Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int Endod J ; 52(10): 1446-1456, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31034099

RESUMO

AIM: To evaluate bone tissue reactions in rats to an MTA-based endodontic sealer with and without the addition of various concentrations of C3A or C3A + Ag. METHODOLOGY: Bone tissue reactions were evaluated in 45 Wistar rats after 7, 30 and 90 days (n = 5 per period). Three surgical cavities were prepared on the right femur and filled with 0.2 mL MTA Fillapex, MTA Fillapex + C3A and C3A + Ag at various concentrations: AH Plus (Dentsply DeTrey GmbH, Konstanz, Germany), EndoSequence BC (Brasseler USA, Savannah, GA, USA) or no sealer (negative control). By the end of each experimental period, animals were randomly euthanized. The samples were histologically processed and analysed using a light microscope. The presence of inflammatory cells, fibres and hard tissue barrier formation was evaluated. Data were analysed statistically using nonparametric tests to compare the differences between groups. Multiple groups were compared using the Kruskal-Wallis and Mann-Whitney U-tests with a Bonferroni correction at P = 0.05. RESULTS: The inflammatory response significantly decreased from 30 to 90 days (P < 0.05). Fibre condensation was similar amongst the groups at 07 and 30 days after intervention (P > 0.05). At 90 days, however, fibres were absent in most specimens of EndoSequence BC Sealer, AH Plus, MTA Fillapex and the control group, whilst they were still observed in samples of the modified sealers (P < 0.05). At 90 days, all specimens of AH Plus, EndoSequence BC Sealer and control group had complete formation of hard tissue barrier. In the MTA Fillapex group, as well as in the modified sealers groups, partial deposition of mineralized tissue was noticed. CONCLUSION: The hypothesis tested that the incorporation of C3A and C3A + Ag particles to MTA Fillapex would improve bone tissue repair was partially accepted, since modified MTA Fillapex did not have the same repair potential as the commercial bioceramic material.


Assuntos
Materiais Restauradores do Canal Radicular , Prata , Compostos de Alumínio , Animais , Compostos de Cálcio , Combinação de Medicamentos , Resinas Epóxi , Alemanha , Teste de Materiais , Óxidos , Pemetrexede , Ratos , Ratos Wistar , Silicatos
2.
Int Endod J ; 50(8): 729-739, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27520405

RESUMO

AIM: To determine the prevalence of preoperative endodontic pain (PREP) and the incidence of postoperative endodontic pain (POEP), identifying the predictors of PREP and POEP in a southern Brazilian subpopulation, using clinical data from an electronic chart database (ECD). METHODOLOGY: This retrospective observational study included 563 consecutive individuals presenting for root canal treatment (RCT). Patients were treated by undergraduate and graduate students, following standard RCT protocols. Demographic, medical and dental variables were extracted from a pre-structured and standardized ECD. The main outcomes PREP and incident POEP were collected through a 0-10 numeric rating scale, dichotomized as none/mild (<4) or moderate/severe (≥4) pain. Predictive models calculating the prevalence ratios (PR) of PREP and the relative risks (RR) of incident POEP were carried out with Poisson regression analysis, estimating the relationship between clinical factors, PREP and incident POEP. RESULTS: Mean age at baseline was 49.2 ± 17.1 years, with 68.4% women. The prevalence and incidence of moderate/severe PREP and POEP were 44.4% and 3.8%, respectively. RCT intervention significantly reduced PREP (P < 0.001). Multivariate analysis revealed that group of teeth, location (mandibular teeth), pulpitis, necrotic pulp, preoperative swelling and periapical radiolucency were independently associated with moderate/severe PREP, whilst age ≥60 years and root canal retreatments were independent protective factors to PREP (P < 0.05). No demographic, medical or dental variables were associated with POEP, although molar teeth (RR = 4.23, 95%CI = 0.93-19.2, P = 0.056) had a borderline nonsignificant association. CONCLUSIONS: Moderate/severe PREP was independently associated with age, group of teeth, location, preoperative swelling, retreatments and pulp and periapical status. No demographic, medical or dental variable predicted moderate/severe POEP following RCT amongst this subpopulation.


Assuntos
Doenças da Polpa Dentária/fisiopatologia , Doenças da Polpa Dentária/cirurgia , Polpa Dentária/fisiopatologia , Dor Facial/etiologia , Dor Pós-Operatória/etiologia , Tratamento do Canal Radicular/efeitos adversos , Brasil/epidemiologia , Registros Eletrônicos de Saúde , Dor Facial/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/epidemiologia , Prevalência , Estudos Retrospectivos
3.
Int Endod J ; 47(6): 505-13, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23998507

RESUMO

AIM: To develop a method to evaluate the cutting behaviour of nickel-titanium (NiTi) coronal flaring instruments. METHODOLOGY: BioRaCe BR0 (BR), HyFlex CM 1 (HY), ProFile OS No. 2 (PF) and ProTaper Sx (PT) instruments were used in simulated coronal flaring using a lateral action against bovine dentine blocks, at 250 and 500 rpm. Cutting efficiency was assessed by three methods: first, areas of notches produced by instruments were directly measured under a stereomicroscope. Second, dentine specimens were then analysed by surface profilometry to determine the maximum cutting depth and finally by microcomputed tomography to assess the volume of removed dentine. Data were compared using parametric tests with the significance level set at 0.05. RESULTS: For all three methods, HY and PF were the most and the least cutting-efficient instruments, respectively (P < 0.05). Significant differences were detected between 250 and 500 rpm for HY and PT (area); for BR, HY and PT (depth); and for BR and HY (volume). There were strong positive correlations between the results obtained with those three different methods with r-values ranging from 0.81 to 0.92. CONCLUSION: Measuring the amount of material removed in a specific time under stereomicroscopy is a simple and rational way to assess the cutting behaviour of NiTi rotary instruments in lateral action. HyFlex, manufactured with thermomechanically treated NiTi wire, was the most efficient instrument, and increased rotational speed was associated with increased cutting efficiency.


Assuntos
Instrumentos Odontológicos , Endodontia/instrumentação , Níquel , Titânio , Animais , Bovinos , Microtomografia por Raio-X
4.
Int Endod J ; 44(12): 1128-33, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21895702

RESUMO

AIM: To evaluate the pH and antibacterial activity of Endo CPM Sealer and MTA Fillapex by two different methods, using white MTA and Endofill as references for comparison. METHODOLOGY: Antibacterial activity was evaluated against Enterococcus faecalis (ATCC 29212). The agar diffusion test (ADT) was performed to evaluate the effect before setting. The materials were placed in four equidistant wells made in ten agar plates. After incubation at 37 °C for 48 h, the inhibition zones were measured using a digital paquimeter. The direct contact test (DCT) was performed to assess the antibacterial effect after setting. Suspensions of crushed materials were prepared and mixed with E. faecalis. After different periods of time (1, 6, 15 and 60 min), the survival of bacteria was assessed by using 10-fold serial dilution and cultivated on agar plates in triplicate. Colony-forming units (CFU) mL(-1) were calculated after incubation. pH values were also measured in triplicate. Comparison between sealers in the ADT and DCT was performed by the Kruskal-Wallis test. RESULTS: In the ADT, inhibition zones were found with MTA Fillapex and Endofill. They were similar to each other and greater than the other sealers (P < 0.05). None of the tested sealers demonstrated antibacterial activity in the DCT, and thus, all sealers had similar bacterial counts compared with the negative control group (P > 0.05). White MTA and Endo CPM Sealer suspensions had pH values >11, whilst MTA Fillapex and Endofill had lower values. CONCLUSIONS: MTA Fillapex and Endofill had an antibacterial effect against E. faecalis before setting, but none of the sealers maintained antibacterial activity after setting, despite the high pH of the MTA-based materials.


Assuntos
Compostos de Alumínio/farmacologia , Antibacterianos/farmacologia , Compostos de Cálcio/farmacologia , Óxidos/farmacologia , Materiais Restauradores do Canal Radicular/farmacologia , Silicatos/farmacologia , Compostos de Alumínio/química , Antibacterianos/química , Carga Bacteriana/efeitos dos fármacos , Compostos de Cálcio/química , Combinação de Medicamentos , Enterococcus faecalis/efeitos dos fármacos , Humanos , Concentração de Íons de Hidrogênio , Imunodifusão , Teste de Materiais , Viabilidade Microbiana/efeitos dos fármacos , Óxidos/química , Transição de Fase , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Temperatura , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA