Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38837477

RESUMO

INTRODUCTION: The underlying risks of asymptomatic embolization during high-power short-duration (HPSD) ablation for atrial fibrillation remain unclear. We aimed to evaluate microembolic signals (MESs) during HPSD ablation with power settings of 50 and 90 W in comparison with those during cryoballoon (CB) ablation using a novel carotid ultrasound-Doppler system that classifies solid and air bubble signals using real-time monitoring. METHODS AND RESULTS: Forty-seven patients underwent HPSD ablation using radiofrequency (RF), and 13 underwent CB ablation. MESs were evaluated using a novel pastable soft ultrasound probe equipped with a carotid ultrasound during pulmonary vein isolation. We compared the detailed MESs and their timing between RF and CB ablations. The number of MESs and solid signals were significantly higher in the RF group than in CB group (209 ± 229 vs. 79 ± 32, p = .047, and 83 ± 89 vs. 28 ± 17, p = .032, respectively). In RF ablation, the number of MESs, solid, and bubble signals per ablation point, or per second, was significantly higher at 90 W than at 50 W ablation. The MESs, solid, and bubble signals were detected more frequently in the bottom and anterior walls of the left pulmonary vein (LPV) ablation. In contrast, many MESs were observed before the first CB application and decreased chronologically as the procedure progressed. Signals were more prevalent during the CB interval rather than during the freezing time. Among the 28 patients, 4 exhibited a high-intensity area on postbrain magnetic resonance imaging (MRI). The MRI-positive group showed a trend of larger signal sizes than did the MRI-negative group. CONCLUSION: The number of MESs was higher in the HPSD RF group than in the CB group, with this risk being more pronounced in the 90 W ablation group. The primary detection site was the anterior wall of the LPV in RF and the first interval in CB ablation.

2.
Int Heart J ; 64(4): 570-576, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37518336

RESUMO

The concept of complex and high-risk indicated procedures using percutaneous coronary intervention (CHIP-PCI) has recently been defined. However, few studies have investigated the prognosis of patients after CHIP-PCI. We enrolled 322 consecutive patients who underwent CHIP-PCI. CHIP-PCI was defined as a procedure satisfying at least one criterion each for both patient and procedure characteristics, as follows: patient characteristics [age ≥ 75 years old, low left ventricular ejection fraction (LVEF), diabetes mellitus, acute coronary syndrome, previous coronary artery bypass surgery, peripheral arterial disease, severe chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and severe valvular disease] and procedure characteristics [unprotected left main disease, degenerated saphenous or radial artery grafts, severely calcified lesions, last patent conduit, chronic total occlusions, multivessel disease, and use of mechanical circulatory support]. On Kaplan-Meier analysis, 1-, 2-, and 3-year survival rates following CHIP-PCI was 93.8%, 89.2%, and 85.4%, respectively. Moreover, on Cox multivariate hazard analysis, age (≥ 75 years old) (hazard ratio: 4.01, 95% confidence interval: 1.92-8.38, P < 0.01), COPD (hazard ratio: 2.95, 95% confidence interval: 1.38-6.32, P < 0.01), low LVEF (hazard ratio: 3.35, 95% confidence interval: 1.55-7.22, P < 0.01), severe CKD (hazard ratio: 3.02, 95% confidence interval: 1.44-6.36, P < 0.01), and use of mechanical circulatory support (hazard ratio: 5.97, 95% confidence interval: 2.72-13.10, P < 0.01) remained significant predictors of mortality. In conclusion, we revealed the clinical outcomes after CHIP-PCI. The presence of advanced age, COPD, low LVEF, severe CKD, and mechanical circulatory support use might lead to worse clinical outcomes.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Doença Pulmonar Obstrutiva Crônica , Humanos , Idoso , Intervenção Coronária Percutânea/métodos , Ponte de Artéria Coronária , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Doença da Artéria Coronariana/cirurgia , Fatores de Risco
3.
J Cardiovasc Electrophysiol ; 33(12): 2447-2464, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36168875

RESUMO

INTRODUCTION: Data are limited regarding outcomes of cryoballoon ablation for atrial fibrillation (AF) in patients with heart failure (HF). This large-scale multicenter study aimed to evaluate the prognosis of patients with HF after cryoballoon ablation for AF. METHODS: Among 3655 patients undergoing cryoballoon ablation at 17 institutions, 549 patients (15%) (391 with paroxysmal AF and 158 with persistent AF) diagnosed with HF preoperatively were analyzed. Clinical endpoints were recurrence, mortality, and HF hospitalization after ablation. RESULTS: Most patients had a preserved left ventricular ejection fraction (LVEF) ≥ 50%. During a mean follow-up period of 25.7 months, recurrence, all-cause death, and HF hospitalization occurred in 29%, 4.0%, and 4.8%, respectively. Cardiac function on echocardiography and B-type natriuretic peptide (BNP) levels significantly improved postoperatively, and the effect was more pronounced in the nonrecurrence group. Major complications occurred in 33 patients (6.0%), but most complications were phrenic nerve palsy (3.6%). Although death and HF hospitalization occurred more frequently in patients with LVEF ≤ 40% (n = 73) and New York Heart Association (NYHA) class III-IV (n = 19) than other subgroups, the BNP levels, and LVEF significantly improved after ablation in all LVEF and NYHA class subgroups. High BNP levels, NHYA class, CHADS2 score, and structural heart disease, but not postablation recurrence, independently predicted death, and HF hospitalization on multivariate analysis. The patients with tachycardia-induced cardiomyopathy had better recovery of BNP levels and LVEF after ablation than those with structural heart disease. CONCLUSIONS: Cryoballoon ablation for AF in HF patients is feasible and leads to significantly improved cardiac function.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Estudos de Viabilidade , Resultado do Tratamento , Cardiopatias/cirurgia
4.
Heart Vessels ; 37(5): 765-774, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34636968

RESUMO

In cryoballoon ablation (CBA), a contrast medium is commonly used to confirm balloon occlusion of the pulmonary veins (PVs). However, a contrast medium cannot always be used in patients with renal dysfunction and allergy. The present study aimed to assess the efficacy and safety of CBA without the use of a contrast medium. We retrospectively examined consecutive patients with paroxysmal atrial fibrillation (PAF) who underwent first-time CBA. We compared the procedural results and outcomes in patients for whom a contrast medium was used (contrast group) and those from whom a contrast medium was not used (non-contrast group). In the non-contrast group, we used saline injection on the intracardiac echocardiography and pressure wave monitoring for PV occlusion. Fifty patients (200 PVs) and 22 patients (88 PVs) underwent CBA with and without a contrast medium, respectively. The success rate of PV isolation with CBA alone was 93% and 90% in the non-contrast and contrast groups, respectively (p = 0.40). The fluoroscopy time and nadir temperature were significantly lower in the non-contrast group as compared to that in the contrast group. The recurrence rate 1 year after ablation did not differ between the two groups (18% vs. 18%, p > 0.99). Furthermore, the number of reconnected PVs in patients with recurrence was significantly lower in the non-contrast group than in the contrast group (6% vs. 36%, p = 0.017). In conclusion, CBA using the intracardiac echocardiography and pressure monitoring approach without the use of a contrast medium was safe and efficient.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Ecocardiografia/métodos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
Int Heart J ; 63(1): 159-162, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35095065

RESUMO

We report here the case of a 92-year-old woman with atrial fibrillation bradycardia in which leadless pacemaker implantation was performed with a difficult delivery of the catheter sheath due to an extremely large right atrium. Using a snare technique with correction of the direction of the force on the catheter toward the right ventricle (RV) can result in successful delivery of the pacemaker catheter and stable placement of the pacemaker system in the RV septum. This specific snare technique has the potential to facilitate leadless pacemaker implantation safely in a severely dilated chamber of the heart, making this technique effective to use in clinical practice.


Assuntos
Fibrilação Atrial/terapia , Bradicardia/terapia , Cateterismo Cardíaco/métodos , Marca-Passo Artificial , Implantação de Prótese/métodos , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Bradicardia/complicações , Bradicardia/diagnóstico , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos
6.
J Cardiovasc Electrophysiol ; 32(11): 2933-2942, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34535938

RESUMO

INTRODUCTION: With regard to short-term outcome in atrial fibrillation (AF), the benefit of cryoballoon ablation (CBA) by pressing a balloon against the earliest pulmonary vein (PV) potential site during PV isolation (earliest potential [EP]-guided CBA) has been previously demonstrated. The present study aimed to evaluate the long-term outcome of the EP-guided CBA. METHODS AND RESULTS: This study included 136 patients from two randomized studies, who underwent CBA for paroxysmal AF for the first time. Patients were randomly assigned to the EP-guided and conventional CBA groups in each study. In the EP-guided CBA group, we pressed a balloon against the EP site when the time-to-isolation (TTI) after cryoapplication exceeded 60 and 45 s in the first and second studies, respectively. We compared the clinical outcomes for 1 year after the procedure between the EP-guided CBA group (68 patients) and the conventional CBA group (68 patients). The primary endpoint was the recurrence of atrial arrhythmia after ablation. No significant differences in baseline characteristics were observed between the two groups. Compared with the conventional CBA group, the EP-guided CBA group had a significantly higher success rate at TTI ≤ 90 s (98.5% vs. 90.0%, p < .001); lower touch-up rate and total cryoapplication; and shorter procedure time, and fluoroscopy time. The recurrence at 1 year after ablation was significantly lower in the EP-guided CBA group than in the conventional CBA group (6.0% vs. 19.4%; p = .019). CONCLUSIONS: The EP-guided CBA approach can facilitate the ablation procedure and achieve low recurrence at 1 year after ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ensaios Clínicos Controlados Aleatórios como Assunto , Recidiva , Resultado do Tratamento
7.
Heart Vessels ; 36(8): 1190-1200, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33496818

RESUMO

Electrophysiological studies have rarely evaluated the sites prone to pulmonary vein (PV) conduction gap during cryoballoon ablation (CBA) for atrial fibrillation (AF). In addition, no studies have analyzed the sequence of PV potentials just before PV isolation during CBA for AF. Of the 238 patients who underwent first-time CBA for paroxysmal AF, 115 PVs of 29 patients who underwent repeat session due to recurrence after the procedure were retrospectively evaluated in the study. We evaluated the disappearance pattern of PV potential and PV reconnection on intracardiac electrograms and investigated whether the conduction gap site of the PV was related to the last remaining earliest PV potential (EP) and sequence pattern during the first-time CBA. Time to isolation was observed in 81 PVs during the first-time CBA. At the repeat session, PV reconnection was only observed in 22 of 81 PVs. PV potentials disappeared with sequence changes in 36 PVs and without sequence changes in 38 PVs. Multivariate analysis demonstrated that disappearance of PV potentials without change in the EP site but with delay or disappearance of other PV potentials was independently associated with PV reconnection (12/22 PVs [55%] vs. 4/59 PVs [6.8%]; odds ratio 14.4; 95% confidence interval 3.75-55.5; p < 0.001). In 19 of 22 (86%) reconnected PVs, PV conduction gap sites at repeat ablation corresponded with the last remaining EP sites during first-time CBA. In conclusion, disappearance pattern of the PV potential and the last remaining EP during the CBA can predict PV reconnection and gap site.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
8.
Heart Vessels ; 36(6): 799-808, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33411012

RESUMO

The Clinical Frailty Scale (CFS) is a simple tool to assess patients' frailty and may help to predict adverse outcomes in elderly patients. The aim of the present study was to examine the impact of CFS on clinical outcomes and bleeding events after successful percutaneous coronary intervention (PCI) in ST-segment elevation myocardial infarction (STEMI). We enrolled 266 consecutive patients with STEMI who underwent primary PCI in between January 2015 and June 2018. Patients were categorized into two groups based on the CFS stages: CFS 1-3 and CFS ≥ 4. We collected the data and evaluated the relationship between the CFS grade and the incidence of major adverse cardiovascular events (MACE) and Bleeding Academic Research Consortium 3 or 5 bleeding events. Of these patients, CFS ≥ 4 was present in 59 (22.2%). During the follow-up, 37.3% in the CFS ≥ 4 group and 8.2% in the CFS 1-3 group experienced MACE. In Kaplan-Meier analysis, the proportion of MACE-free survival for 4 years was significantly lower in the CFS ≥ 4 group (log-rank P < 0.001). Additionally, the proportion of bleeding event-free survival was significantly lower in the CFS ≥ 4 group (log-rank P < 0.001). The CFS (per 1-grade increase) remained an independent significant predictor of MACE on multivariate Cox proportional hazard analysis [hazard ratio 1.39 (95% confidence interval: 1.08 to 1.79, P = 0.01)]. In conclusion, CFS was an independent predictor of future adverse cardiac events in patients with STEMI. Therefore, the assessment of CFS is crucial in this population.


Assuntos
Fragilidade/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Hemorragia Pós-Operatória/epidemiologia , Sistema de Registros , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Idoso , Feminino , Seguimentos , Fragilidade/epidemiologia , Humanos , Incidência , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Hemorragia Pós-Operatória/etiologia , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Fatores de Tempo
9.
Heart Vessels ; 35(2): 232-238, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31297640

RESUMO

No studies have evaluated both the time-to-isolation (TTI) and the sequence of pulmonary vein (PV) potentials in cryoballoon ablation (CBA) for atrial fibrillation (AF). This study aimed to prospectively evaluate the acute results of pulmonary vein isolation (PVI) using a novel CBA technique-the earliest potential (EP) of PV-guided CBA-in paroxysmal AF. We pressed a balloon against the earliest PV potential site during PVI when TTI could not be achieved within 60 s (EP-guided CBA group). We compared 32 patients consecutively treated by EP-guided CBA to 32 patients treated without pressing the balloon against the EP site (conventional CBA group). The cryoapplication protocol was the same, except with regard to the pressing of the balloon. All 256 PVs (EP-guided CBA group, 128 PVs; conventional CBA group, 128 PVs) were isolated successfully. The TTI observation rate was similar in both groups. Compared with conventional CBA, EP-guided CBA was associated with a lower non-success rate of TTI ≤ 90 s (9% vs. 26%; P = 0.040) and shorter left atrial dwell time (38 ± 9 vs. 46 ± 19 min; P = 0.036), total procedure time (76 ± 15 vs. 87 ± 23 min; P = 0.043), and fluoroscopy time (23 ± 8 vs. 30 ± 11 min; P = 0.006). This novel EP-guided CBA approach may help facilitate the ablation procedure.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
11.
Circ J ; 80(3): 627-38, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26823143

RESUMO

BACKGROUND: Elevated red blood cell distribution width (RDW) predicts poor prognosis in patients with cardiovascular diseases. However, little is known about the association between RDW and outcomes after catheter ablation of atrial fibrillation (AF). METHODS AND RESULTS: A total of 757 patients who underwent radiofrequency catheter ablation of AF were divided into heart failure (HF, n=79) and non-HF (n=678) groups; RDW was assessed as a predictor after catheter ablation in each. During a 22.3-month follow-up period, the baseline RDW in the HF group was greater in the recurrence group than in the non-recurrence group (14.5±2.0% vs. 13.5±0.9%, P=0.013). In contrast, no significant difference in RDW at baseline was found in the non-HF group between the recurrence and non-recurrence groups (13.3±0.8% vs. 13.2±0.8%, P=0.332, respectively). Multivariate analysis demonstrated that RDW (hazard ratio 1.20, 95% confidence interval 1.01-1.40, P=0.034) was an independent predictor of AF recurrence in the HF group. The cut-off values of RDW for the recurrence of AF and major adverse events in the HF group were 13.9% and 14.8%, respectively. CONCLUSIONS: High RDW is an independent predictor for the recurrence of AF and major adverse events in patients with HF after catheter ablation. RDW is a potential noninvasive marker in AF patients complicated with HF. (Circ J 2016; 80: 627-638).


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/cirurgia , Ablação por Cateter , Índices de Eritrócitos , Idoso , Fibrilação Atrial/diagnóstico , Feminino , Seguimentos , Insuficiência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Estudos Retrospectivos
12.
Pacing Clin Electrophysiol ; 39(3): 225-34, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26596862

RESUMO

BACKGROUND: Little is known about the association between B-type natriuretic peptide (BNP) levels and catheter ablation of atrial fibrillation (AF) in patients with heart failure. This study aimed to examine the impact of elimination of AF by catheter ablation on BNP levels in patients with left ventricular systolic dysfunction. METHODS: Fifty-four AF patients with left ventricular ejection fraction (LVEF) ≤ 50%, who underwent radiofrequency catheter ablation therapy of AF, were included. BNP sampling was performed at baseline, 3 days, and 1 month after ablation. RESULTS: After a follow-up period of 6 months, the BNP levels decreased significantly in the nonrecurrence group (n = 35; median 126.3 [interquartile 57.2-206.5] pg/mL, 63.5 [23.9-180.2] pg/mL, and 45.9 [21.9-160.3] pg/mL, P < 0.001, respectively), but not in the recurrence group (n = 19; 144.7 [87.1-217.3] pg/mL, 88.8 [12.9-213.2] pg/mL, and 118.5 [51.6-298.2] pg/mL, P = 0.368, respectively). The patients in the nonrecurrence group had a higher percentage relative reduction in BNP levels from baseline to 1 month after ablation than those in the recurrence group (56.5 [-9.0-77.4]% vs -2.4 [-47.1-60.9]%, P = 0.027). Additionally, a relative reduction in BNP levels significantly correlated with an increase in LVEF after ablation (r = 0.486, P < 0.001). CONCLUSIONS: Plasma BNP levels decreased significantly with successful catheter ablation of AF in patients with impaired LVEF. The decrease in BNP levels might be associated with early recovery of cardiac function and subsequent maintenance of sinus rhythm at follow-up.


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/cirurgia , Peptídeo Natriurético Encefálico/sangue , Fibrilação Atrial/diagnóstico , Biomarcadores/sangue , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 39(11): 1191-1197, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27723112

RESUMO

BACKGROUND: Although several prognostic factors of atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) have been investigated, the accurate prediction of AF recurrence remains difficult. We propose an electrocardiogram (ECG) index, the P-wave force (PWF), which is the product of the amplitude of the negative terminal phase of the P wave in the V1 electrode and the filtered P-wave duration, obtained by a signal-averaged P-wave analysis. This study was conducted to evaluate the impact of the PWF on the recurrence of AF after PVI. METHODS: We retrospectively evaluated 79 paroxysmal AF patients (64 ± 9 years, 56 males) who underwent PVI by cryoballoon ablation. Standard 12-lead ECG and a P-wave signal-averaged electrocardiogram (SAECG) were recorded the day before and 1 month after the PVI procedure. RESULTS: During the mean follow-up of 10.2 months, AF recurred in 11 (14%) patients. The PWF 1 month after ablation was significantly higher in the recurrence group compared to that in the nonrecurrence group (8.8 ± 3.1 mVms vs 6.5 ± 2.9 mVms, P = 0.017). The patients with a PWF value ≥9.3 mVms had a significantly greater risk of recurrence after the ablation compared to the patients with a PWF value <9.3 mVms (log-rank test, P < 0.001). CONCLUSION: Higher PWF after cryoballoon ablation was associated with poor prognosis during follow-up. The PWF may be a useful and noninvasive marker to predict the recurrence of AF.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia , Veias Pulmonares/cirurgia , Adulto , Idoso , Criocirurgia , Feminino , Seguimentos , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Prognóstico , Recidiva , Estudos Retrospectivos
14.
Heart Vessels ; 31(9): 1553-61, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26498940

RESUMO

The relationship between body mass index (BMI) and the prognosis of elderly patients with atrial fibrillation (AF) is unknown. We aimed to examine the association of body weight with the clinical outcomes among Japanese elderly patients with a history of documented AF. This observational study of AF patients from an outpatients clinic in Nagoya University Hospital included 413 patients ≥70 years old (99 obese: BMI ≥25 kg/m(2); 256 normal weight: BMI 18.5-24.9 kg/m(2); and 58 underweight patients: BMI <18.5 kg/m(2)). The mean age was 77.5 ± 5.6 years. During a mean follow-up of 19.0 months, all-cause death occurred in 23 patients (obese 1 %, normal weight 5.1 %, and underweight 16 %). The major adverse events including all-cause death, stroke or transient ischemic attack, heart failure requiring admission, and acute coronary syndrome were observed in 53 patients (obese 5.1 %, normal weight 13 %, and underweight 26 %). After adjusting for confounding factors, the underweight group had a significantly greater risk for all-cause death [hazard ratio (HR) 2.91, 95 % confidence interval (CI) 1.12-7.60, p = 0.029], and major adverse events (HR 2.45, 95 % CI 1.25-4.78, p = 0.009) than the normal weight group. In contrast, the obese group had a better prognosis in major adverse events compared with the normal weight group (HR 0.34, 95 % CI 0.13-0.89, p = 0.029). In conclusion, lower BMI was independently associated with poor outcomes among older AF patients. The association between obesity and better prognosis in elderly AF patients was also found.


Assuntos
Fibrilação Atrial/complicações , Índice de Massa Corporal , Obesidade/complicações , Ambulatório Hospitalar , Magreza/complicações , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etnologia , Fibrilação Atrial/mortalidade , Eletrocardiografia , Feminino , Avaliação Geriátrica , Hospitais Universitários , Humanos , Japão , Estimativa de Kaplan-Meier , Masculino , Obesidade/diagnóstico , Obesidade/etnologia , Obesidade/mortalidade , Prognóstico , Fatores de Risco , Magreza/diagnóstico , Magreza/etnologia , Magreza/mortalidade
15.
J Interv Card Electrophysiol ; 66(4): 981-989, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36336724

RESUMO

BACKGROUND: The distal hemisphere of a balloon is generally cooled during cryoapplication. However, a wide ablation area can be acquired after cryoballoon ablation. This study aimed to evaluate the extent of ice formation on two types of balloon surfaces through experimental and simulation studies. METHODS: A standard cryoballoon (SCB; Arctic Front Advance Pro, Medtronic) and novel cryoballoon (NCB; POLARx, Boston Scientific) were frozen for 240 s in 36 °C normal saline solution to observe ice formation on the balloon surface. Pieces of porcine tissue were placed between the upper and lower sides of the balloon, and the balloon was frozen in the horizontal direction for 240 s in 20 attempts (10 for SCB and NCB each). The measured areas of ice formation were evaluated and compared between the upper and lower sides of each balloon. RESULTS: Ice formation was greater on the lower side of the balloon than on the upper side. A larger area of ice formation in the tissue slab was observed on the lower side than on the upper side in both balloons, and the ice formation extended to the proximal hemisphere on the lower side of the balloon. The ice formation area in the NCB was significantly larger than that in SCB. CONCLUSIONS: Ice formation was significantly greater on the lower side of the cryoballoon than on the upper side and extended to the proximal hemisphere of the balloon, which might facilitate the acquisition of a wide ablation area on the left atrial posterior wall after cryoballoon ablation. Different ice formation after cryoballoon ablation Greater ice formation on the lower side of cryoballoon and an extensive ice formation in the proximal hemisphere, especially in novel cryoballoon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Animais , Suínos , Gelo , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Resultado do Tratamento
16.
Clin Case Rep ; 10(12): e6791, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36578796

RESUMO

A 69-year-old man presented bradycardia with a constant blocked atrial bigeminy and heart failure. Successful catheter ablation of blocked atrial bigeminy with bradycardia resulted in myocardial reverse remodeling and restoration of the normal sinus rhythm from the ectopic atrial rhythm.

17.
BMJ Case Rep ; 14(10)2021 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-34706922

RESUMO

A 99-year-old woman with atrial fibrillation bradycardia and symptomatic long pauses underwent a leadless pacemaker implantation after red blood cell transfusion due to anaemia. The patient's blood tests after transfusion showed hypercoagulability; haematocrit, haemoglobin and fibrinogen levels were increased from 24.5% to 33.2%, 76 g/L to 111g/L, and 346 mg/dL to 646 mg/dL, respectively. Blood tests showed no hereditary hypercoagulability disorder and she had no history of thrombophilia. A leadless pacemaker was implanted in the correct position in the right ventricle. Heparin was administered after sheath insertion and the leadless pacemaker system was thoroughly flushed with heparinised saline before the tether was cut; however, removing the tether after leadless pacemaker implantation was difficult because clots had formed on the tether.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Idoso de 80 Anos ou mais , Fibrilação Atrial/terapia , Bradicardia/etiologia , Bradicardia/terapia , Estimulação Cardíaca Artificial , Feminino , Ventrículos do Coração , Humanos
18.
JACC Clin Electrophysiol ; 7(7): 843-854, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33640356

RESUMO

OBJECTIVES: This study sought to demonstrate a new type of verapamil-sensitive fascicular ventricular tachycardia (VT) with a reverse circuit. BACKGROUND: Left posterior fascicular ventricular tachycardia (LPFVT) is the most common form of verapamil-sensitive fascicular VT. Reverse-type LPFVT has not been reported. METHODS: We searched for a reverse-type LPFVT among 242 patients with verapamil-sensitive VT from February 2006 to September 2019. RESULTS: Three patients had a reverse-type LPFVT (cycle lengths: 340, 360, and 340 ms). QRS configuration during VT was narrow (140, 150, and 140 ms) and exhibited rSr' morphology in V1 with an early precordial transition and inferior axis. Two of 3 patients had common-type LPFVT. During reverse-type LPFVT, the earliest ventricular activation was the left superior middle septum. Fragmented Purkinje potentials (P1) buried within the local ventricular electrogram were recorded with an activation sequence from the apex to the base and were linked to the subsequent left ventricular septal activation. After radiofrequency catheter ablation at P1 during LPFVT, the reverse-type LPFVT also became noninducible. In 1 patient with only the reverse-type LPFVT, radiofrequency catheter ablation at the earliest LV activation site suppressed VT. These findings suggest that this new type of verapamil-sensitive fascicular VT shares a re-entrant circuit with a reverse direction of common LPFVT with an intramural exit site at the superior middle septum. CONCLUSIONS: Reverse-type LPFVT can occur. If common LPFVT exists, diastolic P1 during LPFVT can be a common target of ablation. If only reverse-LPFVT is inducible, the earliest ventricular activation site can be a target.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Eletrocardiografia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
19.
Cardiovasc Interv Ther ; 36(4): 514-522, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33128695

RESUMO

Low skeletal muscle mass is one of the components of sarcopenia. However, the prognostic impact of skeletal muscle mass on clinical outcomes in patients after transcatheter aortic valve replacement (TAVR) remains unclear. Therefore, we assessed the impact of skeletal muscle mass on future cardiovascular events in patients undergoing TAVR. We enrolled 71 consecutive patients who underwent TAVR for symptomatic severe aortic stenosis. We applied bilateral psoas muscles as an indicator of skeletal muscle mass. Psoas muscle volumes were measured from the origin of psoas at the level of the lumbar vertebrae to its insertion in the lesser trochanter on three-dimensional computed tomography datasets. Psoas muscle mass index (PMI) was calculated as psoas muscle volume/height2 (cm3/m2). According to the median value of PMIs (79.8 and 60.0 cm3/m2 for men and women), the enrolled patients were divided into two groups. During the follow-up, 11 (31.4%) patients in low PMI group and 4 (11.1%) in high PMI group experienced major adverse cardiovascular events (MACE) defined as a composite of death from any cause, myocardial infarction, heart failure hospitalization, and stroke. The proportion of MACE-free survival was significantly lower in low PMI group (log-rank P = 0.033), mainly due to the difference of hospital readmission for congestive heart failure. On multivariate Cox proportional hazard analysis, PMI remained an independent negative predictor of MACE [hazard ratio 0.95 (95% confidence interval 0.92-0.98, P = 0.002)]. In conclusion, low skeletal muscle mass independently predicted MACE in patients undergoing TAVR.


Assuntos
Estenose da Valva Aórtica , Sarcopenia , Substituição da Valva Aórtica Transcateter , Valva Aórtica , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Modelos de Riscos Proporcionais , Músculos Psoas/diagnóstico por imagem , Músculos Psoas/patologia , Estudos Retrospectivos , Fatores de Risco , Sarcopenia/patologia , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Clin Case Rep ; 8(12): 3248-3253, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33363914

RESUMO

A first-line cryoablation for para-Hisian VAs using a strict cryomapping protocol is useful and safe, even if the His bundle potential is recorded on the ablation catheter.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA