Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circ J ; 87(5): 619-628, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36418112

RESUMO

BACKGROUND: The vessel healing process after implantation of biodegradable polymer (BP) and durable polymer (DP) everolimus-eluting stent (EES) in ST-elevation myocardial infarction (STEMI) lesions remains unclear.Methods and Results: We conducted a multicenter prospective randomized controlled trial to compare early (2 weeks) and mid-term (12 months) vascular responses after implantation of BP-EES vs. DP-EES in STEMI patients. In this prespecified subanalysis, serial coronary angioscopy (CAS) analysis was performed in 15 stents in the BP-EES arm (n=10 patients) and 14 stents in the DP-EES arm (n=10 patients). At the 2-week follow-up, there was no significant difference in the estimated marginal means of the neointimal coverage grade (primary endpoint) between the 2 arms (mean [±SE] 0.00±0.00 in both arms; P>0.999). There were no significant differences between the BP-EES and DP-EES groups in the yellow color grade (1.046±0.106 vs. 0.844±0.114, respectively; P=0.201) or the presence of thrombus (77.8% vs. 88.8%, respectively; P=0.205). At 12 months, competent strut coverage, defined as yellow color grade ≤1, no thrombus, and a neointimal coverage grade ≥1 was achieved more frequently in the BP-EES than DP-EES arm (85.2% vs. 53.1%; adjusted odds ratio 2.11 [95% confidence interval 1.26-3.53]; P=0.023). CONCLUSIONS: Neointimal coverage 2 weeks after implantation of BP-EES and DP-EES in STEMI lesions was comparable on CAS evaluation. However, at 1 year, BP-EES was independently associated with competent strut coverage.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Everolimo , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Sirolimo , Doença da Artéria Coronariana/terapia , Polímeros , Angioscopia , Estudos Prospectivos , Resultado do Tratamento , Implantes Absorvíveis
2.
Circ J ; 87(6): 857-865, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-36908118

RESUMO

BACKGROUND: P2Y12 inhibitor monotherapy without aspirin immediately after percutaneous coronary intervention (PCI) has not been tested in East Asian patients, so in this study we aimed to assess the safety and feasibility of reduced dose (3.75 mg/day) prasugrel monotherapy in Japanese patients presenting with chronic coronary syndrome (CCS).Methods and Results: ASET-JAPAN is a prospective, multicenter, single-arm pilot study that completed enrolment of 206 patients from 12 Japanese centers in September 2022. Patients with native de-novo coronary lesions and a SYNTAX score <23 were treated exclusively with biodegradable-polymer platinum-chromium everolimus-eluting stent(s). Patients were loaded with standard dual antiplatelet therapy (DAPT) and following successful PCI and optimal stent deployment, they received low-dose prasugrel (3.75 mg/day) monotherapy for 3 months. The primary ischemic endpoint was a composite of cardiac death, spontaneous target-vessel myocardial infarction, or definite stent thrombosis. The primary bleeding endpoint was Bleeding Academic Research Consortium (BARC) type 3 or 5. At 3-month follow-up, there were no primary bleeding or ischemic events, or any stent thrombosis. CONCLUSIONS: This pilot study showed the safety and feasibility of prasugrel monotherapy in selected low-risk Japanese patients with CCS. This "aspirin-free" strategy may be a safe alternative to traditional DAPT following PCI.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Cloridrato de Prasugrel , Humanos , Aspirina , População do Leste Asiático , Everolimo , Hemorragia , Japão , Intervenção Coronária Percutânea/métodos , Projetos Piloto , Platina , Polímeros , Cloridrato de Prasugrel/uso terapêutico , Estudos Prospectivos
4.
Catheter Cardiovasc Interv ; 90(1): 58-69, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27896897

RESUMO

BACKGROUND: Limited data are currently available on the performance of everolimus eluting bioresorbable vascular scaffold (BVS) for treatment of complex coronary lesions representative of daily practice. METHODS: This is a prospective, mono-center, single-arm study, reporting data after BVS implantation in patients presenting with stable, unstable angina, or non-ST segment elevation myocardial infarction caused by de novo stenotic lesions in native coronary arteries. No restrictions were applied to lesion complexity. Procedural results and 12-month clinical outcomes were reported. RESULTS: A total of 180 patients have been evaluated in the present study, with 249 treated coronary lesions. Device Success per lesion was 99.2%. A total of 119 calcified lesions were treated. Comparable results were observed among severe, moderate and noncalcified lesions in term of %diameter stenosis (%DS) (20.3 ± 10.5%, 17.8 ± 7.7%, 16.8 ± 8.6%; P = 0.112) and acute gain (1.36 ± 0.41 mm, 1.48 ± 0.44 mm, 1.56 ± 0.54 mm; P = 0.109). In bifurcations (54 lesions), side-branch ballooning after main vessel treatment was often performed (33.3%) with low rate of side-branch impairment (9.3%). A total of 29 cases with coronary total occlusions were treated. After BVS implantation %DS was not different from other lesion types (17.2 ± 9.4%, vs. 17.7 ± 8.6%; P = 0.780). At one year, all-cause mortality was reported in three cases. The rate of target lesion revascularization and target vessel revascularization was 3.3%. The rate of definite scaffold thrombosis was 2.6%. CONCLUSIONS: The implantation of the everolimus eluting bioresorbable vascular scaffold in an expanded range of coronary lesion types and clinical presentations was observed to be feasible with promising angiographic results and mid-term clinical outcomes. © 2016 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Angina Estável/terapia , Angina Instável/terapia , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/terapia , Everolimo/administração & dosagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Calcificação Vascular/terapia , Idoso , Angina Estável/diagnóstico por imagem , Angina Estável/mortalidade , Angina Instável/diagnóstico por imagem , Angina Instável/mortalidade , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Tomada de Decisão Clínica , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Everolimo/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Seleção de Pacientes , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/mortalidade
5.
Catheter Cardiovasc Interv ; 89(4): 679-689, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28109054

RESUMO

By providing valuable information about the coronary artery wall and lumen, intravascular imaging may aid in optimizing interventional procedure results and thereby could improve clinical outcomes following percutaneous coronary intervention (PCI). Intravascular optical coherence tomography (OCT) is a light-based technology with a tissue penetration of approximately 1 to 3 mm and provides near histological resolution. It has emerged as a technological breakthrough in intravascular imaging with multiple clinical and research applications. OCT provides detailed visualization of the vessel following PCI and provides accurate assessment of post-procedural stent performance including detection of edge dissection, stent struts apposition, tissue prolapse, and healing parameters. Additionally, it can provide accurate characterization of plaque morphology and provides key information to optimize post-procedural outcomes. This manuscript aims to review the current clinical and research applications of intracoronary OCT and summarize the analytic OCT imaging software packages currently available. © 2017 Wiley Periodicals, Inc.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/métodos , Placa Aterosclerótica/diagnóstico , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Doença da Artéria Coronariana/cirurgia , Humanos , Placa Aterosclerótica/cirurgia , Reprodutibilidade dos Testes
6.
Circ J ; 80(5): 1131-41, 2016 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-26936236

RESUMO

BACKGROUND: The edge vascular response (EVR) has been linked to important prognostic implications in patients treated with permanent metallic stents. We aimed to investigate the relationship of EVR with the geometric changes in the everolimus-eluting bioresorbable scaffold using serial optical coherence tomography (OCT) analysis. METHODS AND RESULTS: In the first-in-man ABSORB trial, 28 patients (29 lesions) underwent serial OCT at 4 different time points (Cohort B1: post-procedure, 6, 24, and 60 months [n=13]; Cohort B2: post-procedure, 12, 36, and 60 months [n=15]) following implantation of the scaffold. In Cohort B1, there was no significant luminal change at the distal or proximal edge segment throughout the entire follow-up. In contrast, there was a significant reduction of the lumen flow area (LFA) of the scaffold between post-procedure and 6 months (-1.03±0.49 mm(2)[P<0.001]), whereas between 6 and 60 months the LFA remained stable (+0.31±1.00 mm(2)[P=0.293]). In Cohort B2, there was a significant luminal reduction of the proximal edge between post-procedure and 12 months (-0.57±0.74 mm(2)[P=0.017]), whereas the lumen area remained stable (-0.26±1.22 mm(2)[P=0.462]) between 12 and 60 months. The scaffold LFA showed a change similar to that observed in Cohort B1. CONCLUSIONS: Our study demonstrated a reduction in the scaffold luminal area in the absence of major EVR, suggesting that the physiological continuity of the lumen contour is restored long term. (Circ J 2016; 80: 1131-1141).


Assuntos
Implantes Absorvíveis/normas , Stents Farmacológicos/normas , Everolimo/administração & dosagem , Tomografia de Coerência Óptica/métodos , Reestenose Coronária , Vasos Coronários/patologia , Seguimentos , Humanos , Estudos Longitudinais
7.
Catheter Cardiovasc Interv ; 86(3): E140-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25914327

RESUMO

BACKGROUND: Three-dimensional (3D) quantitative coronary angiography (QCA) provides more accurate measurements by minimizing inherent limitations of two-dimensional (2D) QCA. The aim of this study was to compare the measurements between 2D and 3D QCA analyses in bifurcation lesions. METHODS AND RESULTS: A total of 114 cases with non-left main bifurcation lesions in the TRYTON pivotal IDE Coronary Bifurcation Trial (ClinicalTrials.gov: NCT01258972) were analyzed using a validated bifurcation QCA software (CAAS 5.10, Pie Medical Imaging, Maastricht, the Netherlands). All cases were analyzed in matched projections between pre- and post-procedure. The 2D analysis was performed using one of two angiographic images used for 3D reconstruction showing a larger distal bifurcation angle. In the treated segments (stent and balloon), there were no differences in minimal luminal diameter (MLD) between 2D and 3D, while diameter stenosis (DS) was significantly higher in 2D compared to 3D both pre-procedure and post-procedure (53.9% for 2D vs. 52.1% for 3D pre-procedure, P < 0.01; 23.2% for 2D vs. 20.9% for 3D post-procedure, P = 0.01). In the sub-segment level analysis, lengths of proximal main branch, distal main branch, and side branch were consistently shorter in 2D compared to 3D both pre-procedure and post-procedure. Using 3D QCA, the anatomic location of the smallest MLD or the highest DS was relocated to a different bifurcation sub-segment in a considerable proportion of the patients compared to when 2D-QCA was used (kappa values: 0.50 for MLD, 0.55 for DS). CONCLUSIONS: Our data showed differences in addressing anatomical severity and location of coronary bifurcation lesions between in vivo 2D and 3D QCA analyses. More studies are needed to investigate potential clinical benefits in using 3D approach over 2D QCA for the assessment of bifurcation lesions.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Imageamento Tridimensional , Software , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 85(4): 554-63, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25059819

RESUMO

BACKGROUND: The accuracy and precision of quantitative coronary angiography (QCA) software dedicated for bifurcation lesions compared with conventional single-vessel analysis remains unknown. Furthermore, comparison of different bifurcation analysis algorithms has not been performed. METHODS: Six plexiglas phantoms with 18 bifurcations were manufactured with a tolerance < 10 µm. The bifurcation angiograms were analyzed using Cardiovascular Angiography Analysis System (CAAS; Version 5.10, Pie Medical Imaging, Maastricht, The Netherlands) and QAngio XA (Version 7.3, Medis Medical Imaging System BV, Leiden, The Netherlands) software packages. RESULTS: Conventional single-vessel analysis underestimated the reference vessel diameter and percent diameter stenosis in the proximal main vessel while it overestimated these parameters in the distal main vessel and side branch. CAAS software showed better overall accuracy and precision than QAngio XA (with automatic Y- or T-shape bifurcation algorithm selection) for various phantom diameters including minimum lumen diameter (0.012 ± 0.103 mm vs. 0.041 ± 0.322 mm, P = 0.003), reference vessel diameter (-0.050 ± 0.043 mm vs. 0.116 ± 0.610 mm, P = 0.026), and % diameter stenosis (-0.94 ± 4.07 % vs. 1.74 ± 7.49 %, P = 0.041). QAngio XA demonstrated higher minimal lumen diameter, reference vessel diameter, and % diameter stenosis when compared to the actual phantom diameters; however, the accuracy of these parameters improved to a similar level as CAAS when the sole T-shape algorithm in the QAnxio XA was used. CONCLUSION: The use of the single-vessel QCA method is inaccurate in bifurcation lesions. Both CAAS and QAngio XA (when the T shape is systematically used) bifurcation software packages are suitable for quantitative assessment of bifurcations.


Assuntos
Algoritmos , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Software , Humanos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
9.
Heart Vessels ; 30(6): 824-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25031154

RESUMO

Very late stent thrombosis (VLST) is a catastrophic complication after implantation of a drug-eluting stent (DES). It has been reported that VLST is associated with pathological changes, which often include late acquired incomplete stent apposition (LAISA) with thrombus formation. In addition, the vascular response to the stent (evaginations, neointimal growth, and thrombosis) and the incidence of LAISA are reported to vary among the different types of DES. We experienced a patient with cardiogenic shock induced by simultaneous VLST of both the left anterior descending artery (LAD) and the left circumflex artery (LCX) at 3 years after implantation of two sirolimus-eluting stents. Intravascular ultrasound (IVUS) showed LAISA of both arteries. A paclitaxel-eluting stent, which had been implanted in the right coronary artery 3 years earlier, did not show such a finding. IVUS revealed "different vascular reactions" to "different types of DES" in this patient.


Assuntos
Trombose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Choque Cardiogênico/etiologia , Angiografia Coronária , Trombose Coronária/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/uso terapêutico , Sirolimo/uso terapêutico , Resultado do Tratamento , Ultrassonografia de Intervenção
10.
Eur Heart J ; 35(12): 777-86, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24394380

RESUMO

AIMS: We evaluated the feasibility and the acute performance of the everolimus-eluting bioresorbable vascular scaffolds (BVS) for the treatment of patients presenting with ST-segment elevation myocardial infarction (STEMI). METHODS AND RESULTS: The present investigation is a prospective, single-arm, single-centre study, reporting data after the BVS implantation in STEMI patients. Quantitative coronary angiography and optical coherence tomography (OCT) data were evaluated. Clinical outcomes are reported at the 30-day follow-up. The intent-to-treat population comprises a total of 49 patients. The procedural success was 97.9%. Pre-procedure TIMI-flow was 0 in 50.0% of the patients; after the BVS implantation, a TIMI-flow III was achieved in 91.7% of patients and the post-procedure percentage diameter stenosis was 14.7 ± 8.2%. No patients had angiographically visible residual thrombus at the end of the procedure. Optical coherence tomography analysis performed in 31 patients showed that the post-procedure mean lumen area was 8.02 ± 1.92 mm(2), minimum lumen area 5.95 ± 1.61 mm(2), mean incomplete scaffold apposition area 0.118 ± 0.162 mm(2), mean intraluminal defect area 0.013 ± 0.017 mm(2), and mean percentage malapposed struts per patient 2.80 ± 3.90%. Scaffolds with >5% malapposed struts were 7. At the 30-day follow-up, target-lesion failure rate was 0%. Non-target-vessel revascularization and target-vessel myocardial infarction (MI) were reported. A non-target-vessel non-Q-wave MI occurred. No cases of cardiac death or scaffold thrombosis were observed. CONCLUSION: In the present series, the BVS implantation in patients presenting with acute MI appeared feasible, with high rate of final TIMI-flow III and good scaffold apposition. Larger studies are currently needed to confirm these preliminary data.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio/tratamento farmacológico , Sirolimo/análogos & derivados , Alicerces Teciduais , Moduladores de Tubulina/administração & dosagem , Implantes Absorvíveis , Everolimo , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sirolimo/administração & dosagem , Tempo para o Tratamento , Tomografia de Coerência Óptica , Resultado do Tratamento
11.
Circ J ; 78(8): 1873-81, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24942012

RESUMO

BACKGROUND: Quantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial. METHODS AND RESULTS: In serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months). CONCLUSIONS: Quantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/cirurgia , Monitorização Fisiológica/métodos , Tomografia de Coerência Óptica , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino
12.
Int J Cardiol ; 400: 131805, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38272132

RESUMO

BACKGROUND: The geographical disparity in the pathophysiological pattern of coronary artery disease (CAD) among patients undergoing percutaneous coronary intervention (PCI) is unknown. OBJECTIVES: To elucidate the geographical variance in the pathophysiological characteristics of CAD. METHODS: Physiological indices derived from angiography-based fractional flow reserve pullbacks from patients with chronic coronary syndrome enrolled in the ASET Japan (n = 206) and ASET Brazil (n = 201) studies, which shared the same eligibility criteria, were analysed. The pathophysiological patterns of CAD were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the µQFR pullback pressure gradient index. RESULTS: Significant functional stenoses pre-PCI (µQFR ≤0.80) were more frequent in ASET Japan compared to ASET Brazil (89.9% vs. 67.5%, p < 0.001), as were rates of a post-PCI µQFR <0.91 (22.1% vs. 12.9%, p = 0.013). In the multivariable analysis, pre-procedural µQFR and diffuse disease were independent factors for predicting a post-PCI µQFR <0.91, which contributed to the different rates of post-PCI µQFR ≥0.91 between the studies. Among vessels with a post-PCI µQFR <0.91, a consistent diffuse pattern of CAD pre- and post-PCI occurred in 78.3% and 76.7% of patients in ASET Japan and Brazil, respectively; only 6.3% (Japan) and 10.0% (Brazil) of vessels had a major residual gradient. Independent risk factors for diffuse disease were diabetes mellitus in ASET Japan, and age and male gender in Brazil. CONCLUSIONS: There was geographic disparity in pre-procedural angiography-based pathophysiological characteristics. The combined pre-procedural physiological assessment of vessel µQFR and diffuseness of CAD may potentially identify patients who will benefit most from PCI.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Masculino , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Angiografia Coronária , Resultado do Tratamento , Vasos Coronários , Valor Preditivo dos Testes
13.
Catheter Cardiovasc Interv ; 81(5): 776-81, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22517601

RESUMO

OBJECTIVES: We investigate the influence of stent design on stent coverage at 6-9 months after sirolimus eluting stent (SES) implantation using optical coherence tomography (OCT). BACKGROUND: Although some reports suggest that stent design may correlate with stent coverage of stent struts, there were few detailed data whether stent design impact on stent coverage in the same drug-eluting stent. METHODS: A total of 21 SESs (15 patients), who had implanted 2.5, 2.75, and 3.0 mm stents, underwent OCT at 6-9 months after stent implantation. SES is constructed by two different strut width-components; narrow strut width parts (59 µm) and wide strut width parts (115 µm). Thus, we divided stent struts of SESs into two groups: narrow strut width parts (narrow group) and wide ones (wide group). We compared the incidence of incomplete apposed struts, uncovered struts, and neointimal hyperplasia (NIH) thickness between the two groups. RESULTS: We could detect 2,948 struts (narrow group consisted of 1,132 struts and wide group consisted of 1,816 struts). Incidence of uncovered struts in the narrow group was significantly lower than in the wide group (30.2% vs. 40.8%, P < 0.001), and NIH thickness in the narrow group was significantly greater than in the wide group (127.5 ± 93.4 µm vs. 118.6 ± 81.4 µm, P = 0.03). CONCLUSIONS: Stent design, especially strut width, affects stent coverage of SES. The narrow strut may avoid the absence of stent coverage in SES, which correlates with stent thrombosis.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Trombose Coronária/prevenção & controle , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Doença da Artéria Coronariana/patologia , Trombose Coronária/etiologia , Trombose Coronária/patologia , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
14.
AsiaIntervention ; 9(1): 39-48, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36936091

RESUMO

The Acetyl Salicylic Elimination Trial (ASET) Japan pilot study is a multicentre, single-arm, open-label, proof-of-concept study with a stopping rule based on the occurrence of definite stent thrombosis. This study aims to demonstrate the feasibility and safety of low-dose prasugrel monotherapy following percutaneous coronary intervention (PCI) in Japanese patients presenting with chronic coronary syndromes (CCS) or non-ST-elevation acute coronary syndromes (NSTE-ACS). Four hundred patients with a SYNTAX score <23 requiring PCI due to CCS or NSTE-ACS will be screened and considered eligible for the study. The enrolment is planned in two phases: 1) 200 patients presenting with CCS, followed by 2) 200 patients presenting with NSTE-ACS. After optimal PCI with implantation of a SYNERGY (Boston Scientific) stent, patients will be enrolled and loaded with prasugrel 20 mg, followed by a maintenance dose of prasugrel 3.75 mg once daily without aspirin continued for 3 months in Phase 1 (CCS patients), and for 12 months in Phase 2 (NSTE-ACS patients). After these follow-up periods, prasugrel will be replaced by standard antiplatelet therapy according to local practice. The primary endpoint is a composite of cardiac death, target vessel myocardial infarction, or definite stent thrombosis after the index procedure. The primary bleeding endpoint is any Bleeding Academic Research Consortium type 3 or 5 bleeding occurring within 3 months of the index PCI for CCS patients, or 12 months for NSTE-ACS patients. The ASET Japan study is designed to demonstrate the feasibility and safety of reduced-dose prasugrel monotherapy after PCI in East Asian patients with acute and chronic coronary syndromes.

15.
EuroIntervention ; 19(11): e891-e902, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37960875

RESUMO

BACKGROUND: Even with intracoronary imaging-guided stent optimisation, suboptimal haemodynamic outcomes post-percutaneous coronary intervention (PCI) can be related to residual lesions in non-stented segments. Preprocedural assessment of pathophysiological coronary artery disease (CAD) patterns could help predict the physiological response to PCI. AIMS: The aim of this study was to assess the relationship between preprocedural pathophysiological haemodynamic patterns and intracoronary imaging findings, as well as their association with physiological outcomes immediately post-PCI. METHODS: Data from 206 patients with chronic coronary syndrome enrolled in the ASET-JAPAN study were analysed. Pathophysiological CAD patterns were characterised using Murray law-based quantitative flow ratio (µQFR)-derived indices acquired from pre-PCI angiograms. The diffuseness of CAD was defined by the pullback pressure gradient (PPG) index. Intracoronary imaging in stented segments after stent optimisation was also analysed. RESULTS: In the multivariable analysis, diffuse disease - defined by the pre-PCI µQFR-PPG index - was an independent factor for predicting a post-PCI µQFR <0.91 (per 0.1 decrease of PPG index, odds ratio 1.57, 95% confidence interval: 1.07-2.34; p=0.022), whereas the stent expansion index (EI) was not associated with a suboptimal post-PCI µQFR. Among vessels with an EI ≥80% and post-PCI µQFR <0.91, 84.0% of those vessels had a diffuse pattern preprocedure. There was no significant difference in EI between vessels with diffuse disease and those with focal disease. The average plaque burden in the stented segment was significantly larger in vessels with a preprocedural diffuse CAD pattern. CONCLUSIONS: A physiological diffuse pattern preprocedure was an independent factor in predicting unfavourable immediate haemodynamic outcomes post-PCI, even after stent optimisation using intracoronary imaging. Preprocedural assessment of CAD patterns could identify patients who are likely to exhibit superior immediate haemodynamic outcomes following PCI.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Vasos Coronários/patologia , Resultado do Tratamento , Hemodinâmica , Valor Preditivo dos Testes
16.
JACC Case Rep ; 4(16): 1020-1025, 2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-36062057

RESUMO

We present the case of a 75-year-old man who experienced rebleeding after surgical treatment of grade III coronary perforation, resulting in intertwined complications including communicating coronary and ventricular pseudoaneurysms. The percutaneous intervention of sealing the rebleeding site with a covered stent implantation managed this rare pseudoaneurysm successfully. (Level of Difficulty: Advanced.).

18.
EuroIntervention ; 16(16): 1333-1341, 2021 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-31289018

RESUMO

AIMS: The feasibility of offline optical coherence tomography (OCT) guidance in bifurcation (with either two-dimensional or three-dimensional images) and its potential benefits have been demonstrated in retrospective studies; however, these have not yet been investigated prospectively. The aim of this trial is to determine the superiority of online three-dimensional optical frequency domain imaging (3D-OFDI)-guided stenting to angiography-guided percutaneous coronary intervention (PCI) in terms of incomplete stent apposition (ISA) at the bifurcation segment. METHODS AND RESULTS: The OPTIMUM trial is a randomised, superiority, multicentre clinical trial. The primary endpoint of this trial is the post-procedural percentage of malapposed struts assessed by OFDI in the main branch bifurcation region after final kissing balloon dilatation (FKBD). A total of 106 patients will be randomly allocated to either 3D-OFDI guidance or angiography guidance PCI. Bifurcation lesions will be treated with a provisional single-stent strategy using the Ultimaster sirolimus-eluting stent. Patients randomised to the 3D-OFDI guidance arm will undergo OFDI assessment in the main branch (MV) after rewiring into the jailed side branch following stent implantation, while in the angiography guidance arm re-crossing of a wire into the side branch will be performed using conventional fluoroscopic/angiographic guidance. In patients in the 3D-OFDI guidance arm, if the position of the wire is not located in the optimal cell, further attempts to redirect the wire to the optimal cell will be performed, with subsequent OFDI acquisitions to confirm the re-crossing position. The proximal optimisation technique and FKBD are mandatory in this trial. The study will provide a 90% power to show superiority of 3D-OFDI guidance PCI compared with angiography-guided PCI. CONCLUSIONS: The OPTIMUM trial will be the first prospective, randomised trial to evaluate the efficacy and safety of online 3D-OFDI-guided PCI in bifurcation lesions. ClinicalTrials.gov Identifier: NCT02972489.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento
19.
Circ Cardiovasc Interv ; 13(12): e009183, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33272034

RESUMO

BACKGROUND: Clinical implications of online 3-dimensional optical frequency domain imaging (3D-OFDI)-guided stenting for bifurcation lesions have not been investigated in the randomized controlled trials. The purpose of this study was to determine whether online 3D-OFDI-guided stenting is superior to angiography-guided percutaneous coronary intervention (PCI) in terms of incomplete stent apposition at the bifurcation segment. METHODS: The OPTIMUM trial (Online 3-Dimensional Optical Frequency Domain Imaging to Optimize Bifurcation Stenting Using UltiMaster Stent) was a randomized, multicenter clinical trial. Eligible patients had an angiographically significant stenosis in the bifurcation lesion treated with a provisional single stent strategy using the Ultimaster sirolimus eluting stent. Patients were randomly allocated to either online 3D-OFDI-guided or angiography-guided PCI. Patients randomized to 3D-OFDI guidance underwent online 3D-OFDI assessment after rewiring into the jailed side branch after stenting and proximal optimization technique, while in the angiography guidance arm, rewiring was performed using conventional fluoroscopic/angiographic guidance. The primary end point of this trial was the postprocedural average percentage of malapposed struts per lesion assessed by OFDI in the confluence zone of the main and side branches. RESULTS: Between June 8, 2017 and September 26, 2018, 110 patients with 111 bifurcation lesions were randomized at 4 Japanese centers. Of these, 56 patients with 57 lesions were treated with 3D-OFDI-guided PCI, whereas 54 patients with 54 lesions were treated with angiography-guided PCI. In the 3D-OFDI guidance arm, the feasibility of online 3D-OFDI was 98.2%. The average percentage of incomplete stent apposition per lesion at bifurcation was lower in the 3D-OFDI guidance arm than that in the angiography guidance arm (19.5±15.8% versus 27.5±14.2%, P=0.008). The superiority of the 3D-OFDI guidance arm was also confirmed in the strut level analysis (odds ratio: 0.54 [95% CI, 0.36-0.81]; P=0.003). CONCLUSIONS: Online 3D-OFDI-guided bifurcation PCI was superior to angiography-guided bifurcation PCI in terms of acute incomplete stent apposition at bifurcation. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02972489.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Humanos , Estudos Prospectivos , Tomografia de Coerência Óptica , Resultado do Tratamento
20.
Cardiovasc Interv Ther ; 35(3): 250-258, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31422529

RESUMO

Very long-term data of the biodegradable polymer drug-eluting stents (BP-DES) in comparison with the contemporary durable polymer DES (DP-DES) are still to be investigated. We aimed to investigate the very long-term clinical performance of contemporary BP-DES against the DP-DES. We performed a systematic review to evaluate very long-term clinical outcomes of BP-DES versus DP-DES. Inclusion criteria were randomized design comparing BP-DES against DP-DES and follow-up duration ≥ 36 months. MEDLINE, EMBASE, and CENTRAL without restricting language or publication status were searched up to December 2018. The primary efficacy and safety endpoints were target lesion failure (TLF; a composite of cardiac death, target vessel myocardial infarction and ischemia-driven target lesion revascularization) and definite/probable stent thrombosis (ST), respectively. Primary analysis was done for the contemporary thin-strut BP- and DP-DES (strut thickness < 100 µm). A total of 9 trials comprising 10,699 patients (BP-DES, n = 6241 versus DP-DES, n = 4458) were analyzed. The mean follow-up duration was 63 months. No significant difference was found in TLF [Odds ratio (95% CI) 1.04 (0.89-1.21)] and definite/probable ST (odds ratio (95% CI) 0.78 (0.59-1.01)] between the BP- and DP-DESs. The present meta-analysis suggested that the contemporary thin-strut BP- and DP-DES have similar efficacy and safety profile at 5-year follow-up.Clinical trial registration PROSPERO; CRD42018101983 https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=101983.


Assuntos
Implantes Absorvíveis/efeitos adversos , Plásticos Biodegradáveis/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos/efeitos adversos , Equipamentos Médicos Duráveis , Intervenção Coronária Percutânea/instrumentação , Ensaios Clínicos Controlados Aleatórios como Assunto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA