RESUMO
PURPOSE: This study aimed to clarify the dosimetric impact of the respiratory motion of the liver on stereotactic body radiation therapy (SBRT) for spine metastasis and examine the utility of introducing beam avoidance (beam-off at specific gantry angles). METHODS: A total of 112 consecutive patients who underwent SBRT for spine metastasis between 2018 and 2024 were examined. Overall, 15 patients who had lesions near the liver dome were included in this study. Retrospective treatment plans were generated using computed tomography (CT) images acquired during inhalation and exhalation to evaluate the dosimetric impact of respiratory motion of the liver. The dose difference (DD) and relative value (DD%) were evaluated using the dose-volume histogram (DVH) metrics, planning target volume Dmax, D95%, spinal cord D0.035 cc, and esophagus D2.5 cc. The magnitude of the liver movements was evaluated based on differences of liver size Lave at the isocentric axial plane between the inspiratory and expiratory CT images. RESULTS: The DD in almost all DVH metrics tended to increase when the liver moved away from the target during inhalation: For example, Mean ± $ \pm $ a standard deviation (SD) DD in PTV D95% for the treatment plan incorporating beam avoidance and those without beam avoidance was 0.5 ± $\pm$ 0.3 and 0.9 ± $ \pm $ 0.6 Gy, respectively. The spinal cord D0.035 cc for those shows 0.4 ± $ \pm $ 0.2 and 0.7 ± $ \pm $ 0.7 Gy, respectively. The treatment plans without beam avoidance also showed moderate or strong correlations between Lave and DD for almost all DVH metrics. No correlation was seen in the beam avoidance plan. The spinal cord D0.035 cc revealed approximately 1 Gy or +4% in DD when Lave was < -4 cm. CONCLUSIONS: Respiratory motion of the liver dome can cause substantial dosimetric discrepancies in the dose delivered to the spinal cord, although the extent depends on patient variables. Dose assessment should be performed for determining the appropriate means of respiratory management, such as breath-hold. Alternatively, beam avoidance effectively mitigates the impact.
Assuntos
Fígado , Órgãos em Risco , Radiocirurgia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Respiração , Neoplasias da Coluna Vertebral , Humanos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos Retrospectivos , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/radioterapia , Neoplasias da Coluna Vertebral/cirurgia , Masculino , Feminino , Radioterapia de Intensidade Modulada/métodos , Fígado/diagnóstico por imagem , Fígado/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Idoso , Pessoa de Meia-Idade , Movimento , Tomografia Computadorizada por Raios X/métodos , Prognóstico , Idoso de 80 Anos ou maisRESUMO
INTRODUCTION: Scalp angiosarcoma is a rare and aggressive cancer. Definitive radiotherapy is a treatment option for localised scalp angiosarcoma patients. Although definitive surgical resection reportedly prolongs overall survival (OS), whether initial local treatment effect affects OS when definitive radiotherapy is administered is unclear. Therefore, this study analysed whether local recurrence within 6 months of irradiation correlates with OS and cancer-specific survival (CSS). Furthermore, how local control affects patients' quality of life was investigated. MATERIALS AND METHODS: Thirty-one localised scalp angiosarcoma patients who had received definitive radiotherapy at our institution between October 2010 and July 2021 were analysed retrospectively. The most commonly used dose fractionation was 70 Gy in 35 fractions (83.9%). Local recurrence within 6 months of radiotherapy and other clinical factors were examined in univariate and subsequent multivariate analyses for correlation with OS and CSS. RESULTS: The median follow-up period was 16 months (range, 6-45 months). Local recurrence was detected in 16 patients (51.6%), 12 of whom had recurrence within 6 months. In multivariate analyses, the presence of local recurrence within 6 months of radiotherapy was significantly associated with OS and CSS (p = 0.003, 0.0001, respectively). Ten of the 16 patients with local recurrence had severe symptoms such as bleeding, pain, difficulty opening the eye and malodour. CONCLUSIONS: The initial local treatment effect was significantly associated with OS and CSS after definitive radiotherapy. Furthermore, local recurrence after radiotherapy resulted in a variety of symptoms, including bleeding and pain, which reduced the patient's quality of life.
Assuntos
Hemangiossarcoma , Humanos , Hemangiossarcoma/radioterapia , Hemangiossarcoma/patologia , Couro Cabeludo/patologia , Estudos Retrospectivos , Relevância Clínica , Qualidade de Vida , DorRESUMO
BACKGROUND: The setup of lung shield (LS) in total body irradiation (TBI) with the computed radiography (CR) system is a time-consuming task and has not been quantitatively evaluated. The TBI mobile imager (TBI-MI) can solve this problem through real-time monitoring. Therefore, this study aimed to perform commissioning and performance evaluation of TBI-MI to promote its use in clinical practice. METHODS: The source-axis distance in TBI treatment, TBI-MI (CNERGY TBI, Cablon Medical B.V.), and the LS position were set to 400, 450, and 358 cm, respectively. The evaluation items were as follows: accuracy of image scaling and measured displacement error of LS, image quality (linearity, signal-to-noise ratio, and modulation transfer function) using an EPID QC phantom, optimal thresholding to detect intra-fractional motion in the alert function, and the scatter radiation dose from TBI-MI. RESULTS: The accuracy of image scaling and the difference in measured displacement of the LS was <4 mm in any displacements and directions. The image quality of TBI imager was slightly inferior to the CR image but was visually acceptable in clinical practice. The signal-to-noise ratio was improved at high dose rate. The optimal thresholding value to detect a 10-mm body displacement was determined to be approximately 5.0%. The maximum fraction of scattering radiation to irradiated dose was 1.7% at patient surface. CONCLUSION: MI-TBI can quantitatively evaluate LS displacement with acceptable image quality. Furthermore, real-time monitoring with alert function to detect intrafraction patient displacement can contribute to safe TBI treatment.
Assuntos
Planejamento da Radioterapia Assistida por Computador , Irradiação Corporal Total , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodosRESUMO
PURPOSE: We measure the dose distribution of gated delivery for different target motions and estimate the gating latency in a magnetic resonance-guided radiotherapy (MRgRT) system. METHOD: The dose distribution accuracy of the gated MRgRT system (MRIdian, Viewray) was investigated using an in-house-developed phantom that was compatible with the magnetic field and gating method. This phantom contains a simulated tumor and a radiochromic film (EBT3, Ashland, Inc.). To investigate the effect of the number of beam switching and target velocity on the dose distribution, two types of target motions were applied. One is that the target was periodically moved at a constant velocity of 5 mm/s with different pause times (0, 1, 3, 10, and 20 s) between the motions. During different pause times, different numbers of beams were switched on/off. The other one is that the target was moved at velocities of 3, 5, 8, and 10 mm/s without any pause (i.e., continuous motion). The gated method was applied to these motions at MRIdian, and the dose distributions in each condition were measured using films. To investigate the relation between target motion and dose distribution in the gating method, we compared the results of the gamma analysis of the calculated and measured dose distributions. Moreover, we analytically estimated the gating latencies from the dose distributions measured using films and the gamma analysis results. RESULTS: The gamma pass rate linearly decreased with increasing beam switching and target velocity. The overall gating latencies of beam-hold and beam-on were 0.51 ± 0.17 and 0.35 ± 0.05 s, respectively. CONCLUSIONS: Film measurements highlighted the factors affecting the treatment accuracy of the gated MRgRT system. Our analytical approach, employing gamma analysis on films, can be used to estimate the overall latency of the gated MRgRT system.
Assuntos
Planejamento da Radioterapia Assistida por Computador , Humanos , Movimento (Física) , Espectroscopia de Ressonância Magnética , Dosagem Radioterapêutica , Imagens de FantasmasRESUMO
An asymmetric dearomatization of indoles bearing α-diazoacetamide functionalities was developed for synthesizing high-value spiro scaffolds. A silver phosphate chemoselectively catalyzed the sterically challenging dearomatization, whereas more typically used metal catalysts for carbene transfer reactions, such as a rhodium complex, were not effective and instead resulted in a Büchner ring expansion or cyclopropanation. Mechanistic studies indicated that the spirocyclization occurred through a silver-assisted asynchronous concerted process and not via a silver-carbene intermediate. Analyses based on natural bond orbital population and a distortion/interaction model indicated that the degree of C-Ag mutual interaction is crucial for achieving a high level of enantiocontrol. In addition, an oxidative disconnection of a C(sp3)-C(sp2) bond in the product provided unconventional access to the corresponding chiral spirooxindole.
RESUMO
BACKGROUND: In definitive radiation therapy for prostate cancer, the SpaceOAR® System, a hydrogel spacer, is widely used to decrease the irradiated dose and toxicity of rectum. On the other hand, periprostatic abscesses formation and rectal perforation are known as rare adverse effects of SpaceOAR. Nevertheless, there is a lack of reports clarifying the association between aggravation of abscesses and radiation therapy, and hyperbaric oxygen therapy (HBOT) is effective for a peri-SpaceOAR abscess and rectal perforation. CASE PRESENTATION: We report a case of a 78-year-old high-risk prostate cancer patient. After SpaceOAR insertion into the correct space, he started to receive external beam radiation therapy (EBRT). He developed a fever, perineal pain and frequent urination after the completion of EBRT, and the magnetic resonance imaging (MRI) revealed a peri-SpaceOAR abscess. Scheduled brachytherapy was postponed, administration of antibiotics and opioid via intravenous drip was commenced, and transperineal drainage was performed. After the alleviation of the abscess, additional EBRT instead of brachytherapy was performed with MRI-guided radiation therapy (MRgRT). On the last day of the MRgRT, perineal pain reoccurred, and MRI and colonoscopy detected the rectal perforation. He received an intravenous antibiotics drip and HBOT, and fully recovered from the rectal perforation. CONCLUSIONS: Our report indicates that EBRT can lead to a severe rectum complication by causing inflammation for patients with a peri-SpaceOAR abscess. Furthermore, HBOT was effective for the peri-SpaceOAR abscess and rectal perforation associated with EBRT.
Assuntos
Braquiterapia/efeitos adversos , Oxigenoterapia Hiperbárica , Neoplasias da Próstata/radioterapia , Fístula Retal/etiologia , Fístula Retal/terapia , Abscesso Abdominal/etiologia , Abscesso Abdominal/terapia , Idoso , Braquiterapia/instrumentação , Humanos , Hidrogéis , Perfuração Intestinal/etiologia , Perfuração Intestinal/terapia , Masculino , Dosagem Radioterapêutica , Doenças Retais/etiologia , Doenças Retais/terapiaRESUMO
The approval of orphan anticancer drugs in Japan has increased to meet high social demand. Drug lag, namely the approval lag of new drugs, is recognized as a social issue in Japan. We investigated the approval lag and its components, submission lag and review-time lag, between Japan and the United States (US) to reveal whether an approval lag still exists, and to identify potential factors that may contribute to reducing the approval lag. Anticancer drugs approved in Japan between April 2004 and November 2017 were investigated using publicly available information. Results showed that the median approval lag of orphan anticancer drugs in 2016-2017 was 727.0 days (interquartile range, IQR, 310.0-1054.3). The approval lag was significantly correlated with the submission lag (correlation coefficient = 1.00, P < 0.001) but not with the review-time lag (correlation coefficient = -0.16, P = 0.22). The submission lag was significantly longer for orphan anticancer drugs than non-orphan drugs (median, 712.5 days [IQR, 186.0-1448.3] vs. 387.0 days [92.8-1096.0], P = 0.023). External collaboration in drug development was associated with a longer submission lag (coefficient = 762.1, P = 0.017), while breakthrough therapy designation in the US was associated with a shorter submission lag (coefficient = -832.8, P = 0.035). In conclusion, we revealed that an approval lag for orphan anticancer drugs still existed in 2016-2017. A submission lag for orphan anticancer drugs was the main component affecting the approval lag, and was longer than that for non-orphan drugs. External collaboration in drug development may be a potential factor in reducing the submission lag for orphan anticancer drugs.
Assuntos
Antineoplásicos/uso terapêutico , Aprovação de Drogas/legislação & jurisprudência , Aprovação de Drogas/estatística & dados numéricos , Neoplasias/tratamento farmacológico , Produção de Droga sem Interesse Comercial/legislação & jurisprudência , Ensaios Clínicos Fase III como Assunto , Humanos , Japão , Produção de Droga sem Interesse Comercial/estatística & dados numéricos , Fatores de Tempo , Estados Unidos , United States Food and Drug AdministrationRESUMO
The approval of orphan anticancer drugs has increased, with the number exceeding that of non-orphan drugs in Japan in recent years. Although orphan anticancer drugs may have unique characteristics due to their rarity, these have not been fully characterized. We investigated anticancer drugs approved in Japan between April 2004 and November 2017 to reveal the characteristics of regulatory approval and pivotal studies on orphan anticancer drugs compared to non-orphan drugs. The median regulatory review time and number of patients in pivotal studies on orphan anticancer drugs (281.0 days [interquartile range, 263.3-336.0]; 222.5 patients [66.0-454.3]) were significantly lower than those on non-orphan drugs (353.0 days [277.0-535.5]; 521.0 patients [303.5-814.5], respectively) (P < 0.001). Phase II, non-randomized and non-controlled designs were more frequently used in pivotal studies on orphan anticancer drugs (45.9%, 41.9% and 43.2%) than non-orphan drugs (17.2%, 14.1% and 14.1%, respectively). Response rate was more commonly used as a primary endpoint in pivotal studies on orphan anticancer drugs (48.6%) than non-orphan drugs (17.2%). Indications limited by molecular features, second or later treatment line, and accelerated approval in the United States were associated with the use of response rate in orphan anticancer drug studies. In conclusion, we demonstrated that orphan anticancer drugs in Japan have unique characteristics compared to non-orphan drugs: shorter regulatory review and pivotal studies frequently using phase II, non-randomized, or non-controlled designs and response rate as a primary endpoint, with fewer patients.
Assuntos
Antineoplásicos/uso terapêutico , Aprovação de Drogas/legislação & jurisprudência , Ensaios Clínicos Fase II como Assunto , Humanos , Japão , Projetos de Pesquisa , Estados Unidos , United States Food and Drug Administration/legislação & jurisprudênciaRESUMO
A simple protocol to directly access γ-amino acid derivatives by intermolecular regioselective hydroamination of trichloroethyl alkenyldiazoacetates with carbamate using a silver tetrafluoroborate catalyst is described. Density functional theory (DFT) calculations to analyze the reaction mechanism revealed that multiple attractive interactions occur in a transition state to promote the vinylogous addition of nitrogen nucleophiles.
RESUMO
We report asymmetric dearomatization of phenols using Ag carbenoids from α-diazoacetamides. The Ag catalyst promoted intramolecular dearomatization of phenols, whereas a Rh or Cu catalyst caused C-H insertion and a Büchner reaction. Studies indicated Ag carbenoids have a carbocation-like character, making their behavior and properties unique. Highly enantioselective transformations using Ag carbenoids have not been reported. We achieved a Ag carbenoid-mediated chemo- and highly enantioselective phenol dearomatization with substrate generality for the first time.
RESUMO
The present study aimed to summarize and report data on errors related to treatment planning, which were collected by medical physicists. The following analyses were performed based on the 10-year error report data: (1) listing of high-risk errors that occurred and (2) the relationship between the number of treatments and error rates, (3) usefulness of the Automated Plan Checking System (APCS) with the Eclipse Scripting Application Programming Interface and (4) the relationship between human factors and error rates. Differences in error rates were observed before and after the use of APCS. APCS reduced the error rate by ~1% for high-risk errors and 3% for low-risk errors. The number of treatments was negatively correlated with error rates. Therefore, we examined the relationship between the workload of medical physicists and error occurrence and revealed that a very large workload may contribute to overlooking errors. Meanwhile, an increase in the number of medical physicists may lead to the detection of more errors. The number of errors was correlated with the number of physicians with less clinical experience; the error rates were higher when there were more physicians with less experience. This is likely due to the lack of training among clinically inexperienced physicians. An environment to provide adequate training is important, as inexperience in clinical practice can easily and directly lead to the occurrence of errors. In any environment, the need for additional plan checkers is an essential factor for eliminating errors.
Assuntos
Erros Médicos , Planejamento da Radioterapia Assistida por Computador , Humanos , Erros Médicos/prevenção & controle , Carga de TrabalhoRESUMO
Accelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.
Assuntos
Terapia por Captura de Nêutron de Boro , Lítio , Nêutrons , Terapia por Captura de Nêutron de Boro/métodos , Lítio/química , Humanos , Aceleradores de Partículas , Dosagem RadioterapêuticaRESUMO
Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.
RESUMO
Previous plan competitions have largely focused on dose metric assessments. However, whether the submitted plans were realistic and reasonable from a quality assurance (QA) perspective remains unclear. This study aimed to investigate the relationship between aperture-based plan complexity metrics (PCM) in volumetric modulated arc therapy (VMAT) competition plans and clinical treatment plans verified through patient-specific QA (PSQA). In addition, the association of PCMs with plan quality was examined. A head and neck (HN) plan competition was held for Japanese institutions from June 2019 to July 2019, in which 210 competition plans were submitted. Dose distribution quality was quantified based on dose-volume histogram (DVH) metrics by calculating the dose distribution plan score (DDPS). Differences in PCMs between the two VMAT treatment plan groups (HN plan competitions held in Japan and clinically accepted HN VMAT plans through PSQA) were investigated. The mean (± standard deviation) DDPS for the 98 HN competition plans was 158.5 ± 20.6 (maximum DDPS: 200). DDPS showed a weak correlation with PCMs with a maximum r of 0.45 for monitor unit (MU); its correlation with some PCMs was "very weak." Significant differences were found in some PCMs between plans with the highest 20% DDPSs and the remaining plans. The clinical VMAT and competition plans revealed similar distributions for some PCMs. Deviations in PCMs for the two groups were comparable, indicating considerable variability among planners regarding planning skills. The plan complexity for HN VMAT competition plans increased for high-quality plans, as shown by the dose distribution. Direct comparison of PCMs between competition plans and clinically accepted plans showed that the submitted HN VMAT competition plans were realistic and reasonable from the QA perspective. This evaluation may provide a set of criteria for evaluating plan quality in plan competitions.
Assuntos
Neoplasias de Cabeça e Pescoço , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Garantia da Qualidade dos Cuidados de SaúdeRESUMO
An implantable loop recorder (ILR) is now widely used for differential diagnosis of unexplained syncope or recurrent syncope with unknown causes. In the inherited arrhythmia syndromes, ILR may be useful for management of the therapeutic strategies; however, there is no obvious evidence to uncover arrhythmic syncope by ILR in long-QT syndrome (LQTS) patients. Here we experienced a 19-year-old female patient with LQTS type 1 who had recurrent syncope even after beta-blocker therapy but no arrhythmias were documented, and some episodes might be due to non-cardiogenic causes. Implantable cardioverter defibrillator (ICD) therapy was also recommended; however, she could not accept ICD but was implanted with ILR for further continuous monitoring. Two years later, she suffered syncope during a brief run, and ILR recorded an electrocardiogram at that moment. Thus a marked QT interval prolongation as well as T-wave alternance resulting in development of torsades de pointes could be detected. Although ILR is just a diagnostic tool but does not prevent sudden cardiac death, most arrhythmic events in LQTS are transient and sometimes hard to be diagnosed as arrhythmic syncope. ILR may provide direct supportive evidence to select the optimal therapeutic strategy in cases where syncope is difficult to diagnose. Learning objective: Long-QT syndrome (LQTS) patients often suffer recurrent syncope even after beta-blocker therapy, but torsades de pointes (TdP) is not always detected by standard 12lead electrocardiogram or Holter monitoring, and some syncope might be non-cardiogenic. In this case, implantable loop recorder (ILR) documented the evidence of QT interval prolongation and beat-by-beat T-wave alternance subsequent TdP. Thus, ILR may provide useful evidence for the optimal treatment strategy in LQTS cases where syncope is difficult to diagnose.
RESUMO
Objectives: Hydrogel spacer (HS) was developed to reduce rectal toxicities caused by radiotherapy, but has been reported to cause major adverse events. Our institute has attempted to introduce a hyaluronic acid (HA) as an alternative spacer. This study aimed to compare rectal doses and geometric distributions between the HS and HA implantation in prostate cancer. Methods: HS and HA were inserted in 20 and 18 patients undergoing high-dose brachytherapy, respectively. The rectum spacer volumes injected were 10 mL and 22 mL, respectively. In the treatment planning system, 13.5 Gy was administered with common catheter positions. The rectal dose indices were assessed between the spacer groups for dosimetry evaluation. Distances between the prostate and rectum and configurations of the spacers were compared. Results: The mean doses irradiated to 0.1 and 2 mL of the rectum were 10.45 Gy and 6.71 Gy for HS, and 6.73 Gy and 4.90 Gy for HA (p<0.001). The mean minimum distances between the prostate and rectum were 1.23 cm and 1.79 cm for HS and HA, respectively (p<0.05). Geometrical configuration comparisons revealed that HA has a higher ability to expand the space than HS. Conclusion: The rectal dose reduction ability of HA is significantly greater than that of HS, suggesting its potential as a new spacer.
RESUMO
OBJECTIVES: This is a multicenter, collaborative study to accumulate cases of small cell carcinoma of the uterine cervix (SmCC), to clarify its clinical and clinicopathologic features and prognosis, and to obtain findings to establish future individualized treatment. METHODS: At medical centers participating in the Kansai Clinical Oncology Group/Intergroup, patients diagnosed with SmCC between 1997 and 2007 were enrolled. Clinicopathologic features and prognosis were retrospectively evaluated in patients with SmCC diagnosed at a central pathologic review. RESULTS: A total of 71 patients were registered at 25 medical centers in Japan. Of these, 52 patients (73%) were diagnosed with SmCC based on a pathological review. These 52 patients diagnosed with SmCC were analyzed. The median follow-up period was 57 months. The 4-year progression-free survival (PFS) was: IB1, 59%; IB2, 68%; IIB, 13%; and IIIB, 17%. The 4-year overall survival (OS) was: IB1, 63%; IB2, 67%; IIB, 30%; IIIB, 29%; and IVB, 25%. For postoperative adjuvant therapy, postoperative chemotherapy (a platinum drug in all cases) was compared to non-chemotherapy. The 4-year PFS was 65% and 14%, and the 4-year OS was 65% and 29%. PFS was significantly better (p=0.002), and the OS tended to be better (p=0.073) in the group with postoperative chemotherapy. CONCLUSION: Even in patients with early stage SmCC, the prognosis is poor. However, in early stage patients, by adding postoperative chemotherapy, the prognosis may improve. Currently, various treatment protocols are used at each medical center, but in the future, a standardized treatment protocol for SmCC will hopefully be established.
Assuntos
Carcinoma de Células Pequenas/diagnóstico , Carcinoma de Células Pequenas/terapia , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Pequenas/patologia , Carcinoma de Células Pequenas/cirurgia , Terapia Combinada , Intervalo Livre de Doença , Feminino , Humanos , Japão , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Medicina de Precisão , Estudos Retrospectivos , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/cirurgia , Adulto JovemRESUMO
BACKGROUND: This study was designed to evaluate the efficacy of definitive radiation therapy (RT) for invasive carcinoma of the vagina. METHODS: Twenty-six patients with invasive carcinoma of the vagina who received RT were studied retrospectively. The median age was 68 years. The pathologic subtype of vaginal carcinoma was squamous cell carcinoma in 24 patients, adenosquamous cell carcinoma in one patient, and adenocarcinoma in one patient. The distribution of clinical stage according to the International Federation of Gynecology and Obstetrics staging system was as follows: stage I, seven patients; stage II, 10 patients, stage III, seven patients; and stage IVA, two patients. Twenty patients received external beam radiation therapy (EBRT) combined with high-dose rate intracavitary brachytherapy (HDR-ICBT), and three received EBRT alone. The remaining three patients with stage I disease were given HDR-ICBT alone. The median dose was 50 Gy for EBRT, and 23 Gy for HDR-ICBT. Systemic chemotherapy was administered concurrently with RT to three patients. RESULTS: The median follow-up was 90 months. The initial rate of response to RT was 100%, and complete remission was attained in 21 patients (81%). The 5-year overall survival rate (OS) and the median survival time of the 26 patients were 57% and 97 months, respectively. The 5-year OS for the three patients who received HDR-ICBT alone was 100%. Severe toxicity occurred in three patients-grade 3 rectal hemorrhage in one, grade 3 cystitis in one, and grade 4 cystitis in one. CONCLUSIONS: Our results demonstrated that definitive RT with HDR-ICBT is effective for invasive carcinoma of the vagina, with acceptable toxicity.
Assuntos
Braquiterapia/efeitos adversos , Carcinoma/radioterapia , Neoplasias Vaginais/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/métodos , Carcinoma/patologia , Feminino , Seguimentos , Humanos , Pessoa de Meia-Idade , Invasividade Neoplásica/patologia , Estadiamento de Neoplasias , Doses de Radiação , Resultado do Tratamento , Neoplasias Vaginais/patologiaRESUMO
Streptococcus pneumoniae (pneumococcus) is a pathogenic gram-positive bacterium that causes pneumonia, meningitis, and sepsis. Pneumococcal surface protein A (PspA) induces antibodies that protect against lethal infections by pneumococci. PspA is a choline-binding protein present on the cell surface of almost all pneumococcal strains and is a non-capsular polysaccharide vaccine candidate. For research and development of PspA-based vaccines, an in-vitro test system to measure the activity of functional antibodies capable of killing pneumococci is essential. The opsonophagocytic killing (OPK) assay is used to evaluate the opsonic activity of functional antibodies induced by capsular polysaccharide (CPS)-based vaccines (standard OPK assay). Despite the potential of anti-PspA antibodies to protect against lethal infections in mice, the standard OPK assay fails to evaluate anti-PspA antibodies. Using a pneumococcal surface protein C-deficient strain and extending the incubation time of opsonized bacteria, complement, and HL-60 cells reportedly results in enhanced bactericidal activity (modified OPK assay). We aimed to measure the bactericidal activity of anti-PspA antibodies in intact pneumococcal strains. We optimized the pneumococcal culture method used in the OPK assay to increase the efficiency of anti-PspA antibody-mediated phagocytosis of HL-60 cells. As thick capsules hinder phagocytosis, we attempted to obtain pneumococci with thin capsules through an improved culture method. As pneumococci attached to cells exhibit thin capsules, pneumococci cultured in Todd Hewitt yeast extract (THY) broth were spread on blood agar plates and incubated for 4 h. cpsA mRNA transcript levels in pneumococci cultured on blood agar were lower than those in pneumococci cultured in THY broth. OPK activity against pneumococci expressing PspA of clades 1-5 was reasonably well detected using pneumococci cultured on blood agar in the modified OPK assay. The modified OPK assay for anti-PspA antibody using pneumococci cultured on blood agar represents a useful assay to determine the killing activity of functional anti-PspA antibodies against pneumococci.
Assuntos
Infecções Pneumocócicas , Streptococcus pneumoniae , Animais , Camundongos , Proteínas de Membrana , Ágar , Cápsulas , Anticorpos Antibacterianos , Polissacarídeos , Proteínas de Bactérias/metabolismo , Vacinas PneumocócicasRESUMO
The uterus is known as one of the moving organs. We evaluated the movement of the uterus during irradiation and the effects of changes in the surrounding organs using a magnetic resonance (MR)-guided radiotherapy system. Seven patients with cervical cancer underwent pre- and posttreatment MR imaging to assess changes in the positioning of the uterus and cervix as well as the alterations in bladder and rectal volume. The study revealed that the movements of the uterus were greater than that of the cervix and showed a tendency to correlate with the bladder rather than the rectum. We also examined whether intrafractional motion could lead to insufficient dose coverage of the clinical target volume (CTV), specifically focusing on the D98% of the CTV in the uterine body and cervix. The impact of intrafractional motion on the D98% varied among patients, with one out of the seven patients experiencing an average dosimetric change of -2.6 Gy in the uterus, although larger planning target volume margins of 1.5 cm were applied, therefore, indicating the need for individualized optimal margins in each case. Online adaptive radiotherapy offers the advantage of modifying the treatment plan when irradiating moving organs, such as the uterus. However, it should be noted that this approach may result in longer overall treatment times compared with the traditional methods. Therefore, we must carefully consider the influence of intrafractional organ motions when opting for such a treatment.