless-enabled visual prosthesis.


Assuntos
Próteses Visuais , Amplificadores Eletrônicos , Desenho de Equipamento , Qualidade de Vida , Telemetria , Tecnologia sem Fio
4.
Int J Hyperthermia ; 34(6): 697-703, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-28828891

RESUMO

In this work, a novel magnetic resonance (MR)-compatible microwave antenna was designed and validated in a small animal superficial hyperthermia applicator. The antenna operates at 2.45 GHz and matching is made robust against production and setup inaccuracies. To validate our theoretical concept, a prototype of the applicator was manufactured and tested for its properties concerning input reflection, sensitivity for setup inaccuracies, environment temperature stability and MR-compatibility. The experiments show that the applicator indeed fulfils the requirements for MR-guided hyperthermia investigation in small animals: it creates a small heating focus (<1 cm3), has a stable and reliable performance (S11< -15 dB) for all working conditions and is MR-compatible.


Assuntos
Hipertermia Induzida/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Camundongos
5.
Phys Imaging Radiat Oncol ; 31: 100606, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39100864

RESUMO

Background and purpose: Integrating simultaneous interstitial hyperthermia in high-dose-rate brachytherapy treatments (HDR-BT) is expected to lead to enhanced therapeutic effect. However, there is currently no device available for such an integration. In this study, we presented and validated the thermobrachytherapy (TBT) preclinical prototype system that is able to seamlessly integrate into the HDR-BT workflow. Materials and methods: The TBT system consisted of an advanced radiofrequency power delivery and control system, dual-function interstitial applicators, and integrated connection and impedance matching system. The efficiency and minimum heating ability of the system was calculated performing calorimetric experiments. The effective-heating-length and heating pattern was evaluated using single-applicator split phantom experiments. The heating independence between applicators, the ability of the system to adaptable and predictable temperature steering was evaluated using multi-applicator split phantom experiments. Results: The system satisfied interstitial hyperthermia requirements. It demonstrated 50 % efficiency and ability to reach 6 °C temperature increase in 6 min. Effective-heating-length of the applicator was 43.7 mm, following the initial design. Heating pattern interference between applicators was lower than recommended. The system showed its ability to generate diverse heating patterns by adjusting the phase and amplitude settings of each electrode, aligning well with simulations (minimum agreement of 88 %). Conclusions: The TBT preclinical prototype system complied with IHT requirements, and agreed well with design criteria and simulations, hence performing as expected. The preclinical prototype TBT system can now be scaled to an in-vivo validation prototype, including an adaptable impedance matching solution, appropriate number of channels, and ensuring biocompatibility and regulatory compliance.

6.
Brain Sci ; 12(5)2022 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-35624997

RESUMO

Conventional transcranial electric stimulation(tES) using standard anatomical positions for the electrodes and standard stimulation currents is frequently not sufficiently selective in targeting and reaching specific brain locations, leading to suboptimal application of electric fields. Recent advancements in in vivo electric field characterization may enable clinical researchers to derive better relationships between the electric field strength and the clinical results. Subject-specific electric field simulations could lead to improved electrode placement and more efficient treatments. Through this narrative review, we present a processing workflow to personalize tES for focal epilepsy, for which there is a clear cortical target to stimulate. The workflow utilizes clinical imaging and electroencephalography data and enables us to relate the simulated fields to clinical outcomes. We review and analyze the relevant literature for the processing steps in the workflow, which are the following: tissue segmentation, source localization, and stimulation optimization. In addition, we identify shortcomings and ongoing trends with regard to, for example, segmentation quality and tissue conductivity measurements. The presented processing steps result in personalized tES based on metrics like focality and field strength, which allow for correlation with clinical outcomes.

7.
Cancers (Basel) ; 14(6)2022 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-35326574

RESUMO

In high-dose-rate brachytherapy (HDR-BT) for prostate cancer treatment, interstitial hyperthermia (IHT) is applied to sensitize the tumor to the radiation (RT) dose, aiming at a more efficient treatment. Simultaneous application of HDR-BT and IHT is anticipated to provide maximum radiosensitization of the tumor. With this rationale, the ThermoBrachyTherapy applicators have been designed and developed, enabling simultaneous irradiation and heating. In this research, we present a method to optimize the three-dimensional temperature distribution for simultaneous HDR-BT and IHT based on the resulting equivalent physical dose (EQDphys) of the combined treatment. First, the temperature resulting from each electrode is precomputed. Then, for a given set of electrode settings and a precomputed radiation dose, the EQDphys is calculated based on the temperature-dependent linear-quadratic model. Finally, the optimum set of electrode settings is found through an optimization algorithm. The method is applied on implant geometries and anatomical data of 10 previously irradiated patients, using reported thermoradiobiological parameters and physical doses. We found that an equal equivalent dose coverage of the target can be achieved with a physical RT dose reduction of 20% together with a significantly lower EQDphys to the organs at risk (p-value < 0.001), even in the least favorable scenarios. As a result, simultaneous ThermoBrachyTherapy could lead to a relevant therapeutic benefit for patients with prostate cancer.

8.
Micromachines (Basel) ; 12(4)2021 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-33917720

RESUMO

Brain-on-chip (BoC) models are tools for reproducing the native microenvironment of neurons, in order to study the (patho)physiology and drug-response of the brain. Recent developments in BoC techniques focus on steering neurons in their activity via microfabrication and via computer-steered feedback mechanisms. These cultures are often studied through calcium imaging (CI), a method for visualizing the cellular activity through infusing cells with a fluorescent dye. CAlciumImagingAnalyser 2.0 (CALIMA 2.0) is an updated version of a software tool that detects and analyzes fluorescent signals and correlates cellular activity to identify possible network formation in BoC cultures. Using three previous published data sets, it was demonstrated that CALIMA 2.0 can analyze large data sets of CI-data and interpret cell activity to help study the activity and maturity of BoC cultures. Last, an analysis of the processing speed shows that CALIMA 2.0 is sufficiently fast to process data sets with an acquisition rate up to 5 Hz in real-time on a medium-performance computer.