Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Ophthalmic Physiol Opt ; 44(1): 32-41, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37994563

RESUMO

PURPOSE: To identify the stimulus airflow characteristics and confirm the consistency of a novel air jet-based aesthesiometer capable of producing and applying multiple stimuli separated either by time and/or by space. METHODS: A novel aesthesiometer (Dolphin Aesthesiometer) was designed around a micro-blower under software management. Two nozzle attachments assisted in airflow control (flexible tube 1.6 mm diameter; brass tube 0.5 mm diameter). Four studies that tested the characteristics of the airflow and stimulus consistency were completed: (i) airflow pattern/trajectory, (ii) airflow surface dispersion, (iii) force of airflow across a range of stimulus strengths and (iv) thermal effects on the ocular surface. RESULTS: Stimulus characteristic studies revealed: (i) airflow is coherent within the expected test distance range for the instrument, and spread rate is constant irrespective of stimulus strength; (ii) airflow dispersion occurs upon encountering a surface and dispersion increases with increasing airflow rate; (iii) a consistent and small force (10-4 N) is applied by the airflow and (iv) repeatable thermal effects occur in relation to the airflow, and the mode of stimulation of the Dolphin aesthesiometer is predominantly thermal in nature. CONCLUSIONS: These studies confirm the repeatability and consistency of the novel instrument. The device is suitable for measuring corneal sensitivity. The availability of additional air jets allows the application of multiple stimuli to facilitate corneal summation investigations.


Assuntos
Córnea , Golfinhos , Animais
2.
J Interprof Care ; 37(4): 674-688, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36153712

RESUMO

Daily surgical ward rounds shape the quality of postoperative care and contribute to positive patient outcomes. Despite their importance, strategies to facilitate and promote deliberate interdisciplinary collaboration within surgical ward rounds have not been comprehensively investigated. This paper systematically reviews the literature to identify what is known from existing publications about interdisciplinary working on surgical ward rounds. Pubmed, Embase, CINAHL, Scopus, and Web of Science were searched from database inception until May 2021 for studies involving interdisciplinary surgical ward rounds. Also, journal hand searches were undertaken. All potential abstracts and papers were screened independently by two reviewers to determine inclusion. All included papers were assessed for methodological quality using the accepted quality criteria outlined in the BEME No. 1 guide. A modified Kirkpatrick model was employed to analyze and synthesize the included studies. The search identified 1765 studies. Reviews of 861 abstracts resulted in the retrieval of 124 articles for full-text screening. Thirty-two papers met the inclusion/exclusion criteria. The levels of research evidence were low with 11 papers scoring either grade 4 (results are clear and very likely to be true) or grade 5 (results are unequivocal) in accordance with the BEME No. 1 guide. These 11 studies had three foci (1) full teams managing specific medical conditions through deliberate interdisciplinary collaboration on ward rounds (n = 5); (2) suggestions on the best format for interdisciplinary collaboration on ward rounds (n = 3); and, (3) the roles of specific disciplines in a collaborative surgical round (n = 3). Physicians, intensivists, and pediatricians embrace the benefits of interdisciplinary working to facilitate the improvement of communication, collaboration, and patient safety. Yet, persistent hierarchies within surgical wards act as a barrier often preventing allied health professionals from speaking up, thus perpetuating intra disciplinary siloed behaviors. This barrier contributes to a dearth of research evidence to facilitate interdisciplinary collaborative intentionality in surgical ward rounds and surgical education. Given the high-risk nature of surgery, interdisciplinary collaboration is a critical component for patient safety. Our findings serve as a call to action to address the rhetoric of interdisciplinary collaboration on surgical ward rounds. An evidence-base is required to design, educate for and implement interdisciplinary collaborative opportunities in surgical wards so this critical aspect of patient care becomes a reality.


Assuntos
Médicos , Visitas de Preceptoria , Humanos , Relações Interprofissionais
3.
Health Expect ; 25(6): 2680-2699, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36217557

RESUMO

BACKGROUND: Patient and Public Involvement (PPI) in research aims to improve the quality, relevance and appropriateness of research. PPI has an established role in clinical research where there is evidence of benefit, and where policymakers and funders place continued emphasis on its inclusion. However, for preclinical research, PPI has not yet achieved the same level of integration. As more researchers, including our team, aim to include PPI in preclinical research, the development of an evidence-based approach is important. Therefore, this scoping review aimed to identify and map studies where PPI has been used in preclinical research and develop principles that can be applied in other projects. METHODS: A scoping review was conducted to search the literature in Medline (PubMed), EMBASE, CINAHL, PsycInfo and Web of Science Core Collection to identify applied examples of preclinical PPI. Two independent reviewers conducted study selection and data extraction separately. Data were extracted relating to PPI in terms of (i) rationale and aims, (ii) approach used, (iii) benefits and challenges, (iv) impact and evaluation and (v) learning opportunities for preclinical PPI. Findings were reviewed collaboratively by PPI contributors and the research team to identify principles that could be applied to other projects. RESULTS: Nine studies were included in the final review with the majority of included studies reporting PPI to improve the relevance of their research, using approaches such as PPI advisory panels and workshops. Researchers report several benefits and challenges, although evidence of formal evaluation is limited. CONCLUSION: Although currently there are few examples of preclinical research studies reporting empirical PPI activity, their findings may support those aiming to use PPI in preclinical research. Through collaborative analysis of the scoping review findings, several principles were developed that may be useful for other preclinical researchers. PATIENT OR PUBLIC CONTRIBUTION: This study was conducted as part of a broader project aiming to develop an evidence base for preclinical PPI that draws on a 5-year preclinical research programme focused on the development of advanced biomaterials for spinal cord repair as a case study. A PPI Advisory Panel comprising seriously injured rugby players, clinicians, preclinical researchers and PPI facilitators collaborated as co-authors on the conceptualization, execution and writing of this review, including refining the findings into the set of principles reported here.


Assuntos
Participação do Paciente , Pesquisadores , Humanos
4.
Med Teach ; 44(1): 3-18, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34666584

RESUMO

INTRODUCTION: Little is known of processes by which feedback affects learners to influence achievement. This review maps what is known of how learners interact with feedback, to better understand how feedback affects learning strategies, and to explore enhancing and inhibiting factors. METHODS: Pilot searching indicated a wide range of interpretations of feedback and study designs, prompting the use of scoping methodology. Inclusion criteria comprised: (i) learners (undergraduate, postgraduate, continuing education) who regularly receive feedback, and (ii) studies that associated feedback with subsequent learner reaction. The screening was performed independently in duplicate. Data extraction and synthesis occurred via an iterative consensus approach. Self-regulatory learning theory (SRL) was used as the conceptual framework. RESULTS: Of 4253 abstracts reviewed, 232 were included in the final synthesis. Understandings of feedback are diverse; a minority adopt recognised definitions. Distinct learner responses to feedback can be categorized as cognitive, behavioural, affective, and contextual with complex, overlapping interactions. Importantly emotional responses are commonplace; factors mediating them are pivotal in learner recipience. CONCLUSION: Feedback benefits learners most when focussed on learner needs, via engagement in bi-directional dialogue. Learner emotions must be supported, with the construction of positive learner-teacher relationships. A developmental agenda is key to learner's acceptance of feedback and enhancing future learning.


Assuntos
Estudantes de Medicina , Retroalimentação , Humanos , Aprendizagem , Estudantes de Medicina/psicologia
5.
Optom Vis Sci ; 98(2): 143-149, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33534382

RESUMO

SIGNIFICANCE: Cytokine and protease analysis revealed relative changes in the post-lens tear film of scleral lenses with low and high limbal clearances. Results from this study indicate that midperipheral lens fit is an important fitting feature that can impact the inflammatory response of a keratoconic eye. PURPOSE: The purpose of this study was to investigate changes in levels of inflammatory mediators in the post-lens tear film of keratoconic scleral lens wearers with varying limbal clearance designs. METHODS: Twenty-two keratoconic eyes were fitted with two sets of scleral lenses that were consistent in lens diameter and central sagittal depth but varied in limbal clearance by approximately 50 µm. Lenses were worn in a randomly assigned order for a 2-week period each. At each follow-up visit, immediately after lens removal, tear samples were collected with a microcapillary tube (10 µL, 0.5 mm in diameter) from the bowl of the inverted scleral lens. Tear cytokine and protease analysis was performed using a multiplex electrochemiluminescent array (Meso Scale Discovery, Rockville, MD) instrument. Levels of interleukins 1, 6, and 8; tumor necrosis factor α; and matrix metalloproteinases 1 and 9 were compared and analyzed. RESULTS: Levels of interleukin 1ß, tumor necrosis factor α, and matrix metalloproteinase 1 increased with high limbal clearance (P = .01, .006, and .02, respectively). No change in interleukins 6 and 8 levels was found (P > .05). A decrease in matrix metalloproteinase 9 was noted in post-lens tear film of scleral lenses with high limbal clearance (P = .10). DISCUSSION: Relative changes in the cytokine and protease levels were found when comparing low and high limbal clearance, indicating that the midperipheral lens fit is an important feature that can impact the inflammatory response of the keratoconic eye.


Assuntos
Lentes de Contato , Citocinas/metabolismo , Proteínas do Olho/metabolismo , Ceratocone/terapia , Limbo da Córnea/fisiologia , Peptídeo Hidrolases/metabolismo , Lágrimas/metabolismo , Adulto , Humanos , Ceratocone/metabolismo , Masculino , Pessoa de Meia-Idade , Esclera
6.
Optom Vis Sci ; 97(9): 703-710, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32976323

RESUMO

SIGNIFICANCE: This study evaluates how limbal clearance (LC) may impact the clinical performance of scleral lenses based on subjective response on comfort and ocular responses. Limbal zone designs in scleral lenses might affect the integrity of the limbal epithelial tissue as a result of a combined hypoxic and compression-related etiology. PURPOSE: This study aimed to investigate the clinical performance and ocular and subjective responses to the wear of scleral lenses having varying LC. METHODS: Lenses with varying LC with a difference of 50 µm were fitted on and compared among keratoconic participants. The lenses were worn during a 2-week period. Visual analog scales concerning subjective comfort were completed. Ocular surface findings including hyperemia, limbal staining, and corneal swelling were compared. RESULTS: Participants reported greater comfort achieved with high LC. No difference in limbal and bulbar hyperemia was found (P > .05). Corneal response to scleral lens wear with both low and high LCs seems to result in similar perilimbal staining and negative corneal staining. An increase in corneal pachymetric values was noted at the central and peripheral cornea, with no difference between low- and high-LC lenses (all, P < .05). Quadrant-specific analysis indicated that all meridians at both 6 and 8 mm were increased for the low-LC lenses (all, P < .05) and only the temporal region for the high-LC lenses (P = .02). CONCLUSIONS: Limbal clearance may play an important role in subjective performance in scleral lenses but does not impact the degree of hyperemia in either the limbal or bulbar region. Although low LC might result in more compression-related changes to ocular surface, high LC is associated with greater comfort and greater edematous changes. Limbal zone designs in scleral lenses might affect the integrity of the limbal epithelial tissue as a result of a combined hypoxic and compression-related etiology.


Assuntos
Lentes de Contato , Ceratocone/terapia , Limbo da Córnea/anatomia & histologia , Esclera , Adulto , Idoso , Córnea/fisiopatologia , Edema da Córnea/fisiopatologia , Feminino , Humanos , Hiperemia/fisiopatologia , Ceratocone/fisiopatologia , Masculino , Pessoa de Meia-Idade , Ajuste de Prótese , Inquéritos e Questionários , Acuidade Visual/fisiologia , Adulto Jovem
7.
Eye Contact Lens ; 45(1): 55-60, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29505434

RESUMO

OBJECTIVES: To assess the efficacy and effect on clinical signs of a polyvinylsiloxane (Tresident; Shütz Dental Group GmbH, Germany) compared with an irreversible hydrocolloid (Orthoprint; Zhermack SpA, Badia Polesine, Italy) for ocular impression-taking. METHODS: Twenty subjects were recruited (13 female and 7 male), with mean age 31.1±4.6 years (SD) (range 25.8-39.7). Subjects attended for 2 sessions, each of 1-hr duration, on 2 separate days. Each session was scheduled at the same time on each day. At each visit, the subject underwent an ocular impression procedure, using either Tresident or Orthoprint, in random order and to one eye only. Investigator 2 was blind to this assignment. Two experienced practitioners conducted the study, investigator 1 performed the ocular impression procedures and investigator 2 observed and assessed the clinical signs: logMAR visual acuity, ocular surface staining, tear break-up time (TBUT), and ocular hyperemia. RESULTS: Visual acuity was unaffected by either material; TBUT was marginally disrupted by both materials, but was not clinically significant according to published criteria; ocular redness increased with both materials; and corneal staining was significantly greater after Orthoprint impression. Less redness and clinically insignificant staining after impression-taking, with fewer clinical complications, was found after use of Tresident. CONCLUSIONS: Tresident offers a quicker, more effective, and clinically viable method of obtaining ocular impression topography compared with the traditional Orthoprint, and Orthoprint causes significantly more superficial punctuate staining of the corneal epithelium than Tresident.


Assuntos
Coloides/análise , Túnica Conjuntiva/química , Doenças da Túnica Conjuntiva/diagnóstico , Córnea/metabolismo , Elastômeros/análise , Polivinil/análise , Siloxanas/análise , Coloração e Rotulagem/métodos , Lágrimas/química , Adulto , Túnica Conjuntiva/patologia , Doenças da Túnica Conjuntiva/metabolismo , Córnea/patologia , Feminino , Seguimentos , Humanos , Masculino , Método Simples-Cego
8.
Eye Contact Lens ; 45(4): 226-237, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30095530

RESUMO

The cornea is densely innervated with free nerve endings to provide a high level of sensitivity to foreign bodies or noxious substances. They also provide trophic support to the tissues of the cornea and facilitate their repair and replacement. Any reduction in the function of the nerve endings through disease, contact lens wear, or surgery may lead to corneal disease, damage, or reduced healing. Assessment of the corneal nerve function can be made by the use of specialized instruments (aesthesiometers) that stimulate the corneal nerves using different modalities-mechanical, chemical, and thermal. Each modality assesses the function of a different cohort of corneal nerve type. Ocular surgery, particularly corneal surgery, can produce significant damage to the corneal innervation. However, for the majority of surgical procedures, corneal sensation eventually returns to preoperative levels, given enough time. The principal exceptions to this are penetrating keratoplasty, epikeratophakia, and cryo-keratomileusis, where sensation rarely returns to normal. For all types of surgery, the pattern of corneal sensation loss and recovery depends on the type, depth, and extent of incision because these influence the number of nerve fibers severed, and on the healing response of the patient.


Assuntos
Córnea/fisiologia , Córnea/cirurgia , Nervo Oftálmico/fisiologia , Procedimentos Cirúrgicos Refrativos , Sensação/fisiologia , Fenômenos Biomecânicos , Córnea/inervação , Técnicas de Diagnóstico Oftalmológico , Humanos , Cicatrização/fisiologia
9.
Eye Contact Lens ; 44 Suppl 2: S70-S75, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28945647

RESUMO

OBJECTIVES: To investigate the ocular tear film in controlled and uncontrolled diabetes mellitus (DM) subjects and the relationship between dry eye and diabetes. METHODS: One hundred twenty-four diabetes adults (65 male and 59 female, with 62 controlled and 62 uncontrolled DM) were assessed by McMonnies dry eye questionnaire, tear break-up time (TBUT), phenol red thread (PRT) test. In addition, tear samples were collected from the lower tear meniscus of right eyes and dried onto glass slides under controlled room temperature (25°C) and humidity (40%). The glass slides were observed using a digital microscopy and the tear ferning (TF) patterns observed were graded based on Masmali TF grading scale. Patients with a HbA1c value below 6.5% were defined as "controlled DM" and those with a HbA1c value above 6.5% were defined as "uncontrolled DM." The Spearman's correlation coefficient was used to determine the relationship between various tests. RESULTS: Several subjects having dry eye varied depending on the test used. McMonnies questionnaire scores suggested that 28 subjects (23%) showed dry eye (score >14.5), of whom 23 subjects (82%) showed uncontrolled diabetes. The TF patterns showed that 44 subjects (35.5%) showed dry eyes (Grade ≥2), of whom 32 subjects (72.7%) showed uncontrolled diabetes. Phenol red thread test found that 46 subjects (37%) showed dry eye (wetting <10 mm), of whom 38 subjects (82.6%) showed uncontrolled diabetes. Tear break-up time found that 57 subjects (46%) showed dry eye (time <10 sec), of whom 45 subjects (78.9%) showed uncontrolled diabetes. In controlled diabetic subjects, TF grades showed medium negative correlations with both TBUT and PRT (-0.374 and -0.349, respectively). In uncontrolled subjects, TF grades have a strong negative correlation with TBUT (-0.539) and a medium negative correlation with PRT (-0.410). CONCLUSIONS: Dry eye disease is common in diabetic subjects, particularly in people with poor diabetic control. Uncontrolled blood glucose level seemed to be a risk factor for dry eye syndrome. Tear ferning test showed a correlation between diabetes and dry eye in diabetic subjects and can be used as a reliable test to evaluate the quality of the ocular tear film.


Assuntos
Diabetes Mellitus , Síndromes do Olho Seco/complicações , Síndromes do Olho Seco/fisiopatologia , Lágrimas/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Síndromes do Olho Seco/etiologia , Feminino , Hemoglobinas Glicadas/análise , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
10.
Optom Vis Sci ; 94(6): 688-693, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28538336

RESUMO

PURPOSE: Modern offices and the use of electronic devices are increasing factors in work-related eye symptoms. However, symptoms of eye fatigue or dry eye sensation can be mixed and confusing. This study surveys the eye symptoms reported during a working day at modern offices to investigate the possible inhibition on daily work activities. METHODS: Two online digital surveys were sent to three different work locations, by direct e-mail. Survey A consisted of 14 questions that investigated eye symptoms experienced during daily activities at work and the impact on daily activities. Survey B consisted of four general questions, the Dutch Ocular Surface Disease Index, the Work Productivity and Activity Index, and the Illness Perception Questionnaire. RESULTS: A total of 505 participants completed survey A, and 213 completed survey B. The participants reported that a high proportion of their day was spent working on a computer (60%). The majority experienced an air draft (79.1%) and had no adjustable light (81.5%) at their workspace. Dry eye-related symptoms were reported at a significantly higher frequency at work than at home (P < .001). Up to 70% experienced some inhibition of daily activity at work due to eye symptoms, with more than 5% experiencing symptoms most or all of the time. Indoor environment, work environment, and general health were perceived as the main reasons for developing dry eye. Compared with males, females showed a statistically significant higher Ocular Surface Disease Index score (P < .001) and experienced more inhibition and adverse effects on daily life and work productivity. CONCLUSIONS: This investigation shows that dry eye symptoms have a negative impact on daily activities at work. These findings suggest that multidisciplinary understanding of the negative impact of dry eye by a range of specialists will be of help in managing work-related dry eye.


Assuntos
Atividades Cotidianas , Síndromes do Olho Seco/fisiopatologia , Síndromes do Olho Seco/psicologia , Exposição Ocupacional , Adulto , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/fisiopatologia , Doenças Profissionais/psicologia , Inquéritos e Questionários
11.
Eye Contact Lens ; 41(5): 262-7, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25603440

RESUMO

OBJECTIVES: To investigate tear ferning (TF) test repeatability between sessions by observing changes in the tear fern pattern during the day. METHODS: Twenty-three healthy young adults (15 men and 8 women), ranging in age from 20 to 32 years (mean ± SD: 22.9 ± 3.3 years) without signs or symptoms of dry eye disease, ocular disease, or contact lens wear were enrolled in the study. Schirmer I, tear break-up time (TBUT) test, and McMonnies questionnaire were used to screen volunteers. Schirmer I and TBUT tests were applied to both eyes in each subject. Four samples of tear fluid were collected from the right eye of each subject using glass capillaries at set intervals during a single day (9 AM, 11 AM, 2 PM, and 4 PM). The TF patterns obtained from samples were classified according to the Masmali TF grading scale to increments of 0.1. RESULTS: The median values obtained from the McMonnies, Schirmer, and TBUT tests were 4.0 ± 2.0, 30.0 ± 7.0 mm (OD), and 16.0 ± 10.0 sec (OD), respectively. There were no statistically significant differences between the TF grades for tear samples collected at different times of the day (Wilks' Lambda, P = 0.351). The majority (84.8%) of TF grades was between 0.0 and 1.5; the remaining 15.2% of subjects had TF between grades 1.6 and 1.9. The overall mean grade for the TF was 1.1 ± 0.3. There were small insignificant correlations between TF grades and the McMonnies questionnaire (r = 0.1.30) and TBUT (r = 0.248) and a negligible correlation with Schirmer test (r = -0.046). CONCLUSIONS: The results found no significant differences within the TF for tear samples collected at different times of the day, suggesting that there is little diurnal variation evident.


Assuntos
Ritmo Circadiano/fisiologia , Lágrimas/fisiologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
12.
Optom Vis Sci ; 91(9): 1037-44, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25062132

RESUMO

PURPOSE: To investigate the capability of a new portable digital meniscometer (PDM) to measure tear meniscus radius (TMR) and tear meniscus height (TMH) at different locations along the lower lid and to evaluate relationships between tear meniscus regularity and the degree of lid-parallel conjunctival folds (LIPCOFs). METHODS: Using the PDM, the TMR and TMH of 42 subjects were measured at three locations along the lower lid of one eye: central, perpendicularly below the pupil center (TMR-C, TMH-C), and temporal (TMR-T, TMH-T) and nasal (TMR-N, TMH-N), perpendicularly below the limbus. Nasal and temporal LIPCOF grades were recorded. Correlations between the measurements were analyzed using the Pearson coefficient (or Spearman rank in nonparametric data), and the differences were evaluated by paired t tests or analysis of variance and post hoc Fisher least significant difference test. RESULTS: Temporal TMR was 0.041 mm flatter (p = 0.002) and TMH-T was 0.063 mm higher (p < 0.001), whereas TMR-N was 0.026 mm flatter (p = 0.038) and TMH-N was 0.046 mm higher (p < 0.001) than TMR-C and TMH-C. Temporal LIPCOF grades were significantly correlated to temporal alterations in TMH (r = 0.590; p < 0.001) and TMR (r = 0.530; p < 0.001), and nasal LIPCOF grades were significantly correlated to nasal alterations in TMH (r = 0.492; p = 0.001) and TMR (r = 0.350; p = 0.023). CONCLUSIONS: The PDM is able to noninvasively detect significant differences in TMR and TMH along the lower lid. The flatter TMR and higher TMH at the nasal and temporal locations are associated with increased LIPCOF. Because increased LIPCOF scores may affect tear film disruption along the lower lid, measuring TMR and TMH at the central position below the pupil may provide the best intersubject reliability.


Assuntos
Doenças da Túnica Conjuntiva/diagnóstico , Técnicas de Diagnóstico Oftalmológico/instrumentação , Pálpebras/química , Lágrimas/química , Adulto , Idoso , Síndromes do Olho Seco/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Inquéritos e Questionários , Tomografia de Coerência Óptica , Adulto Jovem
13.
Optom Vis Sci ; 91(1): e1-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24162893

RESUMO

PURPOSE: The aims of this study were (i) to develop a new portable slit-lamp mounted digital meniscometer (PDM) and (ii) to test its accuracy and repeatability compared to the existing Yokoi et al. videomeniscometer (VM). METHODS: We developed a novel application for an iPod or iPhone, which created an illuminated target of parallel black and white bands. This was used as a portable device with which to perform reflective meniscometry. The medians of three consecutive measurements on five glass capillaries (internal radii, 0.100 to 0.505 mm) were compared between VM and PDM at two different sessions. Also, the central lower tear meniscus radius (TMR) in 20 normal subjects (10 males and 10 females; mean [SD] age, 32.3 [9.3] years) was measured using both techniques. Correlations between the instruments were analyzed using the Pearson coefficient. Differences between sessions and instruments were analyzed using Bland-Altman plots, coefficient of repeatability, and paired t-tests. RESULTS: The PDM and VM were accurate in vitro (95% confidence interval [CI] of difference: PDM -0.0134 to +0.0074 mm, p = 0.468; VM -0.0282 to + 0.0226 mm; p = 0.775) and reproducible between sessions (95% coefficient of repeatability, 0.019 and 0.018, respectively). The mean difference between the PDM and VM in vitro was 0.0002 mm (95% CI, -0.0252 to + 0.0256; p = 0.984). In human subjects, mean (SD) TMR measured with the PDM (0.34 [0.10] mm) and VM (0.36 [0.11] mm) was significantly correlated (r = 0.940; p < 0.001), and there was no statistically significant difference between the measured TMR of the instruments (p = 0.124). CONCLUSIONS: This new slit-lamp mounted digital meniscometer produces accurate and reliable measurements and provides similar values for tear meniscus radius, in human studies, to the existing VM. The instrument is suitable for use in both research and clinical practice.


Assuntos
Síndromes do Olho Seco/diagnóstico , Optometria/instrumentação , Lágrimas/química , Testes Visuais/instrumentação , Adulto , Intervalos de Confiança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
14.
Ophthalmology ; 120(5): 1086-91, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23399377

RESUMO

PURPOSE: To investigate whether the central portions of the upper and lower eyelid margins make complete contact during spontaneous blinks. DESIGN: A prospective case series of subjects located in Weinheim, Germany. PARTICIPANTS: Data were analyzed from 30 subjects (14 women; mean age, 42.4 ± 12.3 years). METHODS: A small drop of lissamine green (LG; 0.15 µl) was placed on the keratinized portion of the central lower lid. Spontaneous blinks were recorded by video from a frontal view and simultaneously from a temporal-inferior view (high-speed video). Blinks were analyzed as being complete or incomplete, and the number of blinks necessary to remove the LG was counted. The upper eyelid was observed to grade the extent of misalignment of the lids in the z-axis. This so-called overblinking of the lids was classified using a 5-grade scale (0 = aligned; 1 = less than one-third overblink; 2 = more than one-third to two-thirds overblink; 3 = more than two-thirds to three-thirds overblink; and 4 = more than three-thirds overblink). Correlations were calculated by Pearson correlation (or Spearman rank in nonparametric data), and differences between groups were calculated by unpaired t test (or Mann-Whitney U test in nonparametric data). MAIN OUTCOME MEASURES: Contact between lids in spontaneous blinks and lid alignment. RESULTS: Mean blink rate was 14.9 ± 14.1 blinks/minute, and 58.8 ± 22.6% of blinks were incomplete. Blink rate was significantly higher in women than in men (P = 0.007, unpaired t test; female, 22.0 ± 16.8 blinks/minute; male, 8.6 ± 7.2 blinks/minute). Incomplete blinking occurred significantly less often in women (51.2 ± 18.5%) than in men (67.4 ± 24.5%; P = 0.029) but was not related to age (Pearson r = 0.108; P = 0.285). Lissamine green stayed unaltered in spontaneous blinks and, on average, 1.5 ± 0.8 forced blinks were needed to remove the LG. Mean grade of upper lid overblink was 3.0 ± 0.9. Lid overblink was correlated significantly with age (r = 0.456; P = 0.006). CONCLUSIONS: Central lid margins do not touch in spontaneous blinks because the lids are not aligned. FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.


Assuntos
Piscadela/fisiologia , Pálpebras/fisiologia , Adulto , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tempo de Reação/fisiologia , Gravação de Videoteipe
15.
Optom Vis Sci ; 90(10): 1034-9, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24067407

RESUMO

PURPOSE: To investigate the relationship between blink action, dry eye symptoms, and lid-parallel conjunctival folds (LIPCOF). METHODS: In 30 subjects (14 were women; mean [standard deviation {SD}] age, 42.4 [±12.3] years), spontaneous blinks were recorded from a temporal-inferior view (high-speed video), and the blink extent (incomplete [IC], almost complete [AC], and complete [CC]) was evaluated. Dry eye symptoms were evaluated using the Ocular Surface Disease Index (OSDI), and nasal and temporal LIPCOF grades were noted. Correlations between groups were calculated with Pearson correlation (or Spearman rank in nonparametric data), and differences between groups were calculated with an unpaired t-test (or U-test Mann-Whitney in nonparametric data). RESULTS: Blink rate was significantly higher in females (22.0% [±16.8]) than in males (8.6% [±7.2]; unpaired t-test: p = 0.007). The percentage of AC of all blinks (AC%) was significantly correlated to LIPCOF sum (nasal + temporal) and OSDI scores (r > 0.570, p < 0.001). The percentage of IC was significantly correlated to LIPCOF sum (r = -0.541, p < 0.001) but not to OSDI. CONCLUSIONS: The frequency and type of blinking may have an effect on dry eye symptoms and LIPCOF severity since almost all complete blinks were significantly related to both factors.


Assuntos
Piscadela/fisiologia , Doenças da Túnica Conjuntiva/fisiopatologia , Síndromes do Olho Seco/fisiopatologia , Adulto , Feminino , Humanos , Masculino , Inquéritos e Questionários , Gravação em Vídeo
16.
Cont Lens Anterior Eye ; 46(2): 101809, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36621341

RESUMO

Tear evaporation is a normal physiological phenomenon that has an important role in regulating blink activity and tear production. An altered tear evaporation rate (TER) is a defining characteristic of evaporative dry eye disease (DED), and the measurement of tear evaporation is a useful clinical test for diagnosis. Reported values for a normal TER cover a broad range, which may be due to the influence of ocular, environmental, and systemic factors. For improved disease diagnosis, a fuller understanding of the normal TER range is essential. This paper reports on a literature review of the current knowledge of these normal influences on TER.


Assuntos
Síndromes do Olho Seco , Humanos , Síndromes do Olho Seco/diagnóstico , Lágrimas/fisiologia , Piscadela , Concentração Osmolar
17.
Clin Exp Optom ; 106(5): 476-483, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-35614035

RESUMO

CLINICAL RELEVANCE: Inter-instrument variation in anterior corneal shape (ACS) measurement has a consequence for ocular clinical practice. BACKGROUND: To consider inter-instrument variability in keratometry measurements across the ACS and to explore instrument protocols for determining ACS keratometric analogues (KAs). METHODS: Mean keratometry/KAs of the right eye were recorded using Javal-Schiøtz keratometer (J-S), Orbscan IIz and Pentacam from 124 subjects (78 females; mean ± SD age: 24.71 ± 6.61 years). Mean radii of curvature were obtained for 1-mm wide annular zones extending up to 6 mm (horizontally) and 4 mm (vertically) from the apex for Orbscan and Pentacam. Zonal mean radius of curvature was calculated by averaging keratometry values for all measured points within the zone. RESULTS: KA (mean ± SD): Horizontal: Orbscan (7.80 ± 0.31 mm) and J-S (7.82 ± 0.29 mm) were not significantly different (p = 0.072). Pentacam (7.86 ± 0.29 mm) was significantly flatter than J-S (p < 0.001) and Orbscan (p < 0.001). Vertical: Orbscan (7.64 ± 0.31 mm) was significantly steeper than J-S (7.67 ± 0.29 mm, p < 0.005) and Pentacam (7.70 ± 0.29 mm, p < 0.001). Pentacam was significantly flatter than J-S (p < 0.001) and significant flatter than Orbscan across the entire profile (1-4 mm zones horizontal and vertical, p < 0.001).                        LoAs (CI): J-S/Orbscan: ±0.75 mm (0.05-0.18); J-S/Pentacam: ±0.72 mm (0.01-0.12); Pentacam/Orbscan: ±0.16 mm (0.04-0.08). There was a +0.03 mm positive bias for Orbscan compared to J-S, +0.06 mm positive bias for Orbscan compared to Pentacam and -0.03 mm negative bias for Pentacam compared to J-S. CONCLUSIONS: Algorithms used by Orbscan and Pentacam to solve the peripheral paraxial ray problem produce significantly different KAs. Instrument-specific KAs cannot be used inter-changeably between instruments. Differences in KA between instruments are not significant for ocular surgery, but may influence rigid contact lens fitting. Pentacam measures flatter than Orbscan and J-S.


Assuntos
Lentes de Contato , Córnea , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Topografia da Córnea/métodos , Estudos Prospectivos , Córnea/diagnóstico por imagem , Reprodutibilidade dos Testes
18.
PLoS One ; 17(5): e0265828, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35544471

RESUMO

OBJECTIVE: Despite the available evidence regarding effectiveness of stroke telerehabilitation, there has been little focus on factors influencing its delivery or translation from the research setting into practice. There are complex challenges to embedding telerehabilitation into stroke services and generating transferable knowledge about scaling up and routinising this service model. This review aimed to explore factors influencing the delivery of stroke telerehabilitation interventions, including platforms, technical requirements, training, support, access, cost, usability and acceptability. METHODS: MEDLINE, EMBASE, CINAHL, Web of Science and Cochrane Library and Central Registry of Clinical Trials were searched to identify full-text articles of randomised controlled trials (RCTs) and protocols for RCTs published since a Cochrane review on stroke telerehabilitation services. A narrative synthesis was conducted, providing a comprehensive description of the factors influencing stroke telerehabilitation intervention delivery. RESULTS: Thirty-one studies and ten protocols of ongoing studies were included. Interventions were categorised as synchronous telerehabilitation (n = 9), asynchronous telerehabilitation (n = 11) and tele-support (n = 11). Telephone and videoconference were the most frequently used modes of delivery. Usability and acceptability with telerehabilitation were high across all platforms, although access issues and technical challenges may be potential barriers to the use of telerehabilitation in service delivery. Costs of intervention delivery and training requirements were poorly reported. CONCLUSIONS: This review synthesises the evidence relating to factors that may influence stroke telerehabilitation intervention delivery at a crucial timepoint given the rapid deployment of telerehabilitation in response to the COVID-19 pandemic. It recommends strategies, such as ensuring adequate training and technical infrastructure, shared learning and consistent reporting of cost and usability and acceptability outcomes, to overcome challenges in embedding and routinising this service model and priorities for research in this area.


Assuntos
COVID-19 , Acidente Vascular Cerebral , Telerreabilitação , Humanos , Telefone , Telerreabilitação/métodos , Comunicação por Videoconferência
19.
HRB Open Res ; 4: 31, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-36330536

RESUMO

Introduction Recent advances in stroke management and care have resulted in improved survival and outcomes. However, providing equitable access to acute care, rehabilitation and longer-term stroke care is challenging. Recent Irish evidence indicates variation in stroke outcomes across hospitals, and a need for continuous audit of stroke care to support quality improvement. The aim of this project is to develop a core minimum dataset for use in the new Irish National Audit of Stroke (INAS), which aims to improve the standard of stroke care in Ireland. This paper outlines the protocol for conducting a scoping review of international practice and guidelines in auditing acute and non-acute stroke care. Objective Identify data items that are currently collected by stroke audits internationally, and identify audit guidelines that exist for recommending inclusion of content in stroke audit datasets. Methods and analysis This scoping review will be conducted in accordance with the Preferred Reporting Items for Systematic Reviews extension for Scoping Reviews (PRISMA-ScR). We will search the following databases: Medline Ovid; Embase; CINAHL EBSCOHost. Grey literature will also be searched for relevant materials, as will relevant websites. Study selection and review will be carried out independently by two researchers, with discrepancies resolved by a third. Data charting and synthesis will involve sub-dividing relevant sources of evidence, and synthesising data into three categories: i) acute stroke care; ii) non-acute stroke care; and iii) audit data collection procedures and resourcing. Data will be charted using a standardised form specific to each category. Consultation with knowledge users will be conducted at all stages of the scoping review. Discussion This scoping review will contribute to a larger project aimed at developing an internationally benchmarked stroke audit tool that will be used prospectively to collect data on all stroke admissions in Ireland, encompassing both acute and non-acute data items.

20.
Cont Lens Anterior Eye ; 44(2): 192-219, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33775377

RESUMO

This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.


Assuntos
Conjuntivite , Lentes de Contato Hidrofílicas , Piscadela , Túnica Conjuntiva , Córnea , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA