J Appl Clin Med Phys ; 22(3): 273-278, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33638579

RESUMO

PURPOSE: To develop a method combining CT scout images with axial images to improve the localization accuracy of catheter tips in high-dose-rate (HDR) brachytherapy treatments. MATERIALS AND METHODS: CT scout images were utilized along with conventionally reconstructed axial images to aid the localization of catheter tips used during HDR treatment planning. A method was developed to take advantage of the finer image resolution of the scout images to more precisely identify the tip coordinates. The accuracies of this method were compared with the conventional method based on the axial CT images alone, for various slice thicknesses, in a computed tomography dose index (CTDI) head phantom. A clinical case which involved multiple interstitial catheters was also selected for the evaluation of this method. Locations of the catheter tips were reconstructed with the conventional CT-based method and this newly developed method, respectively. Location coordinates obtained via both methods were quantitatively compared. RESULTS: Combination of the scout and axial CT images improved the accuracy of identification and reconstruction of catheter tips along the longitudinal direction (i.e., head-to-foot direction, more or less parallel to the catheter tracks), compared to relying on the axial CT images alone. The degree of improvement was dependent on CT slice thickness. For the clinical patient case, the coordinate differences of the reconstructed catheter tips were 2.6 mm ± 0.9 mm in the head-to-foot direction, 0.4 mm ± 0.2 mm in the left-to-right direction, and 0.6 mm ± 0.2 mm in the anterior-to-posterior direction, respectively. CONCLUSION: Combining CT scout and axial images demonstrates the ability to provide a more accurate identification and reconstruction of the interstitial catheter tips for HDR brachytherapy treatment, especially in the longitudinal direction. The method developed in this work has the potential to be implemented clinically together with automatic segmentation in modern brachytherapy treatment planning systems, in order to improve the reconstruction accuracy of HDR catheters.


Assuntos
Braquiterapia , Catéteres , Humanos , Imageamento Tridimensional , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA