Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38803006

RESUMO

INTRODUCTION: According to current guidelines, pulmonary vein isolation as first-line therapy should be considered for patients with atrial fibrillation (AF), however, optimal timing of the procedure is still unknown in patients with heart failure (HF). We aimed to evaluate the effect of early catheter ablation (CA) in patients with HF and left ventricular ejection fraction (LVEF) below 50%. METHODS: We analyzed data from a structured registry comprising 227 patients with paroxysmal or persistent AF and HF with LVEF < 50% who underwent radiofrequency CA between 2015 and 2022. Early CA was defined as a procedure performed within 12 months of AF diagnosis. The median follow-up duration was 1748 (1176.3-2353.5) days, with a minimum follow-up of 365 days. Our endpoints were AF recurrence after a 3-months blanking period and all-cause mortality. RESULTS: Among the 227 patients with a median age of 64.3 years, 97 (42.7%) experienced AF recurrence and 55 (24.2%) died during the follow-up period. The median LVEF was 40% for early CA and 38% for delayed CA (p = .053). Early CA significantly reduced AF recurrence (HR = 0.25 [0.15-0.42], p < .001), however, the timing of procedure did not affect all-cause mortality (p = .16). These findings were consistent regardless of AF subtype or the burden of comorbidities, as assessed by the CHA2DS2-VASc score. CONCLUSION: The timing of CA of AF appears to be an important factor in patients with HF. Early CA reduced AF recurrence, although it does not impact all-cause mortality. We found similar results regardless of AF subtype or burden of comorbidities.

2.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37931067

RESUMO

AIMS: Cerebral thrombo-embolism is a dreaded complication of pulmonary vein isolation (PVI) for atrial fibrillation; its surrogate, silent cerebral embolism (SCE) can be detected by diffusion-weighted brain magnetic resonance imaging (bMRI). Initial investigations have raised a concern that very high-power, short-duration (vHPSD; 90 W/4 s) temperature-controlled PVI with the QDOT Micro catheter may be associated with a higher incidence of SCE compared with low-power long-duration ablation. We aimed to assess the incidence of procedural complications of vHPSD PVI with an emphasis on cerebral safety. METHODS AND RESULTS: We enrolled 328 consecutive patients undergoing their PVI procedure using vHPSD. A subgroup of 61 consecutive patients underwent diffusion-weighted bMRI within 24 h of the procedure, and incidence and predictors of SCE were studied. The mean procedure time and left atrial dwell time for the overall cohort were 69.6 ± 24.1 and 46.5 ± 21.5 min, respectively. First-pass isolation was achieved in 82%. No stroke or transient ischaemic attack occurred. Silent cerebral embolism was identified in 5 of 61 patients (8.2%). Silent cerebral embolism following procedures was significantly associated with lower baseline generator impedance (105.8 vs. 112.6 Ω, P < 0.0001) and with intermittent loss of catheter-tissue contact during ablation (14.1% vs. 6.1%, P < 0.0001). CONCLUSION: Very high-power, short-duration PVI is a safe technique with an excellent acute success rate. Silent cerebral embolism incidence in our cohort was below the previously reported range, with no clinically overt cerebral complications. Lower baseline generator impedance and loss of contact during ablation may contribute to a higher risk of SCEs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Embolia Intracraniana , Veias Pulmonares , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/epidemiologia , Incidência , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Resultado do Tratamento
3.
Europace ; 24(10): 1636-1644, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35979596

RESUMO

AIMS: Interventional cardiology procedures may expose patients and staff to considerable radiation doses. We aimed to assess whether exposure to ionizing radiation during catheter ablation of supraventricular tachycardia (SVT) can be completely avoided. METHODS AND RESULTS: In this prospective randomized study, patients with SVT (atrioventricular re-entrant tachycardia n = 94, typical atrial flutter n = 29) were randomly assigned in a 1:1 ratio to catheter ablation with conventional fluoroscopic guidance (CF group) or with the EnSite Precision mapping system [zerofluoro (ZF) group]. Acute procedural parameters, increased stochastic risk of cancer incidence and 6-month follow-up data were assessed. Between May 2019 and August 2020, 123 patients were enrolled. Clinical parameters were comparable. Median procedural time was 60.0 and 58.0 min, median fluoroscopy time and estimated median effective dose were 240 s vs. 0 and 0.38 mSv vs. 0 and arrhythmia recurrence was 5% and 7.9% in the CF and ZF groups, respectively. The acute success rate was 98.4% in both groups. No procedure-related complications were reported. At an average age of 55.5 years and median radiation exposure of 0.38 mSv, the estimate of increased incidence was approximately 1 in 14 084. The estimated mortality rate was 1 per 17 857 exposed persons. CONCLUSIONS: The procedural safety and efficacy of the zero-fluoroscopic approach are similar to those of conventional fluoroscopy-based ablation for atrioventricular nodal re-entrant tachycardia and atrial flutter. Under the assumption of low radiation dose, the excessive lifetime risk of malignancy in the CF group due to electrophysiology procedure is reasonably small, whilst totally reduced in zero fluoroscopy procedures.


Assuntos
Flutter Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Supraventricular , Arritmias Cardíacas/cirurgia , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Nó Atrioventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fluoroscopia/métodos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
4.
Heart Vessels ; 37(10): 1769-1775, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35554635

RESUMO

Comparative data are virtually missing about the performance of different electro-anatomical mapping (EAM) system platforms on outflow tract (OT) premature ventricular complex (PVC) ablation outcomes with manual ablation catheters. We aimed to compare the acute success-, complication-, and long-term recurrence rates of impedance-based (IMP) and magnetic field-based (MAG) EAM platforms in manual OT PVC ablation. Single-centre, propensity score matched data of 39-39 patients ablated for OT PVCs in 2015-17 with IMP or MAG platforms were analysed. Acute success rate, peri-procedural complications, post-ablation daily PVC burden, and long-term recurrence rates were compared on intention-to-treat basis. Acute success rate was similar in the IMP and MAG group (77 vs. 82%, p = 0.78). There was a single case of femoral pseudo-aneurysm and no cardiac tamponade occurred. PVC burden fell significantly from baseline 24.0% [15.0-30.0%] to 3.3% [0.25-10.5%] (p < 0.001) post-ablation, with no difference between EAM platforms (IMP: 2.6% [0.5-12.0%] vs. MAG: 4.0% [2.0-6.5%]; p = 0.60). There was no significant difference in recurrence-free survival of the intention-to-treat cohort of the IMP and MAG groups (54 vs. 60%, p = 0.82, respectively) during 12 months of follow-up. Ablation with the aid of both impedance- and magnetic field-based EAM platforms can considerably reduce OT PVC burden and give similar acute- and long-term freedom from arrhythmia.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Campos Magnéticos , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
5.
Europace ; 23(3): 479-485, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33083819

RESUMO

Data on reprocessing of electrophysiology (EP) materials are sparse. Reprocessing of catheters and other materials in daily routine varies through countries and may depend on specific material characteristics, supplier, or federal law. The aim of this study was to collect data on reprocessing usage through EHRA countries. An online survey consisting of 27 questions was distributed to EHRA Young EP members and members of national EP working groups. Two hundred and two participants from 34 EHRA countries completed the survey. One hundred and seven respondents (53.0%) reported having used and using reprocessed EP material, 30 (14.9%) respondents have used reprocessed EP material in the past but not at the time of the survey, 65 (32.2%) had never used reprocessed EP material. The most reprocessed EP materials include cables (70%), diagnostic EP catheters with deflectable (64%) or fixed curve (63%), non-irrigated ablation catheters (51%), and other conventional diagnostic catheters (41%). The most durable material was diagnostic EP catheters with a fixed curve (61%), the most sensitive material was ablation catheters with contact force sensors (21%). Important benefits were seen in reducing costs for the providing hospital (65%) and the healthcare provider (42%) and making EP procedures available for a greater number of patients (42%). Main concerns were on quality aspects (58%), contamination (52%), and loss of precision (47%). Reprocessing of EP materials is heterogeneously managed among EHRA countries. The present survey shows that European electrophysiologists consider the use of reprocessed EP material as generally safe and cost-effective.


Assuntos
Eletrofisiologia Cardíaca , Ablação por Cateter , Humanos , Inquéritos e Questionários
6.
Europace ; 23(4): 596-602, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33576378

RESUMO

AIMS: Unlike in atrial fibrillation ablation, there is a lack of appropriately sized and properly designed studies regarding outflow tract (OT) premature ventricular complex (PVC) ablation outcomes with contact force sensing (CFS) catheters. We aimed to compare the acute success-, complication-, and long-term recurrence rates of manual CFS catheters with traditional irrigated catheters (T) in OT PVC ablation. METHODS AND RESULTS: Single-centre, propensity-matched data of 75-75 patients ablated for right-sided OT (RVOT) or left-sided OT (LVOT) PVCs in 2015-17 with CFS or T catheters were compared. Acute success rate, peri-procedural complications, post-procedural daily PVC burden, and long-term recurrence rates were compared on intention-to-treat basis. Acute success rate equalled 80% in both groups, with no difference in force values in the CFS group comparing successful or failed cases [12.0 (8.75-17.0) vs. 16.0 (10.25-22.25) g, P = 0.21]. There were three cases of pseudo-aneurysm and one cardiac tamponade. PVC burden fell significantly from baseline 22 (15-30)% to 2 (0-10)% (P < 0.0001), with no difference between catheter types [CFS: 1 (0-7)% vs. T: 4 (1-12) %; P = 0.21]. There was no significant difference in recurrence-free survival of CFS and T catheters (58 vs. 59%, P = 0.29) during 12 months of follow-up, respectively. Recurrence in the CFS group did not differ either by the force exerted below or above the median value of 12 g (P = 0.66). CONCLUSION: Both types of catheters can effectively reduce OT PVC burden with minimal serious complication rates. Ablation with CFS or T catheters gives similar acute- and long-term results.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Humanos , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
7.
Europace ; 21(12): 1865-1875, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31617896

RESUMO

AIMS: While improvement in quality of life (QoL) has been widely reported in cardiac resynchronization therapy (CRT) patients, its predictive value is not well-understood. We aimed to assess the predictive role of baseline QoL on long-term heart failure (HF) or death events in mild HF patients enrolled in Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT). METHODS AND RESULTS: A total of 1791 of 1820 patients had their QoL evaluated at baseline, using the EuroQol-5 dimensions (EQ-5D) and the Kansas City Cardiomyopathy Questionnaires (KCCQ). Kaplan-Meier survival analyses and multivariate Cox models were utilized. Issues within any of the domains of the baseline EQ-5D questionnaire (mobility, self-care, usual activities, pain/discomfort, and anxiety/depression) were associated with long-term mortality (median follow-up 5.6 years) (all P < 0.05). Heart failure or death events were predicted by issues in baseline mobility [hazard ratio (HR) = 1.41, P < 0.001], usual activities (HR = 1.41, P < 0.001), and anxiety/depression (HR = 1.21, P = 0.035). The risk of HF events alone was significantly higher in patients with baseline mobility issues (HR = 1.42, P < 0.001) or usual activity (HR = 1.35, P = 0.003). Every 10% increase in the visual analogue scale (0-100) was associated with an 8% lower risk of all-cause mortality (P = 0.006), and a 6% lower risk of HF/death (P = 0.002). Mobility issues also predicted echocardiographic reverse remodelling (-33.08 mL vs. -31.17 mL, P = 0.043). Using the KCCQ, patients in the lower tertile of the clinical summary or physical limitations score had a significantly higher risk of long-term HF or death (P < 0.05). CONCLUSION: In mild HF patients enrolled in MADIT-CRT, multiple baseline QoL questionnaire domains were predictors of echocardiographic remodelling, long-term all-cause mortality, and HF events.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Mortalidade , Qualidade de Vida , Atividades Cotidianas , Idoso , Ansiedade/psicologia , Depressão/psicologia , Progressão da Doença , Ecocardiografia , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/psicologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Limitação da Mobilidade , Análise Multivariada , Dor/fisiopatologia , Prognóstico , Modelos de Riscos Proporcionais , Fatores de Risco , Autocuidado , Índice de Gravidade de Doença
8.
Europace ; 21(8): 1237-1245, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31168608

RESUMO

AIMS: The aim of our study was to investigate the long-term efficacy and safety of transseptal endocardial left ventricular lead implantation (TELVLI). METHODS AND RESULTS: Transseptal endocardial left ventricular lead implantation was performed in 54 patients (44 men, median age 69, New York Heart Association III-IV stage) between 2007 and 2017 in a single centre. In 36 cases, the transseptal puncture (TP) was performed via the femoral vein, and in 18 cases, the TP and also the left ventricular (LV) lead placement were performed via the subclavian vein. An electrophysiological deflectable catheter was used to reach the LV wall through the dilated TP hole. The LV lead implantation was successful in all patients. A total of 54 patients were followed up for a median of 29 months [interquartile range (IQR) 8-40 months], the maximum follow-up time was 94 months. Significant improvement in the LV ejection fraction was observed at the 3-month visit, from the median of 27% (IQR 25-34%) to 33% (IQR 32-44%), P < 0.05. Early lead dislocation was observed in three cases (5%), reposition was performed using the original puncture site in all. The patients were maintained on anticoagulation therapy with a target international normalized ratio between 2.5 and 3.5. Four thromboembolic events were noticed during follow-up. A total of 27 patients died, with a median survival of 15 months (IQR 6-40). CONCLUSION: The TELVLI is an effective approach for cardiac resynchronization therapy (CRT) however it is associated with a substantial thromboembolic risk (7%).


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Septos Cardíacos/cirurgia , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese , Tromboembolia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Feminino , Ventrículos do Coração/cirurgia , Humanos , Hungria , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Retenção da Prótese/métodos , Retenção da Prótese/estatística & dados numéricos , Tromboembolia/epidemiologia , Tromboembolia/etiologia
9.
Heart Fail Rev ; 23(1): 15-26, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29047028

RESUMO

Patients with conventional pacemakers or implanted defibrillators are often considered for cardiac resynchronization therapy (CRT). Our aim was to summarize the available evidences regarding the clinical benefits of upgrade procedures. A systematic literature search was performed from studies published between 2006 and 2017 in order to compare the outcome of CRT upgrade vs. de novo implantations. Outcome data on all-cause mortality, heart failure events, New York Heart Association (NYHA) Class, QRS narrowing and echocardiographic parameters were analysed. A total of 16 reports were analysed comprising 489,568 CRT recipients, of whom 468,205 patients underwent de novo and 21,363 upgrade procedures. All-cause mortality was similar after CRT upgrade compared to de novo implantations (RR 1.19, 95% CI 0.88-1.60, p = 0.27). The risk of heart failure was also similar in both groups (RR 0.96, 95% CI 0.70-1.32, p = 0.81). There was no significant difference in clinical response after CRT upgrade compared to de novo implantations in terms of improvement in left ventricular ejection fraction (ΔEF de novo - 6.85% vs. upgrade - 9.35%; p = 0.235), NYHA class (ΔNYHA de novo - 0.74 vs. upgrade - 0.70; p = 0.737) and QRS narrowing (ΔQRS de novo - 9.6 ms vs. upgrade - 29.5 ms; p = 0.485). Our systematic review and meta-analysis of currently available studies reports that CRT upgrade is associated with similar risk for all-cause mortality compared to de novo resynchronization therapy. Benefits on reverse remodelling and functional capacity improved similarly in both groups suggesting that CRT upgrade may be safely and effectively offered in routine practice. CLINICAL TRIAL REGISTRATION: Prospero Database-CRD42016043747.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Função Ventricular Esquerda/fisiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Resultado do Tratamento
10.
Europace ; 20(9): 1506-1512, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29182734

RESUMO

Aims: There are previous studies on quality of life (QoL) in cardiac resynchronization therapy (CRT) patients; however, there are no data with the short EuroQol-five dimensions (EQ-5D) questionnaire predicting outcomes. We aimed to assess the predictive role of baseline QoL and QoL change at 6 months after CRT with EQ-5D on 5-year mortality and response. Methods and results: In our prospective follow-up study, 130 heart failure (HF) patients undergoing CRT were enrolled. Clinical evaluation, echocardiography, and EQ-5D were performed at baseline and at 6 months of follow-up, continued to 5 years. Primary endpoint was all-cause mortality at 5 years. Secondary endpoints were (i) clinical response with at least one class improvement in New York Heart Association without HF hospitalization and (ii) reverse remodelling with 15% reduction in left ventricular end-systolic volume at 6 months. Fifty-four (41.5%) patients died during 5 years, 85 (65.3%) clinical responders were identified, and 63 patients (48.5%) had reverse remodelling. Baseline issues with mobility were associated with lower response [odds ratio (OR) 0.36, 95% confidence interval (CI) 0.16-0.84; P = 0.018]. Lack of reverse remodelling correlated with self-care issues at baseline (OR 0.10, 95% CI 0.01-0.94; P = 0.04). Furthermore, self-care difficulties [hazard ratio (HR) 2.39, 95% CI 1.17-4.86; P = 0.01) or more anxiety (HR 1.51, 95% CI 1.00-2.26; P = 0.04) predicted worse long-term survival. At 6 months, mobility (HR 3.95, 95% CI 1.89-8.20; P < 0.001), self-care (HR 7.69, 95% CI 2.23-25.9; P = 0.001), or ≥ 10% visual analogue scale (VAS) (HR 2.24, 95% CI 1.27-3.94; P = 0.005) improvement anticipated better survival at 5 years. Conclusion: EuroQol-five dimension is a simple method assessing QoL in CRT population. Mobility issues at baseline are associated with lower clinical response, whereas self-care issues predict lack of reverse remodelling. Problems with mobility or anxiety before CRT and persistent issues with mobility, self-care, and VAS scale at 6 months predict adverse outcome.


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Mortalidade , Qualidade de Vida , Remodelação Ventricular , Atividades Cotidianas , Idoso , Ansiedade/psicologia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/psicologia , Depressão/psicologia , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Limitação da Mobilidade , Razão de Chances , Dor/fisiopatologia , Dor/psicologia , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos , Inquéritos e Questionários , Resultado do Tratamento
11.
Inflamm Res ; 65(12): 933-940, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27492980

RESUMO

BACKGROUND: The chronic inflammation plays an important role in heart failure and complement components might be useful markers of the prognosis. We set out to evaluate their predictive value in the clinical outcomes of patients with cardiac resynchronization therapy (CRT). METHODS: We determined the complement levels C3, C3a, sC5b-9 and also the N-terminus of the prohormone brain natriuretic peptide (NT-proBNP) of 126 heart failure patients in a prospective, single-center observational study before and 6 months after CRT implantation. RESULTS: CRT reduced the C3a [212.5 (148.2-283.6) vs. 153 (119.8-218.3) ng/mL, p < 0.0001] and the sC5b-9 levels [296.9 (234.2-358.8) vs. 255.1 (210.1-319.0) ng/mL, p = 0.0006], but not the total C3 levels [1.43 (1.26-1.61) vs. 1.38 (1.23-1.57) g/L, p = 0.57]. C3a predicted the 5-year mortality of the patients [C3a > 165 ng/mL hazard ratio = 4.21 (1.65-10.72), p = 0.003] independent of the NT-proBNP and other factors. After reclassification, we observed a significant net reclassification improvement [NRI = 0.71 (0.43-0.98), p < 0.0001] and integrated discrimination improvement [IDI = 0.08 (0.03-0.12), p = 0.0002]. CONCLUSIONS: In patients with CRT, elevated C3a levels increase the risk of mortality independent of the NT-proBNP levels or other factors. CRT exerts anti-inflammatory effect by reducing the complement activation.


Assuntos
Terapia de Ressincronização Cardíaca , Proteínas do Sistema Complemento/análise , Insuficiência Cardíaca , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Idoso , Ativação do Complemento , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade
12.
J Clin Med ; 13(7)2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38610727

RESUMO

Background: Atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) is predominantly attributed to pulmonary vein reconnection (PVR). Predictors of AF recurrence have been widely studied; however, data are scarce on procedural parameters that predict chronic PVR. We aimed to study PVR rates and predictors of PVR. Methods: We retrospectively included 100 patients who underwent repeated ablation due to AF recurrence after initial PVI with the CARTO system. PVR was determined during the repeated procedure by electrophysiological evaluation, and initial procedural characteristics predicting PVR were studied, including adherence to the CLOSE protocol, use of high power, first-pass isolation (FPI), and baseline generator impedance (BGI). Results: Thirty-eight patients underwent initial CLOSE-guided PVI, and sixty-two underwent initial non-CLOSE PVI. A repeat procedure was performed 23 ± 16 months after the initial procedure. In total, PVR was found in 192 of 373 PVs (51.5%), and all PVs were isolated in 17/100 (17%) patients. Factors associated with all PVs being isolated were adherence to the CLOSE protocol, a higher power setting, the presence of bilateral FPI, and lower BGI (88% vs. 28%, p < 0.0001; 37.5 W vs. 30 W, p = 0.0276; 88.2% vs. 40.4%, p = 0.0007; and 127.6 Ω vs. 136.6 Ω, p = 0.0027, respectively). In initial procedures with adherence to the CLOSE protocol, the FPI rate was significantly higher (73.7% vs. 25%, p < 0.0001), while there were no significant differences in terms of procedure time and left atrial dwell time (81 vs. 85 min, p = 0.83; and 60 vs. 58 min, p = 0.08, respectively). BGI ≥ 130 Ω (AUC = 0.7403, sensitivity: 77.1%, specificity: 68.8%, p = 0.0032) was associated with a significantly higher probability of PVR (OR = 6.757; p < 0.0001). In multivariable analysis, independent predictors for PVR were non-adherence to the CLOSE protocol and BGI ≥ 130 Ω. Conclusions: Our findings indicate that adherence to the CLOSE protocol and baseline generator impedance < 130 Ω during AF ablation are independent predictors of PVI durability.

13.
Bioengineering (Basel) ; 10(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38135977

RESUMO

BACKGROUND: Ventricular tachycardia (VT) recurrence after catheter ablation remains a concern, emphasizing the need for precise risk assessment. We aimed to use machine learning (ML) to predict 1-month and 1-year VT recurrence following VT ablation. METHODS: For 337 patients undergoing VT ablation, we collected 31 parameters including medical history, echocardiography, and procedural data. 17 relevant features were included in the ML-based feature selection, which yielded six and five optimal features for 1-month and 1-year recurrence, respectively. We trained several supervised machine learning models using 10-fold cross-validation for each endpoint. RESULTS: We observed 1-month VT recurrence was observed in 60 (18%) cases and accurately predicted using our model with an area under the receiver operating curve (AUC) of 0.73. Input features used were hemodynamic instability, incessant VT, ICD shock, left ventricular ejection fraction, TAPSE, and non-inducibility of the clinical VT at the end of the procedure. A separate model was trained for 1-year VT recurrence (observed in 117 (35%) cases) with a mean AUC of 0.71. Selected features were hemodynamic instability, the number of inducible VT morphologies, left ventricular systolic diameter, mitral regurgitation, and ICD shock. For both endpoints, a random forest model displayed the highest performance. CONCLUSIONS: Our ML models effectively predict VT recurrence post-ablation, aiding in identifying high-risk patients and tailoring follow-up strategies.

14.
J Am Coll Cardiol ; 82(6): 489-499, 2023 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-37225045

RESUMO

BACKGROUND: Limited data exist to characterize novel measures of right ventricular (RV) function and the coupling to pulmonary circulation in patients with heart failure and preserved left ventricular ejection fraction (HFpEF). OBJECTIVES: This study sought to assess the clinical implications of RV function, the association with N-terminal pro-B-type natriuretic peptide, and the risk for adverse events among patients with HFpEF. METHODS: This study analyzed measures of RV function by assessing absolute RV free wall longitudinal strain (RVFWLS) and its ratio to estimated pulmonary artery systolic pressure (PASP) (RVFWLS/PASP ratio) in 528 patients (mean age 74 ± 8 years, 56% female) with adequate echocardiographic images quality enrolled in the PARAGON-HF trial. Associations with baseline N-terminal pro-B-type natriuretic peptide and with total HF hospitalizations and cardiovascular death were assessed, after accounting for confounders. RESULTS: Overall, 311 patients (58%) had evidence of RV dysfunction, defined as absolute RVFWLS <20%, and among the 388 patients (73%) with normal tricuspid annular planar systolic excursion and RV fractional area change, more than one-half showed impaired RV function. Lower values of RVFWLS and RVFWLS/PASP ratios were significantly associated with higher circulating N-terminal pro-B-type natriuretic peptide. With a median follow-up of 2.8 years, there were 277 total HF hospitalizations and cardiovascular deaths. Both absolute RVFWLS (HR: 1.39; 95% CI: 1.05-1.83; P = 0.018) and RVFWLS/PASP ratio (HR: 1.43; 95% CI: 1.13-1.80; P = 0.002) were significantly associated with the composite outcome. Treatment effect of sacubitril/valsartan was not modified by measures of RV function. CONCLUSIONS: Worsening RV function and its ratio to pulmonary pressure is common and significantly associated with an increased risk of HF hospitalizations and cardiovascular death in patients with HFpEF. (Efficacy and Safety of LCZ696 Compared to Valsartan, on Morbidity and Mortality in Heart Failure Patients With Preserved Ejection Fraction [PARAGON-HF]; NCT01920711).


Assuntos
Insuficiência Cardíaca , Disfunção Ventricular Direita , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Peptídeo Natriurético Encefálico/uso terapêutico , Prognóstico , Volume Sistólico , Função Ventricular Esquerda , Função Ventricular Direita
15.
ESC Heart Fail ; 10(3): 2051-2065, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36907651

RESUMO

ESCAPE: Evaluation of a patient-centred biopsychosocial blended collaborative care pathway for the treatment of multimorbid elderly patients. THERAPEUTIC AREA: Healthcare interventions for the management of older patients with multiple morbidities. AIMS: Multi-morbidity treatment is an increasing challenge for healthcare systems in ageing societies. This comprehensive cohort study with embedded randomized controlled trial tests an integrated biopsychosocial care model for multimorbid elderly patients. HYPOTHESIS: A holistic, patient-centred pro-active 9-month intervention based on the blended collaborative care (BCC) approach and enhanced by information and communication technologies can improve health-related quality of life (HRQoL) and disease outcomes as compared with usual care at 9 months. METHODS: Across six European countries, ESCAPE is recruiting patients with heart failure, mental distress/disorder plus ≥2 medical co-morbidities into an observational cohort study. Within the cohort study, 300 patients will be included in a randomized controlled assessor-blinded two-arm parallel group interventional clinical trial (RCT). In the intervention, trained care managers (CMs) regularly support patients and informal carers in managing their multiple health problems. Supervised by a clinical specialist team, CMs remotely support patients in implementing the treatment plan-customized to the patients' individual needs and preferences-into their daily lives and liaise with patients' healthcare providers. An eHealth platform with an integrated patient registry guides the intervention and helps to empower patients and informal carers. HRQoL measured with the EQ-5D-5L as primary endpoint, and secondary outcomes, that is, medical and patient-reported outcomes, healthcare costs, cost-effectiveness, and informal carer burden, will be assessed at 9 and ≥18 months. CONCLUSIONS: If proven effective, the ESCAPE BCC intervention can be implemented in routine care for older patients with multiple morbidities across the participating countries and beyond.


Assuntos
Prestação Integrada de Cuidados de Saúde , Insuficiência Cardíaca , Humanos , Idoso , Qualidade de Vida , Estudos de Coortes , Multimorbidade , Resultado do Tratamento , Insuficiência Cardíaca/terapia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Observacionais como Assunto
16.
Front Cardiovasc Med ; 9: 941434, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35911564

RESUMO

Introduction: Pulmonary vein isolation is the cornerstone of rhythm-control therapy for atrial fibrillation (AF). The very high-power, short-duration (vHPSD) radiofrequency (RF) ablation is a novel technology that favors resistive heating while decreasing the role of conductive heating. Our study aimed to evaluate the correlations between contact force (CF), power, impedance drop (ID), and temperature; and to assess their role in lesion formation with the vHPSD technique. Methods: Consecutive patients who underwent initial point-by-point RF catheter ablation for AF were enrolled in the study. The vHPSD ablation was performed applying 90 W for 4 s with an 8 ml/min irrigation rate. Results: Data from 85 patients [median age 65 (59-71) years, 34% female] were collected. The median procedure time, left atrial dwelling time, and fluoroscopy time were 70 (60-90) min, 49 (42-58) min, and 7 (5-11) min, respectively. The median RF time was 312 (237-365) sec. No steam pop nor major complications occurred. A total of 6,551 vHPSD RF points were analyzed. The median of CF, maximum temperature, and ID were 14 (10-21) g, 47.6 (45.1-50.4) °C, and 8 (6-10) Ohms, respectively. CF correlated significantly with the maximum temperature (p < 0.0001). A CF of 5 g and above was associated with a significantly higher temperature compared to those lesions with a CF below 5 grams (p < 0.0001). Bilateral first-pass isolation rate was 84%. The 6-month AF-recurrence rate was 7%. Conclusion: The maximum temperature and CF significantly correlate with each other during vHPSD applications. A CF ≥ 5 g leads to better tissue heating and thus might be more likely to result in good lesion formation, although this clinical study was unable to assess actual lesion sizes.

17.
Front Cardiovasc Med ; 9: 935705, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35872909

RESUMO

Introduction: High-power short-duration (HPSD) radiofrequency ablation has been proposed to produce rapid and effective lesions for pulmonary vein isolation (PVI). We aimed to evaluate the procedural characteristics and the first-pass isolation (FPI) rate of HPSD and very high-power short-duration (vHPSD) ablation compared to the low-power long-duration (LPLD) ablation technique. Methods: One hundred fifty-six patients with atrial fibrillation (AF) were enrolled and assigned to LPLD, HPSD, or vHPSD PVI. The energy setting was 30, 50, and 90 W in the LPLD, HPSD, and vHPSD groups, respectively. In the vHPSD group, 90 W/4 s energy delivery was used in the QMODE+ setting. In the other groups, ablation index-guided applications were delivered with 30 W (LPLD) or 50 W (HPSD). Results: Bilateral PVI was achieved in all cases. Compared to the LPLD group, the HPSD and vHPSD groups had shorter procedure time [85 (75-101) min, 79 (65-91) min, and 70 (53-83) min], left atrial dwelling time [61 (55-70) min, 53 (41-56) min, and 45 (34-52) min], total RF time [1,567 (1,366-1,761) s, 1,398 (1,021-1,711) s, and 336 (247-386) s], but higher bilateral FPI rate (57, 78, and 80%) (all p-values < 0.01). The use of HPSD (OR = 2.72, 95% CI 1.15-6.44, p = 0.023) and vHPSD (OR = 2.90, 95% CI 1.24-6.44, p = 0.014) ablation techniques were associated with a higher probability of bilateral FPI. The 9-month AF-recurrence rate was lower in case of HPSD and vHPSD compared to LPLD ablation (10, 8, and 36%, p = 0.0001). Moreover, the presence of FPI was associated with a lower AF-recurrence rate at 9-month (OR = 0.09, 95% CI 0.04-0.24, p = 0.0001). Conclusion: Our prospective, observational cohort study showed that both HPSD and vHPSD RF ablation shortens procedure and RF time and results in a higher rate of FPI compared to LPLD ablation. Moreover, the use of HPSD and vHPSD ablation increased the acute and mid-term success rate. No safety concerns were raised for HPSD or vHPSD ablation in our study.

18.
Front Cardiovasc Med ; 9: 1061471, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36561769

RESUMO

Aims: We aimed to establish sex-specific predictors for 1-year VT recurrence and 1-year all-cause mortality in patients with structural heart disease undergoing catheter ablation. Methods: We analyzed data of 299 patients recorded in our structured registry. These included medical history, echocardiography parameters, laboratory results, VT properties, procedural data. Results: Out of the 299 patients, 34 (11%) were female. No significant difference was found between women and men in terms of VT recurrence (p = 0.74) or mortality (p = 0.07). In females, severe mitral regurgitation (MR), tricuspid regurgitation (TR), presentation with incessant VT, and preprocedural electrical storm (ES) were associated with increased risk of VT recurrence. Diabetes, implanted CRT, VT with hemodynamic instability, ES and advanced MR were the risk factors of mortality in women. ACEi/ARB use predicted a favorable outcome in both endpoints among females. In men, independent predictors of VT recurrence were the composite parameter of ES and multiple ICD therapies, presentation with incessant VT, severe MR, while independent predictors of mortality were age, LVEF, creatinine and previously implanted CRT. Conclusion: According to our investigation, there are pronounced sex differences in predictors of recurrence and mortality following VT ablation.

19.
Front Cardiovasc Med ; 9: 708298, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35242821

RESUMO

INTRODUCTION: The role of the spatial relationship between the left superior pulmonary vein (LSPV) and left atrial appendage (LAA) is unknown. We sought to evaluate whether an abutting LAA and LSPV play a role in AF recurrence after catheter ablation for paroxysmal AF. METHODS: Consecutive patients, who underwent initial point-by-point radiofrequency catheter ablation for paroxysmal AF at the Heart and Vascular Center of Semmelweis University, Budapest, Hungary, between January of 2014 and December of 2017, were enrolled in the study. All patients underwent pre-procedural cardiac CT to assess left atrial (LA) and pulmonary vein (PV) anatomy. Abutting LAA-LSPV was defined as cases when the minimum distance between the LSPV and LAA was less than 2 mm. RESULTS: We included 428 patients (60.7 ± 10.8 years, 35.5% female) in the analysis. AF recurrence rate was 33.4%, with a median recurrence-free time of 21.2 (8.8-43.0) months. In the univariable analysis, female sex (HR = 1.45; 95%CI = 1.04-2.01; p = 0.028), LAA flow velocity (HR = 1.01; 95%CI = 1.00-1.02; p = 0.022), LAA orifice area (HR = 1.00; 95%CI = 1.00-1.00; p = 0.028) and abutting LAA-LSPV (HR = 1.53; 95%CI = 1.09-2.14; p = 0.013) were associated with AF recurrence. In the multivariable analysis, abutting LAA-LSPV (adjusted HR = 1.55; 95%CI = 1.04-2.31; p = 0.030) was the only independent predictor of AF recurrence. CONCLUSION: Abutting LAA-LSPV predisposes patients to have a higher chance for arrhythmia recurrence after catheter ablation for paroxysmal AF.

20.
Clin Cardiol ; 45(3): 273-281, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34799870

RESUMO

INTRODUCTION: There are no consistently confirmed predictors of atrial fibrillation (AF) recurrence after catheter ablation. Therefore, we aimed to study whether left atrial appendage volume (LAAV) and function influence the long-term recurrence of AF after catheter ablation, depending on AF type. METHODS: AF patients who underwent point-by-point radiofrequency catheter ablation after cardiac computed tomography (CT) were included in this analysis. LAAV and LAA orifice area were measured by CT. Uni- and multivariable Cox proportional hazard regression models were performed to determine the predictors of AF recurrence. RESULTS: In total, 561 AF patients (61.9 ± 10.2 years, 34.9% females) were included in the study. Recurrence of AF was detected in 40.8% of the cases (34.6% in patients with paroxysmal and 53.5% in those with persistent AF) with a median recurrence-free time of 22.7 (9.3-43.1) months. Patients with persistent AF had significantly higher body surface area-indexed LAV, LAAV, and LAA orifice area and lower LAA flow velocity, than those with paroxysmal AF. After adjustment left ventricular ejection fraction (LVEF) <50% (HR = 2.17; 95% CI = 1.38-3.43; p < .001) and LAAV (HR = 1.06; 95% CI = 1.01-1.12; p = .029) were independently associated with AF recurrence in persistent AF, while no independent predictors could be identified in paroxysmal AF. CONCLUSION: The current study demonstrates that beyond left ventricular systolic dysfunction, LAA enlargement is associated with higher rate of AF recurrence after catheter ablation in persistent AF, but not in patients with paroxysmal AF.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Recidiva , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA