RESUMO
The ability to distinguish between severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) is of ongoing interest due to differences in transmissibility, responses to vaccination, clinical prognosis, and therapy. Although detailed genetic characterization requires whole-genome sequencing (WGS), targeted nucleic acid amplification tests can serve a complementary role in clinical settings, as they are more rapid and accessible than sequencing in most laboratories. We designed and analytically validated a two-reaction multiplex reverse transcription-quantitative PCR (RT-qPCR) assay targeting spike protein mutations L452R, E484K, and N501Y in reaction 1 and del69-70, K417N, and T478K in reaction 2. This assay had 95 to 100% agreement with WGS for 502 upper respiratory tract swab samples collected between 26 April 2021 and 1 August 2021, consisting of 43 Alpha, 2 Beta, 20 Gamma, 378 Delta, and 59 non-VOC infections. Validation in a separate group of 230 WGS-confirmed Omicron variant samples collected in December 2021 and January 2022 demonstrated 100% agreement. This RT-qPCR-based approach can be implemented in clinical laboratories already performing SARS-CoV-2 nucleic acid amplification tests to assist in local epidemiological surveillance and clinical decision-making.
Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Reação em Cadeia da Polimerase Multiplex , Mutação , Reação em Cadeia da Polimerase em Tempo Real , Transcrição Reversa , SARS-CoV-2/genética , Glicoproteína da Espícula de Coronavírus/genéticaRESUMO
Pooled nucleic acid amplification tests for severe acute respiratory syndrome coronavirus 2 could increase availability of testing at decreased cost. However, the effect of dilution on analytical sensitivity through sample pooling has not been well characterized. We tested 1,648 prospectively pooled specimens by using 3 nucleic acid amplification tests for severe acute respiratory syndrome coronavirus 2: a laboratory-developed real-time reverse transcription PCR targeting the envelope gene, and 2 commercially available Panther System assays targeting open reading frame 1ab. Positive percent agreement (PPA) of pooled versus individual testing ranged from 71.7% to 82.6% for pools of 8 and from 82.9% to 100.0% for pools of 4. We developed and validated an independent stochastic simulation model to estimate effects of dilution on PPA and efficiency of a 2-stage pooled real-time reverse transcription PCR testing algorithm. PPA was dependent on the proportion of tests with positive results, cycle threshold distribution, and assay limit of detection.
Assuntos
Teste para COVID-19/métodos , COVID-19/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , SARS-CoV-2/isolamento & purificação , COVID-19/virologia , Técnicas de Laboratório Clínico/métodos , Reações Falso-Negativas , Humanos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/normas , Estudos Prospectivos , SARS-CoV-2/genética , Sensibilidade e Especificidade , Manejo de Espécimes , Processos EstocásticosRESUMO
The emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants with concerning phenotypic mutations is of public health interest. Genomic surveillance is an important tool for a pandemic response, but many laboratories do not have the resources to support population-level sequencing. We hypothesized that a nucleic acid amplification test (NAAT) to genotype mutations in the viral spike protein could facilitate high-throughput variant surveillance. We designed and analytically validated a one-step multiplex allele-specific reverse transcriptase PCR (RT-qPCR) to detect three nonsynonymous spike protein mutations (L452R, E484K, N501Y). Assay specificity was validated with next-generation whole-genome sequencing. We then screened a large cohort of SARS-CoV-2-positive specimens from our San Francisco Bay Area population. Between 1 December 2020 and 1 March 2021, we screened 4,049 unique infections by genotyping RT-qPCR, with an assay failure rate of 2.8%. We detected 1,567 L452R mutations (38.7%), 34 N501Y mutations (0.84%), 22 E484K mutations (0.54%), and 3 (0.07%) E484K plus N501Y mutations. The assay had perfect (100%) concordance with whole-genome sequencing of a validation subset of 229 specimens and detected B.1.1.7, B.1.351, B.1.427, B.1.429, B.1.526, and P.2 variants, among others. The assay revealed the rapid emergence of the L452R variant in our population, with a prevalence of 24.8% in December 2020 that increased to 62.5% in March 2021. We developed and clinically implemented a genotyping RT-qPCR to conduct high-throughput SARS-CoV-2 variant screening. This approach can be adapted for emerging mutations and immediately implemented in laboratories already performing NAAT worldwide using existing equipment, personnel, and extracted nucleic acid.
Assuntos
COVID-19 , SARS-CoV-2 , Monitoramento Epidemiológico , Genótipo , Humanos , Reação em Cadeia da Polimerase Via Transcriptase ReversaRESUMO
BACKGROUND: Accurate diagnosis of malaria is important for effective disease management and control. In Cameroon, presumptive clinical diagnosis, thick-film microscopy (TFM), and rapid diagnostic tests (RDT) are commonly used to diagnose cases of Plasmodium falciparum malaria. However, these methods lack sensitivity to detect low parasitaemia. Polymerase chain reaction (PCR), on the other hand, enhances the detection of sub-microscopic parasitaemia making it a much-needed tool for epidemiological surveys, mass screening, and the assessment of interventions for malaria elimination. Therefore, this study sought to determine the frequency of cases missed by traditional methods that are detected by PCR. METHODS: Blood samples, collected from 551 febrile Cameroonian patients between February 2014 and February 2015, were tested for P. falciparum by microscopy, RDT and PCR. The hospital records of participants were reviewed to obtain data on the clinical diagnosis made by the health care worker. RESULTS: The prevalence of malaria by microscopy, RDT and PCR was 31%, 45%, and 54%, respectively. However, of the 92% of participants diagnosed as having clinical cases of malaria by the health care worker, 38% were malaria-negative by PCR. PCR detected 23% and 12% more malaria infections than microscopy and RDT, respectively. A total of 128 (23%) individuals had sub-microscopic infections in the study population. The sensitivity of microscopy, RDT, and clinical diagnosis was 57%, 78% and 100%; the specificity was 99%, 94%, and 17%; the positive predictive values were 99%, 94%, and 59%; the negative predictive values were 66%, 78%, and 100%, respectively. Thus, 41% of the participants clinically diagnosed as having malaria had fever caused by other pathogens. CONCLUSIONS: Malaria diagnostic methods, such as TFM and RDT missed 12-23% of malaria cases detected by PCR. Therefore, traditional diagnostic approaches (TFM, RDT and clinical diagnosis) are not adequate when accurate epidemiological data are needed for monitoring malaria control and elimination interventions.
Assuntos
Sangue/parasitologia , Testes Diagnósticos de Rotina/métodos , Imunoensaio/métodos , Malária Falciparum/diagnóstico , Microscopia/métodos , Plasmodium falciparum/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Camarões , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Plasmodium falciparum/citologia , Plasmodium falciparum/genética , Plasmodium falciparum/imunologia , Sensibilidade e Especificidade , Inquéritos e Questionários , Adulto JovemRESUMO
BACKGROUND: Current malaria diagnostic methods require blood collection, that may be associated with pain and the risk of transmitting blood-borne pathogens, and often create poor compliance when repeated sampling is needed. On the other hand, the collection of saliva is minimally invasive; but saliva has not been widely used for the diagnosis of malaria. The aim of this study was to evaluate the diagnostic performance of saliva collected and stored at room temperature using the OMNIgene®â¢ORAL kit for diagnosing Plasmodium falciparum malaria. METHODS: Paired blood and saliva samples were collected from 222 febrile patients in Cameroon. Saliva samples were collected using the OMNIgene®â¢ORAL (OM-501) kit and stored at room temperature for up to 13 months. Thick blood film microscopy (TFM) was used to detect P. falciparum blood-stage parasites in blood. Detection of P. falciparum DNA in blood and saliva was based on amplification of the multi-copy 18 s rRNA gene using the nested-polymerase chain reaction (nPCR). RESULTS: Prevalence of malaria detected by TFM, nPCR-saliva and nPCR-blood was 22, 29, and 35%, respectively. Using TFM as the gold standard, the sensitivity of nPCR-saliva and nPCR-blood in detecting P. falciparum was 95 and 100%, respectively; with corresponding specificities of 93 and 87%. When nPCR-blood was used as gold standard, the sensitivity of nPCR-saliva and microscopy was 82 and 68%, respectively; whereas, the specificity was 99 and 100%, respectively. Nested PCR-saliva had a very good agreement with both TFM (kappa value 0.8) and blood PCR (kappa value 0.8). At parasitaemia > 10,000 parasites/µl of blood, the sensitivity of nPCR-saliva was 100%. Nested PCR-saliva detected 16 sub-microscopic malaria infections. One year after sample collection, P. falciparum DNA was detected in 80% of saliva samples stored at room temperature. CONCLUSIONS: Saliva can potentially be used as an alternative non-invasive sample for the diagnosis of malaria and the OMNIgene®â¢ORAL kit is effective at transporting and preserving malaria parasite DNA in saliva at room temperature. The technology described in this study for diagnosis of malaria in resource-limited countries adds on to the armamentarium needed for elimination of malaria.
Assuntos
Testes Diagnósticos de Rotina/métodos , Malária Falciparum/diagnóstico , Plasmodium falciparum/isolamento & purificação , Saliva/parasitologia , Adolescente , Adulto , Idoso , Camarões/epidemiologia , Criança , Pré-Escolar , Testes Diagnósticos de Rotina/instrumentação , Feminino , Humanos , Malária Falciparum/epidemiologia , Masculino , Microscopia/métodos , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase/métodos , Prevalência , Temperatura , Adulto JovemRESUMO
BACKGROUND: The current roll-out of rapid diagnostic tests (RDTs) in many endemic countries has resulted in the reporting of fewer cases of malaria-attributed illnesses. However, lack of knowledge of the prevalence of other febrile illnesses and affordable diagnostic tests means that febrile patients are not managed optimally. This study assessed the prevalence of commonly treatable or preventable febrile illnesses in children between 6 months and 15 years using rapid diagnostic tests at the point-of-care. METHODS: Febrile children were enrolled between February-April 2014 at a health facility after obtaining informed consent from parent. Eligible participants were aged 6 months-15 years with a history of fever in the last 24 h or axillary temperature ≥38 °C at consultation. All participants were tested using RDTs for malaria, typhoid, toxoplasmosis and rubella. Malaria parasites were further identified by microscopy and PCR. Clinical and household characteristics were recorded and association with pathogens determined. RESULTS: Of the 315 children enrolled, the mean age was 5.8 ± 3.8 years. Stomach pain (41.2 %) was the most reported symptom. Prior to attending the health facility, 70.8 % had taken antipyretics, 27.9 % antimalarials, 11.4 % antibiotics and 13.3 % antifungal drugs. Among 315 children with fever, based on RDTs, 56.8 % were infected with malaria, 4.4 % with typhoid, 3.2 % with acute toxoplasmosis, and 1.3 % with rubella (all positive for rubella were in the same family and not vaccinated). All non-malarial infections were co-infections and approximately 30 % of the fever cases went un-diagnosed. Malaria prevalence by microscopy and PCR was 43.4 and 70.2 % respectively. The sensitivity and specificity of RDTs for the diagnosis of malaria were 75.98 and 100 % respectively, with 0.73 measurement agreement between RDTs and microscopy while that of RDT and PCR were 81 and 100 % respectively with a K value of 0.72. The use of Insecticide Treated Bednets was 44 %. There was a significant association between ITN non-usage and malaria (p = 0. 029) as well as drinking water and presence of typhoid (p = 0.047). No association was observed between type of housing and malaria, or toxoplasmosis and raising cats. CONCLUSION: Though malaria still remains the major cause of fever in children, using RDTs for other treatable febrile illnesses like typhoid and toxoplasmosis could facilitate the optimal management of febrile illnesses in children especially when these occur as co-infections with malaria.
Assuntos
Malária/epidemiologia , Rubéola (Sarampo Alemão)/epidemiologia , Toxoplasmose/epidemiologia , Febre Tifoide/epidemiologia , Adolescente , Animais , Antimaláricos/uso terapêutico , Camarões/epidemiologia , Gatos , Criança , Pré-Escolar , Coinfecção/tratamento farmacológico , Testes Diagnósticos de Rotina/métodos , Feminino , Febre/etiologia , Instalações de Saúde , Humanos , Lactente , Mosquiteiros Tratados com Inseticida , Malária/diagnóstico , Malária/tratamento farmacológico , Masculino , Microscopia , Sistemas Automatizados de Assistência Junto ao Leito , Reação em Cadeia da Polimerase , Rubéola (Sarampo Alemão)/diagnóstico , Sensibilidade e Especificidade , Toxoplasmose/diagnóstico , Toxoplasmose/tratamento farmacológico , Febre Tifoide/diagnósticoRESUMO
OBJECTIVES/HYPOTHESIS: To determine the effect of povidone-iodine (PVP-I) nasal sprays on nasopharyngeal (NP) viral load as assessed by cycle threshold (Ct) on quantitative polymerase chain reaction (qPCR) of SARS-CoV-2 in outpatients. STUDY DESIGN: Three arm, triple blinded, randomized, placebo-controlled clinical trial. METHODS: Participants were randomized within 5 days of testing positive for COVID-19 to receive nasal sprays containing placebo (0.9% saline), 0.5% PVP-I, or 2.0% PVP-I. NP swabs for qPCR analysis were taken at baseline, 1-hour post-PVP-I spray (two sprays/nostril), and 3 days post-PVP-I spray (20 sprays/nostril). Symptom and adverse event questionnaires were completed at baseline, day 3, and day 5. University of Pennsylvania Smell Identification Tests (UPSIT) were completed at baseline and day 30. RESULTS: Mean Ct values increased over time in all groups, indicating declining viral loads, with no statistically significant difference noted in the rate of change between placebo and PVP-I groups. The 2.0% PVP-I group showed statistically significant improvement in all symptom categories; however, it also reported a high rate of nasal burning. Olfaction via UPSIT showed improvement by at least one category in all groups. There were no hospitalizations or mortalities within 30 days of study enrollment. CONCLUSIONS: Saline and low concentration PVP-I nasal sprays are well tolerated. Similar reductions in SARS-CoV-2 NP viral load were seen over time in all groups. All treatment groups showed improvement in olfaction over 30 days. These data suggest that dilute versions of PVP-I nasal spray are safe for topical use in the nasal cavity, but that PVP-I does not demonstrate virucidal activity in COVID-19 positive outpatients. LEVEL OF EVIDENCE: 2 Laryngoscope, 132:2089-2095, 2022.
Assuntos
Tratamento Farmacológico da COVID-19 , SARS-CoV-2 , Humanos , Sprays Nasais , Povidona-Iodo/uso terapêutico , Solução Salina , Carga ViralRESUMO
BACKGROUND: Significant overlap exists between the symptoms of SARS-CoV-2 and other respiratory viruses. This poses a serious challenge to clinical diagnosis, laboratory testing, and infection control programs. OBJECTIVES: To evaluate the performance of the Hologic Panther Fusion Respiratory Assays (RA) compared to the GenMark ePlex Respiratory Pathogen Panel (RPP) and to assess the ability of the Panther Fusion to perform parallel testing of SARS-CoV-2 and other respiratory viruses from a single sample. STUDY DESIGN: A diagnostic comparison study was carried out using 375 clinical nasopharyngeal specimens. Assay performance was assessed by overall, positive, and negative percent agreement and Cohen's kappa coefficient. RESULTS: Overall agreement between the Fusion RA and ePlex RPP was 97.3 % (95 % CI 96.3-98.0), positive percent agreement was 97.2 % (95 % CI 93.0-99.2), negative percent agreement was 97.3 % (95 % CI 96.3-98.0), and the kappa coefficient was 0.85 (95 % CI 0.81-0.89). Forty additional viruses in 30 specimens were detected by Fusion that were not detected by ePlex. The maximum specimen throughput for parallel testing of the Fusion Respiratory Assays with SARS-CoV-2 was 275 samples in 20.7 h for Fusion SARS-CoV-2 and 350 samples in 20.0 h for Aptima Transcription Mediated Amplification SARS-CoV-2. CONCLUSION: Fusion RA demonstrated substantial agreement compared to the ePlex RPP. However, the Fusion detected respiratory viruses not identified by ePlex, consistent with higher clinical sensitivity. Workflows for parallel testing of respiratory pathogens and SARS-CoV-2 demonstrate that the Panther Fusion instrument provides a flexible, moderate to high throughput testing option for pandemic and seasonal respiratory viruses.
Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Nasofaringe/virologia , RNA Viral/isolamento & purificação , SARS-CoV-2/isolamento & purificação , Testes Diagnósticos de Rotina , Humanos , Influenza Humana/diagnóstico , Estudos Retrospectivos , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: The coronavirus disease 2019 (COVID-19) endgame may benefit from simple, accurate antibody testing to characterize seroprevalence and immunization coverage. OBJECTIVES: To evaluate the performance of the lateral flow QIAreach anti-SARS-CoV-2 Total rapid nanoparticle fluorescence immunoassay compared to reference isotype-specific IgG, IgM, and IgA SARS-CoV-2 ELISA using S1 or receptor binding domain (RBD) as antigens. STUDY DESIGN: A diagnostic comparison study was carried out using 154 well-characterized heparin plasma samples. Agreement between assays was assessed by overall, positive, and negative percent agreement and Cohen's kappa coefficient. RESULTS: Overall agreement between the QIAreach anti-SARS-CoV-2 Total and any anti-spike domain (S1 or RBD) antibody isotype was 96.0 % (95 % CI 89.8-98.8), the positive percent agreement was 97.6 % (95 % CI 91.0-99.9), the negative percent agreement was 88.2 % (95 % CI 64.4-98.0). The kappa coefficient was 0.86 (95 % CI 0.72 to 0.99). CONCLUSION: The QIAreach anti-SARS-CoV-2 Total rapid antibody test provides comparable performance to high-complexity, laboratory-based ELISA.
Assuntos
Anticorpos Antivirais/sangue , COVID-19/diagnóstico , Imunofluorescência/métodos , SARS-CoV-2/imunologia , Adulto , Idoso , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , NanopartículasRESUMO
Following the 2015 Zika virus (ZIKV) outbreaks in the South Pacific, Caribbean, and Americas, ZIKV has emerged as a serious threat due to its association with infantile microcephaly and other neurologic disorders. Despite an international effort to develop a safe and effective vaccine to combat congenital Zika syndrome and ZIKV infection, only DNA and mRNA vaccines encoding the precursor membrane (prM) and envelope (E) proteins, an inactivated-ZIKV vaccine, and a measles virus-based ZIKV vaccine are currently in phase I or II (prM/E DNA) clinical trials. A ZIKV vaccine based on a nonreplicating, recombinant subunit platform offers a higher safety profile than other ZIKV vaccine candidates but is still highly immunogenic, inducing high virus-neutralizing antibody titers. Here, we describe the production and purification of Drosophila melanogaster S2 insect cell-derived, soluble ZIKV E protein and evaluate its immunogenicity and efficacy in three different mouse strains. As expected, significant virus-specific antibody titers were observed when using formulations containing clinically relevant adjuvants. Immunized mice challenged with live virus demonstrate inhibition of virus replication. Importantly, plaque reduction neutralization tests (PRNTs) indicate the high-titer production of neutralizing antibodies, a correlate of protection in the defense against ZIKV infection. ZIKV challenge of immunocompetent mice led to full protection against viremia with two doses of adjuvanted vaccine candidates. These data demonstrate a proof of concept and establish recombinant subunit immunogens as an effective vaccine candidate against ZIKV infection. IMPORTANCE The recent outbreaks of Zika virus (ZIKV) infection in French Polynesia, the Caribbean, and the Americas have highlighted the severe neuropathological sequelae that such an infection may cause. The development of a safe, effective ZIKV vaccine is critical for several reasons: (i) the difficulty in diagnosing an active infection due to common nonspecific symptoms, (ii) the lack of a specific antiviral therapy, and (iii) the potentially devastating pathological effects of in utero infection. Moreover, a vaccine with an excellent safety profile, such as a nonreplicating, noninfectious vaccine, would be ideal for high-risk people (e.g., pregnant women, immunocompromised patients, and elderly individuals). This report describes the development of a recombinant subunit protein vaccine candidate derived from stably transformed insect cells expressing the ZIKV envelope protein in vitro, the primary antigen to which effective virus-neutralizing antibodies are engendered by immunized animals for several other flaviviruses; the vaccine candidate elicits effective virus-neutralizing antibodies against ZIKV and provides protection against ZIKV infection in mice.