RESUMO
OBJECTIVE: Prepump arterial (Pa) pressure indicates the ease or difficulty with which the blood pump can draw blood from the vascular access (VA) during hemodialysis. Some studies have suggested that the absolute value of the Pa pressure to the extracorporeal blood pump flow (Qb) ratio set on the machine (|Pa/Qb|) can reflect the dysfunction of VA. This study was conducted to explore the impact of arteriovenous fistula (AVF) dysfunction and to explore the clinical reference value of |Pa/Qb|. METHODS: We retrospectively identified adults who underwent hemodialysis at 3 hospitals. Data were acquired from electronic health records. We evaluated the pattern of the association between |Pa/Qb| and AVF dysfunction during 1 year using a Cox proportional hazards regression model with restricted cubic splines. Then, the patients were grouped based on the results, and hazard ratios were compared for different intervals of |Pa/Qb|. RESULTS: A total of 490 patients were analyzed, with an average age of 55 (44, 66) years. There were a total of 85 cases of AVF dysfunction, of which 50 cases were stenosis and 35 cases were thrombosis. There was a U-shaped association between |Pa/Qb| and the risk of AVF dysfunction (p for nonlinearity <0.001). |Pa/Qb| values <0.30 and >0.52 increased the risk of AVF dysfunction. Compared with the group with a |Pa/Qb| value between 0.30 and 0.52, the groups with |Pa/Qb| <0.30 and |Pa/Qb| >0.52 had a 4.04-fold (p = 0.002) and 3.41-fold (p < 0.001) greater risk of AVF dysfunction, respectively. CONCLUSIONS: The appropriate range of |Pa/Qb| is between 0.30 and 0.52. When |Pa/Qb| is <0.30 or >0.52, the patient's AVF function or Qb setting should be reevaluated to prevent subsequent failure.
Assuntos
Pressão Arterial , Fístula Arteriovenosa/etiologia , Diálise Renal/efeitos adversos , Adulto , Idoso , Fístula Arteriovenosa/fisiopatologia , Fístula Arteriovenosa/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Risco , Fatores de RiscoRESUMO
BACKGROUND: Pulmonary hypertension (PH) is common in patients with end-stage renal disease (ESRD). Arteriovenous fistulas (AVF) creation may involve in the pathogenesis of PH. The aim of this study was to explore the impact of PH after AVF creation on the AVF failure rate in maintenance hemodialysis (MHD) patients. METHODS: From January 1, 2009, to January 1, 2019, we retrospectively collected data of 578 MHD patients in Guangdong Provincial People's Hospital Blood Purification Center, China. Patients were followed-up until AVF failure or death or May 25, 2020. According to the systolic pulmonary artery pressure (SPAP) within 1 year after the establishment of AVF, the MHD patients were divided into three groups: SPAP ⩽ 35 mmHg, 35 < SPAP < 45 mmHg, SPAP ⩾ 45 mmHg. The primary outcome was AVF failure defined as AVF cannot complete hemodialysis. The secondary outcomes were all-cause mortality. RESULTS: A total of 578 patients were analyzed. The average age was 60.66 ± 15.34 years (58.1% men). Of these, 26.1% of patients were reported PH. The SPAP exhibited a left-skewed nonparametric distribution and the overall SPAP after the creation of AVF was 39.00 (29.00-52.00) mmHg. The median follow-up was 5.8 (5.5-6.3) years. Overall, 12.8% (74/578) patients were reported AVF failure events. There was no significant difference in AVF failure rate among three groups (p = 0.070). A total of 111 (19.2%) died during the follow-up period. Compared with the SPAP ⩽35 mmHg group, only the all-cause death rate significantly increased in MHD patients with PH (p < 0.001). CONCLUSIONS: The secondary pulmonary hypertension after AVF creation did not increase the risk of AVF failure in MHD patients, but significantly increased the risk of mortality for this portion of the patients. Future larger sample sizes, multi-center, and prospective trials are needed to make sure which type of access will benefit on their survival for MHD patients with SPAP ⩾35 mmHg.
Assuntos
Derivação Arteriovenosa Cirúrgica , Hipertensão Pulmonar , Falência Renal Crônica , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/complicações , Seguimentos , Estudos Prospectivos , Estudos Retrospectivos , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Diálise Renal/efeitos adversos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Falência Renal Crônica/complicaçõesRESUMO
BACKGROUND: The important effect of regular blood flow surveillance on arteriovenous fistula maintenance is emphasized. The ultrasonic dilution technique for blood flow surveillance can be performed during hemodialysis, but there are some limitations. Blood flow is traditionally measured by duplex Doppler ultrasound during the nondialysis period. However, the surveillance workload for arteriovenous fistula has increased with the rapid increase in the hemodialysis population size. Efficient methods for blood flow surveillance during hemodialysis are needed. METHODS: Eighty-four hemodialysis patients with a forearm radiocephalic arteriovenous fistula were enrolled in this cross-sectional study. Each received blood flow measurements using ultrasonic dilution technique and duplex Doppler ultrasound during hemodialysis. Duplex Doppler ultrasound measurements included the blood flow of the brachial artery and radial artery. The correlations between these variables were analyzed. RESULTS: The correlation coefficients (r) between flow measured by ultrasonic dilution technique and brachial artery flow measured by duplex Doppler ultrasound, between flow measured by ultrasonic dilution technique and radial artery flow measured by duplex Doppler ultrasound, and between brachial artery flow and radial artery flow measured by duplex Doppler ultrasound were 0.724, 0.784, and 0.749, respectively (all p < 0.001). CONCLUSION: Blood flow measured by ultrasonic dilution technique was positively correlated with blood flow measured by duplex Doppler ultrasound during hemodialysis, suggesting that duplex Doppler ultrasound can be used to monitor the trends in the blood flow of the brachial artery and radial artery for timely intervention to improve patency during hemodialysis.
Assuntos
Derivação Arteriovenosa Cirúrgica , Artéria Braquial/cirurgia , Antebraço/irrigação sanguínea , Técnicas de Diluição do Indicador , Artéria Radial/cirurgia , Diálise Renal , Ultrassonografia Doppler em Cores , Grau de Desobstrução Vascular , Adulto , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Velocidade do Fluxo Sanguíneo , Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiopatologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Artéria Radial/diagnóstico por imagem , Artéria Radial/fisiopatologia , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Adulto JovemRESUMO
INTRODUCTION: Patients with arteriovenous fistulas are advised to avoid carrying heavy objects draped over the fistula arm. Awareness gradually leads to overprotection and a reduction in the use of the fistula arm. However, restricting motion in the fistula arm leads to decreased quality of life and diminished muscle strength. The current safety recommendations regarding lifting heavy items with the fistula arm are primarily based on experience. Few studies have provided evidence clarifying the scope of safe activity and the influence of load bearing on the continued patency of arteriovenous fistulas. METHODS: This prospective observation was based on a long-term follow-up study in which 86 hemodialysis recipients with arteriovenous fistulas were randomized into either a dumbbell group or a handgrip group. The dumbbell group exercised with 6-lb dumbbells, while the handgrip group squeezed rubber balls. Postintervention primary patency and adverse events at the 6-month follow-up were analyzed. RESULTS: No significant difference in postintervention primary patency was observed between the dumbbell group and the handgrip group at 6 months (97.4% vs 95.0%). There were two participants with high-flow fistulas in the dumbbell group and three in the handgrip group, with no significant difference between the two groups (5.3% vs 7.5%). In both groups, there were no other adverse events reported regarding cardiac failure, aneurysm, puncture site hematoma, or hemorrhage. CONCLUSION: Hemodialysis patients can safely use their fistula arm to lift objects weighing less than 6 lb, which encourages increased motion and helps preserve the functionality of the fistula arm.
Assuntos
Derivação Arteriovenosa Cirúrgica , Força da Mão , Remoção , Treinamento Resistido , Extremidade Superior/irrigação sanguínea , Adulto , Idoso , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Remoção/efeitos adversos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Diálise Renal , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
INTRODUCTION: Prepump arterial pressure (Pa) indicates the ease or difficulty with which the blood pump can draw blood from vascular access (inflow) during hemodialysis. The absolute prepump arterial pressure to blood pump speed (Qb) ratio (|Pa/Qb|) may reflect the dysfunction of other vascular accesses. There is no consensus on the impact of |Pa/Qb| on arteriovenous fistula dysfunction. This study aimed to demonstrate the impact of |Pa/Qb| on arteriovenous fistula dysfunction. METHODS: In this retrospective analysis, 490 hemodialysis patients with arteriovenous fistula from three hospitals were enrolled. Data were extracted from the I-Diapro database and hospital case systems. The absolute values for |Pa/Qb| and other data collected in the first month of enrollment were used to predict arteriovenous fistula dysfunction and determine the |Pa/Qb| cutoff value. Based on this value, patients were grouped, and 1-year arteriovenous fistula function was analyzed. Patients were followed until arteriovenous fistula dysfunction, until access type replacement, or for 12 months. RESULTS: The area under the receiver operating characteristic curve for fistula dysfunction over 1 year was 0.65, with an optimal |Pa/Qb| value, sensitivity, and specificity of 0.499, 60.7%, and 72.6%, respectively. |Pa/Qb| > 0.499 was associated with earlier intervention (317.37 ± 7.68 vs 345.96 ± 3.64 days), lower survival (p < 0.001), and a 3.26-fold greater risk of arteriovenous fistula dysfunction (p < 0.001) than |Pa/Qb| ⩽ 0.499. CONCLUSIONS: |Pa/Qb| was an independent risk factor for arteriovenous fistula dysfunction. Nurses should emphasize |Pa/Qb| monitoring and properly set blood pump speed according to this ratio to protect arteriovenous fistula function. |Pa/Qb| > 0.499 might be a predictive measure of arteriovenous fistula dysfunction.