Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Br J Ophthalmol ; 81(10): 835-9, 1997 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9486022

RESUMO

AIMS: The aims of this study were to examine the influence of advanced recipient and donor age on the long term outcome of corneal transplantation. METHODS: Records of 1036 penetrating corneal grafts in recipients aged > or = 80 years at surgery (defined as the elderly subset) and 8092 donor corneas used for transplantation were obtained from the Australian Corneal Graft Register database, Kaplan-Meier graft survival plots were compared using log rank statistics. RESULTS: Elderly recipients constituted 15% of the recipient pool. The major indication for corneal transplantation in the elderly was bullous keratopathy. Graft survival fell with increasing recipient age (p < 0.00001); the major cause of graft failure was rejection (33%). The desired outcome in 51% of cases was to improve vision and in 42% of cases to relieve pain; 23% of elderly recipients achieved a Snellen acuity of 6/18 or better in the grafted eye and 66% recorded improved acuity after transplantation. Elderly recipients suffered more complications and comorbidities in the grafted eye than did younger recipients. Donor age (stratified in 10 year intervals) did not influence corneal graft survival significantly (p = 0.10). CONCLUSIONS: Elderly graft recipients fared less well after corneal transplantation than did younger recipients, but outcomes in terms of long term graft survival and visual rehabilitation were still good. Donor age did not affect graft survival.


Assuntos
Transplante de Córnea , Sobrevivência de Enxerto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Humanos , Sistema de Registros , Resultado do Tratamento , Acuidade Visual
6.
Ophthalmology ; 99(3): 403-14, 1992 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-1565452

RESUMO

Risk factors for graft failure after penetrating keratoplasty were investigated in 961 patients from records collected prospectively by the Australian Corneal Graft Registry. The most common cause of graft failure was irreversible rejection. A multivariate proportional hazards regression analysis indicated that the key predictors of graft failure were: an indication for graft other than keratoconus or corneal dystrophy; a failed previous graft (ipsilateral eye); aphakia; inflammation at the time of graft; presence of an anterior chamber or iris-clip intraocular lens; graft size outside the range of 7.0 to 7.9 mm diameter; and corneal vascularization occurring in the postoperative period.


Assuntos
Transplante de Córnea/estatística & dados numéricos , Sobrevivência de Enxerto , Ceratoplastia Penetrante , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália/epidemiologia , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Ceratoplastia Penetrante/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Fatores de Risco , Doadores de Tecidos
7.
Eye (Lond) ; 9 ( Pt 2): 219-27, 1995.
Artigo em Inglês | MEDLINE | ID: mdl-7556721

RESUMO

Corneal graft outcome was assessed within a large, prospectively collected database of 4499 records. Penetrating corneal graft survival was 91% at 1 year, 72% at 5 years and 69% at 7 years. The three most common indications for graft were keratoconus (30%), bullous keratopathy (25%) and failed previous graft (18%); the three most common causes of graft failure were rejection (34%), infection (18%) and glaucoma (9%). The vast majority of grafts were performed for improved visual acuity. About four-fifths of recipients achieved at least one line of better acuity on the Snellen chart post-operatively; of the remainder with unchanged or worse acuity, only 21% had failed grafts. Overall, 43% of recipients achieved a best corrected Snellen acuity of 6/12 or better, 52% achieved 6/18 or better, and 20% had acuitities of less than 6/60. Reasons for poor post-operative acuity (recorded as less than 6/60) included graft failure (41%) and comorbidities in the grafted eye (43%). A number of risk factors for graft failure were examined: in most instances, there was little room for decision-making or expert intervention.


Assuntos
Transplante de Córnea , Sobrevivência de Enxerto , Astigmatismo/cirurgia , Austrália , Transplante de Córnea/estatística & dados numéricos , Humanos , Ceratocone/cirurgia , Lentes Intraoculares , Hipertensão Ocular/complicações , Complicações Pós-Operatórias , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Acuidade Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA